Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMOMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Coherent Anti-Stokes Raman Spectroscopic Thermometry in a Supersonic Combustor

An experiment has been conducted to acquire data for the validation of computational fluid dynamics codes used in the design of supersonic combustors. The flow in a supersonic combustor, consisting of a diverging duct with a single downstream-angled wail injector, is studied. Combustor entrance Mach number is 2 and enthalpy nominally corresponds to Mach 7 flight. The primary measurement technique is coherent anti-Stokes Raman spectroscopy, but surface pressures and temperatures have also been acquired. Modern design of experiment techniques have been used to maximize the quality of the data set (for the given level of effort) and to minimize systematic errors. Temperature maps are obtained at several planes in the flow for a case in which the combustor is piloted by injecting fuel upstream of the main injector and one case in which it is not piloted. Boundary conditions and uncertainties are characterized.

Cutler, A. D.↗

Improved Readout Scheme for SQUID-Based Thermometry

An improved readout scheme has been proposed for high-resolution thermometers, (HRTs) based on the use of superconducting quantum interference devices (SQUIDs) to measure temperature- dependent magnetic susceptibilities. The proposed scheme would eliminate counting ambiguities that arise in the conventional scheme, while maintaining the superior magnetic-flux sensitivity of the conventional scheme. The proposed scheme is expected to be especially beneficial for HRT-based temperature control of multiplexed SQUIDbased bolometer sensor arrays. SQUID-based HRTs have become standard for measuring and controlling temperatures in the sub-nano-Kelvin temperature range in a broad range of low-temperature scientific and engineering applications. A typical SQUIDbased HRT that utilizes the conventional scheme includes a coil wound on a core made of a material that has temperature- dependent magnetic susceptibility in the temperature range of interest. The core and the coil are placed in a DC magnetic field provided either by a permanent magnet or as magnetic flux inside a superconducting outer wall. The aforementioned coil is connected to an input coil of a SQUID. Changes in temperature lead to changes in the susceptibility of the core and to changes in the magnetic flux detected by the SQUID. The SQUID readout instrumentation is capable of measuring magnetic-flux changes that correspond to temperature changes down to a noise limit .0.1 nK/Hz1/2. When the flux exceeds a few fundamental flux units, which typically corresponds to a temperature of .100 nK, the SQUID is reset. The temperature range can be greatly expanded if the reset events are carefully tracked and counted, either by a computer running appropriate software or by a dedicated piece of hardware.

Penanen, Konstantin↗

Quantitative Radiation Thermometry Using Commercially Available High-Speed Video Cameras

In order to understand the risk posed to astronauts by electric arc-generated particles, high-speed, high-resolution, quantitative thermal imaging was needed. The measurement requirements appeared to be beyond the capabilities of commercial thermal imaging systems, but the particles were known to have a significant amount of emission in the visible spectrum. This led to the use of commercially available, high-speed video cameras as imaging radiometers. Measured particle temperatures were consistent with predictions and other measurement data. The optical temperature measurement method, results, and conclusions are presented, along with recommendations for further work.

Thermal imaging↗

High Temperature Thermographic Phosphor Coatings Development

For many years, phosphor thermometry has been used for non-contact temperature measurements. A large number of applications have been associated with high temperatures, especially for aerospace systems where blackbody radiation backgrounds are large and in challenging environments, such as vibration, rotation, flame, or noise. These environments restrict the use of more common thermocouples or infrared thermometric techniques. In particular, temperature measurements inside jet turbines, rocket engines, or similar devices are especially amenable to phosphor techniques. Often the fluorescent materials are used as powders, either suspended in binders and applied like paint or applied as high-temperature sprays. Thin coatings that are less than 50 m thick are used on the surfaces of interest. These coatings will quickly assume the same temperature as the surface to which they are applied. The temperature dependence of fluorescent materials is a function of the base matrix atoms and a small quantity of added activator or dopant ions. Often for high temperature applications, the selected materials are refractory and include rare earth ions. Phosphors like Y3Al5O12 (YAG) doped with Eu, Dy, or Tm, Y2O3 doped with Eu, or similar rare earth compounds, will survive high temperatures and can be configured to emit light that changes rapidly in lifetime and intensity. For example, researchers at Oak Ridge National Laboratory recently observed fluorescence from YAG:Dy and YAG:Tm at temperatures above 1400 C. One of the biggest challenges is to locate a binder material that can withstand tremendous variations in temperature in an adverse aerospace environment. This poster will provide an overview into our attempt to utilize phosphors for thermometry purposes. Emphasis will be placed on the use of selected binder materials that can withstand high temperatures. This research was completed for the National Aeronautics and Space Administration's Glenn Research Center in Cleveland, Ohio.

Goedeke, Shawn↗

Junction-to-Case Thermal Resistance of a Silicon Carbide Bipolar Junction Transistor Measured

Junction temperature of a prototype SiC-based bipolar junction transistor (BJT) was estimated by using the base-emitter voltage (V(sub BE)) characteristic for thermometry. The V(sub BE) was measured as a function of the base current (I(sub B)) at selected temperatures (T), all at a fixed collector current (I(sub C)) and under very low duty cycle pulse conditions. Under such conditions, the average temperature of the chip was taken to be the same as that of the temperature-controlled case. At increased duty cycle such as to substantially heat the chip, but same I(sub C) pulse height, the chip temperature was identified by matching the V(sub BE) to the thermometry curves. From the measured average power, the chip-to-case thermal resistance could be estimated, giving a reasonable value. A tentative explanation for an observed bunching with increasing temperature of the calibration curves may relate to an increasing dopant atom ionization. A first-cut analysis, however, does not support this.

Niedra, Janis M.↗

Monolayer Graphene Bolometer as a Sensitive Far-IR Detector

In this paper we give a detailed analysis of the expected sensitivity and operating conditions in the power detection mode of a hot-electron bolometer (HEB) made from a few micro m(sup 2) of monolayer graphene (MLG) flake which can be embedded into either a planar antenna or waveguide circuit via NbN (or NbTiN) superconducting contacts with critical temperature approx. 14 K. Recent data on the strength of the electron-phonon coupling are used in the present analysis and the contribution of the readout noise to the Noise Equivalent Power (NEP) is explicitly computed. The readout scheme utilizes Johnson Noise Thermometry (JNT) allowing for Frequency-Domain Multiplexing (FDM) using narrowband filter coupling of the HEBs. In general, the filter bandwidth and the summing amplifier noise have a significant effect on the overall system sensitivity.

noise thermometry↗

July 1973 ground survey of active Central American volcanoes

The author has identified the following significant results. Ground survey has shown that thermal anomalies of various sizes associated with volcanic activity at several Central American volcanoes should be detectable from Skylab. Anomalously hot areas of especially large size (greater than 500 m in diameter) are now found at Santiaguito and Pacaya volcanoes in Guatemala and San Cristobal in Nicaragua. Smaller anomalous areas are to be found at least seven other volcanoes. This report is completed after ground survey of eleven volcanoes and ground-based radiation thermometry mapping at these same points.

Stoiber, R. E.↗

Physical oceanography from satellites: Currents and the slope of the sea surface

A global scheme using satellite altimetry in conjunction with thermometry techniques provides for more accurate determinations of first order leveling networks by overcoming discrepancies between ocean leveling and land leveling methods. The high noise content in altimetry signals requires filtering or correction for tides, etc., as well as carefully planned sampling schemes.

Sturges, W.↗

Investigations of coherent anti-Stokes Raman spectroscopy /CARS/ for combustion diagnostics

Investigations of coherent anti-Stokes Raman spectroscopy (CARS) in a variety of flames are presented. Thermometry has received the primary emphasis in these studies, but species spectral and sensitivity studies will also be described. CARS is generated by mixing a 10 pps, frequency-doubled neodymium 'pump' laser with a spectrally broadband, laser-pumped, Stokes-shifted dye laser. This approach obviates the requirement to frequency scan the dye laser and generates the entire CARS spectrum with each pulse permitting, in principle, instantaneous measurements of medium properties. CARS spectra of N2, CO, O2, H2O, CO2 and CH4 in flames will be presented. In general these spectra exhibit very good agreement with computer synthesized spectra and permit measurements of temperature and species concentration. To illustrate the applicability of CARS to practical combustion diagnostics, CARS signatures from N2 have been employed to map the temperature field throughout a small, luminous, highly sooting propane diffusion flame

Eckbreth, A. C.↗

Interpretation of integrated-disk photometry of Callisto and Ganymede

The Lumme-Bowell (1981) theory has been used to interpret the integrated phase curves of Callisto and Ganymede, and it is noted that while the theory explains the brightness angles of these satellites up to about 80 deg solar phase angle, the observed brightness drops off at larger angles more rapidly than predicted. It is suggested that this discrepancy is due to the fact that single regolith particles must have phase functions which are much more elongated in the forward or backward scattering directions than is allowed for by the Lumme-Bowell theory. The hemispheric asymmetry in Callisto's surface texture can be explained by invoking the formation of an ice film on the trailing side, consistent with Voyager detailed photometry and thermometry of Callisto.

Pang, K.↗

Atomic fluorescence study of high temperature aerodynamic levitation

Ultraviolet laser induced atomic fluorescence has been used to characterize supersonic jet aerodynamic levitation experiments. The levitated specimen was a 0.4 cm sapphire sphere that was separately heated at temperatures up to 2327 K by an infrared laser. The supersonic jet expansion and thermal gradients in the specimen wake were studied by measuring spatial variations in the concentration of atomic Hg added to the levitating argon gas stream. Further applications of atomic fluorescence in containerless experiments, such as ideal gas fluorescence thermometry and containerless process control are discussed.

Nordine, P. C.↗

An experimental study of heat induced surface-tension driven flow

Laser Doppler anemometry, radiation thermometry, and time-lapse photography have been used to study heat induced surface-tension driven flows in silicone oil and Fluorinert FC-43 in large open containers. For silicone oil, the effect of the surface tension gradient on the velocity field was not apparent enough to be detected. Because of its high viscosity, the oil was insensitive to outside disturbances, and the flow was steady. In the case of FC-43, the fluid was noticeably influenced by outside disturbances, and the flow was unsteady. The work reported here is part of an effort to develop experimental techniques and select test fluids for future space experiments on fluid motion in materials processing.

Kamotani, Y.↗

Automated ac galvanomagnetic measurement system

An automated, ac galvanomagnetic measurement system is described. Hall or van der Pauw measurements in the temperature range 10-300 K can be made at a preselected magnetic field without operator attendance. Procedures to validate sample installation and correct operation of other system functions, such as magnetic field and thermometry, are included. Advantages of ac measurements are discussed.

Szofran, F. R.↗

Containerless Atomic-Fluorescence Property Measurements

Report describes studies conducted to establish and verify use of laser-induced fluorescence in monitoring and controlling high-temperature containerless processes. Specimens levitated by gas jets or electromagnetic fields and heated by laser beams or electromagnetic induction while being irradiated and detected by fluorescence technique. Makes quantitative and qualitative comparisons among three new methods of temperature measurement; all rely on laser-induced fluorescence. One method gas-density thermometry with seed gas. Other two methods involve measurements of velocities of evaporating atoms or of population ratios of different electronic states.

Nordine, P.↗

Original structures, and fragmentation and reassembly histories of asteroids - Evidence from meteorites

The validity of an onion shell model (OSM) for chondrite parent asteroids was assessed using metallographic cooling rates (MCR) derived from the compositions of metallic Fe-Ni grains. The hypothesis evaluated was that the hottest materials in chondrites would have been buried the deepest and cooled the slowest. The survey covered breccia from regolith and 13 different chondrites. The MCRs agreed well with cooling rates predicted by fission-track thermometry and Ar-40/Ar-39 ages. The OSM predicts an inverse correlation between the cooling rate and the petrographic type. Low correlations found between the MCRs and petrographic type indicate that chondrite parent asteroids were not assembled with onion shell structures.

Taylor, G. Jeffrey↗