Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMOSTATS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Assessing the performance of global thermostat adjustment in commercial buildings for load shifting demand response

Abstract Efficiently leveraging new sources of flexibility is critical to mitigating load balancing challenges posed by variable renewable resources. The thermal inertia of commercial buildings allows us to shift their power consumption on minute to hourly timescales to provide demand response to the grid while maintaining occupant comfort. Global thermostat adjustment (GTA) provides a readily available and scalable approach for implementing load shifting demand response using commercial heating, ventilation, and air conditioning (HVAC) systems, since it leverages the inherent sophistication of modern building automation systems. However, there is an incomplete understanding of GTA’s performance for this purpose and its impact on building systems and occupant comfort. In this paper, we explore the performance of GTA by analyzing results from nearly nine hundred experiments on eight university campus buildings in Michigan and North Carolina. Using GTA, we manipulate each building’s thermostat setpoints causing the building to shift its power consumption with respect to its baseline. We quantify the magnitude of HVAC power response, energy use of HVAC subsystems, and impact on occupant comfort. Finally, we connect our experimental results with power system operation using an optimization model that coordinates GTA actions across a large collection of grid-interactive efficient buildings (GEBs) to reduce high ramp rates on the grid and mitigate renewable energy curtailment. Overall, our work finds that the impacts on HVAC subsystems are often complex, and may result in additional energy being consumed by fans and terminal reheat. These effects must be considered when using GTA for load shifting. Additionally, we demonstrate that occupant comfort, as assessed by indoor temperature and humidity, can be maintained during GTA events. From a societal perspective, our modeling work finds that the additional renewable energy that can be integrated through the use of GTA strategies eclipses any additional energy consumed by buildings.

Keskar, Aditya (ORCID:0000000244617980)↗

Short-Term Forecasting of Thermostatic and Residential Loads Using Long Short-Term Memory Recurrent Neural Networks

Internet of Things (IoT) devices in smart grids enable intelligent energy management for grid managers and personalized energy services for consumers. Investigating a smart grid with IoT devices requires a simulation framework with IoT devices modeling. However, there lack comprehensive study on the modeling of IoT devices in smart grids. This paper investigates the IoT device modeling of a thermostatic load and implements the recurrent neural networks model for short-term load forecasting in this IoT-based thermostatic load. The recurrent neural network structure is leveraged to build a load forecasting model on temporal correlation. The temporal recurrent neural network layers including long short-term memory cells are employed to learn the data from both the simulation platform and New South Wales residential datasets. The simulation results are provided for demonstration.

electric load forecasting↗

Data-driven Identification of Occupant Thermostat-Behavior Dynamics

Building occupant behavior drives significant differences in building energy use, even in automated buildings. Users’ distrust in the automation causes them to override settings. This results in responses that fail to satisfy both the occupants’ and/or the building automation’s objectives. The transition toward grid-interactive efficient buildings will make this evermore important as complex building control systems optimize not only for comfort, but also changing electricity costs. This paper presents a data-driven approach to study thermal comfort behavior dynamics which are not captured by standard steady-state comfort models such as predicted mean vote. The proposed model captures the time it takes for a user to override a thermostat setpoint change as a function of the manual setpoint change magnitude. The model was trained with the ecobee Donate Your Data dataset of 5 min. resolution data from 27,764 smart thermostats and occupancy sensors. The resulting population-level model shows that, on average, a 2°F override will occur after ~30 mins. and an 8°F override will occur in only ~15 mins., indicating the magnitude of discomfort as a key driver to the swiftness of an override. Such models could improve demand response programs through personalized controls.

Kane, Michael↗

Cirrus-cloud thermostat for tropical sea surface temperature tested using satellite data

Cirrus clouds associated with tropical convection may shield the ocean from sunlight and therefore act as a thermostat to limit tropical SST (sea surface temperature) to less than 305 K. This hypothesis was tested using satellite radiance data. It was found that changes in the properties of cirrus clouds do not seem to be related to changes in SSTs. During the 1987 El Nino event large-scale atmospheric circulation changes rather than the direct effect of SSTs seemed to control large-scale changes in radiative effects of cirrus clouds. If averaged over the entire tropical Pacific, increases in surface evaporative cooling are stronger than decreases in solar heating owing to cirrus cloud variation. This would indicate that there is no cirrus cloud thermostat to tropical SSTs.

Fu, Rong↗

Cooled Panel With Thermostats In All Passages

Simple shape-memory-alloy or bimaterial thermostatic valve incorporated in each passage of multiple-passage cooled panel, according to proposal. Thermostatic valves all set to same opening/closing temperature, so they regulate flows in all passages to equalize or nearly equalize temperature across panel in presence of transient, nonuniform surface heating. Concept beneficial in application in which overheating causes damage and both overcooling and excessive circulation of coolant occurs in absence of regulation if cooling capacity of panel made large enough to handle peak heat load. Potential applications include cooled structures for advanced hypersonic aircraft and engines.

Blosser, Max L.↗

Building America Case Study: The Impact of Thermostat Placement in Low-Load Homes in Sunny Climates, Denver, Colorado

Modern, energy-efficient homes conforming to the Zero Energy Ready Home standard face the challenge of meeting high customer expectations for comfort. Traditional heating, ventilation, and air conditioning (HVAC) sizing and control strategies may be insufficient to adequately condition each zone due to unique load patterns in each room caused by a number of factors. These factors include solar heat gains, occupant-related gains, and gains associated with appliances and electronics. Because of shrinking shell loads, these intermittent factors are having an increasingly significant impact on the thermal load in each zone. Consequently, occupant comfort can be compromised. To evaluate the impact of climate and house geometry, as well as HVAC system and control strategies on comfort conditions, IBACOS analyzed the results of 99 TRNSYS multiple-zone simulations. The results of this analysis indicate that for simple-geometry and single-story plans, a single zone and thermostat can adequately condition the entire house. Demanding house geometry and houses with multiple stories require the consideration of multiple thermostats and multiple zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

System and method for characterization of retrofit opportunities in building using data from communicating thermostats

Systems and methods for characterization of retrofit opportunities are described. The methods may comprise computing, using at least one computing device disposed remote from a building and based at least in part on heating, ventilation and air conditioning (HVAC) runtime data associated with the building, one or more thermal characteristics of the building. In some embodiments, a model-predicted indoor temperature may be fitted against thermal data measured by a thermostat at the building. The thermal characteristic of the building may comprise a thermal insulation, an air leakage rate and/or an HVAC efficiency. The method may be used to determine, using the at least one computing device, suitability of the building for a retrofit opportunity to improve energy efficiency of the building. Determining the suitability may comprise evaluating the one or more thermal characteristics. The HVAC runtime data may be computed based on data received from a thermostat or a meter, such as an electric or a gas meter.

Zeifman, Michael↗

Multifamily Programmable Thermostat Data

This data set, compiled by the Fraunhofer Center for Sustainable Energy Systems, includes long-term 10-minute temperature and relative humidity data, and HVAC system state data for 79 apartments in a low-income housing complex in Revere, MA. The monitoring period spans two winters and one summer between 2011 and 2013. Data were collected as part of a project sponsored by the U.S. Department of Energy Building America program to evaluate the impact of programmable thermostat usability on occupant behavior. This project was done in conjunction with NREL as part of the US Department of Energy's Building America program.

Array↗

Residential retrofits at scale: opportunity identification, saving estimation, and personalized messaging based on communicating thermostat data

Basic insulation and heating system retrofits of existing homes could achieve annual energy savings of up to $4–5 billion in the USA. However, current US utility energy efficiency (EE) programs are costly and challenging to scale. Customer acquisition occurs primarily through energy bill mailers, mass media, and on-line advertising that lack specificity about particular home retrofit opportunities, expected energy savings, and cost-effectiveness. Specific retrofit opportunities are identified via on-site home energy assessments that can be inconvenient to homeowners, expensive, and of variable accuracy. Our paper discusses using communicating thermostat data to significantly increase the customer uptake of energy conservation measures (ECMs) by identifying homes with the most significant retrofit opportunities, estimating post-retrofit energy savings, and formulating home-specific outreach. We extended our previously developed gray-box building model to identify physical building parameters corresponding to the target retrofit opportunities, i.e., whole-home R value, air leakage characteristics, and heating system efficiency. Here, the estimated R values and air leakage characteristics compare favorably with the ground truth. The validated algorithms can calculate home-specific energy savings estimate for each ECM, and the algorithm outputs can be used by utility EE programs to formulate home-specific retrofit offers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building thermal dynamics modeling with deep transfer learning using a large residential smart thermostat dataset

Understanding thermal dynamics and obtaining the computational model of residential buildings enable its scaled application in energy retrofits, control optimization and decarbonization. In this paper, we present a deep learning approach to model building thermal dynamics with smart thermostat data collected from residential buildings, with the goal to investigate model generalizability. In the first stage, we developed and compared different Deep Learning architectures including Convolutional Neural Networks (CNN), Long Short-Term Memory (LSTM) models and CNN-LSTM to predict indoor air temperature in a multi-step time horizon. In the second stage, we implemented a Transfer Learning (TL) process, which aims to improve the prediction performance on a new set of buildings (targets), exploiting the knowledge of related or similar buildings (sources). Different TL strategies and source model identification methods were investigated. The study showed that the CNN-LSTM performed the best among the architectures compared, with an average Mean Absolute Error (MAE) of 0.26 °C for one-hour-ahead (twelve 5-min future steps) predictions. Furthermore, the results showed that freezing the LSTM layer and fine-tuning the other layers of the CNN-LSTM achieved the best performance among four TL strategies, which further improved the performance with respect to a machine learning approach by 10%, and proving the effectiveness and generalizability of the proposed approach. A comparison of three different source model identification methods showed that randomly selecting source models constrained by similar building characteristics can provide good TL performance while retaining simplicity comparing with other quantitative source identification methods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Discretization errors in molecular dynamics simulations with deterministic and stochastic thermostats

We investigate the influence of numerical discretization errors on computed averages in a molecular dynamics simulation of TIP4P liquid water at 300 K coupled to different deterministic (Nose-Hoover and Nose-Poincare) and stochastic (Langevin) thermostats. We propose a couple of simple practical approaches to estimating such errors and taking them into account when computing the averages. We show that it is possible to obtain accurate measurements of various system quantities using step sizes of up to 70% of the stability threshold of the integrator, which for the system of TIP4P liquid water at 300 K corresponds to the step size of about 7 fs.

97 MATHEMATICS AND COMPUTING↗

The Nosé–Hoover looped chain thermostat for low temperature thawed Gaussian wave-packet dynamics

We have used a generalised coherent state resolution of the identity to map the quantum canonical statistical average for a general system onto a phase-space average over the centre and width parameters of a thawed Gaussian wave packet. We also propose an artificial phase-space density that has the same behaviour as the canonical phase-space density in the low-temperature limit, and have constructed a novel Nosé–Hoover looped chain thermostat that generates this density in conjunction with variational thawed Gaussian wave-packet dynamics. This forms a new platform for evaluating statistical properties of quantum condensed-phase systems that has an explicit connection to the time-dependent Schrödinger equation, whilst retaining many of the appealing features of path-integral molecular dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Informing the planning of rotating power outages in heat waves through data analytics of connected smart thermostats for residential buildings

Abstract With climate change, heat waves have become more frequent and intense. Rotating power outages happen when the power supply is unable to meet the cooling demand increase resulting from extreme high temperatures. Power outages during heat waves expose residents to high risks of overheating. In this study, we propose a novel data-driven inverse modelling approach to inform decision makers and grid operators on planning rotating power outages. We first infer the building thermal characteristics using the connected smart thermostat data, and used the estimated thermal dynamics to simulate the thermal resilience during a heat wave event. Our proposed method was tested for the California power outage in August 2020 by using the open source Ecobee Donate Your Data dataset. We found in California the power outage should not last more than two hours during heat waves to avoid overheating risks. Informing the residents in advance so they can prepare for it through pre-cooling is a simple but effective strategy to expand the acceptable power outage duration. In addition to assisting power outage planning, the proposed method can be used for other applications, such as to evaluate a building energy efficiency policy, to examine fuel poverty, and to estimate the load shifting potential of building stocks.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Geometric Approach to Aggregate Flexibility Modeling of Thermostatically Controlled Loads

Coordinated aggregation of a large population of thermostatically controlled loads (TCLs) presents a great potential to provide various ancillary services to the grid. One of the key challenges in coordination and control of TCLs is developing a simple and portable model to accurately extract their aggregate flexibility. In this paper, we propose a novel geometric approach to model the aggregate flexibility of TCLs. We show that the set of admissible power profiles of an individual TCL is a polytope, and their aggregate flexibility is the Minkowski sum of the individual polytopes. In order to represent their aggregate flexibility in an intuitive way and achieve a tractable approximation, we develop optimization-based algorithms to approximate the polytopes by the homothets of a given convex set. As a special application, this set is chosen as a virtual battery model and the corresponding optimal approximation problems are solved efficiently by equivalent linear programs. Numerical results show that our algorithms yield significant improvement in characterizing the aggregate flexibility over existing modeling methods. Finally, we also conduct case studies to demonstrate the efficacy of our approaches by coordinating TCLs to track a frequency regulation signal from the Pennsylvania-New Jersey-Maryland (PJM) Interconnection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Peak Power Minimization for Commercial Thermostatically Controlled Loads in Multi-Unit Grid-Interactive Efficient Buildings

The load profiles of most commercial and industrial consumers are characterized by brief periods of very high power consumption followed by intervals of lower demand. To encourage such consumers to flatten their load profiles, power utilities in and around the world often levy a monthly demand charge (DC) on the peak demand measured over brief intervals. In this work, we consider the joint optimization of energy costs (EC) and the instantaneous peak power of a multi-unit building which uses a hydronic heating, ventilation and cooling (HVAC) system and responds to a demand response (DR) program. Despite the non-linear structure of the problem, we show how optimal solutions can be obtained efficiently using linear programming. Next, we study the power demand patterns resulting from our proposed strategy for thermostatically controlled loads (TCLs), and evaluate the strategy’s performance for various climate zones in the US, under both typical and atypical weather conditions. Finally, the results show that depending on the ambient conditions and the tariff structure, our strategy can result in utility bill savings of up to nearly 19% compared to the baseline. The results also indicate that our power control strategy can significantly reduce the instantaneous peak power consumption in commercial TCLs.

HVAC↗

Thermostatic Radiator Valve Evaluation

A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermostatic Radiator Valve Evaluation

A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market. In this project, the ARIES team sought to better understand the current usage of TRVs by key market players in steam and hot water heating and to conduct limited experiments on the effectiveness of new and old TRVs as a means of controlling space temperatures and reducing heating fuel consumption. The project included a survey of industry professionals, a field experiment comparing old and new TRVs, and cost-benefit modeling analysis using BEopt™ (Building Energy Optimization software).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Validation of Algorithms That Analyze Communicating Thermostat Data to Identify Enclosure Retrofit Opportunities

Annual energy savings of up to $\$ 4$ to $\$ 5$ billion could be achieved nationwide through basic insulation and heating system retrofits of existing homes. However, current utility energy efficiency programs are costly and challenging to scale. Customer acquisition occurs primarily through energy bill mailers, mass media, and online advertising that lack specificity about home-specific retrofit opportunities, expected energy savings, and cost-effectiveness. Specific retrofit opportunities are identified via on-site home energy assessments (HEAs) that are inconvenient to homeowners, expensive, and of variable accuracy. We developed computational algorithms that automatically analyze communicating thermostat (CT) heating data that could be used to increase the customer uptake of insulation and air sealing energy conservation measures (ECMs) by identifying homes with the most significant retrofit opportunities, estimating post-retrofit energy savings, and formulating home-specific outreach. The algorithms are based on an extended second-order grey-box model that characterizes a building’s thermal response using lumped elements, coupled with an empirical model of infiltration that accounts for both wind and stack effects. The basic parameters of the model correspond to actual physical parameters of the home, i.e., the home’s overall R-value of and the building envelope ACH50. Unlike the conventional approach, which estimates model parameters based on the best fit to the observed time-dependent room temperature, our approach derives correlations between the daily heating system runtime and temperature difference (indoor-outdoor) that are more robust to data quality issues in real-world applications. We also used HEA data for algorithm development and validation. With the help of our utility partners, Eversource and National Grid, we obtained data sets for hundreds of Massachusetts homes. For each home, these data sets included three sets of information anonymized by the utility: (1) CT data (HVAC runtime, room temperature, and, for some vendors, outdoor temperature and wind speed) collected by the CT vendor (one of three) over a heating season, (2) HEA report performed by the HEA vendor (same vendor for all homes), (3) Monthly utility gas bills coincident with the CT data (3 to 24 per home, depending on availability). For some homes, we also obtained blower-door test results. Initially, we applied the algorithms developed to homes with a single CT and then extended them to homes with two CTs by using an equivalent home approach. Finally, we developed algorithms for prediction of energy savings and a methodology of comparing our predictions with those generated by HEAs. The main technical results indicate that we can reliably identify homes with insulation and/or air sealing retrofit opportunities and provide accurate savings predictions. Our hypothesis is that the algorithms could be applied to utility energy efficiency programs to identify homes that could realize significant energy savings from insulation and/or air sealing retrofits. This information could then be used to reach out to those homes with highly customized outreach, thereby delivering increased program energy savings and cost-effectiveness. This would: Significantly increase the uptake rate of on-site HEAs, and Significantly increase the fraction of HEAs resulting in ECM implementation. To test these hypotheses, we designed and conducted a randomized controlled trial (RCT). The RCT results suggest that personal messaging leads to a two- to five-fold increase in the HEA uptake rate.