Search NASA⌕ Search

SEARCH · Search NASA

Results for “THROMBIN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Differential elastic responses to barrier-altering agonists in two types of human lung endothelium

Vascular integrity is primarily determined by endothelial cell (EC) cytoskeletal structure that is differentially regulated by various stimuli. In this study, atomic force microscopy (AFM) was used to characterize structural and mechanical properties in the cytoskeleton of cultured human pulmonary artery EC (HPAEC) and human lung microvascular EC (HLMVEC) by determining elastic properties (Young's modulus) in response to endogenous barrier protective agents sphingosine 1-phosphate (S1P) and hepatocyte growth factor (HGF), or the barrier disruptive molecule thrombin. Initial studies in unstimulated cells indicate higher baseline peripheral elastic modulus values in HPAEC (mean 2.9 KPa) than in HLMVEC (1.8 KPa). After 30 min of stimulation, S1P induced the highest Young's modulus increase (6.1 KPa) compared to the other barrier enhancing stimuli, HGF (5.8 KPa) and the pharmaceutical agent and S1P analog FTY720 (4.1 KPa). In contrast, the barrier disruptive agent thrombin decreased values from 2.5 KPa to 0.7 KPa depending on the cell type and treatment time. AFM topographical imaging supports these quantitative biophysical data regarding differential peripheral elastic properties in EC. Overall, these AFM studies provide novel insights into the biomechanical properties of human lung EC that regulate vascular barrier function and have potential applicability to pathophysiologic vascular leak syndromes such as acute lung injury. - Highlights: • AFM dynamically measures cellular biophysical properties in live endothelial cells. • Macrovascular human lung EC exhibit different biophysical responses than microvascular. • Agonists that promote EC barrier function increase peripheral elastic properties. • Provide insights into potential therapeutic modulation of human lung EC.

60 APPLIED LIFE SCIENCES↗

Light-activated protein inhibition through photoinduced electron transfer of a ruthenium(II)–cobalt(III) bimetallic complex

In this paper, we describe a mechanism of light activation that initiates protein inhibitory action of a biologically inert Co(III) Schiff base (Co(III)-sb) complex. Photoinduced electron transfer (PET) occurs from a Ru(II) bipyridal complex to a covalently attached Co(III) complex and is gated by conformational changes that occur in tens of nanoseconds. Reduction of the Co(III)-sb by PET initiates displacement of the inert axial imidazole ligands, promoting coordination to active site histidines of α-thrombin. Upon exposure to 455 nm light, the rate of ligand exchange with 4-methylimidazole, a histidine mimic, increases by approximately 5-fold, as observed by NMR spectroscopy. Similarly, the rate of α-thrombin inhibition increases over 5-fold upon irradiation. Finally, these results convey a strategy for light activation of inorganic therapeutic agents through PET utilizing redox-active metal centers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanopore Activity Assays for Detection of Biomarker Protease Activity: Design and Testing of Substrates for Both Nanopore Sequencing and PCR-Based Detection Methods

The work performed in this project has demonstrated the ability to construct proteolytic enzyme substrates that are PCR and sequencing-readable reporter molecules. Specifically, the goal was to detect those reporter molecules via PCR and Oxford Nanopore Technologies MinION sequencing methods following exposure to the biomarker protease thrombin. The assay development focused on binding the constructed peptide-oligonucleotide chimera to immobilized streptavidin. The action of thrombin on the peptide portion of the molecule released the oligonucleotide for detection. Detection of protease activity was demonstrated in a concentration-dependent manner using MALDI-MS, RT-PCR and DNA sequencing. Additional steps to remove background release of reporter molecules during the assay was used to improve the difference in detected oligonucleotide reporter following protease activity. Additional steps in assay development will be to (1) test the assay in an appropriate matrix, (2) investigate detection using additional DNA sequencing platforms and (3) demonstrate multiplexed detection of multiple protease markers in a single reaction.

59 BASIC BIOLOGICAL SCIENCES↗

Percutaneous Injection Therapy for a Peripheral Pulmonary Artery Pseudoaneurysm After Failed Transcatheter Coil Embolization

Coil embolization to occlude the feeding artery of a pseudoaneurysm is an effective treatment to control hemoptysis. However, a feeding artery of the pseudoaneurysm may not be identified at pulmonary angiography, resulting in a failure to obtain embolization. We describe here two cases of a Rasmussen aneurysm that was successfully treated with percutaneous injection of thrombin (case 1) and N-butyl cyanoacrylate (case 2) under ultrasonographic and fluoroscopic guidance after failed transcatheter coil embolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Cyanoacrylate Glue Injection into the Renal Pseudoaneurysm to Control Intractable Hematuria After Percutaneous Nephrolithotomy

We report a case of a 43-year-old man who developed intractable hematuria after percutaneous nephrolithotomy. Angiography detected a pseudoaneurysm arising from the lower polar artery; however, embolization could not be performed because of unfavorable vascular anatomy. A percutaneous thrombin injection under ultrasound guidance initially controlled the bleeding, but hematuria subsequently recurred as a result of recanalization of the aneurysm. The case was successfully managed with ultrasound- and fluoroscopic-guided direct injection of cyanoacrylate glue into the pseudoaneurysm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Usefulness of MRI to Differentiate Between Temporary and Long-Term Coronary Artery Occlusion in a Minimally Invasive Model of Experimental Myocardial Infarction

The surgical technique employed to determine an experimental ischemic damage is a major factor in the subsequent process of myocardial scar development. We set out to establish a minimally invasive porcine model of myocardial infarction using cardiac contrast-enhanced magnetic resonance imaging (ce-MRI) as the basic diagnostic tool. Twenty-seven domestic pigs were randomized to either temporary or permanent occlusion of the left anterior descending artery (LAD). Temporary occlusion was achieved by inflation of a percutaneous balloon in the left anterior descending artery directly beyond the second diagonal branch. Occlusion was maintained for 30 or 45 min, followed by reperfusion. Permanent occlusion was achieved via thrombin injection. Thirteen animals died peri- or postinterventionally due to arrhythmias. Fourteen animals survived the 30-min ischemia (four animals; group 1), the 45-min ischemia (six animals; group 2), or the permanent occlusion (4 animals; group 3). Coronary angiography and ce-MRI were performed 8 weeks after coronary occlusion to document the coronary flow grade and the size of myocardial scar tissue. The LAD was patent in all animals in groups 1 and 2, with normal TIMI flow; in group 3 animals, the LAD was totally occluded. Fibrosis of the left ventricle in group 1 (4.9 {+-} 4.4%; p = 0.008) and group 2 (9.4 {+-} 2.9%; p = 0.05) was significantly lower than in group 3 (14.5 {+-} 3.9%). Wall thickness of the ischemic area was significantly lower in group 3 versus group 1 and group 2 (2.9 {+-} 0.3, 5.9 {+-} 0.7, and 6.1 {+-} 0.7 mm; p = 0.005). The extent of late enhancement of the left ventricle was also significantly higher in group 3 (16.9 {+-} 2.1%) compared to group 1 (5.3 {+-} 5.4%; p = 0.003) and group 2 (9.7 {+-} 3.4%, p = 0.013). In conclusion, the present model of minimally invasive infarction coupled with ce-MRI may represent a useful alternative to the open chest model for studies of myocardial infarction and scar development.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Type II Endoleak After Endovascular Repair of Abdominal Aortic Aneurysm: Effectiveness of Embolization

The purpose of this study was to report our experience in treating type II endoleaks after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms. Two hundred eighteen patients underwent EVAR with a Zenith stent-graft from January 2000 to December 2005. During a follow-up period of 4.5 {+-} 2.3 years, solely type II endoleak was detected in 47 patients (22%), and 14 of them underwent secondary interventions to correct this condition. Ten patients had transarterial embolization, and four patients had translumbar/transabdominal embolization. The embolization materials used were coils, thrombin, gelatin, Onyx (ethylene-vinyl alcohol copolymer), and glue. Disappearance of the endoleak without enlargement of the aneurysm sac after the first secondary intervention was achieved in only five of these patients (5/13). One patient without surveillance imaging was excluded from analyses of clinical success. After additional interventions in four patients and the spontaneous disappearance of type II endoleak in two patients, overall clinical success was achieved in eight patients (8/12). One patient did not have surveillance imaging after the second secondary intervention. Clinical success after the first secondary intervention was achieved in two patients (2/9) in the transarterial embolization group and three patients (3/4) in the translumbar embolization group. The results of secondary interventions for type II endoleak are unsatisfactory. Although the small number of patients included in this study prevents reliable comparisons between groups, the results seem to favor direct translumbar embolization in comparison to transarterial embolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization of an Internal Iliac Artery Aneurysm after Image-Guided Direct Puncture

Objective: To evaluate the feasibility, safety, and efficacy of embolization of internal iliac artery aneurysm (IIAA) after percutaneous direct puncture under (cone-beam) computed tomography (CT) guidance. Methods: A retrospective case series of three patients, in whom IIAA not accessible by way of the transarterial route, was reviewed. CT-guided puncture of the IIAA sac was performed in one patient. Two patients underwent puncture of the IIAA under cone-beam CT guidance. Results: Access to the IIAA sac was successful in all three patients. In two of the three patients, the posterior and/or anterior division was first embolized using platinum microcoils. The aneurysm sac was embolized with thrombin in one patient and with a mixture of glue and Lipiodol in two patients. No complications were seen. On follow-up CT, no opacification of the aneurysm sac was seen. The volume of one IIAA remained stable at follow-up, and the remaining two IIAAs decreased in size. Conclusion: Embolization of IIAA after direct percutaneous puncture under cone-beam CT/CT-guidance is feasible and safe and results in good short-term outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Antiplatelet and Anticoagulant Drugs in Interventional Radiology

In treating peripheral arterial disease, a profound knowledge of antiplatelet and anticoagulative drug therapy is helpful to assure a positive clinical outcome and to anticipate and avoid complications. Side effects and drug interactions may have fatal consequences for the patient, so interventionalists should be aware of these risks and able to control them. Aspirin remains the first-line agent for antiplatelet monotherapy, with clopidogrel added where dual antiplatelet therapy is required. In case of suspected antiplatelet drug resistance, the dose of clopidogrel may be doubled; prasugrel or ticagrelor may be used alternatively. Glycoprotein IIb/IIIa inhibitors (abciximab or eptifibatide) may help in cases of hypercoagulability or acute embolic complications. Desmopressin, tranexamic acid, or platelet infusions may be used to decrease antiplatelet drug effects in case of bleeding. Intraprocedurally, anticoagulant therapy treatment with unfractionated heparin (UFH) still is the means of choice, although low molecular-weight heparins (LMWH) are suitable, particularly for postinterventional treatment. Adaption of LMWH dose is often required in renal insufficiency, which is frequently found in elderly patients. Protamine sulphate is an effective antagonist for UFH; however, this effect is less for LMWH. Newer antithrombotic drugs, such as direct thrombin inhibitors or factor X inhibitors, have limited importance in periprocedural treatment, with the exception of treating patients with heparin-induced thrombocytopenia (HIT). Nevertheless, knowing pharmacologic properties of the newer drugs facilitate correct bridging of patients treated with such drugs. This article provides a comprehensive overview of antiplatelet and anticoagulant drugs for use before, during, and after interventional radiological procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Management of Iatrogenic Native Renal Arterial Pseudoaneurysms

Purpose: Our purpose was to evaluate iatrogenic renal pseudoaneurysms, endovascular treatment, and outcomes. Methods: This retrospective study (2003-2011) reported the technical and clinical outcomes of endovascular therapy for renal pseudoaneurysms in eight patients (mean age, 46 (range 24-68) years). Renal parenchymal loss evaluation was based on digital subtraction angiography and computed tomography. Results: We identified eight iatrogenic renal pseudoaneurysm patients with symptoms of hematuria, pain, and hematoma after renal biopsy (n = 3), surgery (n = 3), percutaneous nephrolithotomy (n = 1), and endoscopic shock-wave lithotripsy (n = 1). In six patients, the pseudoaneurysms were small-sized (<20 mm) and peripherally located and were treated solely with coil embolization (n = 5). In one patient, coil embolization was preceded by embolization with 500-700 micron embospheres to control active bleeding. The remaining two patients had large-sized ({>=}50 mm), centrally located renal pseudoaneurysms treated with thrombin {+-} coils. Technical success with immediate bleeding cessation was achieved in all patients. There were no procedure-related deaths or complications (mean follow-up, 23.5 (range, 1-67) months). Conclusions: Treatment of renal pseudoaneurysms using endovascular approach is a relatively safe and viable option regardless of location (central or peripheral) and size of the lesions with minimal renal parenchymal sacrifice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility and Safety of Vascular Closure Devices in an Antegrade Approach to Either the Common Femoral Artery or the Superficial Femoral Artery

Introduction: The purpose of the present study was to analyze complications following antegrade puncture of the common femoral artery (CFA) and the superficial femoral artery (SFA) using vascular closure systems (VCS). Methods: A single-center, retrospective study was performed after obtaining approval from the institutional review board and informed consent from all patients. At our center, the CFA or SFA are used for arterial access. All patients were evaluated clinically on the same day. If there was any suspicion of an access site problem, Duplex ultrasound was performed. Results: Access location was the CFA in 50 patients and the SFA in 130 patients. The sheath size ranged from 4F to 10F. Two patients had to be excluded because of lack of follow-up. Successful hemostasis was achieved in 162 of 178 cases (91 %). The following complications were observed in 16 patients (8.9 %): 4 pseudoaneurysms (2.2 %), 11 hematomas (6.2 %), and 1 vascular occlusion (0.5 %). The two pseudoaneurysms healed spontaneously, in one case an ultrasound-guided thrombin injection was performed, and one aneurysm was compressed manually. No further medical therapy was needed for the hematomas. The one vascular occlusion was treated immediately with angioplasty using a contralateral approach. No significant difference was noted between the CFA and the SFA group with respect to complications (p = 1.000). Conclusions: The use of closure devices for an antegrade approach up to 10F is feasible and safe. No differences in low complication rates were observed between CFA and SFA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Treatment of Iatrogenic Pseudoaneurysms by Cyanoacrylate-Based Wall-Gluing

Purpose. Although the majority of iatrogenic pseudoaneurysms (PSAs) are amenable to ultrasound (US)-guided thrombin injection, patients with those causing neuropathy, claudication, significant venous compression, or soft tissue necrosis are considered poor candidates for this option and referred to surgery. We aimed to test the effectiveness and feasibility of a novel percutaneous cyanoacrylate glue (NBCA-MS)-based technique for treatment of symptomatic and asymptomatic iatrogenic PSA. Material and Methods. During a 3-year period, we prospectively enrolled 91 patients with iatrogenic PSA [total n = 94 (femoral n = 76; brachial n = 11; radial n = 6; axillary n = 1)]. PSA were asymptomatic in 66 % of cases, and 34 % presented with symptoms due to neuropathy, venous compression, and/or soft tissue necrosis. All patients signed informed consent. All patients received NBCA-MS-based percutaneous treatment. PSA chamber emptying was first obtained by US-guided compression; superior and inferior walls of the PSA chamber were then stuck together using NBCA-MS microinjections. Successfulness of the procedure was assessed immediately and at 1-day and 1-, 3-, and 12-month US follow-up. Results. PSA occlusion rate was 99 % (93 of 94 cases). After treatment, mean PSA antero-posterior diameter decrease was 67 {+-} 22 %. Neuropathy and vein compression immediately disappeared in 91 % (29 of 32) of cases. Patients with tissue necrosis (n = 6) underwent subsequent outpatient necrosectomy. No distal embolization occurred, nor was conversion to surgery necessary. Conclusion. PSA treatment by way of NBCA-MS glue injection proved to be safe and effective in asymptomatic patients as well as those with neuropathy, venous compression, or soft-tissue necrosis (currently candidates for surgery). Larger series are needed to confirm these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanical Thrombectomy of Iliac Vein Thrombosis in a Pig Model Using the Rotarex and Aspirex Catheters

Purpose: To investigate the efficacy and safety of mechanical thrombectomy for iliac vein thrombosis using Rotarex and Aspirex catheters in a pig model. Materials and Methods: Iliac vein thrombosis was induced in six pigs by means of an occlusion-balloon catheter and thrombin injection. The presence of thrombi was verified by digital subtraction angiography (DSA) and computed tomography (CT). Thrombectomy was performed using 6F and 8F Rotarex and 6F, 8F, and 10F Aspirex catheters (Straub Medical AG, Wangs, Switzerland). After intervention, DSA and CT were repeated to evaluate the efficacy of mechanical thrombectomy and to exclude local complications. In addition, pulmonary CT was performed to rule out pulmonary embolism. Finally, all pigs were killed, and iliac veins were dissected to perform macroscopic and histological examination. Results: Thrombus induction was successfully achieved in all animals as verified by DSA and CT. Subsequent thrombectomy lead to incomplete recanalization of the iliac veins with residual thrombi in all cases. However, the use of the 6F and 8F Rotarex catheters caused vessel perforation and retroperitoneal hemorrhage in all cases. Application of the Aspirex device caused one small transmural perforation in a vessel treated with a 10F Aspirex catheter, and this was only seen microscopically. Pulmonary embolism was detected in one animal treated with the Rotarex catheters, whereas no pulmonary emboli were seen in animals treated with the Aspirex catheters. Conclusion: The Aspirex catheter allowed subtotal and safe recanalization of iliac vein thrombosis. In contrast, the use of the Rotarex catheter caused macroscopically obvious vessel perforations in all cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Use of ExoSeal Vascular Closure Device for Direct Antegrade Superficial Femoral Artery Puncture Site Hemostasis

PurposeThis study was designed to assess the efficacy and safety of the ExoSeal vascular closure device (VCD) to achieve hemostasis in antegrade access of the superficial femoral artery (SFA).MethodsWe retrospectively reviewed the outcome of ExoSeal VCD used for hemostasis in 110 accesses to the SFA in 93 patients between July 2011 and July 2013. All patients had patent proximal SFA based on computer tomography angiography or ultrasound duplex. Arterial calcifications at puncture site were graded using fluoroscopy. The SFA was accessed in an antegrade fashion with ultrasound or fluoroscopic guidance. In all patients, 5–7F vascular sheaths were used. The ExoSeal VCD was applied to achieve hemostasis at the end of the procedure. All patients were clinically examined and had ultrasound duplex exam for any puncture site complications during the 24 h postprocedure.ResultsIn all procedures, the ExoSeal was applied successfully. We did not encounter any device-related technical failure. There were four major complications in four patients (3.6 %): three pseudoaneurysms, which were treated with direct thrombin injection, and one hematoma, which necessitated transfusion of two blood units. All patients with complications were treated with anticoagulation preprocedure or received thrombolytic therapy.ConclusionsThe ExoSeal VCD can be safely used for antegrade puncture of the SFA, with a high procedural success rate (100 %) and a low rate of access site complications (3.6 %)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unenhanced Cone Beam Computed Tomography and Fusion Imaging in Direct Percutaneous Sac Injection for Treatment of Type II Endoleak: Technical Note

AimTo evaluate safety, feasibility, technical success, and clinical success of direct percutaneous sac injection (DPSI) for the treatment of type II endoleaks (T2EL) using anatomical landmarks on cone beam computed tomography (CBCT) and fusion imaging (FI).Materials and MethodsEight patients with T2EL were treated with DPSI using CBCT as imaging guidance. Anatomical landmarks on unenhanced CBCT were used for referencing T2EL location in the first five patients, while FI between unenhanced CBCT and pre-procedural computed tomography angiography (CTA) was used in the remaining three patients. Embolization was performed with thrombin, glue, and ethylene–vinyl alcohol copolymer. Technical and clinical success, iodinated contrast utilization, procedural time, fluoroscopy time, and mean radiation dose were registered.ResultsDPSI was technically successful in all patients: the needle was correctly positioned at the first attempt in six patients, while in two of the first five patients the needle was repositioned once. Neither minor nor major complications were registered. Average procedural time was 45 min and the average administered iodinated contrast was 13 ml. Mean radiation dose of the procedure was 60.43 Gy cm{sup 2} and mean fluoroscopy time was 18 min. Clinical success was achieved in all patients (mean follow-up of 36 months): no sign of T2EL was reported in seven patients until last CT follow-up, while it persisted in one patient with stability of sac diameter.ConclusionsDPSI using unenhanced CBCT and FI is feasible and provides the interventional radiologist with an accurate and safe alternative to endovascular treatment with limited iodinated contrast utilization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Day-Case Treatment of Peripheral Arterial Disease: Results from a Multi-Center European Study

PurposeThe purpose of the study was to investigate safety and feasibility of day-case endovascular procedures for the management of peripheral arterial disease.Materials and MethodsThis was a multi-center, retrospective study including all patients treated over a 30-month period with endovascular angioplasty or stenting for intermittent claudication (IC) or critical limb ischemia (CLI) on a day-case basis, in Interventional Radiology (IR) departments of three European tertiary hospitals. Exclusion criteria were not related to the type of lesion and included unavailability of an adult able to take care of patient overnight; high bleeding risk and ASA score ≥4. Primary efficacy outcome was the rate of procedures performed on an outpatient basis requiring no further hospitalization and primary safety outcome was freedom from 30-day major complications’ rate.ResultsThe study included 652 patients (male 75 %; mean age 68 ± 10 years; range: 27–93), 24.6 % treated for CLI. In 53.3 % of the cases a 6Fr sheath was used. Technical success was 97.1 %. Haemostasis was obtained by manual compression in 52.4 % of the accesses. The primary efficacy outcome occurred in 95.4 % (622/652 patients) and primary safety outcome in 98.6 % (643/652 patients). Major complications included five (0.7 %) retroperitoneal hematomas requiring transfusion; one (0.1 %) common femoral artery pseudoaneurysm successfully treated with US-guided thrombin injection, two cases of intra-procedural distal embolization treated with catheter-directed local thrombolysis and one on-table cardiac arrest necessitating >24 h recovery. No major complication was noted after same-day discharge.ConclusionsDay-case endovascular procedures for the treatment of IC or CLI can be safely and efficiently performed in experienced IR departments of large tertiary hospitals.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct Oral Anticoagulants: An Overview for the Interventional Radiologist

The direct oral anticoagulants (DOACs) have emerged as a good alternative for the treatment of thromboembolic diseases, and their use in clinical practice is increasing rapidly. The DOACs act by blocking the activity of one single step in the coagulation cascade. These drugs act downstream in the common pathway of the coagulation cascade by directly antagonising the action of thrombin or factor Xa. The development of DOACs represents a paradigm shift from the oral vitamin K antagonists such as warfarin. This article aims to describe the properties of the currently available DOACs including pharmacology and dosing. We also address the strategies for periprocedural management and reversal of anticoagulation of patients treated with these agents.

60 APPLIED LIFE SCIENCES↗