Search NASA⌕ Search

SEARCH · Search NASA

Results for “TIME DISCRIMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Generalized method for the optimization of pulse shape discrimination parameters

Organic scintillators exhibit fast timing, high detection efficiency for fast neutrons and pulse shape discrimination (PSD) capability. PSD is essential in mixed radiation fields, where different types of radiation need to be detected and discriminated. In neutron measurements for nuclear security and non proliferation effective PSD is crucial, because a weak neutron signature needs to be detected in the presence of a strong gamma-ray background. Here, the most commonly used deterministic PSD technique is charge integration (CI). This method requires the optimization of specific parameters to obtain the best gamma-neutron separation. These parameters depend on the scintillating material and light readout device and typically require a lengthy optimization process and a calibration reference measurement with a mixed source. In this paper, we propose a new method based on the scintillation fluorescence physics that enables to find the optimum PSD integration gates using only a gamma-ray emitter. We demonstrate our method using three organic scintillation detectors: deuterated trans-stilbene, small-molecule organic glass, and EJ-309. In all the investigated cases, our method allowed finding the optimum PSD CI parameters without the need of iterative optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The recognition of extraterrestrial artificial signals

Considerations in the design of receivers for the detection and recognition of artificial microwave signals of extraterrestrial origin are discussed. Following a review of the objectives of SETI and the probable reception and detection characteristics of extraterrestrial signals, means for the improvement of the sensitivity, signal-to-noise ratios and on-line data processing capabilities of SETI receivers are indicated. The characteristics of the signals likely to be present at the output of an ultra-low-noise microwave receiver are then examined, including the system background noise, terrestrial radiations, astrophysical radiations, accidental artificial radiations of terrestrial origin, and intentional radiations produced by humans and by extraterrestrial intelligence. The classes of extraterrestrial signals likely to be detected, beacons and leakage signals, are considered, and options in the specification of gating and thresholding for a high-spectral resolution, high-time-resolution signal discriminator are indicated. Possible tests for the nonhuman origin of a received signal are also pointed out.

Seeger, C. L.↗

A laser sounder for U.S. Navy helicopters

The design and operating principles of the laser sounder developed for use in airborne coastal-zone bathymetric surveys with a U.S. Navy P-3 aircraft are described and illustrated with diagrams. The sounder components are listed and characterized, including the Nd:YAG transmitter (operating at 532 nm for bottom ranging and 1.064 microns for surface ranging), the scanning transceiver, the 10 x 6-inch-aperture controlled-FOV receiver/digitizer, the constant-fraction discriminator, the time-to-digital converter, the navigation and data-recording subsystems, and the parallel distributed processing computer (comprising a data collection and control system and a real-time processing system). Consideration is also given to the phase-I and phase-II data-reduction software being developed to process the approximately 228 million soundings to be obtained annually. The sounder can be used day or night to sound clear ocean water up to 20 m deep.

Harris, Michael M.↗

Optical radiation measurements II; Proceedings of the Meeting, Orlando, FL, Mar. 27, 28, 1989

The present conference discusses topics in the characterization of imaging radiometers, laboratory instrumentation, field and spacecraft instrumentation, and quantum and thermal standard detectors. Attention is given to UV radiometric imaging, dual-color radiometer imagery, a novel diode-array radiometer, a novel reference spectrophotometer, radiance calibration of spherical integrators, instrumentation for measurement of spectral goniometric reflectance, and a real-time IR background discrimination radiometer. Also discussed are a multichannel radiometer for atmosphere optical property measurements, the UV spectroradiometric output of a turbojet, characterizations of the Earth Radiation Budget Experiment scanning radiometers, total-radiation thermometry, future directions in Si photodiode self-calibration, and radiometric quality Ge photodiodes.

Palmer, James M.↗

An Extended Objective Evaluation of the 29-km Eta Model for Weather Support to the United States Space Program

This report describes the Applied Meteorology Unit's objective verification of the National Centers for Environmental Prediction 29-km eta model during separate warm and cool season periods from May 1996 through January 1998. The verification of surface and upper-air point forecasts was performed at three selected stations important for 45th Weather Squadron, Spaceflight Meteorology Group, and National Weather Service, Melbourne operational weather concerns. The statistical evaluation identified model biases that may result from inadequate parameterization of physical processes. Since model biases are relatively small compared to the random error component, most of the total model error results from day-to-day variability in the forecasts and/or observations. To some extent, these nonsystematic errors reflect the variability in point observations that sample spatial and temporal scales of atmospheric phenomena that cannot be resolved by the model. On average, Meso-Eta point forecasts provide useful guidance for predicting the evolution of the larger scale environment. A more substantial challenge facing model users in real time is the discrimination of nonsystematic errors that tend to inflate the total forecast error. It is important that model users maintain awareness of ongoing model changes. Such changes are likely to modify the basic error characteristics, particularly near the surface.

Nutter, Paul↗

Dynamics of the spatial scale of visual attention revealed by brain event-related potentials

The temporal dynamics of the spatial scaling of attention during visual search were examined by recording event-related potentials (ERPs). A total of 16 young participants performed a search task in which the search array was preceded by valid cues that varied in size and hence in precision of target localization. The effects of cue size on short-latency (P1 and N1) ERP components, and the time course of these effects with variation in cue-target stimulus onset asynchrony (SOA), were examined. Reaction time (RT) to discriminate a target was prolonged as cue size increased. The amplitudes of the posterior P1 and N1 components of the ERP evoked by the search array were affected in opposite ways by the size of the precue: P1 amplitude increased whereas N1 amplitude decreased as cue size increased, particularly following the shortest SOA. The results show that when top-down information about the region to be searched is less precise (larger cues), RT is slowed and the neural generators of P1 become more active, reflecting the additional computations required in changing the spatial scale of attention to the appropriate element size to facilitate target discrimination. In contrast, the decrease in N1 amplitude with cue size may reflect a broadening of the spatial gradient of attention. The results provide electrophysiological evidence that changes in the spatial scale of attention modulate neural activity in early visual cortical areas and activate at least two temporally overlapping component processes during visual search.

Non-NASA Center↗

On the selection and evaluation of visual display symbology Factors influencing search and identification times

Three single-target visual search tasks were used to evaluate a set of cathode-ray tube (CRT) symbols for a helicopter situation display. The search tasks were representative of the information extraction required in practice, and reaction time was used to measure the efficiency with which symbols could be located and identified. Familiar numeric symbols were responded to more quickly than graphic symbols. The addition of modifier symbols, such as a nearby flashing dot or surrounding square, had a greater disruptive effect on the graphic symbols than did the numeric characters. The results suggest that a symbol set is, in some respects, like a list that must be learned. Factors that affect the time to identify items in a memory task, such as familiarity and visual discriminability, also affect the time to identify symbols. This analogy has broad implications for the design of symbol sets. An attempt was made to model information access with this class of display.

Remington, Roger↗

Combining Speed Information Across Space

We used speed discrimination tasks to measure the ability of observers to combine speed information from multiple stimuli distributed across space. We compared speed discrimination thresholds in a classical discrimination paradigm to those in an uncertainty/search paradigm. Thresholds were measured using a temporal two-interval forced-choice design. In the discrimination paradigm, the n gratings in each interval all moved at the same speed and observers were asked to choose the interval with the faster gratings. Discrimination thresholds for this paradigm decreased as the number of gratings increased. This decrease was not due to increasing the effective stimulus area as a control experiment that increased the area of a single grating did not show a similar improvement in thresholds. Adding independent speed noise to each of the n gratings caused thresholds to decrease at a rate similar to the original no-noise case, consistent with observers combining an independent sample of speed from each grating in both the added- and no-noise cases. In the search paradigm, observers were asked to choose the interval in which one of the n gratings moved faster. Thresholds in this case increased with the number of gratings, behavior traditionally attributed to an input bottleneck. However, results from the discrimination paradigm showed that the increase was not due to observers' inability to process these gratings. We have also shown that the opposite trends of the data in the two paradigms can be predicted by a decision theory model that combines independent samples of speed information across space. This demonstrates that models typically used in classical detection and discrimination paradigms are also applicable to search paradigms. As our model does not distinguish between samples in space and time, it predicts that discrimination performance should be the same regardless of whether the gratings are presented in two spatial intervals or two temporal intervals. Our last experiment largely confirmed this prediction.

Verghese, Preeti↗

Combining Speed Information Across Space

We used speed discrimination tasks to measure the ability of observers to combine speed information from multiple stimuli distributed across space. We compared speed discrimination thresholds in a classical discrimination paradigm to those in an uncertainty/search paradigm. Thresholds were measured using a temporal two-interval forced-choice design. In the discrimination paradigm, the n gratings in each interval all moved at the same speed and observers were asked to choose the interval with the faster gratings. Discrimination thresholds for this paradigm decreased as the number of gratings increased. This decrease was not due to increasing the effective stimulus area as a control experiment that increased the area of a single grating did not show a similar improvement in thresholds. Adding independent speed noise to each of the n gratings caused thresholds to decrease at a rate similar to the original no-noise case, consistent with observers combining an independent sample of speed from each grating in both the added- and no-noise cases. In the search paradigm, observers were asked to choose the interval in which one of the n gratings moved faster. Thresholds in this case increased with the number of gratings, behavior traditionally attributed to an input bottleneck. However, results from the discrimination paradigm showed that the increase was not due to observers' inability to process these gratings. We have also shown that the opposite trends of the data in the two paradigms can be predicted by a decision theory model that combines independent samples of speed information across space. This demonstrates that models typically used in classical detection and discrimination paradigms are also applicable to search paradigms. As our model does not distinguish between samples in space and time, it predicts that discrimination performance should be the same regardless of whether the gratings are presented in two spatial intervals or two temporal intervals. Our last experiment largely confirmed this prediction.

Verghese, Preeti↗

Surface Change Detection Using Large Footprint Laser Altimetry

Laser altimeters provide a precise and accurate method for mapping topography at fine horizontal and vertical scales. A laser altimeter provides range by measuring the roundtrip flight time of a short pulse of laser light from the laser altimeter instrument to the target surface. The range is then combined with laser beam pointing knowledge and absolute position knowledge to provide an absolute measurement of the surface topography. Newer generations of laser altimeters measure the range by recording the shape and time of the outgoing and received laser pulses. The shape of the return pulse can also provide unique information about the vertical structure of material such as vegetation within each laser footprint. Distortion of the return pulse is caused by the time-distributed reflections adding together and representing the vertical distribution of surfaces within the footprint. Larger footprints (10 - 100m in diameter) can support numerous target surfaces and thus provide the potential for producing complex return pulses. Interpreting the return pulse from laser altimeters has evolved from simple timing between thresholds, range-walk corrections, constant-fraction discriminators, and multi-stop time interval units to actual recording of the time varying return pulse intensity - the return waveform. Interpreting the waveform can be as simple as digitally thresholding the return pulse, calculating a centroid, to fitting one or more gaussian pulse-shapes to the signal. What we present here is a new technique for using the raw recorded return pulse as a raw observation to detect centimeter-level vertical topographic change using large footprint airborne and spaceborne laser altimetry. We use the correlation of waveforms from coincident footprints as an indication of the similarity in structure of the waveforms from epoch to epoch, and assume that low correlation is an indicator of vertical structure or elevation change. Thus, using vertically and horizontally geolocated waveforms as raw observables (i.e., waveforms tied to a common reference ellipsoid), we assess whether epoch-to-epoch vertical ground motion results in a decrease in the correlation of coincident waveforms over time, and whether this can be used to quantify the magnitude of the deformation. Results of computer models and an example over an area of eroded beachfront will be presented.

Blair, J. Bryan↗

Discrimination between individual dust and bioparticles using aerosol time-of-flight mass spectrometry

Ice nucleating particles (INPs) impact cloud properties and precipitation processes through their ability to trigger cloud glaciation. Dust and bioparticles are two important sources of INPs that have markedly different atmospheric loadings and ice nucleating efficiencies. In situ identification of the sources of INPs in clouds has been accomplished using single particle mass spectrometry (SPMS). However, external mixtures of dust and bioparticles present a unique challenge as they have overlapping mass spectral ion signatures, complicating their unambiguous identification. This study presents a detailed discussion of dust and bioparticle SPMS signatures, uniting data from a broad array of studies. As emphasized, the ion signals from both dust and bioparticles are highly sensitive to ionization conditions. To understand the observed variations, we characterize the mass spectral dependence of distinct dust and bioparticle samples using total positive ion intensity (TPII) as an indicator of the laser pulse energy each particle encountered. Through this analysis, a broad range of characteristic biogenic low intensity ion peaks that may be useful to distinguish bioparticles from dust became apparent and are highlighted. Insights informed by this analysis were utilized to identify bioparticles in ambient SPMS data. Ambient particles exhibiting both dust and characteristic biogenic spectral fingerprints were excluded from the bioparticle classification. Although bioparticles only made up 0.2% of all sampled particles, their abundance was moderately correlated with INP concentrations measured at 15 °C.

54 ENVIRONMENTAL SCIENCES↗

Physiological factors and optical parameters as bases of vegetation discrimination and stress analysis.

The successful application of photographic, optical-mechanical scanning, and other sensing techniques to vegetation must be based on an understanding of the biological and physical principles involved. The objective is to review the biological and optical characteristics of vegetation and to discuss how knowledge of them can support operational programs by aiding in wavelength selection, timing of missions, and discriminations between vegetation types as well as between healthy and stressed plants of the same type. Both laboratory situations, in which relatively pure spectral data are obtained, and field situations are considered. In the latter, sensor performance and background variables affect data quality.

Wiegand, C. L.↗

Design and performance of the Fermilab Constant Fraction Discriminator ASIC

Here, we present the design and performance characterization results of the novel Fermilab Constant Fraction Discriminator ASIC (FCFD) developed to readout low gain avalanche detector (LGAD) signals by directly using a constant fraction discriminator (CFD) to measure signal arrival time. Silicon detectors with time resolutions less than 30ps will play a critical role in future collider experiments, and LGADs have been demonstrated to provide the required time resolution and radiation tolerance for many such applications. The FCFD has a specially designed discriminator that is robust against amplitude variations of the signal from the LGAD that normally requires an additional correction step when using a traditional leading edge discriminator. The application of the CFD directly in the ASIC promises to be more reliable and reduces the complication of evolving time-walk corrections throughout the operational lifetime of the detector system. We will present a summary of the measured performance of the FCFD for input signals generated by internal charge injection, LGAD signals from an infrared laser, and LGAD signals from minimum-ionizing particles. The mean time response for LGAD signals with charge ranging between 5 and 26 fC has been measured to vary no more than 10ps, orders of magnitude more stable than an uncorrected leading edge discriminator based measurement, and effectively removes the need for any additional time-walk correction. The measured contribution to the time resolution from the FCFD ASIC is found to be 10ps for signals with charge above 20fC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Foliage discrimination using a rotating ladar

We present a real time algorithm that detects foliage using range from a rotating laser. Objects not classified as foliage are conservatively labeled as non-driving obstacles. In contrast to related work that uses range statistics to classify objects, we exploit the expected localities and continuities of an obstacle, in both space and time. Also, instead of attempting to find a single accurate discriminating factor for every ladar return, we hypothesize the class of some few returns and then spread the confidence (and classification) to other returns using the locality constraints. The Urbie robot is presently using this algorithm to descriminate drivable grass from obstacles during outdoor autonomous navigation tasks.

Autonomous navigation range robots↗

Gamma-ray imaging of Np-237 metal using an organic glass imager

Neutron and gamma-ray imaging systems are deployed within the field of nuclear safeguards for the detection and localization of special nuclear materials and other materials of interest. 237 Np is one of these materials of interest due its presence in spent nuclear fuel and potential for use in nuclear weapons when purified. Here, for the first time, a 6 kg neptunium sphere (98.8 wt% 237 Np) was measured using a dual-particle imager, from the University of Michigan, consisting of organic glass and inorganic scintillators. The novel composition of organic glass scintillator was recently developed at Sandia National Labs and has been used in particle imaging systems due to its time resolution and particle discrimination capabilities. Gamma-ray energy spectra from single and coincident events were extracted and the sequencing of Compton scatter and photoelectric absorption gamma-ray events was used to generate images using simple backprojection. The emissions of interest in this work are the 312 keV and 416 keV gamma rays from 233 Pa, a daughter isotope from the neptunium decay series. The results of this work show that there is close agreement between the true source location in angular space and the converged location from the gamma ray images created using the system. The gamma spectroscopy from single and coincident events also identified the characteristic emission from the daughter isotope and could be used to assist with the identification of 237 Np. Furthermore, successful localization of the source with 5 s of data demonstrates the practical application of the imaging system for imaging and detection of material in weapons-useable quantities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel imaging technique for α-particles using a fast optical camera

A new imaging technique forα-particles using a fast optical camera focused on a thin scintillator is presented. Asα-particles interact in a thin layer of LYSO fast scintillator, they produce a localized flash of light. Furthermore, the light is collected with a lens to an intensified optical camera, Tpx3Cam, with single photon sensitivity and excellent spatial & temporal resolutions. The interactions of photons with the camera is reconstructed by means of a custom algorithm, capable of discriminating single photons using time and spatial information

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prototype reactor-antineutrino detector based on 6 Li-doped pulse-shape-discriminating plastic scintillator

An aboveground 60-kg reactor-antineutrino detector prototype, comprising a two-dimensional array of 36 6 ⁢Li-doped pulse-shape-sensitive plastic scintillator bars, is described. Each bar is 50 cm long with a square cross section of 5.5 cm. Doped with 6 ⁢Li at 0.1% by mass, the detector is capable of identifying correlated energy depositions for the detection of reactor antineutrinos via the inverse-𝛽-decay (IDB) reaction. Each bar is wrapped with a specular reflector that directs photons toward photomultiplier tubes mounted at both ends of the bar. Here, this paper highlights the construction, key features, and main performance characteristics of the system. The system, which relies on multiple observables such as pulse-shape discrimination, energy, position, and timing, is capable of detecting IBD-like neutron-correlated backgrounds, long-lived decay chains, and cosmogenic isotopes.

Physics↗

Photon-to-Digital Converters for Neutron Imaging Instruments (Final Report)

Oak Ridge National Laboratory (ORNL) collaborated with the Université de Sherbrooke (UdeS) to design a modular and scalable tile of innovative digital photodetectors called Photon-to-Digital Converters (PDC) and the required subsystems to demonstrate the feasibility of large area single-photon detectors to support high-resolution, depth-of-interaction, fast neutron radiography based on scintillation detectors. The goal is to demonstrate the advantages of using PDC over conventional Silicon Photomultiplier (SiPM) for neutron imaging systems. The basic building blocks of analog SiPM and PDC are Single-Photon Avalanche Photodiodes (SPAD). The main difference between conventional SiPMs and PDCs, is in the fact that analog SiPMs sum the charge produced by individual SPAD passively, while in PDCs each SPAD is read out individually by an active electronic circuit. Hence, PDCs provide a direct photon-to-bit conversion where a logic “1” means that there was a detection in a given SPAD. Conversely, an analog SiPM requires a sophisticated preamplifier (current amplifiers or transimpedance amplifier) followed by a shaping amplifier and an analog-to-digital converter. Moreover, since the charge from each SPAD varies slightly, the passive sum of the analog SiPM will have signal fluctuations for the same amount of photon detected. This is one of many issues that is completely eliminated by individual one-to-one SPAD read out in PDCs. The large area required for scintillator readouts for neutron imaging is such that the output capacitance of a large area of SiPM arrays is very high. This creates a burden on the signal-to-noise optimization with respect to the power budget. For PDC, the power consumption is dictated by rate of the incident photon flux, or in photon-starved environments, the dark noise rate of the SPAD array. In other words, the power consumption in the absence of events is extremely low. Hence, the power consumption of a PDC read out system is much lower than its analog counterpart. Further, the large SiPM capacitance may introduce signal distortions on the scintillator fast rise or decay time with undesired effects on timing and pulse shape discrimination. The problem is absent in PDCs, as their readout is independent on device capacitance. UdeS is the world leader in 3D vertical integration of frontside illuminated SPAD arrays over CMOS readouts. These capabilities allow future production of “3D PDC” with maximum photosensitive fill factor and electronic functionalities tailored to the application. UdeS' vast knowledge of SPADs and CMOS design made the team an ideal collaborator in the development of large area high-resolution fast neutron radiography.

42 ENGINEERING↗