Search NASA⌕ Search

SEARCH · Search NASA

Results for “TIME RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Optical pulse timing resolution

This correspondence evaluates the performance of the maximum likelihood (ML) and several suboptimal arrival time estimators for optical pulses. The performance analysis of a 'sliding window' counter followed by a threshold detector is achieved by deriving an expression for the first-crossing density of the output of the counter.

Lee, G.↗

High time-resolution imaging with the MAMA detector systems

Current uses of the MAMA detector which utilize the photon time-tagging capabilities of these detectors are reported. These applications currently include image stabilization by means of post-processing corrections of platform drift and speckle interferometry. The initial results of a sounding rocket experiment to obtain UV images of NGC 6240 and results from speckle interferometry of Neptune's moon Triton are presented.

Morgan, Jeffrey S.↗

Few-femtosecond time resolution in optically pumped hard X-ray scattering at a free-electron laser

Capturing chemical dynamics in real time is a central goal of ultrafast science, necessitating measurements fast enough to track atomic motion on few-femtosecond timescales with high precision. We present time-resolved hard X-ray scattering that meets these criteria by combining 7 fs full-width at half maximum (FWHM) near-infrared laser pulses with sub10 fs FWHM hard X-ray pulses from a free-electron laser. Using heavy water’s electronic response to strong-field ionization as a benchmark, we achieve a sub-8 fs FWHM instrument response function. These optical pump X-ray probe measurements enable direct observation of chemical dynamics with angstrom spatial and few-fs temporal resolution.

Weckwerth, Eleanor [Stanford University, CA (Unite↗

Improving the Time Resolution of Hyper-Spectral Infrared Sounding Observations With Trajectory Enhancement

Low Earth orbit (LEO) hyper-spectral infrared (IR) sounders have significant potential for characterizing the complex evolution of thermodynamic environments favorable for convective initiation and ongoing convection. The snapshots at fixed local times are unable to provide the temporal resolution needed to resolve the rapidly evolving convective environment. A novel methodology using trajectory modeling coupled with satellite soundings was developed to create proximity soundings near NCEI Storm Events to investigate differences in severe weather environments (Kalmus et al., 2019, https://doi.org/10.1175/MWR-D-18-0055.1). This methodology was recently extended to entire satellite swaths forward in time up to six hours into the future and was evaluated during NOAA’s Hazardous Weather Testbed (HWT) in a quasi-operational setting (Kahn et al., 2023, https://doi.org/10.1175/WAF-D-22-0204.1). This methodology is based on parcel forward-trajectory calculations from the satellite observing time to recreate future soundings of temperature and moisture at regularly gridded intervals in space and time. Using coincident Multi-Radar Multi-Sensor (MRMS) rainfall estimates, we show that convective available potential energy (CAPE) is increased and convective inhibition (CIN) is decreased at times and locations where convection initiated. This methodology was evaluated with ERA5 data sampled to mimic the satellite observing swaths (Richardson et al., 2023, https://doi.org/10.5194/egusphere-2023-97). Approximately 60–90% of the temporal and spatial variability in temperature and humidity is explained by parcel advection using trajectory modeling. This method will be applied to the multi-decadal LEO satellite record and could be used to examine capabilities of future satellite missions such as the GeoXO mission.

Emily Berndt↗

A simple technique for high resolution time domain phase noise measurement

A new time domain phase comparator is described. The device uses a novel technique to allow time domain phase measurements to be made with period and time interval counters without the use of offset reference oscillators. The device uses a single reference oscillator and allows measurements with a phase resolution greater than the noise floor of the reference. Data is presented showing a phase resolution of 0.02ps at 5 MHz with a crystal reference. The device has application in measuring the phase stability of systems where approximate phase quadrature can be maintained.

Reinhardt, V. S.↗

Direct picosecond time resolution of unimolecular reactions initiated by local mode excitation

Attention is given to the first results of direct, picosec measurements of the Delta-nu(OH) 5 local mode transition of H2O2. These time-resolved studies yield a direct measure of the unimolecular dissociation rate, and furnish a lower limit for the rate of energy redistribution from the OH stretch to the O-O reaction coordinate. The data thus determined may be used to ascertain the domain of validity for statistical unimolecular reaction rate theories.

Scherer, N. F.↗

High time resolution observation of the transient event of 5 March 1979

The detection of an intense gamma ray burst with the monitor proportional counter on the HEAO 2 spacecraft is discussed with particular emphasis on the measurement of the time of onset of the event. Based on the mean observed counting rate in the burst and assuming a sharp rise, the uncertainty in the burst onset is found to be + or - 220 microseconds. The time of occurrence was 57124.826908 + or - 0.000220 s UT on March 5, 1979, and the location of the HEAO 2 satellite at this time was latitude 22.15 deg, longitude -27.60 deg at an altitude of 525.0 km.

Weisskopf, M. C.↗

The BATSE Gamma-Ray Burst Spectral Catalog: High Time Resolution Spectroscopy of Bright Bursts Using High Energy Resolution Data - 1

This is the first in a series of gamma-ray burst spectroscopy catalogs from the Burst And Transient Source Experiment (BATSE) on the Compton Gamma Ray Abstract: Observatory, each covering a different aspect of burst phenomenology. In this paper, we present time-sequences of spectral fit parameters for 156 bursts selected either for their high peak flux or fluence.

Preece, Robert D.↗

IDE spatio-temporal impact fluxes and high time-resolution studies of multi-impact events and long-lived debris clouds

The purpose of the Interplanetary Dust Experiment (IDE) on the Long Duration Exposure Facility (LDEF) was to sample the cosmic dust environment and to use the spatio-temporal aspect of the experiment to distinguish between the various components of the environment: zodiacal cloud, beta meteoroids, meteor streams, interstellar dust, and orbital debris. It was found that the introduction of precise time and even rudimentary directionality as co-lateral observables in sampling the particulate environment in near-Earth space produces an enormous qualitative improvement in the information content of the impact data. The orbital debris population is extremely clumpy, being dominated by persistent clouds in which the fluxes may rise orders of magnitude above the background. The IDE data suggest a strategy to minimize the damage to sensitive spacecraft components, using the observed characteristics of cloud encounters.

Mulholland, J. Derral↗

On the acceleration of ions by interplanetary shock waves. 3: High time resolution observations of CIR proton events

Observations within + or - 3 hours of corotating interaction region (CIR) shock waves of proton intensities, pitch angle distribution and crude differential energy spectra of the range of 0.6 E sub p 3.4 MeV are presented. The principle result is the evidence for the persistent flow of particles away from the shock. The observations are found to be in good agreement with the hypothesis of local interplanetary shock acceleration by the shock drift and compression mechanisms. The same set of observations strongly suggest that transit time damping does not play an important role in the acceleration of protons to 1 MeV in the immediate vicinity of CIR shocks.

Pesses, M. E.↗

Solar wind variations and geomagnetic storms - A study of individual storms based on high time resolution ISEE 3 data

Two independent methods are employed to determine the relationship between the parameter epsilon and total energy dissipation rate of the magnetosphere U sub T by selecting disturbed periods from the same data d set used by Baker et al. (1983). Specifically, four storms are examined in detail, since the accuracy of estimating U sub T is significantly improved during disturbed periods. The first method assumes that U sub T = M sub A exp.2- alpha(epsilon) where M sub A is the Alfven Mach number and alpha varies with time. The second method considers a linear, time-invariant dynamic system with epsilon as input and U sub T as output. This means that U sub T = W(asterisk)epsilon where asterisk is the convolution and W is a transfer function characteristic of the system. It is found that alpha values fluctuate mainly between 0 and -0.25. The transfer function analysis indicates that W often resembles a delta-function or a narrow rectangular impulse. Both results give the same implication (namely that U sub T is approximately equal to epsilon) and thus are consistent with the view that the magnetosphere is primarily a directly driven system during disturbed periods.

Akasofu, S.-I.↗

An ISEE 3 high time resolution study of interplanetary parameter correlations with magnetospheric activity

The coupling between the solar wind and the geomagnetic disturbances was examined using data from the ISEE-3 spacecraft at an earth-sun libration point and ground-based data. One minute data were used to avoid aliasing in determining the internal magnetospheric response to solar wind conditions. Attention was given to the cross-correlations between the geomagnetic index (AE), the total energy dissipation rate (UT), and the solar wind parameters, as well as the spatial and temporal scales on which the magnetosphere reacts to the solar wind conditions. It was considered necessary to characterize the physics of the solar wind-magnetosphere coupling in order to define the requirements for a spacecraft like the ISEE-3 that could be used as a real time monitoring system for predicting storms and substorms. The correlations among all but one parameter were lower during disturbance intervals; UT was highly correlated with all parameters during the disturbed times. An intrinsic 25-40 min delay was detected between interplanetary activity and magnetospheric response in quite times, diminishing to no more than 15 min during disturbed times.

Baker, D. N.↗

The Timepix4 analog front-end design: Lessons learnt on fundamental limits to noise and time resolution in highly segmented hybrid pixel detectors

This manuscript describes the optimization of the front-end readout electronics for high granularity hybrid pixel detectors. The theoretical study aims at minimizing the noise and jitter. The model presented here is validated with both circuit post layout simulations and measurements on the Timepix4 Application Specific Integrated Circuit (ASIC). The analog front-end circuit and the procedure to optimize the dimensions of the main transistors are described with detail. The Timepix4 is the most recent ASIC designed in the framework of the Medipix4 Collaboration. It was manufactured in 65nm CMOS process, and consists of a four side buttable matrix of 448 × 512 pixels with 55µm pitch. The analog front-end has a gain of ~36mV/ke - when configured in High Gain Mode, and ~20mV/ke - when configured in Low Gain Mode. The Equivalent Noise Charge (ENC) is ~68e - rms and ~80e - rms in High Gain Mode and in Low Gain Mode respectively. In event driven mode the incoming hits can be time stamped within a ~ 200ps time bin and the chip can deal with a maximum flux of ~ 3.6MHzmm –2 s –1 . In photon counting mode, the chip can deal with up to ~ 5GHzmm –2 s –1 . The routine designed to optimize the Timepix4 front-end is then used to analyze the performance limits in terms of jitter and noise for Charge Sensitive Amplifiers in pixel detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact single-shot electro-optic detection system for THz pulses with femtosecond time resolution at MHz repetition rates

Electro-optical detection has proven to be a valuable technique to study temporal profiles of THz pulses with pulse durations down to femtoseconds. As the Coulomb field around a relativistic electron bunch resembles the current profile, electro-optical detection can be exploited for non-invasive bunch length measurements at accelerators. We have developed a very compact and robust electro-optical detection system based on spectral decoding for single-shot longitudinal bunch profile monitoring at the European X-ray Free Electron Laser (XFEL) for electron bunch lengths down to 200 fs (rms). Apart from the GaP crystal and the corresponding laser optics at the electron beamline, all components are housed in 19 in. chassis for rack mount and remote operation inside the accelerator tunnel. An advanced laser synchronization scheme based on radio-frequency down-conversion has been developed for locking a custom-made Yb-fiber laser to the radio-frequency of the European XFEL accelerator. In order to cope with the high bunch repetition rate of the superconducting accelerator, a novel linear array detector has been employed for spectral measurements of the Yb-fiber laser pulses at frame rates of up to 2.26 MHz. In this paper, we describe all sub-systems of the electro-optical detection system as well as the measurement procedure in detail and discuss the first measurement results of longitudinal bunch profiles of around 400 fs (rms) with an arrival-time jitter of 35 fs (rms).

47 OTHER INSTRUMENTATION↗