Search NASASearch

SEARCH · Search NASA

Results for “TIME SIGNAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Modern Radar Techniques for Geophysical Applications: Two Examples

The last decade of the evolution of radar was heavily influenced by the rapid increase in the information processing capabilities. Advances in solid state radio HF devices, digital technology, computing architectures and software offered the designers to develop very efficient radars. In designing modern radars the emphasis goes towards the simplification of the system hardware, reduction of overall power, which is compensated by coding and real time signal processing techniques. Radars are commonly employed in geophysical radio soundings like probing the ionosphere; stratosphere-mesosphere measurement, weather forecast, GPR and radio-glaciology etc. In the laboratorio di Geofisica Ambientale of the Istituto Nazionale di Geofisica e Vulcanologia (INGV), Rome, Italy, we developed two pulse compression radars. The first is a HF radar called AIS-INGV; Advanced Ionospheric Sounder designed both for the purpose of research and for routine service of the HF radio wave propagation forecast. The second is a VHF radar called GLACIORADAR, which will be substituting the high power envelope radar used by the Italian Glaciological group. This will be employed in studying the sub glacial structures of Antarctica, giving information about layering, the bed rock and sub glacial lakes if present. These are low power radars, which heavily rely on advanced hardware and powerful real time signal processing. Additional information is included in the original extended abstract.

Arokiasamy, B. J.

Implementation of real-time digital signal processing systems

Special purpose hardware implementation of DFT Computers and digital filters is considered in the light of newly introduced algorithms and IC devices. Recent work by Winograd on high-speed convolution techniques for computing short length DFT's, has motivated the development of more efficient algorithms, compared to the FFT, for evaluating the transform of longer sequences. Among these, prime factor algorithms appear suitable for special purpose hardware implementations. Architectural considerations in designing DFT computers based on these algorithms are discussed. With the availability of monolithic multiplier-accumulators, a direct implementation of IIR and FIR filters, using random access memories in place of shift registers, appears attractive. The memory addressing scheme involved in such implementations is discussed. A simple counter set-up to address the data memory in the realization of FIR filters is also described. The combination of a set of simple filters (weighting network) and a DFT computer is shown to realize a bank of uniform bandpass filters. The usefulness of this concept in arriving at a modular design for a million channel spectrum analyzer, based on microprocessors, is discussed.

Narasimha, M.

Characterization of the Vectron PX-570 Crystal Oscillator for Use in Harsh Environments

Computing hardware, data-acquisition systems, communications systems, and many electronic control systems require well-controlled timing signals for proper and accurate operation. These signals are, in most cases, provided by circuits that employ crystal oscillators due to availability, cost, ease of operation, and accuracy. In some cases, the electronic systems are expected to survive and operate under harsh conditions that include exposure to extreme temperatures. These applications exist in terrestrial systems as well as in aerospace products. Well-logging, geothermal systems, and industrial process control are examples of ground-based applications, while distributed jet engine control in aircraft, space-based observatories (such as the James Webb Space Telescope), satellites, and lunar and planetary landers are typical environments where electronics are exposed to harsh operating conditions. To ensure these devices produce reliable results, the digital heartbeat from the oscillator must deliver a stable signal that is not affected by external temperature or other conditions. One such solution is a recently introduced commercial-off-the-shelf (COTS) oscillator, the PX-570 series from Vectron International. The oscillator was designed for high-temperature applications and as proof, the crystal oscillator was subjected to a wide suite of tests to determine its ruggedness for operation in harsh environments. The tests performed by Vectron included electrical characterization under wide range of temperature, accelerated life test/aging, shock and vibration, internal moisture analysis, ESD threshold, and latch-up testing. The parametric evaluation was performed on the oscillator's frequency, output signal rise and fall times, duty cycle, and supply current over the temperature range of -125 C to +230 C. The evaluations also determined the effects of thermal cycling and the oscillator's re-start capability at extreme hot and cold temperatures. These thermal cycling and restart tests were performed at the NASA Glenn Research Center. Overall, the crystal oscillator performed well and demonstrated very good frequency stability. This paper will discuss the test procedures and present details of the performance results.

Li, Jacob

Signal processor architecture for backscatter radars

Real time signal processing for backscatter radars which requires computational throughput and I/O rates is discussed. The operations that are usually performed in real time are highly repetitive simple accumulations of samples or of products of samples. The control logic does not depend on the values of the data and general purpose computers are not required for the initial high speed processing. The implications of these facts on the architectures of preprocessors for backscatter radars are explored and applied to the design of the Radar Signal Compender.

Swartz, W. E.

Hybrid model predictive control techniques for safety factor profile and stored energy regulation while incorporating NBI constraints

Abstract A novel hybrid Model Predictive Control (MPC) algorithm has been designed for simultaneous safety factor ( q ) profile and stored energy ( w ) control while incorporating the pulse-width-modulation constraints associated with the neutral beam injection (NBI) system. Regulation of the q -profile has been extensively shown to be a key factor for improved confinement as well as non-inductive sustainment of the plasma current. Simultaneous control of w is necessary to prevent the triggering of pressure-driven magnetohydrodynamic instabilities as the controller shapes the q profile. Conventional MPC schemes proposed for q -profile control have considered the NBI powers as continuous-time signals, ignoring the discrete-time nature of these actuators and leading in some cases to performance loss. The hybrid MPC scheme in this work has the capability of incorporating the discrete-time actuator dynamics as additional constraints. In nonlinear simulations, the proposed hybrid MPC scheme demonstrates improved q -profile+ w control performance for NSTX-U operating scenarios.

Physics

On Road Testing Data

This dataset provides the following on road testing data: - Videos - In-vehicle dash camera videos during different testing scenarios. - Signal controller data - NTCIP log data and processed signal timing data from the corresponding signal controllers - Vehicle data - Vehicle data recorded during the testing, including GNSS, communication, CAN signals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Sub-Nyquist Distortions in Sampled One- and Two-Dimensional Signals Studied

Hardware testing frequently involves the acquisition of waveform and instrumentation signals, which are often recorded on waveform recorders, oscillographs, and video recorders. Years ago, the waveforms were viewed as analog records, as drawn by a paper strip chart pen or electron beam on a cathode ray tube screen. One of the problems in the past was that the analog electronics may not have been able to accurately display the full amplitude of a signal if the real-time signals exceeded the frequency response bandwidth of the recording device. The advent of digital oscilloscopes, waveform recorders, and video frame-grabbers solved many of the frequency response problems, though not all. A restriction on digital waveform acquisition is well known by people in the instrumentation field. Put simply, the sampling frequency must be at least twice the frequency of any signal to be sampled, or vice versa; the signals must be filtered so that none of the signal frequencies are higher than one-half the sample rate (the Nyquist Limit). Then, per Shannon's Sampling Theorem (1949, ref. 1), any sampled signal can be reconstructed for viewing on a display device. If any signals exceed the Nyquist frequency limit, error signals called aliases occur in the output display.

Williams, Glenn L.

Efficient detection of a CW signal with a linear frequency drift

An efficient method is presented for the detection of a continuous wave (CW) signal with a frequency drift that is linear in time. Signals of this type occur in transmissions between any two locations that are accelerating relative to one another, e.g., transmissions from the Voyager spacecraft. We assume that both the frequency and the drift are unknown. We also assume that the signal is weak compared to the Gaussian noise. The signal is partitioned into subsequences whose discrete Fourier transforms provide a sequence of instantaneous spectra at equal time intervals. These spectra are then accumulated with a shift that is proportional to time. When the shift is equal to the frequency drift, the signal to noise ratio increases and detection occurs. Here, we show how to compute these accumulations for many shifts in an efficient manner using a variety of Fast Fourier Transformations (FFT). Computing time is proportional to L log L where L is the length of the time series.

Swarztrauber, Paul N.

GERMcode: A Stochastic Model for Space Radiation Risk Assessment

A new computer model, the GCR Event-based Risk Model code (GERMcode), was developed to describe biophysical events from high-energy protons and high charge and energy (HZE) particles that have been studied at the NASA Space Radiation Laboratory (NSRL) for the purpose of simulating space radiation biological effects. In the GERMcode, the biophysical description of the passage of HZE particles in tissue and shielding materials is made with a stochastic approach that includes both particle track structure and nuclear interactions. The GERMcode accounts for the major nuclear interaction processes of importance for describing heavy ion beams, including nuclear fragmentation, elastic scattering, and knockout-cascade processes by using the quantum multiple scattering fragmentation (QMSFRG) model. The QMSFRG model has been shown to be in excellent agreement with available experimental data for nuclear fragmentation cross sections. For NSRL applications, the GERMcode evaluates a set of biophysical properties, such as the Poisson distribution of particles or delta-ray hits for a given cellular area and particle dose, the radial dose on tissue, and the frequency distribution of energy deposition in a DNA volume. By utilizing the ProE/Fishbowl ray-tracing analysis, the GERMcode will be used as a bi-directional radiation transport model for future spacecraft shielding analysis in support of Mars mission risk assessments. Recent radiobiological experiments suggest the need for new approaches to risk assessment that include time-dependent biological events due to the signaling times for activation and relaxation of biological processes in cells and tissue. Thus, the tracking of the temporal and spatial distribution of events in tissue is a major goal of the GERMcode in support of the simulation of biological processes important in GCR risk assessments. In order to validate our approach, basic radiobiological responses such as cell survival curves, mutation, chromosomal aberrations, and representative mouse tumor induction curves are implemented into the GERMcode. Extension of these descriptions to other endpoints related to non-targeted effects and biochemical pathway responses will be discussed.

Kim, Myung-Hee Y.

Measurement system

A measurement system is described for providing an indication of a varying physical quantity represented by or converted to a variable frequency signal. Timing pulses are obtained marking the duration of a fixed number, or set, of cycles of the sampled signal and these timing pulses are employed to control the period of counting of cycles of a higher fixed and known frequency source. The counts of cycles obtained from the fixed frequency source provide a precise measurement of the average frequency of each set of cycles sampled, and thus successive discrete values of the quantity being measured. The frequency of the known frequency source is made such that each measurement is presented as a direct digital representation of the quantity measured.

Turner, J. W.

Pulsar Movement Animation and its Corresponding Signal Visualization for Timing Source

The global positioning system, widely used for synchronization in energy systems, faces vulnerabilities, while Pulsars—natural cosmic clocks—offer long-term stability as potential backup timing sources. Existing research lacks sufficient exploration of Pulsar signal animation under astrophysical factors, limiting practical applications. This study establishes a mathematical model based on the rotation dynamics of dual-beam Pulsars and implements dynamic signal visualization through MATLAB. The model dynamically illustrates the relative motion between Pulsar beams and observers via timeline calculations, beam intensity modeling, and rotation matrix derivation. A case study on the millisecond Pulsar J1939+2134 reveals that observer angles influence signal peak timing, while beam widths determine signal duration, highlighting the critical role of parameter calibration for timing accuracy. Open-source code and animation results are publicly shared, providing tools for interdisciplinary research. This study validates the feasibility of Pulsar-based timing in energy systems, offering new insights to enhance synchronization robustness.

Wu, Ori [ORNL] (ORCID:0000000326723410)

Seamless Data-Rate Change Using Punctured Convolutional Codes for a Time-Varying Signal-to-Noise Ratio

In a time-varying signal-to-noise-ratio (SNR) environment, symbol rate is changed to maximize data return. However, the symbol-rate changes may cause the receiver symbol loop to lose lock, thus losing real-time data. We propose an alternate way of varying the data rate in a seamless fashion by puncturing the convolutionally encoded symbol stream and transmitting the punctured encoded symbols with a constant symbol rate. We systematically searched for good puncturing patterns for the Galileo (14,1/4) convolutional code and changed the data rates by using the punctured codes to match the Galileo SNR profile of November 9, 1997. We concluded that this scheme reduces the symbol-rate changes from 9 to 2 and provides a larger data return and a higher symbol SNR during most of the day.

SNR

Some services of the Time and Frequency Division of the National Bureau of Standards

The Time and Frequency Division of the National Bureau of Standards (NBS) provides several services to the general public. The radio broadcasts of WWV, WWVH, and WWVB supply reliable, unambiguous time signals to many users. The NBS telephone time-of-day service attracts several hundreds of thousands of calls each year. Periodically, the NBS provides courses on specific topics relating to time and frequency technology. In addition to numerous technical papers published each year, the NBS has prepared the first volume of a comprehensive monograph on time and frequency. The results of research in the Time and Frequency Division of the NBS have had significant impact. An active TV time system capable of serving most of the U.S. currently awaits a ruling by the FCC on a petition filed last year on behalf of the NBS by the Department of Commerce. Three more recent developments are: (1) a TV frequency comparator (patent applied for); (2) a method to perform an independent (absolute) frequency evaluation of commercial cesium beam oscillators; and (3) a method of removing one source of frequency drift in commercial cesium beam oscillators.

Barnes, J. A.

Real-Time Simulation Clock

Fiber-optic network delivers time signals to widely separated simulator sites. Real-time digital flight simulation used to support variety of research programs. Majority of research involves man-in-the-loop simulation requiring interconnection of digital computers, simulation cockpits, control consoles, graphics subsystems, and related equipment. Real-time simulation subsystem consists of several CYBER(R) computers and over 20 simulation sites. Allows for several simultaneous simulation jobs on one CYBER(R) as well as any combination of sites in each integrated simulation job.

Bennington, Donald R.

An electronic circuit that detects left ventricular ejection events by processing the arterial pressure waveform

An electronic circuit for processing arterial blood pressure waveform signals is described. The circuit detects blood pressure as the heart pumps blood through the aortic valve and the pressure distribution caused by aortic valve closure. From these measurements, timing signals for use in measuring the left ventricular ejection time is determined, and signals are provided for computer monitoring of the cardiovascular system. Illustrations are given of the circuit and pressure waveforms.

Gebben, V. D.