Automated Gold Nanorod Spectral Morphology Analysis Pipeline

The development of a colloidal synthesis procedure to produce nanomaterials with high shape and size purity is often a time-consuming, iterative process. This is often due to quantitative uncertainties in the required reaction conditions and the time, resources, and expertise intensive characterization methods required for quantitative determination of nanomaterial size and shape. Absorption spectroscopy is often the easiest method for colloidal nanomaterial characterization. However, due to the lack of a reliable method to extract nanoparticle shapes from absorption spectroscopy, it is generally treated as a more qualitative measure for metal nanoparticles. This work demonstrates a gold nanorod (AuNR) spectral morphology analysis tool, called AuNR-SMA, which is a fast and accurate method to extract quantitative structural information from colloidal AuNR absorption spectra. To demonstrate the practical utility of this model, we apply it to three distinct applications. First, we demonstrate this model's utility as an automated analysis tool in a high-throughput AuNR synthesis procedure by generating quantitative size information from optical spectra. Second, we use the predictions generated by this model to train a machine learning model to predict the resulting AuNR size distributions under specified reaction conditions. Third, we apply this model to spectra extracted from the literature where no size distributions are reported and impute unreported quantitative information on AuNR synthesis. This approach can potentially be extended to any other nanocrystal system where absorption spectra are size dependent, and accurate numerical simulation of absorption spectra is possible. In addition, this pipeline could be integrated into automated synthesis apparatuses to provide interpretable data from simple measurements, help explore the synthesis science of nanoparticles in a rational manner, or facilitate closed-loop workflows.

36 MATERIALS SCIENCE↗

Gear Test Assembly - Experimental Testing and Analysis of Gears and Bearings - FY2026

The Gear Test Assembly (GTA) is an experimental test apparatus built and installed in the Mechanisms and Engineering Test Loop (METL) at Argonne National Laboratory (ANL). While designed to accommodate a variety of components intended for use in advanced compact in-vessel transfer machine, the focus of GTA been the testing of large radial spur gears. The performance of the components used in GTA motivates the choices made in the design, components, and material choices for the forthcoming METL test articles; the Gripper Test Assembly (GrTA), and the Bearing Test Assembly (BTA). To date, GTA has completed nine experimental testing campaigns and achieved over 21 million revolutions under prototypic sodium fast reactor loads and operating conditions. This report provides an overview and results for the two most recent experiments Campaign #8 and Campaign #9. `Campaign #8 was the first campaign to make use of a set of nickel alloy radial spur gears, made from Hastelloy C-22HS, and combined with heat-treated tapered roller bearings. The bearings and torque profile used allowed Campaign #8 to be directly compared with Campaign #1 where Inconel 718 gears were used instead. Campaign #8 attained 1,058,880 shaft revolutions within 23% of the 1,314,855 revolutions achieved in Campaign #1. These results demonstrate that the heat-treated tapered roller bearings show consistent increased lifetimes, approximately three times longer than for non heat-treated taper rollers, and that the particular material of the gear does not play a substantial role in performance. Similar to Campaign #7 where bearing failure resulted in fragmentation and transport of bearing material into the gear teeth led to tooth damage in the Inconel gears, a similar process led to the damage of the Hastelloy gears. Subsequent NDE analysis showed that the damage was only limited to the tooth surface and does not extend into the gear interiors. Based on the NDE reports, the Hastelloy gears can be reconditioned and put back into service for future campaigns as was done for the Inconel gears. Reconditioned Inconel 718 gears damaged in Campaign #7 were returned to service in Campaign #9 and paired with non heat-treated tapered roller bearings. In Campaign #9 a novel set of operating conditions were implemented whereby the gears and bearings were cycled between hot, submerged refueling conditions where fuel handling operations occurred and cold, dry, and inert conditions where the sodium was drained and the vessel was allowed to cool simulating long, ex-vessel storage of the fuel handling machine. A total of eight of these operating cycles were achieved before a bearing failure occurred after the accumulation of 475,692 shaft revolutions were achieved. During Campaign #9, one of the drive motors was damaged and over the course of a 240 day standby period, the entire GTA drive system was upgraded from a 480VAC system to a 240VAC system that provided the opportunity to consolidate wall-space in the METL facility and provide more space for additional test articles being installed in the coming year. The over 475,000 shaft revolutions achieved in Campaign #9 eclipses the previous record for lifetime of non heat-treated tapered roller bearings held by Campaign #3 of 392,000 shaft revolutions. Further analysis and future campaigns hope to shed light on the cause of this approximately 17% increase in lifetime.

42 ENGINEERING↗

A New Measurement of the Neutron Electric Form Factor with the Super Bigbite Spectrometer Apparatus

Protons and neutrons, collectively known as nucleons, make up the nuclei at the core of atoms which form our world. The nucleon has been under intensive study for over 100 years, and yet we still do not fully understand the internal dynamics which govern properties like its spin or its mass-which contributes to almost all of the visible mass in the universe. These dynamics are governed by quantum chromodynamics(QCD), the predictions of which are experimentally tested at high energy accelerator facilities such as Jefferson Lab. TheGEN-II experiment (E12-09-016) is one such experiment. GEN-II is part of the Super Bigbite Spectrometer (SBS) experimental form factor pro gramme taking place in Hall A at Jefferson Lab, which aims to make precision measurements of the nucleon electromagnetic form factors(EMFFs)at record high values of squared four momentum transfer ¿2. EMFFs describe the electric and magnetic moment distributions within the nucleon. They can be measured through elastic electron scattering off the nucleon, and describe the recoil response of the target nucleon at a given energy scale. GEN-II is a double polarized semi-exclusive beam target asymmetry (BTA) experiment, seeking to measure the electric form factor of the neutron,¿¿ ¿,at three new values of squared four-momentum transfer¿2 =2.92,6.74and9.82GeV². The latter two points being at record high ¿2. The form factor is determined through measuring the BTA of quasielliptical scattering of a neutron from a polarized nuclear target. The experiment utilized the CEBAF accelerator to produce longitudinally polarized electrons up to ~85% polarization, which were scattered off neutrons within a novel polarized helium-3 (³He) target. This new polarized ³He target was employed by building on the technology of its precursors which existed in similar preceding experiments. This target was designed to operate at the high luminosities typical of Hall A, and reached a record breaking combination of polarization and beam intensity known as figure of merit, three times larger than those predecessors. The SBS collaboration designed and constructed two brand new high acceptance spectrometers for these experiments, an electron arm named Bigbite (BB) and a hadron arm named Super Bigbite. Both spectrometers featured a large acceptance EM dipole magnet, and complementary detector systems. The electron arm contained gaseous electronmultipliers(GEMs) which were used for high precision tracking of the scattered electrons, a heavy gas cherenkov (GRINCH) which was used for PID between electrons and pions, a plastic i ii scintillator timing hodoscope to provide high resolution timing of the start of events, and a pair of EM calorimeters (BBCal) which provided energy measurements of detected particles, and provided the experimental trigger. The hadron arm also contained a system of GEMs which will be utilized for future SBS experiments, and a hadron calorimeter designed to provide position, timing and energy measurements of the recoiling nucleon. The calibration of all detector subsystems, beam and target data is discussed, with a focus on novel timing calibrations to the hodoscope and hadron calorimeter. An analysis of selecting quasielliptical events and suppressing background contributions from a number of sources which contaminate the final event sample is given. The largest irreducible backgrounds are found to be from misidentified protons, timing accidentals and inelastic events. The physical asymmetry is measured and used to extract a value for the form factor ratio ¿¿ ¿/¿¿ ¿. High precision ¿2 data for ¿¿ ¿ is used to then extract ¿¿ ¿. This work finds at ¿2 = 2.92 GeV2 that ¿¿ ¿ = 0.0129+0.0019 -0.0020. This result is in statistical agreement with existing fits to world data, and predictions from the constituent quark model and Dyson–Schwinger equations, in this region of ¿2.

Penman, Gary [Univ. of Glasgow, Scotland (United K↗

Outgassing measurements of bare and magnetite-coated low-carbon steel vacuum chambers

The outgassing properties of bare and magnetite-coated AISI 1020 low-carbon steel vacuum chambers were evaluated to establish material selection criteria for extreme high vacuum applications, namely, to explore the possibility of using these materials to build next-generation spin-polarized photoelectron guns. Water outgassing measurements using the throughput method revealed that the magnetite-coated chamber exhibited five times lower outgassing at room temperature prior to baking, but this advantage disappears after 80 °C baking. Hydrogen outgassing measurements demonstrated significant differences after intensive heat treatment: the bare low-carbon steel vacuum chamber achieved a specific outgassing rate of 9.6 × 10 −16 Torr L s −1 cm −2 after 400 °C/50 h bake plus additional heat treatment at lower temperatures, 25 times lower than the magnetite-coated low-carbon steel chamber. Residual gas analysis showed >99% hydrogen composition after heat treatment for both materials, with carbon species below detection limits for bare low-carbon steel versus 0.8% for magnetite-coated surfaces. These measurements indicate that properly conditioned bare low-carbon steel can achieve the <10 −12 Torr pressures required for next-generation spin-polarized photogun applications. In conclusion, the paper includes various analysis techniques intended to explain observed behaviors: isotherm analysis of pump-down plots, Arrhenius analysis of hydrogen outgassing rate data, and residual gas composition tracking.

Adsorption isotherm↗

State-to-State Molecular Reactions in the Ultracold Regime (Final Scientific Report)

We have achieved the proposed goal to experimentally probe the AB + CD and AB + C types of reactions with state-to-state resolution, which we also compared to advanced theoretical calculations to help elucidate the role of quantum mechanics in the processes of bond breakage and formation. Our approach uses reactants that are prepared at ultracold temperatures (< 1µK) such that the quantum effects of translational motion are an important factor. Specific example reactions, including the potassium-rubidium metathesis reaction KRb + KRb → K 2 + Rb 2 as well as the atom exchange reaction Rb + KRb → Rb2 + K, are chosen because the technology of quantum internal and motional state control of these types of molecules is particularly advanced. The results for the entire funding period are fruitful. For the majority of this grant, we have constructed a one-of-the-kind quantum degenerate gas apparatus that integrates ion detection and velocity map imaging capabilities, allowing us to explore the KRb + KRb → K 2 + Rb 2 bimolecular reaction in detail. Specifically, we first verified such a reaction indeed proceed at ultracold temperatures by direct detection of reaction products. We then mapped out the complete product state distribution, which was compared to a state-counting model based on statistical theory. Our results show an overall agreement with the statistical state counting model, but also reveal several deviating state-pairs. An exact quantum calculation for molecule-molecule collisions, that is needed to understand these deviations, is however beyond the current state-of-the-art. Beside scrutinizing the reaction products, we also directly observe the reaction intermediate complex, which was quite a surprise to us. The intermediate complexes are long-lived and can interact with the inferred light that we use to trap the ultracold gas. After molecule-molecule collisions, we then explored the more theoretically tractable Rb + KRb reaction, which is endothermic. Surprisingly, we observed an exceedingly long-lived KRb$^*_2$ collisional complexes, with our experimentally measured complex lifetime deviating from conventional theoretical calculations by five orders of magnitude. This discrepancy has motivated many explorations of possible underlying causes, though no model yet captures this phenomenon completely. In the final year and the work that continues today, we extend upon these atom-molecule collision experiments to explore the origin of the long-lived KRb$^*_2$ complex lifetime and develop means to control the outcome of the reaction complex. The 5-year funded work advanced our understanding of chemical reactions at the lowest possible temperatures and at the same time opened up many new questions that are beyond our initial imaginations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Side-by-side evaluation of the outgassing rate and ultimate pressure achieved inside tubes made of low-carbon and stainless steel

The hydrogen outgassing rate of a vacuum chamber made of AISI 1020 low-carbon steel was found to be notably smaller than a similar chamber made of AISI 316L stainless steel following heat treatment at 150 °C. When the chambers were baked at 400 °C, the outgassing rate of the 1020 low-carbon steel chamber was approximately 2000 times smaller than that of the 316L stainless-steel chamber. After quantifying hydrogen outgassing rates, vacuum chambers made of 1020 low-carbon steel and 316L stainless steel were heated for a prescribed duration and then pumped with an ion pump and nonevaporable getter pump to reach “ultimate pressure.” The 1020 low-carbon steel chamber reached lower pressures than the 316L stainless-steel chamber. Monte Carlo simulation predictions using the measured hydrogen outgassing rates are in good agreement with the ultimate pressure measurements. Finally, our measurements indicate that low-carbon steel can provide pressures within the extreme high vacuum range (<7.5 × 10 -13 Torr) if care is taken to minimize the surface area contribution from stainless steel.