At least 73 records · Page 4

PACE OCI Pre-launch ETU Spectral Characterization and Performance

The Ocean Color Instrument (OCI) is the primary sensor on the upcoming Plankton, Aerosol, Cloud ocean Ecosystem (PACE) mission. OCI is a new type of sensor compared to NASA’s ocean color heritage sensors VIIRS, MODIS, and SeaWiFs. Unlike its heritage sensors, OCI has two slit grating hyperspectral spectrographs in addition to a fiber-coupled multiband filter spectrograph. The two hyperspectral spectrographs provide continuous coverage from 340nm to 885nm in the UV to NIR range. These spectrographs use programmable CCD detectors that aggregate multiple CCD pixels that can effectively provide various spectral resolutions. The fiber-coupled multiband filter spectrograph provides seven discrete spectral bands from 940nm to 2260nm. OCI completed system level testing of the Engineering Test Unit (ETU) in June 2021 at the Goddard Space Flight Center (GSFC). The ETU contains one of the slit grating spectrographs (600nm to 885nm) and the fiber-coupled spectrograph. The ETU was tested in thermal vacuum (TVAC) in February 2020 and January 2021 to assess characterization and performance compliance to design requirements. This paper presents an overview of the spectral performance of the OCI ETU for relative spectral response (RSR), integrated Out-of-Band response (IOOB), system gain, band centers, and bandwidths.

PACE↗

A Vacuum-Compatible, Spectrally Tunable, Flat Panel Uniform Source for Testing Large Aperture Earth Observation Systems

Labsphere, Inc. in conjunction with NASA GSFC and Genesis Engineering Solutions Inc., has developed an innovative, vacuum compatible, calibration spectro-radiometric illumination source with a highly uniform large-area rectangular flat panel active area. This device features a uniquely shaped diffuse integration geometry to achieve high uniformity over a large active output area while maintaining a smaller and more robust overall form-factor when compared to previous designs or integrating spheres. A new liquid-cooled hybrid quartz-tungsten (QT) and light emitting diode (LED) source module has been engineered to provide direct-in-vacuum reference illumination over the full dynamic range and spectrum of the VIIRS instrument’s optical bands during pre-launch testing. The first unit has been demonstrated to meet its requirements using ambient technology and a fully-vacuum-compatible second unit is planned to allow testing in thermal vacuum (TVAC) campaigns. This technology is flexible and capable of meeting the needs of many other instruments/missions requiring this type of test/calibration capability.

Jeffrey Holt↗

Off-Earth Servicing Component Advancement (OESCA) Flight-like Coriolis Mass Flowmeter Development

With the completion of this initial technology development effort, additional work will be required for infusion and advancement through TRL 7. The remainder of the flight-level environmental testing (electromagnetic interference and compatibility or electromagnetic interference/electromagnetic compatibility (EMI/EMC), thermal vacuum or TVAC, along with vibration and shock testing) and post-test functional checkouts will need to be completed and are currently planned as part of an awarded STMD Early Career Initiative (ECI) Project called Advancement of Exploration Components for In-Space Servicing or AXCIS. The results and reports from these additional tests during the ECI effort will complete the technology development package, advancing the TRL to 5 or 6 while providing a vendor capable of manufacturing flight units and a flight-ready design as well as lessons-learned from the environmental testing. The Coriolis flowmeter development unit would then be incorporated into a demonstration testbed system for microgravity testing to further understand how it functions and performs in a space-like environment, advancing the developed technology to TRL 6 or 7. Following this infusion path will enable NASA program(s)/proposal(s) to procure a flight-rated high accuracy Coriolis mass flowmeter for incorporation into in-space and Lunar/Martian surface spacecraft propellant resupply systems which, after successful mission use, will bring the TRL to 7+.

Amy Felt↗

Overview of Past and Future EVA Suit Testing and Training in Chamber B at NASA JSC

The Crew and Thermal System Division’s Chamber B has received an increase in demand for next generation suit testing. Chamber B is the National Aeronautics and Space Administration (NASA) Johnson Space Center’s only human-rated thermal vacuum (TVAC) chamber. Historically it was used in Gemini, Apollo, Skylab, Shuttle, and the International Space Station (ISS) suit tests. Recently, the chamber has been returned to service with new capabilities for suit testing. In 2023, The Exploration Extravehicular Mobility Unit (xEMU) underwent a 5-day, extensive thermal vacuum test that included both a full-bodied Exploration Pressure Garment Suit (xPGS) as well as a high fidelity Short xEMU. SpaceX has also used the chamber for human-in-the-loop (HITL) qualification and acceptance testing on their flight Polaris Dawn suits for the first-ever commercial extravehicular activity (EVA). Current chamber Manlock B2 upgrades include the support of two test subjects at the same time with updated chamber interface and support systems for the next generation of suits. This paper will discuss the history of spacesuit testing in the chamber, the recent testing for commercial and NASA suits, and upgrades to accommodate new test requirements.

Polaris Dawn↗

An Evaluation of NOAA-20 ATMS Instrument Pre-Launch and On-Orbit Performance Characterization

Passive microwave sounders provide the highest-impact observations ingested by major numerical weather prediction (NWP) forecast models. The Advanced Technology Microwave Sounder (ATMS), built by Northrop Grumman, Azusa, CA, USA, is the latest operational microwave sounder series being launched by the United States to provide both temperature and water vapor soundings of the atmosphere. The first ATMS was launched on the Suomi National Polarorbiting Partnership (SNPP) satellite in 2011. This article focuses on the details of the on-orbit performance characterization of the second ATMS, which launched on November 18, 2017, on the Joint Polar Satellite System-1 (JPSS-1) satellite. After successful commissioning, JPSS-1 was renamed National Oceanic and Atmospheric Administration (NOAA)-20 (N-20). We present performance characterizations from prelaunch and postlaunch tests, including the thermal vacuum (TVAC) campaign, and postlaunch activities that contribute to the radiance data products. Significant improvements were found for reflector emissivity, 1/ f noise performance, antenna beam efficiency, inter-channel noise correlation, and scan drive bearing design. New geolocation and pointing algorithms were evaluated. The N-20 ATMS has the same channel set, polarizations, scan geometry, and calibration approach as the SNPP ATMS. The N-20 ATMS meets all performance requirements with margin.

Advanced Technology Microwave Sounder (ATMS)↗

Overview of Past and Future EVA Suit Testing and Training in Chamber B at NASA JSC

The Crew and Thermal System Division’s Chamber B has received an increase in demand for next generation suit testing. Chamber B is the National Aeronautics and Space Administration (NASA) Johnson Space Center’s only human-rated thermal vacuum (TVAC) chamber. Historically it was used in Gemini, Apollo, Skylab, Shuttle, and the International Space Station (ISS) suit tests. Recently, the chamber has been returned to service with new capabilities for suit testing. In 2023, The Exploration Extravehicular Mobility Unit (xEMU) underwent a 5-day, extensive thermal vacuum test that included both a full-bodied Exploration Pressure Garment Suit (xPGS) as well as a high fidelity Short xEMU. SpaceX has also used the chamber for human-in-the-loop (HITL) qualification and acceptance testing on their flight Polaris Dawn suits for the first-ever commercial extravehicular activity (EVA). Current chamber Manlock B2 upgrades include the support of two test subjects at the same time with updated chamber interface and support systems for the next generation of suits. This paper will discuss the history of spacesuit testing in the chamber, the recent testing for commercial and NASA suits, and upgrades to accommodate new test requirements.

Human-in-the-loop↗

Volatiles Loss from Water Bearing Regolith Simulant at Lunar Environments

Permanently shadowed craters at the lunar poles contain water, ~5 wt% according to LCROSS. Interest in water for ISRU applications. Desire to 'ground truth' water using surface prospecting; e.g. Resource Prospector (RP) & RESOLVE. How to access subsurface water resources and accurately measure quantity; Excavation operations and exposure to lunar environment may affect the results A series a ground based dirty thermal vacuum tests are being conducted to better understand the subsurface sampling operations: Sample removal and transfer, Volatiles loss during sampling operations, Concept of operations, Instrumentation. This presentation covers: The capabilities of the VF-13 Thermal Vacuum Chamber (Tvac). The Resource Prospector TVAC hardware. The summary and results of 5 years of RP volatiles tests; 43 viable samples

In-situ Resource Utilization↗

NASA MSFC Lunar Surface Simulator (LSS): A Facility for Lunar Relevant Environment Testing

NASA will resume crewed visits to the lunar sur-face beginning in the mid-2020s. Environmental testing is essential to developing and validating the hardware that will enable a sustained presence on the lunar surface. Lunar dust is one of the most pressing challenges that threatens the longevity of mechanical systems as well as the health of astronauts living and working on the Moon. Facilities that allow large pieces of hard-ware to be exposed to both lunar dust and the temperature and vacuum of the lunar environment are invaluable to the agency as well as to the broader community of international, academic, and industry partners with which the agency collaborates. Marshall Space Flight Center has out-fitted one of its largest test chambers with regolith simulant beds to create the Lunar Surface Simulator (LSS).

Relevant environment testing↗

NASA MSFC Lunar Surface Simulator (LSS): A Facility for Lunar Relevant Environment Testing

NASA will resume crewed visits to the lunar surface beginning in the mid-2020s. Environmental testing is essential to developing and validating the hardware that will enable a sustained presence on the lunar surface. Lunar dust is one of the most pressing challenges that threatens the longevity of mechanical systems as well as the health of astronauts living and working on the Moon. Facilities that allow large pieces of hardware to be exposed to both lunar dust and the temperature and vacuum of the lunar environment are invaluable to the agency as well as to the broader community of international, academic, and industry partners with which the agency collaborates. Marshall Space Flight Center has outfitted one of its largest thermal vacuum chambers with regolith simulant beds to create the Lunar Surface Simulator (LSS).

Relevant environment testing↗

Technical Capability Upgrades to the NASA Langley Research Center 8 ft. by 15 ft. Thermal Vacuum Chamber

The 8 ft. by 15 ft. thermal vacuum chamber (TVAC), housed in Building 1250 at the NASA Langley Research Center (LaRC), and managed by the Systems Integration and Test Branch within the Engineering Directorate, has undergone several significant modifications to increase testing capability, safety, and quality of measurements of articles under environmental test. Significant modifications include: a new nitrogen distribution manifold for supplying the shroud and other cold surfaces to liquid nitrogen temperatures; a new power supply and distribution system for accurately controlling a quartz IR lamp suite; a suite of contamination monitoring sensors for outgassing measurements and species identification; a new test article support system; signal and power feed-throughs; elimination of unnecessary penetrations; and a new data acquisition and control commanding system including safety interlocks. This paper will provide a general overview of the LaRC 8 ft. by 15 ft. TVAC chamber, an overview of the new technical capabilities, and will illustrate each upgrade in detail, in terms of mechanical design and predicted performance. Additionally, an overview of the scope of tests currently being performed in the chamber will be documented, and sensor plots from tests will be provided to show chamber temperature and pressure performance with actual flight hardware under test.

Thornblom, Mark N.↗

Investigating Laser Beam Welding as an In-Space Joining Technique via Thermal Vacuum and Microgravity and Vacuum Experiments

In-space joining technologies are crucial for stimulating an in-space economy and for enabling sustained space exploration by in-space manufacturing and repair of metallic structures. Compared to brazing or soldering, in-space welding (ISW) can provide highly hermetic, strong, and complex joints, potentially without introducing additional material. However, the influence of extreme temperatures, reduced pressure, and reduced gravity on ISW is not yet fully elucidated. Several efforts at NASA are investigating laser beam welding (LBW) as a joining and repair method in both thermal vacuum (TVAC) and combined vacuum & reduced gravity environments. NASA Marshall Space Flight Center (MSFC) shepherded several ISW projects in its past, including the 1973 electron beam welding on Skylab, the 1989 low-power LBW on parabolic flights, and the unflown 1990s-era In-Space Welding Experiment. Recent parabolic flights and 3 degree-of-freedom ground testing build upon this heritage. A collaboration with the Ohio State University using NASA Langley Research Center (LaRC) hardware retrofitted for LBW achieved the first high-powered laser welds under vacuum and low gravity and developed a workforce capable developing such experimental hardware. A ground testing campaign at the MSFC Flat Floor simulated fit-up and welding representative of ISW in 3 degrees of freedom to emulate microgravity effects on inertial systems. One ongoing effort is a NASA Early Career Initiative project – Lunar Assembly and Servicing by Autonomous Robotics (LASAR). Ruggedized LBW components were developed by an external partner for use in TVAC. A TVAC-rated robotic arm was procured by MSFC and used in the first known robotic laser weld where all components save the laser generator were under vacuum. NASA Johnson Space Center (JSC) is advancing supervised autonomy of ISW. NASA LaRC continues to adapt their unique snowflake joint geometry, suitable for connecting segments in trusses and other structures, to LBW. Upcoming TVAC campaigns will focus on testing extreme temperatures, proving out autonomous operations, and demonstrating weld repair. Weld inspection will occur via a non-contact nondestructive evaluation (NDE) technique – electromagnetic acoustic transduction (EMAT). Another ongoing effort based at MSFC is the DISCMAN -- DIsk-Shaped Configurable and Modular vAcuum uNit – which seeks to development a compact, modular payload that can provide a vacuum environment while in a reduced gravity condition. This payload could support multiple in-space manufacturing developmental efforts, with the first demonstration technology being LBW. Currently, the design is targeting operations in the pressurized volume of a space station, but the payload could readily be adapted to other flight platforms such as parabolic or even suborbital vehicles. LASAR elucidates the effects of temperature and vacuum on LBW while DISCMAN probes those of vacuum and gravity. Through these complementary efforts, NASA is addressing the primary challenges of ISW across the space environment while simultaneously developing and maturing technologies including robotic systems and inspection methodologies for future practical implementation on the Moon and beyond. This approach is timely, as upcoming missions requiring sustained human presence in space will depend on reliable ISW capabilities to create robust metallic joints currently unproven in the space environment and to perform repairs in situ .

hypogravity↗

SPARCS Payload Assembly, Integration, and Test Update

The Star-Planet Activity Research CubeSat (SPARCS) is a 6U CubeSat under construction that is devoted to the photometric monitoring of M stars in the far-UV (FUV) and near-UV (NUV), to measure the time-dependent spectral slope, intensity and evolution of low-mass star high-energy radiation. We report on the progress made in the assembly, integration and test of the instrument payload at Arizona State University using a custom TVAC chamber and optical stimulus that provides calibration light sources and the custom contamination control environment that the FUV demands. The payload consists of a custom 90mm clear aperture telescope developed by Hexagon/Sigma Space, combined with a dichroic plate to separate the FUV and NUV beams developed by Teledyne Acton and Materion, married with twin focal plane array cameras separately optimized for their band passes as developed by JPL.

FUV↗

A Summary of the NEXT-C Flight Thruster Proto-flight Testing

Aerojet Rocketdyne (AR), under contract to NASA Glenn Research Center, built, tested and delivered the first flight version of the NEXT-C (NASA Evolutionary Xenon Thruster – Commercial) engine system. This system is comprised of a 7 kW thruster and power processing unit which are the commercial variants of the NEXT prototype thruster and power processing unit. In addition to developing the NEXT-C engine system for potential future NASA science missions, AR is dedicated to ensuring that this propulsion system is viable for commercial users and a wider variety of commercial applications. This paper will focus on the performance of the first flight model thruster, SN001, and presents an overview of the proto-flight testing environments and data obtained. For this first flight thruster, the proto-flight test sequence involved characterizing the performance of the thruster, in addition to vibration and thermal vacuum testing of the thruster. Between each of these environmental tests, the performance of the thruster was verified, ensuring that the environmental exposures, i.e. vibration and TVAC, did not affect the thruster performance. Specifically, the proto-flight data obtained included discharge chamber, optics and neutralizer performance. Faraday probe and ExB data obtained in the regions downstream of the thruster are presented and used to calculate thrust, and therefore specific impulse and total efficiency. Lastly, data are presented showing how the centroid of the ion beam, assumed to be indicative of the thrust vector location, varies throughout the entire proto-flight test campaign. The proto-flight testing of the NEXT-C PPU is documented in a previously published paper by Bontempo4. Following the proto-flight testing of the thruster, the thruster and its PPU successfully completed a System Integrated Test (SIT) tailored to the DART Mission. After the completion of the proto-flight testing, the SN001 thruster and SN002 PPU were delivered to APL for use on the DART mission.

Ion thruster↗

Technical Capability Upgrades to the NASA Langley Research Center 6 ft. by 6 ft. Thermal Vacuum Chamber

The 6 ft. by 6 ft. thermal vacuum chamber (TVAC), housed in Building 1250 at the NASA Langley Research Center (LaRC), and managed by the Systems Integration and Test Branch within the Engineering Directorate, has undergone several significant modifications to increase testing capability, safety, and quality of measurements of articles under environmental test. Significant modifications include: a new nitrogen thermal conditioning unit for controlling shroud temperatures from -150degC to +150degC; two horizontal auxiliary cold plates for independent temperature control from -150degC to +200degC; a suite of contamination monitoring sensors for outgassing measurements and species identification; signal and power feed-throughs; new pressure gauges; and a new data acquisition and control commanding system including safety interlocks. This presentation will provide a general overview of the LaRC 6 ft. by 6 ft. TVAC chamber, an overview of the new technical capabilities, and illustrate each upgrade in detail, in terms of mechanical design and predicted performance. Additionally, an overview of the scope of tests currently being performed in the chamber will be documented, and sensor plots from tests will be provided to show chamber temperature and pressure performance with actual flight hardware under test.

Thornblom, Mark N.↗

Analytical Methodology Used To Assess/Refine Observatory Thermal Vacuum Test Conditions For the Landsat 8 Data Continuity Mission

Thermal and Fluids Analysis Workshop Silver Spring, MD NCTS 21070-15 The Landsat 8 Data Continuity Mission, which is part of the United States Geologic Survey (USGS), launched February 11, 2013. A Landsat environmental test requirement mandated that test conditions bound worst-case flight thermal environments. This paper describes a rigorous analytical methodology applied to assess refine proposed thermal vacuum test conditions and the issues encountered attempting to satisfy this requirement.

0000↗

Delta Method Application for the Correlation of IR Detector Thermal Parasitic Loads with Statistically Accurate Results

The Linear Etalon Imaging Spectral Array (LEISA) is a cryogenic IR detector that is passively cooled below 110K. LEISA is part of the L’Ralph instrument, which is going on the Lucy mission, with planned flyby’s of the Trojan asteroids around 5.5 AU. One of the primary thermal challenges is to successfully quantify each significant parasitic heat flow value with statistical certainty.Simulation of flight-like thermal environments and correlation of thermal models is an important part of this challenge, which can be critical for thermally sensitive systems such as cryogenic detectors that are passively cooled. It is common practice during TVAC to achieve several thermal balance points and then to correlate several design variables in order to achieve the closest match to all balance points tested. This approach lends itself to high levels of uncertainty in the correlated values due to the cumulative effect of absolute temperature uncertainty and differences between the sensors used for the measurement. Accuracy can be improved with the use of more accurate sensors, by calibrating all sensors with respect to each other, and by using Zero-Q methodologies, all of which add cost and complexity to the test.The Delta Method uses the difference in temperature caused by the changes in the boundary conditions to calculate heat flows and/or thermal resistances across temperature differentials. This eliminates the problem of high uncertainties with absolute temperature measurements, and yields statistically accurate results down to the sensor resolution of 1mK at < 100K, by taking the sensor’s calibration errors out of the equation. During testing, this method relies on parametric variations around an initial balance point, by varying the boundary conditions of the different parasitic heat sources. The Delta Method, as well as its application on the LEISA thermal test, will be discussed in detail.

Daniel G. Bae↗