Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tapes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

An Exact Algorithm for the Linear Tape Scheduling Problem

Magnetic tapes are often considered as an outdated storage technology, yet they are still used to store huge amounts of data. Their main interests are a large capacity and a low price per gigabyte, which come at the cost of a much larger file access time than on disks. With tapes, finding the right ordering of multiple file accesses is thus key to performance. Moving the reading head back and forth along a kilometer long tape has a non-negligible cost and unnecessary movements thus have to be avoided. However, the optimization of tape request ordering has rarely been studied in the scheduling literature, much less than I/O scheduling on disks. For instance, minimizing the average service time for several read requests on a linear tape remains an open question. Therefore, in this paper, we aim at improving the quality of service experienced by users of tape storage systems, and not only the peak performance of such systems. To this end, we propose a reasonable polynomial-time exact algorithm while this problem and simpler variants have been conjectured NP-hard. We also refine the proposed model by considering U-turn penalty costs accounting for inherent mechanical accelerations. Then, we propose a low-cost variant of our optimal algorithm by restricting the solution space, yet still yielding an accurate suboptimal solution. Finally, we compare our algorithms to existing solutions from the literature on logs of the mass storage management system of a major datacenter. This allows us to assess the quality of previous solutions and the improvement achieved by our low-cost algorithm. Aiming for reproducibility, we make available the complete implementation of the algorithms used in our evaluation, alongside the dataset of tape requests that is, to the best of our knowledge, the first of its kind to be publicly released.

Honoré, Valentin↗

Investigation of HTS Twisted Stacked-Tape Cable (TSTC) Conductor for High-Field, High-Current Fusion Magnets

The critical currents of a twisted single-tape were measured at 4.2 K in fields up to 17 T. It was confirmed that the critical current of a twisted-tape was similar to that of a flat tape in c-axis fields. Based on the single-tape critical-currents, a 40-tape (4-mm width) twisted stacked-tape cable (TSTC) conductor was experimentally evaluated at fields up to 17 T at 4.2 K. It was found that the Lorentz load degradation of the TSTC conductor was negligible at the end of a cyclic test. The TSTC cabling method has been considered to be suitable for developing a high-field high-current REBCO conductor for magnet applications as well as power transmission cables. A method to fabricate the inner legs of a D-shape toroidal field coil using a TSTC conductor has been discussed. This method allows the conductor to properly resist the transverse Lorentz load and mitigate ac loss issues by adopting a parallel-HTS-tape flat cable configuration where necessary.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Digital tape unit test facility software

Two computer programs are described which are used for the collection and analysis of data from the digital tape unit test facility (DTUTF). The data are the recorded results of skew tests made on magnetic digital tapes which are used on computers as input/output media. The results of each tape test are keypunched onto an 80 column computer card. The format of the card is checked and the card image is stored on a master summary tape via the DTUTF card checking and tape updating system. The master summary tape containing the results of all the tape tests is then used for analysis as input to the DTUTF histogram generating system which produces a histogram of skew vs. date for selected data, followed by some statistical analysis of the data.

Jackson, J. T.↗

Lunar targeting study: Lunar and planetary Ephemeris tapes

The Univac 1108 computer tape data formats are documented for the ephermeris tape generated by the Jet Propulsion Laboratory and the ephemeris tape used by the Quick Response Targeting Program (QRTP). Ephermeris tapes are used as the data source for the position and velocity components of those celestial bodies being considered in an integrated trajectory simulation program. The QRTP ephemeris tape has data only for lunar mission simulations. The JPL ephemeris tape has data for the moon and the nine planets. The ephemeris tapes, the data formats, the coordinate systems, and units are defined. The transformation from the mean-of-1950 coordinate system to the nearest mean Besselian year is given.

Green, W. G.↗

Studies on the frictional behavior of magnetic recording tapes

Methods were developed for measuring frictional forces acting on a magnetic tape in motion or at rest, as well as the extent of stick slip. The effects of factors such as temperature, humidity, kind of gaseous atmosphere, and tape speed on the frictional interaction between various tapes and heads were investigated. Results were instrumental in the selection of a tape for the Mariner Mars 1971 spacecraft. Studies are reported on the stick slip behavior of tapes and the performance of a metallic tape, compared with the usual plastic tapes.

Kalfayan, S. H.↗

Feasibility model of a high reliability five-year tape transport, volume 2

Analysis of the design features of the modularized tape transport renders a life expectancy in excess of five years. Tests performed on the tape transport were directed toward determining its performance capability. These tests revealed that the tape jitter and skew are in the range achieved by high quality digital tape transports. Guidance of the tape in the lateral sense by the use of the two hybrid crowned rollers proved to be excellent. Tracking was maintained within less than one thousandth inch (approximately 2 micrometers). The guidance capability demonstrated makes possible the achievement of the performance objective of 7.2 x 10 to the 9th power storage capability employing 1500 ft. of one inch wide tape with a packing density of 5,000 bits per inch per track on 80 tracks. Also, the machine showed excellent characteristics operating over a wide range of tape speeds. The basic design concept lends itself to growth and adaptation to a wide range of recorder requirements.

Eshleman, R. L.↗

Magnetic Tape Recording for the Eighties

The practical and theoretical aspects of state-of-the-art magnetic tape recording technology are reviewed. Topics covered include the following: (1) analog and digital magnetic tape recording, (2) tape and head wear, (3) wear testing, (4) magnetic tape certification, (5) care, handling, and management of magnetic tape, (6) cleaning, packing, and winding of magnetic tape, (7) tape reels, bands, and packaging, (8) coding techniques for high-density digital recording, and (9) tradeoffs of coding techniques.

Kalil, Ford↗

Chemistry of cometary meteoroids from video-tape records of meteor spectra

The chemistry of the cometary meteoroids was studied by closed circuit television observing systems. Vidicon cameras produce basic data on standard video tape and enable the recording of the spectra of faint shower meteors, consequently the chemical study is extended to smaller particles and we have a larger data bank than is available from the more conventional method of recording meteor spectra by photography. The two main problems in using video tape meteor spectrum records are: (1) the video tape recording has a much lower resolution than the photographic technique; (2) video tape is relatively new type of data storage in astronomy and the methods of quantitative photometry have not yet been fully developed in the various fields where video tape is used. The use of the most detailed photographic meteor spectra to calibrate the video tape records and to make positive identification of the more prominent chemical elements appearing in the spectra may solve the low resolution problem. Progress in the development of standard photometric techniques for the analysis of video tape records of meteor spectra is reported.

Millman, P. M.↗

FGGE/ERBM tape specification and shipping letter description

The Nimbus-7 FGGE/ERBM tape contains 27 ERB parameters which are extracted and reformatted from the Nimbus-7 ERB-MATRIX tape. There are four types of files on a FGGE/ERBM tape: a test file; tape-header file which describes the data set characteristics and the contents of the tape; a grid-descriptor file which contains the information of the ERB scanning channel target number and their associated latitude limits and longitude intervals; and one or more data files. A single end-of-file (EOF) tape mark is written after each file, and two EOF marks are written after the last data file on the tape.

Han, D.↗

ICI optical data storage tape

Optical data storage tape is now a commercial reality. The world's first successful development of a digital optical tape system is complete. This is based on the Creo 1003 optical tape recorder with ICI 1012 write-once optical tape media. Several other optical tape drive development programs are underway, including one using the IBM 3480 style cartridge at LaserTape Systems. In order to understand the significance and potential of this step change in recording technology, it is useful to review the historical progress of optical storage. This has been slow to encroach on magnetic storage, and has not made any serious dent on the world's mountains of paper and microfilm. Some of the reasons for this are the long time needed for applications developers, systems integrators, and end users to take advantage of the potential storage capacity; access time and data transfer rate have traditionally been too slow for high-performance applications; and optical disk media has been expensive compared with magnetic tape. ICI's strategy in response to these concerns was to concentrate its efforts on flexible optical media; in particular optical tape. The manufacturing achievements, media characteristics, and media lifetime of optical media are discussed.

Mclean, Robert A.↗

Thermal Edge-Effects Model for Automated Tape Placement of Thermoplastic Composites

Two-dimensional thermal models for automated tape placement (ATP) of thermoplastic composites neglect the diffusive heat transport that occurs between the newly placed tape and the cool substrate beside it. Such lateral transport can cool the tape edges prematurely and weaken the bond. The three-dimensional, steady state, thermal transport equation is solved by the Green's function method for a tape of finite width being placed on an infinitely wide substrate. The isotherm for the glass transition temperature on the weld interface is used to determine the distance inward from the tape edge that is prematurely cooled, called the cooling incursion Delta a. For the Langley ATP robot, Delta a = 0.4 mm for a unidirectional lay-up of PEEK/carbon fiber composite, and Delta a = 1.2 mm for an isotropic lay-up. A formula for Delta a is developed and applied to a wide range of operating conditions. A surprise finding is that Delta a need not decrease as the Peclet number Pe becomes very large, where Pe is the dimensionless ratio of inertial to diffusive heat transport. Conformable rollers that increase the consolidation length would also increase Delta a, unless other changes are made, such as proportionally increasing the material speed. To compensate for premature edge cooling, the thermal input could be extended past the tape edges by the amount Delta a. This method should help achieve uniform weld strength and crystallinity across the width of the tape.

Costen, Robert C.↗

Characterization of edge damage induced on REBCO superconducting tape by mechanical slitting

Abstract Rare-earth barium-copper-oxide (REBCO) superconductors are high-field superconductors fabricated in a tape geometry that can be utilized in magnet applications well in excess of 20 T. Due to the multilayer architecture of the tape, delamination is one cause of mechanical failure in REBCO tapes. During a mechanical slitting step in the manufacturing process, edge cracks can be introduced into the tape. These cracks are thought to be potential initiation sites for crack propagation in the tapes when subjected to stresses in the fabrication and operation of magnet systems. We sought to understand which layers were the mechanically weakest by locating the crack initiation layer and identifying the geometrical conditions of the slitter that promoted or suppressed crack formation. The described cracking was investigated by selectively etching and characterizing each layer with scanning electron microscopy, laser confocal microscopy, and digital image analysis. Our analysis showed that the average crack lengths in the REBCO, LaMnO 3 (LMO) and Al 2 O 3 layers were 34 μ m, 28 μ m, and 15 μ m, respectively. The total number of cracks measured in 30 mm of wire length was between 3000 and 5700 depending on the layer and their crack densities were 102 cracks mm −1 for REBCO, 108 cracks mm −1 for LMO, and 183 cracks mm −1 for Al 2 O 3 . These results indicated that there are separate crack initiation mechanisms for the REBCO and the LMO layers, as detailed in the paper. With a better understanding of the crack growth behavior exhibited by REBCO tapes, the fabrication process can be improved to provide a more mechanically stable and cost-effective superconductor.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development and performance of high-temperature superconducting CORC ® cables with CFD REBCO tapes

Abstract Increasing the normal zone propagation velocity (NZPV) in superconducting cables based on rare earth barium copper oxide (REBCO) tapes is expected to cause a paradigm shift by enabling the development of faster and more reliable quench detection systems to mitigate the development of destructive hot spots. Furthermore, a higher NZPV is beneficial in terms of fault current limitation capabilities by accelerating the homogenization of the quench in superconducting power devices. One way envisioned to increase the NZPV of cables based on REBCO tapes is the current flow diverter (CFD) concept. A Conductor on Round Core (CORC ® ) cable made with CFD REBCO tapes, called CFD CORC ® cable, and a CORC ® cable made with regular REBCO tapes, were fabricated and tested. The critical current of the CFD and regular CORC ® cables were obtained at temperatures ranging from 67 to 77 K in self-field. Measurements showed that the NZPV was increased by a factor of 4–4.5 in the case of the CFD CORC ® cable. Furthermore, the results suggest that the NZPV depends only on the applied current, similar to what has been observed previously on single REBCO tapes. These results demonstrate the successful integration of CFD REBCO tapes in CORC ® cables, without compromising their superconducting properties or their enhanced NZPV. The possibility of enhancing the NZPV of REBCO-based cables could facilitate quench detection, which remains an important issue in HTS magnet applications. This advancement also holds promise for the fault current limitation functionality of CORC ® cables.

Ben Saâd, Haïfa (ORCID:0000000216205364)↗

Tape Casting of Thin Electrolyte and Thick Cathode for Halide-Based All-Solid-State Batteries

Most previous studies about halide solid-state electrolytes have used pellets prepared by uniaxial pressing, which is a good approach for materials development but is not suitable for commercialization. Thinner electrolyte layers that can be scaled up to large cell areas are required, and tape casting is a promising approach. It is challenging, however, as halide materials are reactive with most of the conventional solvents used in the process. In this study, solvents with low polarity, such as toluene, are found to be compatible with the Li 3 YBr 6 halide material. A wide variety of candidate binders that are soluble in toluene are studied. MSB1–13 binder is preferred, based on the ionic conductivity and mechanical properties of the tape. Electrolyte tapes (<70 μ m) are successfully cast on Al substrates, using 2 wt% binder. The resulting room temperature ionic conductivity is 2 × 10 −4 S cm −1 . Two composite cathodes including active material (LiFePO 4 or LiNi 0.82 Mn 0.07 Co 0.11 O 2 ) and 1 to 1.5 wt% MSB1–13 are tape cast as proof-of-concept for a scalable cell fabrication approach. A LiFePO 4 cell shows good retention at 25 °C. The performance of NMC cells with tape electrolyte or pellet electrolyte is similar. This study demonstrates the feasibility of tape casting halide-based electrolytes and cathodes.

25 ENERGY STORAGE↗

Calibration tests on magnetic tape lightning current detectors

The low cost, passive, peak lightning current detector (LCD) invented at the NASA/Kennedy Space Center, uses magnetic audio recording tape to sense the magnitude of the peak magnetic field around a conductor carrying lightning currents. Test results show that the length of audio tape erased was linearly related to the peak simulated lightning currents in a round conductor. Accuracies of + or - 10% were shown for measurements made using a stopwatch readout technique to determine the amount of tape erased by the lightning current. The stopwatch technique is a simple, low cost means of obtaining LCD readouts and can be used in the field to obtain immediate results. Where more accurate data are desired, the tape is played and the output recorded on a strip chart, oscilloscope, or some other means so that measurements can be made on that recording. Conductor dimensions, tape holder dimensions, and tape formulation must also be considered to obtain a more accurate result. If the shape of the conductor is other than circular (i.e., angle, channel, H-beam), an analysis of the magnetic field is required to use an LCD, especially at low current levels.

Crouch, K. E.↗

Magnetic tape lightning current detectors

Development and application tests of a low cost, passive, peak lightning current detector (LCD) found it to provide measurements with accuracies of + or - 5 percent to + or - 10 percent depending on the readout method employed. The LCD uses magnetic audio recording tape to sense the magnitude of the peak magnetic field around a conductor carrying lightning currents. The test results showed that the length of audio tape erased was linearly related to the peak simulated lightning currents in a round conductor. Accuracies of + or - 10 percent were shown for measurements made using a stopwatch readout technique to determine the amount of tape erased by the lightning current. Where more accurate data are desired, the tape is played and the output recorded on a strip chart, oscilloscope, or some other means so that measurements can be made on that recording. Conductor dimensions, tape holder dimensions, and tape formulation must also be considered to obtain a more accurate result.

Crouch, K. E.↗

LGSOWG CCT format CCB document: The standard CCT family of tape formats

The tape format standardization approach recommended by the committee on CCT standardization is described and defined. All rules and conventions required to employ the superstructure approach to the CCT family of tape formats are presented for users of remote sensing data and producer of user tapes and the superstructure records are specified. The standard for future tape format design is presented as a guide to designing data records of a particular tape format. An example is provided showing how to incorporate the superstructure into an already established tape format.

Source record↗

Water-vapor effects on friction of magnetic tape in contact with nickel-zinc ferrite

The effects of humidity of moist nitrogen on the friction and deformation behavior of magnetic tape in contact with a nickel-zinc ferrite spherical pin were studied. The results indicate that the coefficient of friction is markedly dependent on the ambient relative humidity. Although the coefficient of friction remains low below 40-percent relative humidity, it increases rapidly with increasing relative humidity above 40 percent. The general ambient environment of the tape does not have any effect on the friction behavior if the area where the tape is in sliding contact with the ferrite pin is flooded with controlled nitrogen. The response time for the friction of the tape to humidity changes is about 10 sec. The effect of friction as a function of relative humidity on dehumidifying is very similar to that on humidifying. A surface softening of the tape due to water vapor increases the friction of the tape.

Miyoshi, K.↗