At least 73 records · Page 4

The ISEE-3 ULEWAT: Flux tape description and heavy ion fluxes 1978-1984

The ISEE ULEWAT FLUX tapes contain ULEWAT and ISEE pool tape data summarized over relatively long time intervals (1hr) in order to compact the data set into an easily usable size. (Roughly 3 years of data fit onto one 1600 BPI 9-track magnetic tape). In making the tapes, corrections were made to the ULEWAT basic data tapes in order to, remove rate spikes and account for changes in instrument response so that to a large extent instrument fluxes can be calculated easily from the FLUX tapes without further consideration of instrument performance.

Mason, G. M.↗

Integration of altitude and airspeed information into a primary flight display via moving-tape formats: Evaluation during random tracking task

A ground-based aircraft simulation study was conducted to determine the effects on pilot preference and performance of integrating airspeed and altitude information into an advanced electronic primary flight display via moving-tape (linear moving scale) formats. Several key issues relating to the implementation of moving-tape formats were examined in this study: tape centering, tape orientation, and trend information. The factor of centering refers to whether the tape was centered about the actual airspeed or altitude or about some other defined reference value. Tape orientation refers to whether the represented values are arranged in descending or ascending order. Two pilots participated in this study, with each performing 32 runs along seemingly random, previously unknown flight profiles. The data taken, analyzed, and presented consisted of path performance parameters, pilot-control inputs, and electrical brain response measurements.

Abbott, Terence S.↗

Magnetic-Tape Utilities Computer Program

Fast Magnetic Tape Utility package (MTUTILS/TUTIL) is collection of subroutines for DEC VAX/VMS computers designed to simplify access to magnetic-tape drives. Routines use standard FORTRAN argument binding and simpler than corresponding system service calls. Two sets of routines: one enables basic tape operation; other certain operations performed on sequence of tape drives. Enables manipulation of sets of data too large to be held on single magnetic tape. Program user-friendly, menu-driven employing MTUTILS package to process tapes interactively.

Olson, N. E.↗

Mass optical storage-tape (MOST)

In today's large mainframe and supercomputer environment there exists a continuous demand for increased performance in digital storage systems. The user need for near-line storage capacity is currently doubling every four years. In addition to higher capacity, a desire exists for higher data transfer rates, and longer term database archivability, at lower, and lower cost. Each component of this quartet of demands appears to be insatiable. Magnetic tape technology presently dominates the digital mass storage markets, but the continuous growth of requirements is drawing attention to the limitations of the technology as an archival mass storage medium. The lowest cost option currently available for long term data storage is to use magnetic tape, although it is not well suited to meeting the need for many tens of years of reliable storage. Today, the majority of magnetic tape mass storage systems are based on the IBM 3480/3490 (or compatible) tape drives. These drives offer only moderate transfer rates and relatively small increments of storage, both of which create a logistics problem due to the large numbers of cartridges necessary in a typical system and the time taken to transfer data. Both higher cartridge capacity and data transfer rates are available in some helical scan magnetic tape systems; however, these command a substantially higher price, exacerbating the cost problem, and are not compatible with most installed systems or tape databases.

Oakley, William S.↗

Recording and wear characteristics of 4 and 8 mm helical scan tapes

Performance data of media on helical scan tape systems (4 and 8 mm) is presented and various types of media are compared. All measurements were performed on a standard MediaLogic model ML4500 Tape Evaluator System with a Flash Converter option for time based measurements. The 8 mm tapes are tested on an Exabyte 8200 drive and 4 mm tapes on an Archive Python drive; in both cases, the head transformer is directly connected to a Media Logic Read/Write circuit and test electronics. The drive functions only as a tape transport and its data recover circuits are not used. Signal to Noise, PW 50, Peak Shift and Wear Test data is used to compare the performance of MP (metal particle), BaFe, and metal evaporate (ME). ME tape is the clear winner in magnetic performance but its susceptibility to wear and corrosion, make it less than ideal for data storage.

Peter, Klaus J.↗

Damage tolerance of pressurized graphite/epoxy tape cylinders under uniaxial and biaxial loading

The damage tolerance behavior of internally pressurized, axially slit, graphite/epoxy tape cylinders was investigated. Specifically, the effects of axial stress, structural anisotropy, and subcritical damage were considered. In addition, the limitations of a methodology which uses coupon fracture data to predict cylinder failure were explored. This predictive methodology was previously shown to be valid for quasi-isotropic fabric and tape cylinders but invalid for structurally anisotropic (+/-45/90)(sub s) and (+/-45/0)(sub s) cylinders. The effects of axial stress and structural anisotropy were assessed by testing tape cylinders with (90/0/+/-45)(sub s), (+/-45/90)(sub s), and (+/-45/0)(sub s) layups in a uniaxial test apparatus, specially designed and built for this work, and comparing the results to previous tests conducted in biaxial loading. Structural anisotropy effects were also investigated by testing cylinders with the quasi-isotropic (0/+/-45/90)(sub s) layup which is a stacking sequence variation of the previously tested (90/0/+/-45)(sub s) layup with higher D(sub 16) and D(sub 26) terms but comparable D(sub 16) and D(sub 26) to D(sub 11) ratios. All cylinders tested and used for comparison are made from AS4/3501-6 graphite/epoxy tape and have a diameter of 305 mm. Cylinder slit lengths range from 12.7 to 50.8 mm. Failure pressures are lower for the uniaxially loaded cylinders in all cases. The smallest percent failure pressure decreases are observed for the (+/-45/90)(sub s) cylinders, while the greatest such decreases are observed for the (+/-45/0)(sub s) cylinders. The relative effects of the axial stress on the cylinder failure pressures do not correlate with the degree of structural coupling. The predictive methodology is not applicable for uniaxially loaded (+/-45/90)(sub s) and (+/-45/0)(sub s) cylinders, may be applicable for uniaxially loaded (90/0/+/-45)(sub s) cylinders, and is applicable for the biaxially loaded (90/0/+/-45)(sub s) and (0/+/-45/90)(sub s) cylinders. This indicates that the ratios of D(sub 16) and D(sub 26) to D(sub 11), as opposed to the absolute magnitudes of D(sub 16) and D(sub 26), may be important in the failure of these cylinders and in the applicability of the methodology. Discontinuities observed in the slit tip hoop strains for all the cylinders tested indicate that subcritical damage can play an important role in the failure of tape cylinders. This role varies with layup and loading condition and is likely coupled to the effects of structural anisotropy. Biaxial failure pressures may exceed the uniaxial values because the axial stress contributes to the formation of 0 deg ply splitting (accompanied by delamination) or similar stress-mitigating subcritical damage. The failure behavior of similar cylinders can also vary as a result of differences in the role of subcritical damage as observed for the case of a biaxially loaded (90/0/+/-45)(sub s) cylinder with a 12.7 mm slit. For this case, the methodology is valid when the initial coupon and cylinder fracture modes agree. However, the methodology underpredicts the failure pressure of the cylinder when a circumferential fracture path, suggestive of a 0 deg ply split, occurs at one slit tip. Thus, the failure behavior of some tape cylinders may be highly sensitive to the initial subcritical damage mechanism. Finite element analyses are recommended to determine how structural anisotropy and axial stress modify the slit tip stress states in cylinders from those found in flat plates since similarity of these stress states is a fundamental assumption of the current predictive methodology.

Priest, Stacy Marie↗

Certification of ICI 1012 optical data storage tape

ICI has developed a unique and novel method of certifying a Terabyte optical tape. The tape quality is guaranteed as a statistical upper limit on the probability of uncorrectable errors. This is called the Corrected Byte Error Rate or CBER. We developed this probabilistic method because of two reasons why error rate cannot be measured directly. Firstly, written data is indelible, so one cannot employ write/read tests such as used for magnetic tape. Secondly, the anticipated error rates need impractically large samples to measure accurately. For example, a rate of 1E-12 implies only one byte in error per tape. The archivability of ICI 1012 Data Storage Tape in general is well characterized and understood. Nevertheless, customers expect performance guarantees to be supported by test results on individual tapes. In particular, they need assurance that data is retrievable after decades in archive. This paper describes the mathematical basis, measurement apparatus and applicability of the certification method.

Howell, J. M.↗

One-step Tape Casting of Composites via Slurry on Fiber

A process by which metal matrix composites can be made was presented. The process involves putting a powder slurry on fibers to make a precursor green tape. These green tapes are cut, stacked and hot pressed to form the fully dense composite. A computer program was presented which enables complete quantification and control of the process. Once some easily obtained properties of the slurry and its behavior are determined (such as the shrinkage from the wet to green state, and the density of the green tape) modification of the fiber spacing and blade height give the maker precise control of fiber volume fraction, and fiber architecture in the composite. The process was shown to be accurate and flexible through the production of a wide variety of volume fraction fiber composites made from a wide variety of fibers and powders. The most time consuming step of the tape casting process (other than hot pressing) was winding the fiber on the drum. The tape casting techniques developed resulted in high quality metal matrix composites, with ultimate tensile strength in the range of 215 ksi (1477 MPa), a strain at failure of 1.15 percent, and in fatigue at room temperature 0 to 120 ksi, n = 0.3 Hz, a 4-ply Ti-24Al-11Nb/SCS-6, 32 vol% fiber tape cast composite lasted 202,205 cycles with a maximum strain on the 100th cycle of 0.43 percent.

deGroh, Henry C., III↗

Dry Process for Making Polyimide/ Carbon-and-Boron-Fiber Tape

A dry process has been invented as an improved means of manufacturing composite prepreg tapes that consist of high-temperature thermoplastic polyimide resin matrices reinforced with carbon and boron fibers. Such tapes are used (especially in the aircraft industry) to fabricate strong, lightweight composite-material structural components. The inclusion of boron fibers results in compression strengths greater than can be achieved by use of carbon fibers alone. The present dry process is intended to enable the manufacture of prepreg tapes (1) that contain little or no solvent; (2) that have the desired dimensions, fiber areal weight, and resin content; and (3) in which all of the fibers are adequately wetted by resin and the boron fibers are fully encapsulated and evenly dispersed. Prepreg tapes must have these properties to be useable in the manufacture of high-quality composites by automated tape placement. The elimination of solvent and the use of automated tape placement would reduce the overall costs of manufacturing.

Belvin, Harry L.↗

Feasibility model of a high reliability five-year tape transport, Volume 1

The development, performance, and test results for the spaceborne magnetic tape transport are discussed. An analytical model of the tape transport was used to optimize its conceptual design. Each of the subsystems was subjected to reliability analyses which included structural integrity, maintenance of system performance within acceptable bounds, and avoidance of fatigue failure. These subsystems were also compared with each other in order to evaluate reliability characteristics. The transport uses no mechanical couplings. Four drive motors, one for each reel and one for each of two capstans, are used in a differential mode. There are two hybrid, spherical, cone tapered-crown rollers for tape guidance. Storage of the magnetic tape is provided by a reel assembly which includes the reel, a reel support structure and bearings, dust seals, and a dc drive motor. A summary of transport test results on tape guidance, flutter, and skew is provided.

Eshleman, R. L.↗

FGGE/ERBZ tape specification and shipping letter description

The FGGE/ERBZ tape contains 5 parameters which are extracted and reformatted from the Nimbus-7 ERB Zonal Means Tape. There are three types of files on a FGGE/ERBZ tape: a tape header file, and data files. Physical characteristics, gross format, and file specifications are given. A sample tape check/document printout (shipping letter) is included.

Han, D.↗

Effect of crystallographical and geometrical changes of a ferrite head on magnetic signals during the sliding process with magnetic tape

This paper reviews changes in the crystalline structure and geometry of lapped Mn-Zn ferrite heads in sliding contact with magnetic tape and the effects of these changes on magnetic signals. A highly textured, polycrystalline structure was produced on the surface of a single-crystal Mn-Zn ferrite head when it was finished with an aluminum oxide lapping tape. Sliding this lapped surface against a magnetic tape produced a nearly amorphous structure. The sliding process led to a degradation in readback signal of 1 to 2 dB (short-wavelength recording). Furthermore, wear of the magnetic head caused geometrical changes in the head surface. The signal read back with the worn magnetic head was sensitive to operating parameters such as head displacement and tape tension. A change in operating parameters created head-to-tape spacings and, consequently, excessive gains or losses in the readback signal.

Miyoshi, K.↗

Portable digital pressure indicator for calibrating magnetic tape recorders

The design of a portable Digital Pressure Indicator (DPI) to be used for calibrating the pressure systems on Langley's magnetic tape recorders is described. High-speed magnetic tape recorders require pressure (0 to 20 psig) for providing an air cushion across the tape guides and a slight vacuum (30 inch H2O) for maintaining the proper number of tape loops in the advance and feed chamber. The DPI is a hand-held device that can be quickly coupled to a magnetic tape recorder and includes a two-position switch for selecting either measured pressure or vacuum, to be displayed digitally in engineering units (psig or inches H2O). The DPI is currently in use in Langley's Analysis and Computation Division.

Mccormick, Royce F.↗

Digital Linear Tape (DLT) technology and product family overview

The demand that began a couple of years ago for increased data storage capacity continues. Peripheral Strategies (a Santa Barbara, California, Storage Market Research Firm) projects the amount of data stored on the average enterprise network will grow by 50 percent to 100 percent per year. Furthermore, Peripheral Strategies says that a typical mid-range workstation system containing 30GB to 50GB of storage today will grow at the rate of 50 percent per year. Dan Friedlander, a Boulder, Colorado-based consultant specializing in PC-LAN backup, says, 'The average NetWare LAN is about 8GB, but there are many that have 30GB to 300GB.....' The substantial growth of storage requirements has created various tape technologies that seek to satisfy the needs of today's and, especially, the next generations's systems and applications. There are five leading tape technologies in the market today: QIC (Quarter Inch Cartridge), IBM 3480/90, 8mm, DAT (Digital Audio Tape) and DLT (Digital Linear Tape). Product performance specifications and user needs have combined to classify these technologies into low-end, mid-range, and high-end systems applications. Although the manufacturers may try to position their products differently, product specifications and market requirements have determined that QIC and DAT are primarily low-end systems products while 8mm and DLT are competing for mid-range systems applications and the high-end systems space, where IBM compatibility is not required. The 3480/90 products seem to be used primarily in the IBM market, for interchangeability purposes. There are advantages and disadvantages for each of the tape technologies in the market today. We believe that DLT technology offers a significant number of very important features and specifications that make it extremely attractive for most current as well as emerging new applications, such as Hierarchical Storage Management (HSM). This paper will demonstrate why we think that the DLT technology and family of DLT products will become the technology of choice for most new applications in the mid-range and high-end (non-IBM) markets.

Lignos, Demetrios↗

Tape recorder failure investigation

Two end-item tape recorders lost 4:1 mode data recording mode capability at less than half of their 1 6,000-cycle, 4-year operating life. Subsequent life tests on two spare recorders also experienced 4:1 mode data loss at 8,000 and 11,700 cycles. Tear down inspection after completion of the life tests showed that the tape had worn through the alfesil record and reproduce heads. An investigation was initiated to understand the cause of excessive tape head wear and the reasons why the 4:1 mode data rate, low-speed mode is more damaging than the 1:1 mode data rate, high-speed recording mode. The objective was to establish how operating conditions (tape speed, humidity, temperature, stop/start cycles) affects head life with the goal of extending head life on the remaining in-service tape recorders. Another interest was to explain why an earlier vendor life test showed capability beyond 16,000 cycles.

Higgins, M. D.↗

The Galileo Tape Recorder Rewind Operation Anomaly

On October 11, 1995, the Galileo spacecraft executed a sequence to record three approach images of Jupiter on the spacecraft's tape recorder, rewind the tape, and play back the images at the appropriate data rate consistent with the downlink performance. The recording of the images was performed and the spacecraft computer commanded the tape recorder to rewind the tape to the beginning of the first image. The rewind command was started at the proper time but the tape never got to the beginning of the image data. The analyses and tests that followed allowed a conclusive determination of the failure mechanism and indicated a strategy that could be used to prevent the untimely demise of the mission.

Johnson, Michael R.↗

An Atmospheric Tape Recorder: The Imprint of Tropical Tropopause Temperatures on Stratospheric Water Vapor

We describe observations of tropical stratospheric water vapor q that show clear evidence of large-scale upward advection of the signal from annual fluctuations in the effective 'entry mixing ratio' q(sub E) of air entering the tropical stratosphere. In other words, air is 'marked,' on emergence above the highest cloud tops, like a signal recorded on an upward moving magnetic tape. We define q(sub E) as the mean water vapor mixing ratio, at the tropical tropopause, of air that will subsequently rise and enter the stratospheric 'overworld' at about 400 K. The observations show a systematic phase lag, increasing with altitude, between the annual cycle in q(sub E) and the annual cycle in q at higher altitudes. The observed phase lag agrees with the phase lag calculated assuming advection by the transformed Eulerian-mean vertical velocity of a q(sub E) crudely estimated from 100-hPa temperatures, which we use as a convenient proxy for tropopause temperatures. The phase agreement confirms the overall robustness of the calculation and strongly supports the tape recorder hypothesis. Establishing a quantitative link between q(sub E) and observed tropopause temperatures, however, proves difficult because the process of marking the tape depends subtly on both small- and large-scale processes. The tape speed, or large-scale upward advection speed, has a substantial annual variation and a smaller variation due to the quasi-biennial oscillation, which delays or accelerates the arrival of the signal by a month or two in the middle stratosphere. As the tape moves upward, the signal is attenuated with an e-folding time of about 7 to 9 months between 100 and 50 hPa and about 15 to 18 months between 50 and 20 hPa, constraining possible orders of magnitude both of vertical diffusion K(sub z) and of rates of mixing in from the extratropics. For instance, if there were no mixing in, then K(sub z) would be in the range 0.03-0.09 m(exp 2)/s; this is an upper bound on K(sub z).

Mote, Philip W.↗

Induction Bonding of Prepreg Tape and Titanium Foil

Hybrid structural laminates made of titanium foil and carbon fiber reinforced polymer composite offer a potential for improved performance in aircraft structural applications. To obtain information needed for the automated fabrication of hybrid laminates, a series of bench scale tests were conducted of the magnetic induction bonding of titanium foil and thermoplastic prepreg tape. Foil and prepreg specimens were placed in the gap of a toroid magnet mounted in a bench press. Several magnet power supplies were used to study power at levels from 0.5 to 1.75 kW and frequencies from 50 to 120 kHz. Sol-gel surface-treated titanium foil, 0.0125 cm thick, and PIXA/IM7 prepreg tape were used in several lay-up configurations. Data were obtained on wedge peel bond strength, heating rate, and temperature ramp over a range of magnet power levels and frequencies at different "power-on" times for several magnet gap dimensions. These data will be utilized in assessing the potential for automated processing. Peel strengths of foil-tape bonds depended on the maximum temperature reached during heating and on the applied pressure. Maximum peel strengths were achieved at 1.25kW and 8OkHz. Induction heating of the foil appears to be capable of good bonding up to 10 plies of tape. Heat transfer calculations indicate that a 20-40 C temperature difference exists across the tape thickness during heat-up.

Messier, Bernadette C.↗