Search NASA⌕ Search

SEARCH · Search NASA

Results for “Technical Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Quality Assurance Program Plan for SFR Metallic Fuel Data Qualification

This document contains an evaluation of the applicability of the current Quality Assurance Standards from the American Society of Mechanical Engineers Standard NQA-1 (NQA-1) criteria and identifies and describes the quality assurance process(es) by which attributes of historical, analytical, and other data associated with sodium-cooled fast reactor [SFR] metallic fuel will be evaluated. This process is being instituted to facilitate validation of data to the extent that such data may be used to support future licensing efforts associated with advanced reactor designs. The initial data to be evaluated under this program were generated during the US Integral Fast Reactor program between 1984-1994, where the data includes, but is not limited to, research and development data and associated documents, test plans and associated protocols, operations and test data, technical reports, and information associated with past United States Nuclear Regulatory Commission reviews of SFR designs. It is recognized that managing the data generated by large research and development projects presents a significant challenge for retaining data integrity and availability. American Society of Mechanical Engineers Standard NQA-1 (NQA-1) 2008/2009a provides appropriate requirements for this plan.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quality Assurance Program Plan for SFR Metallic Fuel Data Qualification

This document contains an evaluation of the applicability of the current Quality Assurance Standards from the American Society of Mechanical Engineers Standard NQA-1 (NQA-1) criteria and identifies and describes the quality assurance process(es) by which attributes of historical, analytical, and other data associated with sodium-cooled fast reactor [SFR] metallic fuel will be evaluated. This process is being instituted to facilitate validation of data to the extent that such data may be used to support future licensing efforts associated with advanced reactor designs. The initial data to be evaluated under this program were generated during the US Integral Fast Reactor program between 1984-1994, where the data include, but are not limited to, research and development data and associated documents, test plans and associated protocols, operations and test data, technical reports, and information associated with past United States Nuclear Regulatory Commission reviews of SFR designs. It is recognized that managing the data generated by large research and development projects presents a significant challenge for retaining data integrity and availability. American Society of Mechanical Engineers Standard NQA-1 (NQA-1) 2008/2009a provides appropriate requirements for this plan.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quality Assurance Program Plan for SFR Metallic Fuel Data Qualification

This document contains an evaluation of the applicability of the current Quality Assurance Standards from the American Society of Mechanical Engineers Standard NQA-1 (NQA-1) criteria and identifies and describes the quality assurance process(es) by which attributes of historical, analytical, and other data associated with sodium-cooled fast reactor [SFR] metallic fuel will be evaluated. This process is being instituted to facilitate validation of data to the extent that such data may be used to support future licensing efforts associated with advanced reactor designs. The initial data to be evaluated under this program were generated during the US Integral Fast Reactor program between 1984-1994, where the data include, but are not limited to, research and development data and associated documents, test plans and associated protocols, operations and test data, technical reports, and information associated with past United States Nuclear Regulatory Commission reviews of SFR designs. It is recognized that managing the data generated by large research and development projects presents a significant challenge for retaining data integrity and availability. American Society of Mechanical Engineers Standard NQA-1 (NQA-1) 2008/2009a provides appropriate requirements for this plan.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

HyRAM (Hydrogen Risk Assessment Models) v. 1.0

HyRAM is a software toolkit for conducting quantitative risk assessment (QRA) and consequence modeling for hydrogen infrastructure and transportation systems. HyRAM contains validated, simplified hydrogen behavior models, a standardized QRA approach, and engineering models and generic data relevant to hydrogen installations. HyRAM 1.0 was developed by Sandia National Laboratories for the U. S. Department of Energy to increase access to technical data about hydrogen and to enable the use of that data to support development and revision of national and international codes and standards with risk assessment and consequence modeling. The HyRAM toolkit integrates analytical and probabilistic models for quantifying accident scenarios, predicting physical effects, and characterizing the impact of hydrogen hazards (including thermal effects from jet fires and overpressure effects from deflagrations in confined areas) on people and structures. HyRAM incorporates generic probabilities for equipment failures for nine types of components, and probabilistic models for the impact of heat flux on humans and structures, with computationally and experimentally validated analytical first order models of hydrogen release and flame physics. Version 1 can be used to quantify the risk and consequences associated with gaseous hydrogen releases from user-defined hydrogen installations.

Groth, Katrina M.↗

MO-FG-207-00: Technological Advances in PET/MR Imaging

The use of integrated PET/MRI systems in clinical applications can best benefit from understanding their technological advances and limitations. The currently available clinical PET/MRI systems have their own characteristics. Thorough analyses of existing technical data and evaluation of necessary performance metrics for quality assurances could be conducted to optimize application-specific PET/MRI protocols. This Symposium will focus on technical advances and limitations of clinical PET/MRI systems, and how this exciting imaging modality can be utilized in applications that can benefit from both PET and MRI. Learning Objectives: To understand the technological advances of clinical PET/MRI systems To correctly identify clinical applications that can benefit from PET/MRI To understand ongoing work to further improve the current PET/MRI technology Floris Jansen is a GE Healthcare employee.

60 APPLIED LIFE SCIENCES↗

MO-FG-207-01: Technological Advances and Challenges: Experience with the First Integrated Whole-Body PET/MRI

The use of integrated PET/MRI systems in clinical applications can best benefit from understanding their technological advances and limitations. The currently available clinical PET/MRI systems have their own characteristics. Thorough analyses of existing technical data and evaluation of necessary performance metrics for quality assurances could be conducted to optimize application-specific PET/MRI protocols. This Symposium will focus on technical advances and limitations of clinical PET/MRI systems, and how this exciting imaging modality can be utilized in applications that can benefit from both PET and MRI. Learning Objectives: To understand the technological advances of clinical PET/MRI systems To correctly identify clinical applications that can benefit from PET/MRI To understand ongoing work to further improve the current PET/MRI technology Floris Jansen is a GE Healthcare employee.

60 APPLIED LIFE SCIENCES↗

MO-FG-207-02: Technological Advances and Challenges: Experience with Time-Of-Flight PET Combined with 3-Tesla MRI

The use of integrated PET/MRI systems in clinical applications can best benefit from understanding their technological advances and limitations. The currently available clinical PET/MRI systems have their own characteristics. Thorough analyses of existing technical data and evaluation of necessary performance metrics for quality assurances could be conducted to optimize application-specific PET/MRI protocols. This Symposium will focus on technical advances and limitations of clinical PET/MRI systems, and how this exciting imaging modality can be utilized in applications that can benefit from both PET and MRI. Learning Objectives: To understand the technological advances of clinical PET/MRI systems To correctly identify clinical applications that can benefit from PET/MRI To understand ongoing work to further improve the current PET/MRI technology Floris Jansen is a GE Healthcare employee.

60 APPLIED LIFE SCIENCES↗

MO-FG-207-03: Maximizing the Utility of Integrated PET/MRI in Clinical Applications

The use of integrated PET/MRI systems in clinical applications can best benefit from understanding their technological advances and limitations. The currently available clinical PET/MRI systems have their own characteristics. Thorough analyses of existing technical data and evaluation of necessary performance metrics for quality assurances could be conducted to optimize application-specific PET/MRI protocols. This Symposium will focus on technical advances and limitations of clinical PET/MRI systems, and how this exciting imaging modality can be utilized in applications that can benefit from both PET and MRI. Learning Objectives: To understand the technological advances of clinical PET/MRI systems To correctly identify clinical applications that can benefit from PET/MRI To understand ongoing work to further improve the current PET/MRI technology Floris Jansen is a GE Healthcare employee.

60 APPLIED LIFE SCIENCES↗

Data Availability in Appliance Standards and Labeling Program Development and Evaluation

In this report, we describe the necessary data inputs for both standards development and program evaluation and perform an initial assessment of the availability and uncertainty of those data inputs in China. For standards development, we find that China and its standards and labeling program administrators currently has access to the basic market and technical data needed for conducting market and technology assessment and technological and economic analyses. Some data, such as shipments data, is readily available from the China Energy Label product registration database while the availability of other data, including average unit energy consumption, prices and design options, needs improvement. Unlike some other countries such as the United States, most of the necessary data for conducting standards development analyses are not publicly available or compiled in a consolidated data source. In addition, improved data on design and efficiency options as well as cost data (e.g., manufacturing costs, mark-ups, production and product use-phase costs) – key inputs to several technoeconomic analyses – are particularly in need given China’s unconsolidated manufacturing industry. For program evaluation, we find that while China can conduct simple savings evaluations on its incentive programs with the data it currently has available from the Ministry of Finance – the program administrator, the savings estimates produced by such an evaluation will carry high uncertainty. As such, China could benefit from an increase in surveying and metering in the next one to three years to decrease the uncertainty surrounding key data points such as unit energy savings and free ridership.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

National Geothermal Data System: Transforming the Discovery, Access, and Analytics of Data for Geothermal Exploration

Compendium of Papers from the 38th Workshop on Geothermal Reservoir Engineering Stanford University, Stanford, California February 11-13, 2013 The National Geothermal Data System (NGDS) is a distributed, interoperable network of data collected from state geological surveys across all fifty states and the nation’s leading academic geothermal centers. The system serves as a platform for sharing consistent, reliable, geothermal-relevant technical data with users of all types, while supplying tools relevant for their work. As aggregated data supports new scientific findings, this content-rich linked data ultimately broadens the pool of knowledge available to promote discovery and development of commercial-scale geothermal energy production. Most of the up-front risks associated with geothermal development stem from exploration and characterization of subsurface resources. Wider access to distributed data will, therefore, result in lower costs for geothermal development. NGDS is on track to become fully operational by 2014 and will provide a platform for custom applications for accessing geothermal relevant data in the U.S. and abroad. It is being built on the U.S. Geoscience Information Network (USGIN) data integration framework to promote interoperability across the Earth sciences community. The basic structure of the NGDS employs state-of-the art informatics to advance geothermal knowledge. The following four papers comprising this Open-File Report are a compendium of presentations, from the 38th Annual Workshop on Geothermal Reservoir Engineering, taking place February 11-13, 2013 at Stanford University, Stanford, California. “NGDS Geothermal Data Domain: Assessment of Geothermal Community Data Needs,” outlines the efforts of a set of nationwide data providers to supply data for the NGDS. In particular, data acquisition, delivery, and methodology are discussed. The paper addresses the various types of data and metadata required and why simple links to existing data are insufficient for promoting geothermal exploration. Authors of this paper are Arlene Anderson, US DOE Geothermal Technologies Office, David Blackwell, Southern Methodist University (SMU), Cathy Chickering (SMU), Toni Boyd, Oregon Institute of Technology’s GeoHeat Center, Roland Horne, Stanford University, Matthew MacKenzie, Uberity, Joe Moore, University of Utah, Duane Nickull, Uberity, Stephen Richard, Arizona Geological Survey, and Lisa Shevenell, University of Nevada, Reno. “NGDS User Centered Design: Meeting the Needs of the Geothermal Community,” discusses the user- centered design approach taken in the development of a user interface solution for the NGDS. The development process is research based, highly collaborative, and incorporates state-of-the-art practices to ensure a quality user interface for the widest and greatest utility. Authors of this paper are Harold Blackman, Boise State University, Suzanne Boyd, Anthro-Tech, Kim Patten, Arizona Geological Survey, and Sam Zheng, Siemens Corporate Research. “Fueling Innovation and Adoption by Sharing Data on the DOE Geothermal Data Repository Node on the National Geothermal Data System,” describes the motivation behind the development of the Geothermal Data Repository (GDR) and its role in the NGDS. This includes the benefits of using the GDR to share geothermal data of all types and DOE’s data submission process. Authors of this paper are Jon Weers, National Renewable Energy Laboratory and Arlene Anderson, US DOE Geothermal Technologies Office. Finally, “Developing the NGDS Adoption of CKAN for Domestic & International Data Deployment,” provides an overview of the “Node-In-A-Box” software package designed to provide data consumers with a highly functional interface to access the system, and to ease the burden on data providers who wish to publish data in the system. It is important to note that this software package constitutes a reference implementation and that the NGDS architecture is based on open standards, which means other server software can make resources available, and other client applications can utilize NGDS data. Authors of this paper are Ryan Clark, Arizona Geological Survey (AZGS), Christoph Kuhmuench, Siemens Corporate Research, and Stephen Richard, AZGS.

15 GEOTHERMAL ENERGY↗

Technical and Imaging Outcomes from the UK Registry of Prostate Artery Embolization (UK-ROPE) Study: Focusing on Predictors of Clinical Success

Introduction: The UK Registry of Prostate Artery Embolization (UK-ROPE) was a prospective, multicentre study comparing PAE against surgical therapies for symptomatic benign prostatic hyperplasia (BPH). A wealth of data was collected supplementary to the main study outcomes which provide a snapshot of UK PAE practice. We aimed to interpret these data in the hope of providing insight into factors which affect clinical outcome and radiation dose. Methods: 216 patients (mean age 66, mean IPSS 21.3) undergoing PAE at 20 British centres from July 2014 to January 2016 were prospectively followed up to 12 months with retrospective analysis of the data. Technical outcome was evaluated based on procedural and fluoroscopy times, skin dose and dose area product (DAP). Clinical outcome was evaluated through collection of Qmax, IPSS reduction and prostate volume reduction. Multiple analysis of variance (MANOVA) was used to assess the significance of various patients and procedural factors on clinical outcome and patient dose. Results: Significant predictors of technical outcome which affected patient skin dose included severity of CTA-detected atheroma (p < 0.001), the practitioner (p < 0.001) and use of protective coil embolization (p = 0.019). Predictors of clinical outcome included initial prostate size (dichotomized into groups > 80 ml and = <80 ml, d = 1, p = 0.0138), embolic agent (spherical particles < 300 nm performed best, p = 0.01) and number of arteries embolized (IPSS reduction of 32.9% in unilateral PAE versus 54.4% for bilateral PAE, p = 0.026). Conclusion: We have identified several important factors which are associated with improved clinical outcome and increased patient dose which we hope will facilitate optimal patient selection and encourage improved embolization technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Data-Informed Evaluation Framework for Integrated Energy Systems: Insights from Power, Process Heat, and Hydrogen Production Applications

The multi-criteria decision analysis (MCDA) framework provides a systematic evaluation of the diverse preferences and performance metrics associated with alternative solutions. This approach is advantageous over a single-criterion methodology, which are only valid under conditions that assume ceteris paribus or an "apples-to-apples" comparison. However, selecting suitable technologies for integrated energy systems (IES) can be likened to an "apples-to-oranges" comparison, given the heterogeneous factors at stake. These factors include economics and performance parameters, geological compatibility, and environmental impacts. Consequently, past research has often employed a mixture of qualitative and quantitative criteria tailored to the specific interests of each study. While the method proves effective in handling the intricate interplay of criteria, the resulting rankings and scores can vary from study to study. This inconsistency is introduced from the use of subjectively defined thresholds and weights. As a result, decision-makers frequently find it challenging to establish clear connections between specific criteria and the resulting scores, as the transformation of criteria into ordinal scores results in a substantial loss of information. To address this challenge, we introduce a data-informed IES evaluation framework that offers comprehensive, interpretable, and traceable evaluations backed by quantifiable rationale. First, we identified key IES evaluation criteria from a decade of literature, focusing on relevant IES applications in power, process heat, and hydrogen production. We leveraged state-of-the-art cost estimates from the Idaho National Laboratory (INL) and technical data from 78 reactor designs from the International Atomic Energy Agency (IAEA) and the Organization for Economic Co-operation and Development - Nuclear Energy Agency (OECD-NEA). Lastly, we established thresholds by analyzing the mean, variance, root mean square, and slope of values across alternatives, categorizing the preferences of decision-makers into distinct utility functions, such as linear, saturating, exponential, and stepwise. Our approach yielded two main outcomes: (1) it provided consistent assessments across different stakeholder groups and (2) it visualized uncertainties in the decision-making context via comprehensive sensitivity analysis. To demonstrate the impact of our framework, we conducted case studies on 6 reactor designs (AP1000, NuScale, BWRX-300, Xe-100, eVinci, iMSR) for the three applications. Our data-driven framework proved to be highly effective in addressing heterogenous uncertainties faced by varied decision-makers? preferences and IES applications, as well as cost and technical estimates of advanced reactors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Data-Informed Evaluation Framework for Integrated Energy Systems: Insights from Power, Process Heat, and Hydrogen Production Applications

The multi-criteria decision analysis (MCDA) framework provides a systematic evaluation of the diverse preferences and performance metrics associated with alternative solutions. This approach is advantageous over a single-criterion methodology, which are only valid under conditions that assume ceteris paribus or an "apples-to-apples" comparison. However, selecting suitable technologies for integrated energy systems (IES) can be likened to an "apples-to-oranges" comparison, given the heterogeneous factors at stake. These factors include economics and performance parameters, geological compatibility, and environmental impacts. Consequently, past research has often employed a mixture of qualitative and quantitative criteria tailored to the specific interests of each study. While the method proves effective in handling the intricate interplay of criteria, the resulting rankings and scores can vary from study to study. This inconsistency is introduced from the use of subjectively defined thresholds and weights. As a result, decision-makers frequently find it challenging to establish clear connections between specific criteria and the resulting scores, as the transformation of criteria into ordinal scores results in a substantial loss of information. To address this challenge, we introduce a data-informed IES evaluation framework that offers comprehensive, interpretable, and traceable evaluations backed by quantifiable rationale. First, we identified key IES evaluation criteria from a decade of literature, focusing on relevant IES applications in power, process heat, and hydrogen production. We leveraged state-of-the-art cost estimates from the Idaho National Laboratory (INL) and technical data from 78 reactor designs from the International Atomic Energy Agency (IAEA) and the Organization for Economic Co-operation and Development - Nuclear Energy Agency (OECD-NEA). Lastly, we established thresholds by analyzing the mean, variance, root mean square, and slope of values across alternatives, categorizing the preferences of decision-makers into distinct utility functions, such as linear, saturating, exponential, and stepwise. Our approach yielded two main outcomes: (1) it provided consistent assessments across different stakeholder groups and (2) it visualized uncertainties in the decision-making context via comprehensive sensitivity analysis. To demonstrate the impact of our framework, we conducted case studies on 6 reactor designs (AP1000, NuScale, BWRX-300, Xe-100, eVinci, iMSR) for the three applications. Our data-driven framework proved to be highly effective in addressing heterogenous uncertainties faced by varied decision-makers? preferences and IES applications, as well as cost and technical estimates of advanced reactors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

DNDO Analysis Cell Concept

The Domestic Nuclear Detection Office (DNDO) has a mission of implementing rad/nuc interdiction capabilities for a managed and coordinated response to threats, integration of federal nuclear forensics programs, and coordinating the development of the global nuclear detection and reporting architecture. In the process of executing this mission, DNDO has generated substantial information, data, technical results, operational workflows and analytical tools. The effective utilization of these resources is an overarching goal of the organization. After nearly a decade of performing work, DNDO faces a challenge in capitalizing on the large amount of data, reports, processes, tools, and people. As new work is being planned, managers and researchers need to have an understating of what information has been collected, what tools are available, the collaborations which can be utilized to propel the work forward, processes to plan and execute, and how to present conclusions and results that can assist the government in making decisions. This type of challenge can be met through the use of a series of organized and connected elements which form a broader structure (cell) that promotes cross utilization of elements such that they can be tailored (analyzed) to fit the context of the problem to be solved. The development of an analysis cell for DNDO will address the challenges of utilizing existing elements, identifying gaps, annually reporting the performance of rad/nuc interdiction instrumentation, and planning the execution of future work.

Pagh, Richard T.↗

FY25 Ion Exchange Processing for the West Area Risk Management (WARM) Project

The West Area Risk Management (WARM) Project was established to enable near-term retrieval and pretreatment of tank waste from Hanford’s 200 West Area and to support deployment of an ion exchange (IX) system capable of producing cesium-depleted supernate suitable for offsite treatment and disposal. The WARM experimental campaign was designed to provide key data for design and operational planning of the 200 W IX system, which plans to utilize crystalline silicotitanate (CST) as the active media for cesium removal. This report documents a comprehensive FY25 experimental campaign designed to produce key technical data required for design and operational planning of the WARM IX system. Testing includes assessing Cs and Sr breakthrough performance in a 4-column system, Cs capacity batch contact testing, phosphate precipitation assessments, reduced-hydroxide feed displacement evaluation, and Sr speciation impacts on Sr removal. The experimental results provide detailed trends in Cs and Sr loading behavior, breakthrough performance across a 4-column staged IX system, distribution profiles within CST beds, and projections of operational flowrates relative to Waste Acceptance Criteria (WAC) limits. Batch contact testing established equilibrium partitioning behavior for the S1–S5 simulants and characterized how matrix chemistry influenced Cs sorption onto CST. Additionally, further evaluations on waste matrix as it pertains to precipitation potential were also determined. Collectively, these datasets support engineering design choices for WARM system throughput and pretreatment planning.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of Patient Dose in Two-Dimensional Carotid Arteriography and Three-Dimensional Rotational Angiography

Background and Purpose. It is known that interventional neuroradiology (IN) involves high radiation dose to both patients and staff even if performed by trained operators using modern fluoroscopic X-ray equipment and dose-reducing technology. Therefore, every new technology or imaging tool introduced, such as three-dimensional rotational angiography (3D RA), should be evaluated in terms of radiation dose. 3D RA requires a series with a large number of images in comparison with 2D angiography and it is sometimes considered a high-dose IN procedure. The literature is scarce on the 3D RA radiation dose and in particular there are no data on carotid arteriography (CA). The aim of this study was to investigate patient dose differences between 2D and 3D CA. Methods. The study included 35 patients undergoing 2D CA in hospital 1 and 25 patients undergoing 3D CA in hospital 2. Patient technical data collection included information on the kerma area product (KAP), fluoroscopy time (T), total number of series (S), and total number of acquired images (F). Results. Median KAP was 112 Gy cm{sup 2} and 41 Gy cm{sup 2} for hospitals 1 and 2, respectively, median T was 8.2 min and 5.1 min, median S was 13 and 4, and median F was 247 and 242. Entrance surface air-kerma rate, as measured in 'medium' fluoroscopy mode measured in 2D acquisition using a 20 cm phantom of polymethylmethacrylate, was 17.3 mGy/min for hospital 1 and 9.2 mGy/min for hospital 2. Conclusion. 3D CA allows a substantial reduction in patient radiation dose compared with 2D CA, while providing the necessary diagnostic information.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Streamlining analysis capabilities for SNF management - 15490

A comprehensive, integrated data and analysis tool-the Used Nuclear Fuel-Storage, Transportation and Disposal Analysis Resource and Data System (UNF-ST and DARDS) -is being developed for the US DOE Office of Nuclear Energy (DOE-NE) Nuclear Fuels Storage and Transportation Planning Project (NFST). The overarching goal of UNF-ST and DARDS is to provide a comprehensive controlled source of technical data integrated with key analysis capabilities to characterize inputs to the overall US waste management system from reactor power production through ultimate disposition. UNF-ST and DARDS seamlessly integrates a unified SNF system relational database and key analysis capabilities to simplify and automate the performance of accurate and efficient SNF related analyses to support numerous DOE waste management and fuel cycle activities. Hence, UNF-ST and DARDS enables decision making relative to design, safety, and licensing of SNF systems and facilities by providing the best information available. Automated analysis sequences have been deployed to characterize the discharge inventory and perform criticality, thermal, and dose analyses using time-dependent data. UNF-ST and DARDS provides cask-specific as-loaded safety analysis including criticality, thermal and dose evaluations, as well as results visualization. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

(Oxy)hydroxides Formed on Aluminum Fuel Materials After Irradiation and Long-Term Wet Storage - 20354

The aluminum cladding of research-reactor fuel experiences general corrosion when in contact with water during in-reactor service and post-discharge wet storage, resulting in the formation of adherent aluminum (oxy)hydroxide films. These (oxy)hydroxides contain chemically-bound water that poses challenges for extended dry storage due to the risk of thermal or radiolytic decomposition releasing free water and/or hydrogen and oxygen gases. This study describes characterization of the (oxy)hydroxides present on several aluminum materials used in reactor operation and subsequently stored wet in the L-Basin storage facility at the Savannah River Site (SRS) for an extended period. Characterization data providing insight into the loading, composition, and morphology of (oxy)hydroxides to be expected on service-exposed aluminum cladding provides valuable benchmarks for designing adequate drying and dry-storage approaches. This work is part of a broader investigation to address knowledge gaps and technical data needs for dry storage of aluminum-clad spent nuclear fuel (ASNF), which included in-lab growth of (oxy)hydroxide films on aluminum alloy substrates to investigate formation behavior, investigation of drying methods to remove existing (oxy)hydroxides from ASNF cladding, and measurement of radiolytic yield of hydrogen from (oxy)hydroxide powders and films. In this study, (oxy)hydroxide films were characterized for three aluminum-alloy materials used in reactors and subsequently stored wet for up to approximately 40 years in L-Basin at SRS: one cropping from a Missouri University Research Reactor (MURR) fuel element (Al-6061 alloy), one cropping from a Universal Sleeve Housing (USH) (Al-6063 alloy), and one Mark-16B fuel assembly (either Al-6061 or Al- 6063). The USH and Mark-16B were used in SRS production reactors. Characterization of the as-received (oxy)hydroxides included scanning electron microscopy (SEM) in both plan-view and cross-section to characterize the (oxy)hydroxide layer's morphology, thickness, and structure. X-ray diffraction (XRD) was used to identify the chemical composition and distinguish between the various aluminum (oxy)hydroxides known to form under reactor and storage conditions. XRD analysis revealed both bayerite (Al(OH)3) and boehmite (AlOOH) on the surface of the MURR and USH samples, as well as bayerite, boehmite, and gibbsite (another Al(OH)3 polymorph) on the surface of the Mark-16B sample. The aluminum trihydroxides, bayerite and gibbsite, are typically associated with corrosion in low-temperature (<80 deg. C) water, while boehmite is expected to form at higher water temperature (>80 deg. C). The presence of bayerite on the USH, which is believed to have operated close to 90 deg. C, suggests that boehmite formed during in-reactor exposure was not protective against further hydroxide growth in low-temperature wet storage. Cross-section scanning electron microscopy (SEM) showed total (oxy)hydroxide layer thicknesses of ∼5- 10 μm for the MURR and ∼5-15 μm for the Mark-16B. The thickness of the USH's (oxy)hydroxide layer was indiscernible by the current mounting and imaging method, despite plan-view SEM and XRD confirming the presence of an (oxy)hydroxide layer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗