Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermal Control System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Thermal Management of Wide-Bandgap Semiconductor Amplifiers Used for Plasma Heating and Control

Princeton Fusion Systems (PFS) has designed, built, and tested a Load Switch printed circuit board (PCB) to demonstrate the capabilities of 2 kV silicon carbide (SiC) cascodes in development by Qorvo towards plasma heating and control applications. Initial tests have been conducted at low power (~100 W) for validation with thermal finite element analysis (FEA) modeling performed by the National Renewable Energy Laboratory (NREL). Comparisons of experimental data with the thermal modeling results, along with considerations for operating in plasma systems, will be discussed.

CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND SU↗

Hardware-Based Demonstration of Temperature Control Functions for Reactor Systems

Establishing autonomy in reactor control systems has become essential for the expansion of nuclear technologies. Thermal regulation in particular remains crucial for maintaining stable operation and ensuring the integrity of fuel. To alleviate public skepticism of the safety of nuclear reactors, demonstrating control over this key factor is pivotal. Utilizing electric heat pads to simulate the heat released in a reactor core, thermocouples for temperature monitoring, and an Arduino micro programmable logic controller (PLC) for control, a hardware-based demonstration of a reactor heating system validates the efficacy of reactor control over this key parameter. To improve precision, a proportional-integral-derivative (PID) algorithm was implemented in the heating control loop to ensure meticulous control of reactor functions. In addition, the integration of this physical system with a digital simulator tool such as RELAP5-3D establishes a foundation for a comprehensive testing environment. This allows for a refinement of temperature control under various simulated reactor conditions, bringing another layer of reliability to the operation of the system. By facilitating a physical demonstration of reactor thermal management and control strategies, this project provides a foundation for expanded testing and educational outreach. Ultimately, this system advances the broader goal of demonstrating the safety and viability of autonomous reactor operations, contributing to public trust and future reactor deployment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal Modeling and Simulation of the Packed-bed Thermal Energy Storage Combined with INL Thermal Energy Distribution System

Dynamic Energy Transport and Integration Lab (DETAIL) at Idaho National Laboratory is to support experimental demonstration and validation research on Nuclear-Renewable Hybrid Energy System [1]. The Thermal Energy Distribution System (TEDS) is a thermal-hydraulic flow loop in DETAIL with its own dedicated control system to support the integration of co-located multiple experimental systems, where a packed-bed thermal energy storage (TES) is installed as a thermal buffer and storage unit. Among various TES options, the packed-bed TES is adopted in TEDS because it offers a low-cost single-tank thermal storage option compared to the traditional two-tank TES. However, since the TES tank is filled with granular fillers having different thermophysical properties from those of TES tank wall, there is a potential thermo-mechanical issue to be carefully addressed like thermal ratcheting which may pose a significant design concern for the packed-bed TES tank. Thermal ratcheting is a thermomechanical process caused by the repeated rearrangement of granular filler inside a TES tank during continuous thermal cycling operation of the packed-bed TES system. If the thermally induced stress exceeds the yield strength of a TES tank wall, catastrophic consequences may happen like rupture of the TES tank. Thus, it is important to understand the phenomenon to ensure the robust operation of the packed-bed TES tank. Given that thermal ratcheting is caused by complex interaction of thermal transport in the porous bed and solid mechanics, the accurate prediction of transient thermal behavior of the packed-bed TES tank, which is the focus of this paper, is critical to the reliable thermal ratcheting analysis. This paper discusses the numerical modeling, simulation, and validation studies that are ongoing at INL to investigate the transient thermal behavior of the packed-bed TES. Of particular concern is the transient thermal process occurring in the packed-bed TES unit that is operated in conjunction with the INL TEDS. The main goal of this research is three-fold: (i) provide preliminary insights into the transient thermal behavior of the TEDS TES tank, (ii) support the thermal measurement and validation plan for TEDS experiment, and (iii) provide transient thermal boundary conditions to support the reliable thermal ratcheting analysis of the TEDS TES tank. For the transient thermal modeling and analysis, a CFD model was developed, and the validity of the modeling approach was examined via comparing the numerical simulation results with the experimental data obtained from various design characteristics of packed-bed TES tanks. Then, the present modeling method was applied for the transient thermal analysis of the TEDS TES tank, and the results are discussed along with the potential improvement of data acquisition strategy for the future TEDS experiments for more precise validation study.

25 ENERGY STORAGE↗

Advanced HVAC Humidity Control for Hot-Humid Climates

During this project we develop and validate a cost-effective, integrated control solution to improve humidity control and comfort for energy-efficient homes in hot-humid climates. This study focuses on developing a strategy that is effective, field tested, and practical for builders to install with minimal disruption to standard practices. A successful solution would simplify the transition to high-performance humidity control and be the basis for design and installation guidance. By relying on the central system as a starting point, the strategy employed minimizes system complexity and cost for builders, while improving comfort and operating cost for homeowners. The solution strategy was to coordinate the cooling, dehumidification, and ventilation functions of central, ducted HVAC systems to better control indoor humidity, improve occupant thermal comfort, and capture energy savings. The primary strategic goals were to: (1) optimize dehumidification by the central air-conditioning system, particularly during part-load conditions, using conventional equipment with modified control settings and lower system airflows; (2) maximize ventilation during heating/cooling on-cycles, to “bank” and condition outdoor ventilation air, and minimize ventilation during off-cycles; (3) quantify the effectiveness and energy impact of the dehumidification and ventilation strategies, while identifying a metric that would be useful to evaluate latent effectiveness. For the test houses in our study, located in Richmond Hill, Georgia; Houston, Texas; and Monroe, Louisiana we observed: (1) the indoor humidity did not exceed 60% RH during the monitored cooling season for 99% of the time in Richmond Hill, 96% of the time in Houston, and 90% of the time in Monroe; (2) the dehumidification strategy improved the steady-state latent capacity of the HVAC system at design conditions by 16% to 49% at the Houston test house and by 28% to 71% at the Monroe test house, depending on which mode the system was operating in; and (3) the good results at the test houses were primarily due to the amount of time the air-conditioning system operated in ramping or dehumidification modes, or both, particularly during the early cooling season. This study demonstrates that air conditioners or heat pumps with a single-stage compressor can provide good humidity control without the need for a two-stage or variable-stage compressor system. The airflow and control settings for ramping and dehumidification modes are critical to control indoor humidity in hot-humid climates, particularly during part-load and shoulder season conditions. The dehumidification strategy used in this study did not jeopardize the mechanical reliability of the cooling equipment. The strategies used in this study are applicable across various equipment brands, models, and efficiency levels, and also applicable to a broad range of homes in hot-humid climates. Results will vary by specific equipment, location, and house configuration and construction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Temperature‐Dependent Crystallization in Two‐Step Perovskite Deposition Revealed by In Situ GIWAXS and Machine Learning‐Guided Analysis

The performance and stability of perovskite solar cells are strongly governed by the crystallization behavior of their active layer. In two-step sequential deposition, early-stage film formation plays a decisive role in determining final phase purity and device quality. Guided by a data-driven analysis of nearly 39 000 devices in the FAIR perovskite database, we identified solvent-mediated quenching and thermal processing as key variables affecting power conversion efficiency (PCE), particularly in two-step fabrication. Here, to investigate these effects in real time, we designed and implemented a custom-built, temperature-controlled spin-coating system, enabling precise thermal modulation during precursor deposition. Using this platform, we performed in situ GIWAXS measurements to study the crystallization dynamics of FA 0.5 MA 0.5 PbI 3 films over a temperature range of 30°C–90°C. Our results reveal a non-monotonic relationship between spin-coating temperature and α-phase formation, governed by the interplay between precursor interdiffusion, PbI 2 crystallinity, and δ-phase suppression. The custom thermal control enabled us to isolate and quantify these competing effects during the earliest stages of film formation, providing mechanistic insight into how spin-coating temperature governs both phase purity and kinetic pathways in two-step perovskite systems. Temperature-dependent SEM and photovoltaic device measurements further demonstrate that early-stage crystallization pathways directly translate into differences in morphology, charge-transport continuity, and device performance. These findings inform targeted strategies for optimizing deposition protocols to balance rapid nucleation, phase stability, and device performance.

Saadawy, Ahmed [King Fahd University of Petroleum ↗

Modifications to the Thermal Energy Distribution System (TEDS)

INL installed a new controls system and a flame detection system on TEDS as part of upgrades that will eventually allow unattended operation and integration with accessory systems, such as digital twins, or facilities in other locations. These upgrades resolve some corrective actions that came about when oil was spilled from a high-point vent during system startup testing.

42 ENGINEERING↗

Cooling charge determination for a local thermal management system

A system and method for estimating the state of charge, i.e., the amount of cooling remaining, in a latent heat thermal storage module of a local environmental control system. The local environmental control system stores cooling energy at night by freezing a latent heat phase change material (PCM), and then releasing the stored cooling energy by removing heat from room air flowing through the PCM during the day. Differential temperature sensors are used measure the air temperature drop across the latent thermals storage unit and the fan voltage, which is directly related to fan air flow rate, is sampled. A controller is programmed to determine the charging state from these measurements.

Khalifa, H. Ezzat↗

Nuclear Safety [Vol. 30, No. 3, July-September 1989]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 325 Safety of Framatome Advanced Nuclear Steam Supply Systems Designs by J. A. Charles and D. Lange, 333 Book Review of Nuclear Accidents: Intervention Levels for the Protection of the Public by H. B. Piper; ACCIDENT ANALYSIS: 335 Living PRA Computer Systems by S. C. Dinsmore and H.-P. Balfanz, 343 Summary of ICAP Assessments of RELAP5/MOD2 by W. E. Driskell and R. G. Hanson; CONTROL AND INSTRUMENTATION: 352 Thermal Performance Monitoring System at Maanshan Nuclear Power Plant by H.-J. Chao, Y.-P. Lin, G.-H. Jou, L.-Y. Liao, and Y.-B. Chen; DESIGN FEATURES: 358 Warning Systems for Nuclear Power Plant Emergencies by J. H. Sorensen and D. S. Mileti; WASTE AND SPENT FUEL MANAGEMENT: 371 Activities Related to Waste Management Compiled by E G. Silver; OPERATING EXPERIENCES: 382 Steam Generator Tube Performance: Experience with Water-Cooled Nuclear Power Reactors During 1985 by O. S. Tatone and R. L. Tapping, 400 Systems Interaction Analyses: Concepts and Techniques (Part II) by M. D. Muhlheim and G. A. Murphy, 413 Reactor Shutdown Experience Compiled by J. W. Cletcher, 416 Operating U.S. Power Reactors Compiled by E G. Silver; RECENT DEVELOPMENTS: 440 General Administrative Activities Compiled by E G. Silver, 460 Reports, Standards, and Safety Guides by D. S. Queener, 466 Status of Power-Reactor Licensing Activities Compiled by E G. Silver, 470 Proposed Rule Changes as of Mar. 31, 1989; ANNOUNCEMENTS: 334 Proceedings Published, 351 CEC Seminar on Methods and Codes for Assessing the Off-Site Consequences of Nuclear Accidents, 357 Short Course on Multiphase Flow and Heat Transfer: Bases and Applications in A: The Nuclear Power Industry B: The Process Industries, 357 International Conference on Probabilistic Safety Assessment and Management, 478 International Topical Meeting on the Safety, Status, and Future of Non-Commercial Reactors and Irradiation Facilities, 475 The Authors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nuclear Safety [Vol. 30, No. 3, July-September 1989]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 325 Safety of Framatome Advanced Nuclear Steam Supply Systems Designs by J. A. Charles and D. Lange, 333 Book Review of Nuclear Accidents: Intervention Levels for the Protection of the Public by H. B. Piper; ACCIDENT ANALYSIS: 335 Living PRA Computer Systems by S. C. Dinsmore and H.-P. Balfanz, 343 Summary of ICAP Assessments of RELAP5/MOD2 by W. E. Driskell and R. G. Hanson; CONTROL AND INSTRUMENTATION: 352 Thermal Performance Monitoring System at Maanshan Nuclear Power Plant by H.-J. Chao, Y.-P. Lin, G.-H. Jou, L.-Y. Liao, and Y.-B. Chen; DESIGN FEATURES: 358 Warning Systems for Nuclear Power Plant Emergencies by J. H. Sorensen and D. S. Mileti; WASTE AND SPENT FUEL MANAGEMENT: 371 Activities Related to Waste Management Compiled by E G. Silver; OPERATING EXPERIENCES: 382 Steam Generator Tube Performance: Experience with Water-Cooled Nuclear Power Reactors During 1985 by O. S. Tatone and R. L. Tapping, 400 Systems Interaction Analyses: Concepts and Techniques (Part II) by M. D. Muhlheim and G. A. Murphy, 413 Reactor Shutdown Experience Compiled by J. W. Cletcher, 416 Operating U.S. Power Reactors Compiled by E G. Silver; RECENT DEVELOPMENTS: 440 General Administrative Activities Compiled by E G. Silver, 460 Reports, Standards, and Safety Guides by D. S. Queener, 466 Status of Power-Reactor Licensing Activities Compiled by E G. Silver, 470 Proposed Rule Changes as of Mar. 31, 1989; ANNOUNCEMENTS: 334 Proceedings Published, 351 CEC Seminar on Methods and Codes for Assessing the Off-Site Consequences of Nuclear Accidents, 357 Short Course on Multiphase Flow and Heat Transfer: Bases and Applications in A: The Nuclear Power Industry B: The Process Industries, 357 International Conference on Probabilistic Safety Assessment and Management, 478 International Topical Meeting on the Safety, Status, and Future of Non-Commercial Reactors and Irradiation Facilities, 475 The Authors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparative Analysis of Model Predictive Control and MPC-Informed Rule-Based Control for Thermal Storage Operation in Ultra-Low Temperature 4th Generation District Heating Networks

The integration of thermal storage and heat pumps in district heating networks (DHNs) can significantly enhance operational flexibility and energy efficiency; however, the practical deployment of advanced control strategies is often hindered by forecasting requirements and computational complexity. This study presents a comparative analysis of thermal storage control strategies in an ultra-low-temperature fourth-generation DHN, focusing on the development of a simplified rule-based control (RBC) explicitly informed by Model Predictive Control (MPC) behavior. The proposed methodology systematically analyzes the charging and discharging decisions of an MPC-controlled system under ideal forecasting conditions and extracts recurrent control patterns as a function of key system variables, including outdoor temperature, thermal demand, and electricity price. These patterns are translated into a set of structured time- and condition-based rules, resulting in an MPC-informed RBC that embeds predictive insights while preserving implementation simplicity and operational transparency. The approach is validated on a realistic mixed-use urban district in Denver, Colorado, USA, equipped with a centralized air-source heat pump, distributed water-to-water heat pumps, and a central thermal storage unit. Results show that the tuned RBC attains approximately 96% of ideal MPC economic performance (-27% of costs), preserves values of technical and environmental indicators (reduction only of 2-3%), and substantially reduces complexity. Sensitivity analyses further demonstrate the robustness of the RBC under varying operational conditions (i.e., ambient temperature, electricity price). Overall, the study demonstrates that MPC-informed rule-based control represents an effective trade-off between control performance and real-world applicability, enabling the integration of additional system components while maintaining simplicity, robustness, and ease of implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Educational Program on Concentrated Solar Power and Heliostats for Power Generation and Industrial Processes

The objective of this project was to design and implement a comprehensive educational and applied research program in Concentrated Solar Thermal Power (CSTP) and heliostat technologies at Northeastern University. In alignment with the U.S. Department of Energy's Heliostat Consortium (HelioCon) goals, the project aimed to expand student and public understanding of CSTP systems while simultaneously contributing to workforce development and the broader decarbonization strategy. A particular emphasis was placed on integrating hands-on student design projects and publicly disseminating educational content relevant to CSTP systems. The project addressed a critical gap in renewable energy education: CSTP and heliostats, despite their importance in utility-scale solar energy, are rarely included in standard mechanical engineering programs. This project established new pathways for students to engage with the topic through the creation of a 4-credit graduate/senior elective course, development of five industry-facing short courses, and the inclusion of CSTP-based capstone design projects. Over two academic years, 36 students across six senior design teams developed and tested technologies such as deformable heliostats, beacon-based tracking systems, and solar-powered pyrolizers for biomass-to-biochar conversion. Concurrently, 30 undergraduate and graduate students were enrolled in the new academic course centered around CSTP principles. To ensure the relevance and accessibility of the short course content, the project team engaged with industry professionals, technical policy stakeholders, and potential course participants through structured surveys and informal consultations. Feedback from 28 respondents guided the structure, length, and delivery format of the courses - resulting in a modular design broken into five workshops. The feedback emphasized the need for flexible, asynchronous delivery and practical case studies, particularly in areas such as heliostat control, thermal storage, and solar fuel production. This engagement helped align the courses with the evolving knowledge demands of the renewable energy workforce and ensured that participants from both technical and policy backgrounds could meaningfully benefit from the material. The research and educational activities advanced the understanding of heliostat control systems, optical performance under misalignment, and thermal system integration in solar-driven pyrolysis applications. Methods and designs explored in this project proved to be both technically effective and economically feasible at the lab scale. Prototypes were constructed using commercially available components and custom-fabricated elements, demonstrating that meaningful performance improvements can be achieved with modest material and fabrication costs, supporting the feasibility of student-led research in this field. The public benefit of this project is twofold. First, it cultivates a pipeline of engineers trained to be familiar with CSTP principles, an essential workforce need identified by the Department of Energy for achieving its 2030 cost and deployment targets. Second, it contributes openly accessible educational materials, course content, and experimental frameworks to the broader community, enabling other institutions to adopt or adapt similar programming. Through outreach activities, curriculum integration, and technical exposure, this project contributes to a more informed and capable renewable energy workforce while supporting innovation in heliostat and CSTP system design. A new technical report is being prepared to document the development of the course and its outcomes, with plans to publish it in the ASME Open Access Journal of Engineering to ensure global accessibility, free of cost.

14 SOLAR ENERGY↗

Flexible Plant Operation and Generation Technical Program Plan for FY2023

This report presents the Technical Program Plan for Fiscal Years 2023-2027 (FY2023 to FY2027) for the U.S. Department of Energy (DOE) Light Water Reactor Sustainability Program—Flexible Plant Operation and Generation Research Pathway. The objective of this pathway is to carry out the research needed to help nuclear power plants diversify revenue generation for the life of these plants. The purpose of these research and development activities is two fold: (1) to reduce the technical and economic risks of implementing FPOG applications and (2) to provide guidance on relevant safety and environmental operating license reviews, amendments, and renewals. This pathway provides a clear understanding of the benefits of nuclear energy beyond electricity markets. A detailed description of the research and development activities that have been completed and that are planned for FY2023—FY2027 are presented in this report. These activities include completing the development of analysis tools to perform technical and economic assessments of realistic market opportunities for producing secondary energy products near nuclear power plants. They also include developing and demonstrating engineering systems and control concepts to dispatch thermal and electrical power to an industrial user. Additionally, this plan includes developing guidance for addressing potential regulatory and licensing requirements. In addition, the formation, purpose, and activities of a group referred to as the Hydrogen Regulatory Research and Review Group is discussed. An overview is also provided on the potential benefits of the Infrastructure Investment and Jobs Act (IIJA) Bill that will support the commencement of Regional Clean Hydrogen Hubs, and the Inflation Reduction Act (IRA) that provides compelling production tax credits for nuclear electricity and clean hydrogen using nuclear energy.

08 HYDROGEN↗

Recent Advancements and Prospects of Chemical Heat Pumps for Temperature Amplification for Nuclear Process Heat Applications

The energy economy is continually evolving, particularly in terms of primary energy sources, their conversions to useful forms such as electricity and heat, and their utilization in different sectors, in response to socio-political factors. Because nuclear energy source is a clean and non-carbon-emitting energy source, it is crucial to consider its role in the evolution of the energy economy. Integrated Energy Systems (IES) are collaboratively controlled systems that can dynamically apportion thermal and/or electrical energy to promote the production of various energy products and have the potential to reduce greenhouse gas (GHG) emissions, improve energy efficiency, improve electrical grid dependability, and enhance energy economics. To realize the benefits of IES with the current reactor fleets, selection and development of a complimentary temperature upgrading technology are necessary for providing process heat and improving economics.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

COR-0011 Rev 6 MARVEL Project Code of Record

This Code of Record identifies the codes, standards, and procedures necessary to design, develop, construct, and startup the Microreactor Applications Research Validation and Evaluation (MARVEL) Project at the Materials and Fuel Complex (MFC) Transient Reactor Test (TREAT) Facility and the Idaho National Laboratory (INL). The MARVEL Project is an INL test microreactor funded by the United States Department of Energy (DOE) via the Microreactor Program (MRP). The goal of the project is to establish an operational nuclear applications test bed that can generate combined heat and power to enable integration and R&D with end-user technologies, as well as allow microreactor technologists to test next-generation control systems. The microreactor is a thermal reactor utilizing Uranium Zirconium Hydride (UZrH) fuel with review and authorization by the Department of Energy Idaho Operations Office (DOE-ID) for National Environmental Policy Act (NEPA) compliance, safety review, and supplemental readiness assessments for startup and operation. To enable rapid deployment, the MARVEL reactor will reside in the Transient Reactor Test (TREAT) Facility and utilize the existing operating Category B reactor facility, approved facility safety basis, operating crews, and recent re-start experience.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

CityLearn v2: energy-flexible, resilient, occupant-centric, and carbon-aware management of grid-interactive communities

As more distributed energy resources become part of the demand-side infrastructure, quantifying their energy flexibility on a community scale is crucial. CityLearn v1 provided an environment for benchmarking control algorithms. However, there is no standardized environment utilizing realistic building-stock datasets for distributed energy resource control benchmarking without co-simulation or third-party frameworks. CityLearn v2 extends CityLearn v1 by providing a stand-alone simulation environment that leverages the End-Use Load Profiles for the U.S. Building Stock dataset to create grid-interactive communities for resilient, multi-agent, and objective control of distributed energy resources with dynamic occupant feedback. While the v1 environment used pre-simulated building thermal loads, the v2 environment uses data-driven thermal dynamics and eliminates the need for co-simulation with building energy performance software. This work details the v2 environment and provides application examples that use reinforcement learning control to manage battery energy storage system, vehicle-to-grid control, and thermal comfort during heat pump power modulation.

Nweye, Kingsley↗

An Efficient Annual-Performance Model of a Geothermal Network for Improved System Design, Operation, and Control: Preprint

Geothermal district energy systems (DES), and specifically geothermal networks, provide a viable solution for decarbonizing residential and commercial heating and cooling loads. District energy systems of all kinds enable a thermal resource with a relatively high capital cost (such as a geothermal borehole field) to be shared among a large number of users. While district heating and cooling has been studied for many years, geothermal networks, fifth generation DES that utilize water-source heat pumps and an ambient temperature loop to meet heating and cooling loads, have not been implemented extensively and thus require additional technical and economic optimization to obtain maximum benefits. This paper presents a newly developed reduced-order model that captures the flow of energy within the network, including the commercial and residential users' electrical usage, at an hourly rate over a year. The model includes building loads, heat pumps, borehole fields, and auxiliary heat/cool input, all connected with an ambient-temperature thermal loop model. In the model, operational control is possible for the borehole fields, circulation pump, and auxiliary system. For a given system, the model can output the complete state parameters for each component, the thermal loop, and the collective system, such as flow rate over time, average thermal loop temperature over time, and total electricity usage. The model can also be used to optimize the system control for maximizing system efficiency or minimizing system operational cost. For example, one initial assessment of the borehole controller for an example system showed that a controller with on/off operation of the borehole field reduces annual electrical usage by 33%, compared with continuous operation mode. Hence, the model can assist in optimizing a given system's operation to get the most value out of a geothermal network installation. Future work will consider the model's application to a demonstration project, including the model validation against operational data and system operation optimization.

ambient-temperature loop↗