Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermal Power Dispatch System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Off-design performance of molten salt-driven Rankine cycles and its impact on the optimal dispatch of concentrating solar power systems

This paper presents a model for improving off-design performance predictions for molten salt-driven Rankine power cycles, such as in concentrating solar power tower applications. The model predicts cycle off-design performance under various boundary conditions, including molten salt inlet temperature, mass flow rate, and ambient temperature. The model is validated using industry performance data and benchmarked with results from the literature. A complete concentrating solar power plant, inclusive of solar heliostat field and receiver, is then considered, by implementing the Rankine cycle off-design performance results into the National Renewable Energy Laboratory’s System Advisor Model software, which includes a tool that determines optimal power production schedules. The work improves upon the current System Advisor Model by updating off-design performance characteristics. A case study demonstrates the impact of cycle off-design behavior on annual performance for a stand-alone concentrating solar power system and a concentrating solar power-photovoltaic hybrid system. In addition, we demonstrate how cycle off-design performance influences optimal operator dispatch decisions and, thereby, overall system design and economics. We conclude that off-design cycle performance impacts “optimal” sub-system sizing, especially for a concentrating solar power-photovoltaic hybrid configuration in which concentrating solar power must dispatch in conjunction with photovoltaic generation.

14 SOLAR ENERGY↗

An Enhanced Computational Framework for Energy Storage Participation in Transmission Planning with Electricity Market Participation: Dynamic Market Participation Restriction Estimation

In the previous study and report, we developed a computational framework to explore the technical and economic viability of the dual use of pumped storage hydropower (PSH) for both transmission assets and market participation. The rationale for the dual-use application is to improve the resource utilization rate and reduce the cost recovery burden. A PSH-based transmission solution generally has a large capacity, which corresponds to a higher investment cost compared to a traditional line solution. Market participation may allow the PSH asset to offset part of its high investment cost. A critical question is whether it is economically and technically viable to allow dual use of a PSH-based transmission project without jeopardizing transmission system reliability. And a more specific follow-up question is how to improve market participation performance while maintaining transmission reliability. In this study, we extend the computational framework by updating the method to determine transmission service obligation requirements dynamically based on the possibility of the need for transmission service in operation. Specifically, we correlate the need for transmission service with the probability of thermal overloading on a monitored transmission line, which is essentially based on the probability distribution of power flow and its probability of exceeding the line rating based on system dispatch and operational uncertainties. In addition, the need depends on the level of risk that a system operator is willing to take. The higher the risk tolerance, the lower the requirement that the system operator would apply to the PSH project as a transmission asset. The requirements are updated every day before the PSH project determines its market participation strategy. With the updated transmission service requirements, it is expected that a PSH project can serve as a transmission asset when the transmission system is at risk and really needs it, while it can participate in a market with sufficient information and certain restrictions. In this way, the transmission service quality and market participation performance can both be improved.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Model for Hybrid Systems for Production Cost Modeling Studies Considering Ancillary Services: Preprint

This paper introduces a model for simulating hybrid plants participating in energy and ancillary services for bulk power system studies. The model considers a hybrid plant comprised of a renewable energy source, a thermal power unit, a storage unit, fixed power loads, or any combination of these technologies. The model focuses on Production Cost Modeling (PCM) studies under the assumption of centralized dispatch. We present an example case study to illustrate the use of the model in a single-stage production cost model similar to those conducted by planning agencies. We explore the allocation of behind-themeter ancillary services products and total energy participation to hybrid plant sub-assets and the resulting impacts on the system's ancillary service allocation. The model is implemented and simulated in a unit commitment problem in the RTS test system, which was modified to include a hybrid plant asset.

ancillary services↗

A Model for Hybrid Systems for Production Cost Modeling Studies Considering Ancillary Services

This paper introduces a model for simulating hybrid plants participating in energy and ancillary services for bulk power system studies. The model considers a hybrid plant comprised of a renewable energy source, a thermal power unit, a storage unit, fixed power loads, or any combination of these technologies. The model focuses on Production Cost Modeling (PCM) studies under the assumption of centralized dispatch. We present an example case study to illustrate the use of the model in a single-stage production cost model similar to those conducted by planning agencies. We explore the allocation of behind-the-meter ancillary services products and total energy participation to hybrid plant sub-assets and the resulting impacts on the system's ancillary service allocation. The model is implemented and simulated in a unit commitment problem in the RTS test system, which was modified to include a hybrid plant asset.

ancillary services↗

Multilevel Analysis, Design, and Modeling of Coupling Advanced Nuclear Reactors and Thermal Energy Storage in an Integrated Energy System

This report discusses the different options for coupling thermal energy storage (TES) systems to advanced nuclear power plants (A-NPPs) in order to enable flexible and hybrid plant operation. An advanced light-water reactor (A LWR), a high-temperature gas-cooled reactor (HTGR) and a liquid-metal fast reactor (LMFR) were selected as the initial use cases for demonstrating a thermally balanced energy storage coupling design for thermal power extraction. The models presented herein showcase several design considerations, focusing on optimal deployment methodologies for achieving steady-state and transient-state operation with minimum disruption to the nuclear power cycle. This first part of the study presents steady-state models developed using Aspen HYSYS®, with the thermal energy bypass for NPP-TES coupling being varied at up to 50%. The various components were sized using the Aspen Process Economic Analyzer (APEA) and Aspen Exchanger Design and Rating (EDR), when applicable. Cost functions from these models were developed using the latest publicly available data obtained from APEA V11. The TES-coupled A-NPP steady-state models and cost functions then provided a baseline for dynamic operation and process optimization by using Idaho National Laboratory (INL)’s Framework for Optimization of Resources and Economics (FORCE) tools. A stochastic optimization of the various energy storage systems coupled to the A-NPPs was then performed using the Risk Analysis Virtual Environment (RAVEN) and its dispatch optimization plugin, the Holistic Energy Resource Optimization Network (HERON). The signal processing and synthetic history capabilities of RAVEN were used to account for the unpredictable behavior of electricity markets. An autoregressive moving average (ARMA) model was used to analyze price signals from the Pennsylvania-New Jersey-Maryland (PJM) market and were applied to the HERON analysis in order to optimize a system with the best economics. Transient modeling evaluation was then performed using Modelica models within the HYBRID repository, which was developed at INL for the Department of Energy Integrated Energy Systems program for the characterization of dynamic integrated system behavior and feedback. This includes evaluation of the TES-coupled A-LWR systems’ impact on physical and thermal system response during imposed system demands. Additional TES-coupled reactor types, coupling approaches, markets, and TES technologies will be evaluated in future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High-Temperature Linear Receiver Enabled by Multicomponent Aerogels

Concentrating solar thermal (CST) technology has significant potential mainly due to its dispatchability and low cost of storage. However, to compete with other sources, including utility-scale solar PV, its final cost (cents/kWh) still needs to be lowered. Cost reduction can be achieved by improving the system level efficiency of the CST plants through the deployment of advanced power cycles, which operate at high temperatures of ~700°C. However, optical, and thermal losses pose a major challenge to the efficiency of such CST systems. The overall aim of this project is to investigate and de-risk a linear solar receiver concept called an Aerogel Insulated Receiver (AIR) that generates high temperatures (up to 700°C) at a low solar concentration ratio (<100) and with a high collection efficiency (optical × receiver). Our prior work has demonstrated the thermal stability1 and optical and heat-insulating properties2,3 of transparent aerogel insulation at a one-inch scale. The focus of this work is on (1) co-optimization of the geometry of the aerogel tile and receiver enclosure to fit a standard parabolic collector (PTC), (2) scale-up of aerogels into 4-inch tiles while preserving key properties, (3) experimental measurement of receiver heat loss (W/m) in a >70-cm test stand and validation of anticipated receiver performance at high temperatures. Regarding (1), appropriate optical and thermal models for a parabolic trough receiver (PTR) are developed and validated. The geometry of the aerogels and the receiver enclosure are co-optimized to maximize the collection efficiency. The model predicts a 54% collection efficiency at 700°C for an AIR design based on flat aerogels. By combining the collection efficiency with the power block efficiency of supercritical CO 2 cycles, we predict >10% improvements in peak plant efficiency relative to existing line-focusing CST systems. The application of curved plasmonic aerogels is predicted to further increase the collection efficiency to 64%. Regarding (2), we demonstrate the successful development of 6-inch-long refractory aerogel tiles with optical, thermal, and stability characteristics consistent with our prior work. This scale-up requires a transition to a larger ALD station and modifying the ALD process variables such as exposure time and the number of precursor doses. Regarding (3), we design and develop an AIR test stand measuring 3 feet in length. Heat loss performance analysis is carried out using the test stand. The results indicate that aerogel insulation can significantly reduce receiver thermal losses at the high operating temperatures required for next-generation PTRs. The experimental results agree with the heat loss performance predicted by our receiver model. Lastly, we conducted preliminary failure mode and effects (FMEA) and techno-economic (TEA) analyses to identify failure mitigation strategies and commercial opportunities, respectively. Overall, this project identifies key opportunities and challenges in deploying aerogel insulating receivers in next-generation line-focusing CST technologies.

14 SOLAR ENERGY↗

Thermophotovoltaic efficiency of 40%

Thermophotovoltaics (TPVs) convert predominantly infrared wavelength light to electricity via the photovoltaic effect, and can enable approaches to energy storage and conversion that use higher temperature heat sources than the turbines that are ubiquitous in electricity production today. Since the first demonstration of 29% efficient TPVs (Fig. 1a) using an integrated back surface reflector and a tungsten emitter at 2,000°C (ref. 10), TPV fabrication and performance have improved. However, despite predictions that TPV efficiencies can exceed 50%, the demonstrated efficiencies are still only as high as 32%, albeit at much lower temperatures below 1,300 C (refs. 13,14,15). Here we report the fabrication and measurement of TPV cells with efficiencies of more than 40% and experimentally demonstrate the efficiency of high-bandgap tandem TPV cells. The TPV cells are two-junction devices comprising III–V materials with bandgaps between 1.0 and 1.4 eV that are optimized for emitter temperatures of 1,900–2,400°C. The cells exploit the concept of band-edge spectral filtering to obtain high efficiency, using highly reflective back surface reflectors to reject unusable sub-bandgap radiation back to the emitter. A 1.4/1.2 eV device reached a maximum efficiency of (41.1 ± 1)% operating at a power density of 2.39 W cm –2 and an emitter temperature of 2,400°C. A 1.2/1.0 eV device reached a maximum efficiency of (39.3 ± 1)% operating at a power density of 1.8 W cm–2 and an emitter temperature of 2,127°C. These cells can be integrated into a TPV system for thermal energy grid storage to enable dispatchable renewable energy. This creates a pathway for thermal energy grid storage to reach sufficiently high efficiency and sufficiently low cost to enable decarbonization of the electricity grid.

14 SOLAR ENERGY↗

CSP Plant Optimization Study for the California Power Market (“CalCSP”) (Final Technical Report)

Concentrating Solar Power (CSP) with thermal energy storage offers a unique and strategic opportunity to support California’s clean energy transition. Unlike photovoltaic (PV) systems, CSP with thermal storage can generate electricity after sunset and during periods of high demand, making it a valuable complement to intermittent renewable resources. CSP also provides synchronous, inertia-contributing generation, long-duration storage, and flexible dispatch—capabilities increasingly important as thermal plants retire. This report summarizes the findings of the CSP Plant Optimization Study for the California Power Market or “CalCSP study,” which evaluated the technical, economic, environmental, and policy factors that influence the deployment of CSP technologies in California. The CalCSP study was conducted to assess how CSP can contribute to California’s long-term decarbonization goals while enhancing grid reliability, supporting local economic development, and making efficient use of land and transmission resources. It draws on detailed modeling of CSP performance and costs, site suitability analysis, policy reviews, and stakeholder engagement across utilities, regulators, developers, and community organizations. The analysis focuses on mature molten-salt tower technology and incorporates lessons learned from the global CSP fleet, distinguishing today’s CSP from earlier first-of-a-kind projects in the U.S. The findings support a more prominent role for CSP in California’s evolving clean energy landscape. With strategic planning, targeted policy support, and continued cost improvements, CSP can complement PV and batteries to deliver reliable, around-the-clock clean electricity—especially in areas with high solar resource and constrained grid capacity.

14 SOLAR ENERGY↗

Parametric analysis on optimized design of hybrid solar power plants

There is increasing interest in utility-scale solar power plants with storage which can flexibly dispatch renewable energy to the grid. However, plant design possesses many degrees of freedom and non-obvious trade-offs in performance. Software tools can estimate or optimize the performance of a specific plant configuration under market and weather conditions of interest; the associated cost parameters and operating assumptions strongly influence estimates of plant performance and decisions regarding optimal sizing. We employ the National Renewable Energy Laboratory's Hybrid Optimization and Performance Platform, which incorporates optimal dispatch when evaluating plant performance, and investigate the sensitivity to weather and market conditions, operating limitations, and the presence of a capacity-based incentive. We demonstrate changes in plant performance and optimal sizing with respect to these inputs and discuss implications. Here results show that PV-with-battery designs are more profitable under our assumptions, but that designs including a concentrated solar power (CSP) system produce significantly greater annual energy; and that CSP-with-thermal energy storage designs maximizing the benefit-to-cost ratio have an input-dependent linear relationship between the CSP field solar multiple and the hours of storage as the project budget varies.

14 SOLAR ENERGY↗

FARM supervisory capabilities for thermal energy storage

The FARM (Feasible Actuator Range Modifier) module is a component of the RAVEN-based FORCE framework for the analysis of Integrated Energy Systems (IES). FARM aids HERON in the solution of the power dispatch problem by evaluating feasible set-point signals to be issued to the control systems of the different IES unit components. Set-points need to satisfy limits on both production variables (i.e., the variables to be optimized such as the electrical power, etc.) and process variables tied to the service life of equipment (e.g., steam flowrate, vessel pressure, turbine firing temperature, etc.). To enforce all these limits, a two-stage approach is adopted. First, the power dispatcher algorithm in HERON module estimates set-points that meet the constraints on the production variables, e.g., power levels and power ramp rate limits. These constraints are called explicit constraints. Then, if necessary, FARM adjusts these set-points to ensure the respect of the limits on the process variables of interest, given the knowledge of the system dynamics acquired through machine learning algorithms. These constraints are called implicit constraints. From this standpoint, FARM constitutes a bridge between the HERON power dispatcher that adopts a simplified description of the IES unit (low-resolution physics) and the HYBRID high-fidelity models (high-resolution physics). In this report, an overview of the major capabilities of the latest release of FARM is provided, along with a summary of the tool demonstration campaign conducted at the Dynamic Energy Technology and Integration Laboratory (DETAIL) facility. These results assess the performance of the control system architecture embedding FARM both as a Validator of the HERON power dispatcher and as a real time Supervisory control scheme. Additionally, the report outlines the areas that FARM might benefit from, along with proposed solutions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Spinel Cu–Mn–Cr Oxide Nanoparticle-Pigmented Solar Selective Coatings Maintaining >94% Efficiency at 750 °C

High-temperature concentrating solar power (CSP) system is capable of harvesting and storing solar energy as heat towards cost-effective dispatchable solar electricity. Solar selective coating is a critical component to boost its efficiency by maximizing solar absorptance and minimizing thermal emittance losses. However, maintaining a high solar-thermal conversion efficiency >90% for long-term operation at ≥750 ºC remains a significant challenge. Herein, we report spray-coated spinel Cu-Mn-Cr oxide nanoparticle-pigmented solar selective coatings on Inconel tube sections maintaining ≥94% efficiency at 750 ºC and ≥92.5% at 800 ºC under 1000x solar concentration after 60 simulated day-night thermal cycles in air, each cycle comprising 12h at 750 ºC/800 ºC and 12h cooling to 25 ºC. The solar spectral selectivity is intrinsic to the band-to-band and d-d transitions of non-stoichiometric spinel Cu-Mn-Cr oxide nanoparticles. Furthermore, this feature offers a large fabrication tolerance in nanoparticle volume fraction and coating thickness, facilitating low-cost and scalable spray-coated high-efficiency solar selective absorbers for high-temperature CSP systems.

14 SOLAR ENERGY↗

Characterization and Understanding of Thermal Transport in Stationary and Moving Particle Beds for Concentrating Solar Power

Concentrating solar power (CSP) coupled with thermal energy storage (TES) is being considered as an appealing solution to deliver stable, dispatchable, and inexpensive electricity generation from renewable solar energy. The heat from the HTF is stored in a TES system that is significantly less expensive and more scalable than electrochemical storage, enabling electricity generation when the sunlight is unavailable. The general concentrating solar thermal technologies are being pushed to higher temperature for higher efficiency and lower cost in a diverse range application in electricity generation (in CSP), industrial heating, and thermochemical fuel productions. Inert and abundant solid particles are becoming increasingly more important for these emerging applications. Heat transfer in both stationary and moving particle beds have been studied for many decades, revealing a great deal of insights on the mechanisms. Yet, there are still several unresolved problems from both fundamental understanding and technological applications points of view. In this Chapter, we will attempt to provide an up-to-date picture of thermal transport in stationary and moving particle beds. In both cases, we will review historical and contemporary developments in the theoretical, computational, and experimental aspects of heat transfer and related behaviors in particle beds. Here, we will discuss both the advancements and limitations of the existing studies and point to future developments towards deeper fundamental understandings and better engineering applications.

14 SOLAR ENERGY↗

Techno-Economic Analysis and Market Potential of Geological Thermal Energy Storage (GeoTES) Charged With Solar Thermal and Heat Pumps

In this project, we developed a techno-economic analysis (TEA) model that can be used to evaluate the viability of a proposed Geological Thermal Energy Storage (GeoTES) design. This MATLAB-based model integrates distinct subsystem models for the reservoir, wells, power cycle, and solar field to capture their distinct characteristics. It applies this approach in simulating GeoTES storage and dispatch operations for durations ranging from hourly to seasonal. Using cases studies based on GeoTES designs provided by industry partners - Premier Resource Management (PRM) and EarthBridge Energy - we validated the TEA model estimations of system performance and costs (such as thermal and electrical power/energy inflow and outflow, capital costs, and levelized costs of energy and storage) for both concentrating solar thermal (CST) and Carnot Battery (CB) pairings with GeoTES (CST-GeoTES and CB-GeoTES). For the CST-GeoTES case, the model was validated against the proposed system designed by PRM. It showed good agreement with PRM's estimations when well and pump costs derived from PRM's estimations were used. When GETEM-based costs were used, there was a slight overprediction due to GETEM's project/site agnostic assumption of these costs. From a sensitivity analysis perspective, the levelized cost of electricity (LCOE) of the CST-GeoTES case was most sensitive to well flow rate and the charging temperature. An optimal design scenario resulted in an LCOE of 0.11 $\$$/kWhe. CST-GeoTES can also provide a source of heat to meet seasonal demands. With 12-hour and 24-hour levelized cost of heat (LCOH) of 0.018 $\$$/kWhth and 0.022 $\$$/kWhth, respectively, CST-GeoTES could be competitive in the California market with an average industrial price of natural gas in California between 0.041-0.047 $\$$/kWhth. The levelized cost of storage (LCOS) for CST-GeoTES depends on the energy storage duration. Although the LCOS is relatively higher for shorter durations (e.g., ~0.50 $\$$/kWhe for 1 hour of storage), it is an order of magnitude lower (0.06 $\$$/kWhe) for longer storage durations and competitive with lithium-ion batteries (beyond 12 hours of storage) and molten-salt thermal energy storage (beyond 32 hours). Energy. Three options were explored and applied to the EarthBridge case study: (1) A Carnot Battery design using R125 working fluid with both hot and cold storage; (2) A Carnot Battery design using R125 working fluid with only hot storage; (3) A Carnot Battery using a commercially available heat pump with carbon dioxide (CO2) working fluid and hot storage only. The CB-GeoTES with cold storage only had a slight (round-trip) efficiency advantage over the system without (43.4% vs. 42.8%). This is because the cold storage is limited by the freezing point of water, so the cold storage is not much colder than the environment. The system using commercially available technologies was the least efficient - partly because different cycles were used in the heat pump (CO2) and heat engine (binary cycle) which leads to some inefficiencies. Using the commercially available design, the levelized cost of energy (LCOS) from the model (0.10 $\$$/kWhe) was higher than that estimated by EarthBridge (0.068 $\$$/kWhe). This is because of the low round-trip (38.7%) efficiency of the commercially available design. Sensitivity analysis reveals that the model is most sensitive to electricity price. Including electricity price in the TEA for CB-GeoTES leads to an increase in LCOS from the base value to 0.25 $\$$/kWhe. To determine storage sites suitable for GeoTES, we gathered and analyzed geological, petrophysical, and geophysical data of oil and gas reservoir and aquifers in California and Texas. We down-selected possible sites based on cut-off values for site characteristics (e.g., reservoir temperature, formation thickness, permeability, porosity, depth, and brine salinity) and preliminary costs. Using this approach, the Carrizo-Wilcox, Yegua-Jackson, and Dockum brackish aquifers in Texas were identified as having the highest suitability. Similarly, in the central California region, the White Wolf, Belridge South Tulare, and Belridge South Reef Ridge were the most suitable. Going further, we assessed the storage potential in the selected sites. To do this we developed distributions of reservoir characteristic data and applied a Monte Carlo-based analysis to account for intrinsic uncertainty in the acquired data. The analysis revealed that the Carrizo-Wilcox aquifer had the highest storage potential with a mean capacity of 554 TWhth (i.e., 63 TWhe). The estimated capacity serves as an upper limit of storage potential given that not all fields in the basin will be developed. We participated in multiple outreach activities including conference presentations, panel session discussions, and the facilitation of a GeoTES workshop at the NREL Golden campus.

15 GEOTHERMAL ENERGY↗

Optimal Sizing and Dispatch of Solar Power with Storage

Designers of utility-scale solar plants with storage, seeking to maximize some aspect of plant performance, face multiple challenges. In many geographic locations, there is significant penetration of photovoltaic generation, which depresses energy prices during the hours of solar availability. An energy storage system affords the opportunity to dispatch during higher-priced time periods, but complicates plant design and dispatch decisions. Solar resource variability compounds these challenges, because determining optimal system sizes requires simultaneously considering how the plant will be operated under the imposed market and weather conditions. We develop an approach to analyze the economic performance of hybrid and single-technology solar power plants, which incorporates optimal dispatch, and considers the expected electricity market and weather conditions. We utilize the System Advisor Model software package to simulate the operation of multiple renewable generation and energy storage technologies, in conjunction with hourly-fidelity generation decisions determined by a revenue-maximizing, mixed-integer linear program. We show that, under our assumed market and weather conditions, the lifetime benefit-to-cost ratio can be improved by 6 to 19 percent, relative to a baseline design without optimizing, and that a concentrating solar power with thermal energy storage design produces significantly more energy per year, but is less profitable under our cost assumptions.

black-box optimization↗

Numerical study of advanced solar receiver tubes based on a coupled thermo-mechanical analysis for concentrated solar power tower plant

The search for more sustainable energy to match the growing energy demand begins with finding more dispatchable resources such as solar energy. As one of the promising solar technologies, concentrated solar power (CSP) has a full capacity to store thermal energy for extended operation. Nevertheless, some key components in CSP systems usually face extreme environment, such as uneven solar flux, cyclic thermal expansion, structural degradation on the solar absorber tubes in a Concentrated Solar Power Tower (CSPT) Plant. In this study, we applied Multiphysics simulation to explore the benefits of introducing optimized fins for heat transfer enhancement and uniform temperature distribution, the goal is to improve the thermal efficiency of such advanced solar absorber tubes. The results of this study can supply design guidance for the manufacturing process of absorber tubes, and eventually can benefit the solar energy community for the next generation of molten salt based CSP system.

14 SOLAR ENERGY↗

Integrated Thermal Energy Storage and Brayton Cycle Equipment Demonstration (Integrated TESTBED) Project Design Basis

The Integrated Thermal Energy Storage and Brayton cycle Equipment Demonstration (Integrated TESTBED) project seeks to retire commercial-scale risks associated with the design, integration,and operation of a supercritical carbon dioxide (sCO2) power cycle and concentrating solar power (CSP) thermal energy storage (TES) system. This requires an understanding of commercial-scale collector system transient impacts on the TES system, the dynamics of heat exchange from theTES to the power cycle, and the control and operation of the power cycle to accommodate various dispatch strategies. In order to retire these risks, Heliogen has proposed to construct a 5 MWe CSP demonstration facility based on directly heated particle and sCO2 technology. The receivers, primary heat exchanger, and power cycle will be deployed at a full commercial scale based on Heliogen’s modular plant architecture to ensure actual system integration risks are validated during design, construction, and operation. This work summarizes the design basis for the Integrated TESTBED project demonstration facility including a design target for capacity factor to support test operations, hours of storage, particle silo arrangement, centrifugal article receivers, a diffusion bonded particle-sCO2 heat exchanger, and a 5 MWe (net) integrally geared sCO2 recompression Brayton cycle.

14 SOLAR ENERGY↗

A review of Geological Thermal Energy Storage for seasonal, grid-scale dispatching

Energy storage is essential for the decarbonization of the U.S. energy grid, especially with the increasing deployment of variable renewable energy sources like solar and wind. Geological thermal energy storage (GeoTES) has emerged as a promising long duration, grid scale solution, providing stability and security through flexible operations and valuable grid services. GeoTES utilizes subsurface reservoirs to store thermal energy for power generation and direct-use heating and cooling. This approach significantly enhances the use of low-temperature reservoirs, which would otherwise be unsuitable for geothermal power plants. It also aligns well with depleted oil and gas reservoirs, concentrating solar power, non-flexible renewables (photovoltaic and wind), and geothermal-related power cycles. Given the favorable marginal costs of GeoTES as storage duration increases, it becomes particularly competitive for seasonal, grid-scale dispatch, where few technologies are viable. This paper provides a comprehensive review of GeoTES systems and the research underpinning itsr development. This analysis begins by defining and categorizing the unique characteristics of thermal energy storage techniques, setting GeoTES apart from other technologies. The various components, configurations, subsurface characteristics, and modeling efforts that guide GeoTES development are then explored. Finally, challenges in GeoTES research, development, and deployment are discussed, along with mitigation strategies and lessons from related technologies. Beyond their economic benefits, GeoTES systems support grid resilience and decarbonize industrial processes. Their scalability, broad distribution, seasonal storage potential, and flexible dispatch capacity make GeoTES a valuable tool for expanding renewable energy deployment and addressing climate change.

15 - GEOTHERMAL ENERGY↗

Assessing the Optical Performance Impact of Tracking Error in an Operational Concentrated Solar Power Plant Using Monte Carlo Ray-Tracing Simulation

Concentrating Solar Power (CSP) provides firm and dispatchable electricity due to its thermal storage and hybridization capabilities, which supports the decarbonization of our energy supply. Of the various CSP technologies, parabolic trough collectors are the most mature, with over 500 MW operating worldwide. The optical performance of parabolic trough systems is sensitive to tracking error, which is defined as the angular offset of a collector away from the sun position in the transversal plane. Tracking error commonly occurs due to non-continuous adjustment of the trough angle to point toward the sun, but other factors such as gravity, heating, and wind loading can also contribute to tracking error. Researchers have explored the impact of tracking error on optical performance both numerically and experimentally, but existing studies do not include measurements from operational utility-scale power plants. Tilt angle measurements of parabolic troughs at operational utility-scale power plants illustrate spatial variations in optical performance and include various sources of tracking error such as gravity, heating, and wind loading. To fully characterize wind driven loads on parabolic troughs, we are conducting a long-term field measurement campaign at the Nevada Solar One CSP plant located in Boulder City, NV, which has a nominal capacity of 72 MW and 0.5 hours of full-load storage. We record load measurements on four outer trough rows, collecting support structure bending moments, drive torque moments, dynamic accelerations of the spaceframe, mirror displacement, and tilt angles. Using the tilt measurements acquired at 20 Hz frequency, we calculate the deviation between the nominal sun position and the tracker angle. Using a Monte-Carlo ray-tracing simulation software, we assess the impact of the tracker angle deviation on optical performance throughout the diurnal cycle at various spatial locations within the CSP plant. In our view, this first-of-a-kind study will provide important guidance for future trough designs that reduce the impact of various sources of tracking error on performance.

concentrating solar power↗