Search NASASearch

SEARCH · Search NASA

Results for “Timing resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Fronts and frontogenesis as revealed by high time resolution data

Upper air sounding are used to examine a cold front of average intensity. Vertical cross sections of potential temperature and wind, and horizontal analyses were compared and adjusted for consistency. These analyses were then used to study the evolution of the front, found to consist of a complex system of fronts occurring at all levels of the troposphere. Low level fronts were strongest at the surface and rapidly weakened with height. Fronts in the midddle troposphere were much more intense. The warm air ahead of the fronts was nearly barotropic, while the cold air behind was baroclinic through deep layers. A deep mixed layer was observed to grow in this cold air.

Frank, A. E.

A picosecond resolution Time Digitizer for laser ranging

The Time Digitizer capable of covering a range of 0.34 sec in 9.76 psec increments is described. The time interval between a pair of start-stop pulses is digitized coarsely in 20 nsec periods by a very accurate 50 MHz reference clock. The residual fractions of a clock period at the start and the stop end of the measured interval are stretched in two interpolators and digitized in 9.76 psec increments. An equivalent digitizing frequency of 102.4 GHz is thus achieved. The digitizer is built in a minicrate and communicates via a standard crate controller. It is intended for use in the laser ranging between ground stations and the Laser Geodetic Satellite (LAGEOS). It is shown that the distribution in any two adjacent 9.76 psec channels of a small number of identical test time intervals is essentially binomial. The performance of the digitizer and test results are given.

Turko, B.

High time resolution studies of upstream ions

The influence of phi, the angle between the interplanetary magnetic field and the earth-sun vector on ions and electrons in the earth's bow shock, was investigated in terms of ISEE 2 data. A small phi was associated with intermediate energy upstream ions and reduced populations of low energy, about 1.6 keV, ion fluxes. The magnitude of phi was closely related to particular, constant energy levels, e.g., a phi of 40 deg and an energy of 30 keV and a phi of 75 deg and an energy of 6 keV. Ion fluxes are high in the angles form 60-80 deg and feature energies of 55-280 keV. The acceleration process up to the high energy levels in the 1-3 min interval from upstream to downstream occurs more rapidly than could be accounted for by a first-order Fermi process.

Anderson, K. A.

Comparison of solar hard X-ray and UV line and continuum bursts with high time resolution

A comparison of data sets from the UV Spectrometer and Polarimeter and Hard X-ray Burst Spectrometer instruments on SMM has established the close relationship of the impulsive phase hard X-ray and UV continuum and OV line emissions, lending support to the notion that they have a similar origin low in the solar atmosphere. These results severely constrain models that attempt to explain impulsive phase hard X-rays and UV emission; alternative processes of impulsive-phase UV continuum production should accordingly be considered. Attention is given to an electron beam 'hole boring' mechanism and a photoionization radiation transport mechanism.

Orwig, L. E.

Neutron techniques

Three experimental methods are described which hold the most promise for improved energy resolution, time resolution and sensitivity in the detection of solar neutrons on satellites and/or long duration balloon flights: the neutron calorimeter, the solar neutron track chamber, and the solar neutron decay proton detector. The characteristics of the three methods as to energy range, energy resolution, time resolution, detection efficiency, and physical properties are delineated. Earlier techniques to measure the intensity of high-energy cosmic-ray neutrons at the top of the atmosphere and to search for solar neutrons are described. The past three decades of detector development has now reached the point where it is possible to make comprehensive and detailed measurements of solar neutrons on future space missions.

Frye, Glenn M., Jr.

High-time resolution measurements of upstream magnetic field and plasma conditions during flux transfer events at the Earth's dayside magnetopause

We present preliminary results of a study of upstream magnetic field and plasma conditions measured by IRM during flux transfer events observed at the Earth's magnetopause by CCE. This study was designed to determine the importance of various upstream factors in the formation of bipolar magnetic field signatures called flux transfer events (FTEs). Six FTE encounters were examined. In three cases, the two satellites were on similar magnetic field lines. Preliminary investigation showed that fluctuations occurred in the Bz component of the interplanetary magnetic field (IMF) resulting in a southward field preceding the FTE in all three of these cases. In two of these cases, the changes were characterized by a distinct rotation from a strong southward to a strong northward field. There were also accompanying changes in the dynamic and thermal pressure in the solar wind immediately before the FTE was encountered. Examination of the 3D plasma distributions showed that these pulses were due to the addition of energetic upstreaming foreshock particles. There were no consistent changes in either Bz or the plasma pressure at IRM for the three events when the satellites were not connected by the IMF.

Jacob, Jamey D.

Faint-object spectrograph for Space Telescope

The paper presents the Faint Object Spectrograph (FOS) for the Space Telescope to provide a digitized spectra of faint astronomical objects over the 115 to 700 nm wavelength range at resolving powers of 1000 and 100. A variety of concave gratings and prisms is employed to form nearly stigmatic spectra on one of the two Digicon photon counting detectors which are optimized for two different but overlapping ranges. The scientific goals associated with quasars, active galaxies, and objects within our solar system are discussed, and the FOS optical design features, including detectors, electronics, signal processing, power supplies, and data handling are examined. The FOS structural system, mechanism, and controls are described, along with the predicted performance capabilities in the spectral and spectropolarimetry modes. Finally, system performance parameters, including spatial resolution, time resolution, noise, and efficiency are discussed.

Harms, r. J.

Microphysics of the auroral acceleration region of other regions of the magnetosphere

Electric field and plasma measurements pertinent to the microphysics of the auroral acceleration region are reviewed. Observations in other regions of the magnetosphere, which appear to involve similar physical processes, are summarized in order to emphasize the requirement on Cluster instrumentation for wide dynamic range, high time resolution, time domain field, and particle measurements. It is suggested that the microphysics of current driven instabilities in the auroral acceleration region is duplicated in the high latitude boundary of the plasma sheet and that the macroscale structure of the tail is determined by this microphysics.

Mozer, F. S.

Observations of x ray pulsars from the Kvant module

The Roentgen international x ray observatory on the Kvant module of the Mir space station has been successfully operating since the beginning of June 1987. Many x ray sources were observed and among them were several x ray pulsars. Four telescopes mounted on board the Kvant module cover a wide energy range with good timing resolution. Timing analysis of the Kvant module data suffers from the presence of only short continuous intervals of source observations, separated by 90 min gaps (90 min is the orbital period of the Mir space station around the Earth). The presence of 90 min gaps leads to the appearance of beat frequencies v=v sub 0 + or - n/90 min (n = 1, 2, 3). Special analysis was applied to avoid this difficulty. Results are presented of the pulsation period measurements of the x ray pulsars Her X-1, Cen X-3, SMC X-1, Vela X-1, A0535 + 26 by the instruments on board the Kvant module in 1987 to 1989. The values of the periods are reduced to the solar system barycenter and to the binary system barycenter (excluding A0535 + 26).

Gilfanov, M.

Flare stars and solar bursts - High resolution in time and frequency

Coronal loops on the sun and nearby stars are studied using observations at 20-cm wavelength with high resolution in time and frequency. Observations of the dwarf M star AD Leonis with high time resolution led to the discovery of a quasi-periodic train of circularly polarized spikes with a mean periodicity of 32 + or - 5 ms and a total duration of 150 ms. Observations at closely spaced wavelengths using the VLA revealed a narrow-band structure in solar bursts and in the slowly varying radiation of the dwarf M star YZ Canis Minoris. This narrow-band emission may be attributed to electron-cyclotron maser radiation. Maser action at the second or first harmonic of the gyrofrequency implies magnetic field strengths of 250 and 500 G, respectively. Hence, observations with high resolution in time and frequency suggest coherent processs in the coronas of the sun and dwarf M stars. It is noted that the scientific potential suggested by the present data can be realized by the development of a solar-stellar synthesis radiotelescope. This instrument would be dedicated to solar and stellar observations with high angular, temporal, and frequency resolution.

Lang, K. R.

Single photon detection and timing in the Lunar Laser Ranging Experiment.

The goals of the Lunar Laser Ranging Experiment lead to the need for the measurement of a 2.5 sec time interval to an accuracy of a nanosecond or better. The systems analysis which included practical retroreflector arrays, available laser systems, and large telescopes led to the necessity of single photon detection. Operation under all background illumination conditions required auxiliary range gates and extremely narrow spectral and spatial filters in addition to the effective gate provided by the time resolution. Nanosecond timing precision at relatively high detection efficiency was obtained using the RCA C31000F photomultiplier and Ortec 270 constant fraction of pulse-height timing discriminator. The timing accuracy over the 2.5 sec interval was obtained using a digital interval with analog vernier ends. Both precision and accuracy are currently checked internally using a triggerable, nanosecond light pulser. Future measurements using sub-nanosecond laser pulses will be limited by the time resolution of single photon detectors.

Poultney, S. K.

The characteristics of impulsive solar EUV bursts

This paper examines a number of high-time-resolution intensity-time profiles of EUV impulsive bursts as observed by the EUV spectroheliometer carried aboard the Skylab Apollo Telescope Mount. These bursts are found to be synchronous (to within the instrumental time resolution of 5.5 s) in all wavelengths observed, corresponding to emissions from temperatures ranging from upper-chromospheric to coronal. The distribution with temperature of a suitably defined emission-measure parameter is also examined as a function of time throughout the bursts, and a marked similarity in the shape of this distribution, both between different events and throughout the time history of any particular event, is noted. The significance of these observations for physical processes associated with EUV bursts is briefly discussed.

Emslie, A. G.

Associated Particle Imaging of Neutron Inelastic Scatter: 3-D Reconstruction, Capabilities, and Challenges

Associated particle imaging (API) offers unique advantages for 3-D imaging of neutron inelastic scatter, including single-view tomographic imaging and data acquisition when access is limited to only one side of the interrogated object. However, widespread adoption of neutron inelastic scatter imaging has been impeded by several inherent challenges, most prominently spatial resolution, self-attenuation, and statistical noise. Here, in this work, the capabilities and challenges of neutron inelastic scatter imaging are investigated. Instead of focusing on a single imaging application, we identify imaging principles that hold for various neutron inelastic scatter imaging techniques. The primary challenges for 3-D imaging are characterized. The inherent spatial resolution in the time-of-flight (TOF) dimension is derived based on the known system timing resolution and scan geometry. Three reconstruction algorithms are described and demonstrated, including the introduction of modern iterative reconstruction incorporating a physics-based system model. Simulation is leveraged to demonstrate imaging capability with varying coincidence count levels and system timing resolution. An example of measured data with both back-scatter and forward-scatter detector positioning is presented. System design characteristics and their effects on image quality are identified. The imaging framework presented in this article has the potential to facilitate growth of 3-D neutron inelastic scatter API by identifying applications that are a good match for the technique and by targeting system development resources toward the requirements of a specific imaging task.

Associated particle imaging (API)