Search NASA⌕ Search

SEARCH · Search NASA

Results for “Titanium nitride”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Rolling contact fatigue of surface modified 440C using a 'Ge-Polymet' type disc rod test rig

Through hardened 440 C martensitic stainless steel test specimens were surface modified and tested for changes in rolling contact fatigue using a disc on rod test rig. The surface modifications consisted of nitrogen, boron, titanium, chromium, tantalum, carbon, or molybdenum ion implantation at various ion fluences and energies. Tests were also performed on specimens reactively sputtered with titanium nitride.

Thom, Robert L.↗

Measurement of Charge Transfer Rate Coefficient Between Ground-State N(2+) Ion and He at Electron-Volt Energies

The charge transfer rate coefficient for the reaction N(2+)(2p(sup 2)P(sup 0)) + He yields products is measured by recording the time dependence of the N(2+) ions stored in an ion trap. A cylindrical radio-frequency ion trap was used to store N(2+) ions produced by laser ablation of a solid titanium nitride target. The decay of the ion signals was analyzed by single exponential least-squares fits to the data. The measured rate coefficient is 8.67(0.76) x 10(exp -11)sq cm/s. The N(2+) ions were at a mean energy of 2.7 eV while He gas was at room temperature, corresponding to an equivalent temperature of 3.9 x 10(exp 3) K. The measured value is in good agreement with a recent calculation.

Fang, Z.↗

Charge Transfer Between Ground-State N(2+) and H2, N2, and CO at Electron-Volt Energies

The charge-transfer rate coefficients for reactions of N(2+)(2 S(sup 2)2p(sup 2)P(sup 0)) with H2, N2, and CO are measured using ion storage. A cylindrical rf ion trap was used to store N(2+) ions produced by laser ablation of a solid titanium nitride target. The rate coefficients were derived from the decay rate of the ion signal. The rate coefficients for the above three reactions are 3.38(0.35) x 10(exp -11)sq sm/s at T(sub equiv.)=2.9 x 10(exp 3) K, 2.10(0.18) x 10(exp -9)sq sm/s at T(sub equiv.) = 1.3 x 10(exp 4) K, and 3.37(0.29) x 10(exp -9)sq cm/s at T(sub equiv.) = 1.3 x 10(exp 4) K, respectively. No theoretical or other experimental values are available at this energy range.

Fang, Z.↗

Airborne Submillimeter Spectroscopy

This is the final technical report for NASA-Ames grant NAG2-1068 to Caltech, entitled "Airborne Submillimeter Spectroscopy", which extended over the period May 1, 1996 through January 31, 1998. The grant was funded by the NASA airborne astronomy program, during a period of time after the Kuiper Airborne Observatory was no longer operational. Instead. this funding program was intended to help develop instrument concepts and technology for the upcoming SOFIA (Stratospheric Observatory for Infrared Astronomy) project. SOFIA, which is funded by NASA and is now being carried out by a consortium lead by USRA (Universities Space Research Association), will be a 747 aircraft carrying a 2.5 meter diameter telescope. The purpose of our grant was to fund the ongoing development of sensitive heterodyne receivers for the submillimeter band (500-1200 GHz), using sensitive superconducting (SIS) detectors. In 1997 July we submitted a proposal to USRA to construct a heterodyne instrument for SOFIA. Our proposal was successful [1], and we are now continuing our airborne astronomy effort with funding from USRA. A secondary purpose of the NAG2-1068 grant was to continue the anaIN'sis of astronomical data collected with an earlier instrument which was flown on the NASA Kuiper Airborne Observatory (KAO). The KAO instrument and the astronomical studies which were carried out with it were supported primarily under another grant, NAG2-744, which extended over October 1, 1991 through Januarv 31, 1997. For a complete description of the astronomical data and its anailysis, we refer the reader to the final technical report for NAG2-744, which was submitted to NASA on December 1. 1997. Here we report on the SIS detector development effort for SOFIA carried out under NAG2-1068. The main result of this effort has been the demonstration of SIS mixers using a new superconducting material niobium titanium nitride (NbTiN), which promises to deliver dramatic improvements in sensitivity in the 700-1200 GHz frequency range.

Zmuidzinas, J.↗

Electric Field Double Probe Measurements on Satellites with Very Low Perigees

Measurements of DC and AC electric Fields at low altitudes (less than 150 km) in the Earth's ionosphere address a wide array of important scientific questions including Joule Heating, the closure of field aligned currents, and the deviation of E x B electron velocities from ion velocity vectors influenced by collisions. Double probes represent a well-proven technique for gathering high quality DC and AC electric field measurements for which the design of the boom system is of critical importance for the success of the experiment. In general, ionospheric DC electric field instruments that achieve accuracies of 0.1 mV/m or better, place sensors at large distances from the spacecraft body in order to extend well beyond the spacecraft wake and sheath and to achieve the large signal-to-noise ratios for DC and long wavelength measurements. Additional sets of sensors inboard of the primary, outermost sensors provide useful additional information, both for diagnostics of the plasma contact potentials, which particularly enhance the DC electric field measurements on non-spinning spacecraft, and for wavelength and phase velocity measurements that use the spaced receiver or "Interferometer" technique. Accurate attitude knowledge enables V x B contributions to be subtracted from the measured potentials, and permits the measured components to be rotated into meaningful geophysical reference frames. This presentation discusses the expected performance of electric field double probe experiments and their boom mechanisms on both spinning and non-spinning satellite platforms with very low perigees. Careful selection of probe surface materials, such as titanium nitride, for the low perigee environment, as well as thermal considerations are also discussed.

Pfaff, R. F., Jr.↗

A Low Noise NbTiN-Based 850 GHz SIS Receiver for the Caltech Submillimeter Observatory

We have developed a niobium titanium nitride (NbTiN) based superconductor- insulator-superconductor (SIS) receiver to cover the 350 micron atmospheric window. This frequency band lies entirely above the energy gap of niobium (700 GHz), a commonly used SIS superconductor. The instrument uses an open structure twin-slot SIS mixer that consists of two Nb/AlN/NbTiN tunnel junctions, NbTiN thin-film microstrip tuning elements, and a NbTiN ground plane. The optical configuration is very similar to the 850 GHz waveguide receiver that was installed at the Caltech Submillimeter Observatory (CSO) in 1997. To minimize front-end loss, we employed reflecting optics and a cooled beamsplitter at 4 K. The instrument has an uncorrected receiver noise temperature of 205K DSB at 800 GHz and 410K DSB at 900 GHz. The degradation in receiver sensitivity with frequency is primarily due to an increase in the mixer conversion loss, which is attributed to the mismatch between the SIS junction and the twin-slot antenna impedance. The overall system performance has been confirmed through its use at the telescope to detect a wealth of new spectroscopic lines.

Kooi, J. W.↗

A Low-Noise NbTiN Hot Electron Bolometer Mixer

Hot electron bolometer (HEB) mixer elements, based on niobium titanium nitride (NbTiN) thin film technology, have been fabricated on crystalline quartz substrates over a 20 nm thick AlN buffer layer. The film was patterned by optical lithography, yielding bolometer elements that measure about 1 micrometer long and between 2 and 12 micrometers wide. These mixer chips were mounted in a fixed-tuned waveguide mixer block, and tested in the 600 and 800 GHz frequency range. The 3-dB output bandwidth of these mixers was determined to be about 2.5 GHz and we measured a receiver noise temperature of 270 K at 630 GHz using an intermediate frequency of 1.5 GHz. The receiver has excellent amplitude stability and the noise temperature measurements are highly repeatable. An 800 GHz receiver incorporating one of these mixer chips has recently been installed at the Sub-Millimeter Telescope in Arizona for field test and for astronomical observations.

Tong, C. Edward↗

Symmetric Absorber-Coupled Far-Infrared Microwave Kinetic Inductance Detector

The present invention relates to a symmetric absorber-coupled far-infrared microwave kinetic inductance detector including: a membrane having an absorber disposed thereon in a symmetric cross bar pattern; and a microstrip including a plurality of conductor microstrip lines disposed along all edges of the membrane, and separated from a ground plane by the membrane. The conducting microstrip lines are made from niobium, and the pattern is made from a superconducting material with a transition temperature below niobium, including one of aluminum, titanium nitride, or molybdenum nitride. The pattern is disposed on both a top and a bottom of the membrane, and creates a parallel-plate coupled transmission line on the membrane that acts as a half-wavelength resonator at readout frequencies. The parallel-plate coupled transmission line and the conductor microstrip lines form a stepped impedance resonator. The pattern provides identical power absorption for both horizontal and vertical polarization signals.

U-yen, Kongpop↗

Parallel plate capacitor TiN KID array development for the Balloon Experiment for Galactic Infrared Science

The Balloon Experiment for Galactic Infrared Science (BEGINS) will map dust spectral energy distributions (SEDs) between 25 and 250 microns near high-mass star regions, characterizing the radiation fields and dust properties of a variety of stellar environments. To accomplish these goals, BEGINS will be outfitted with roughly 1,800 titanium nitride (TiN), superconducting kinetic inductance detectors (KIDs). A parallel plate capacitor KID design is used to achieve high pixel density arrays. A cryogenic, silicon-based, metal-mesh linear variable filter will define detector band passes across the KID array. Optical coupling to the filters and telescope will be accomplished using silicon microlenses. Here we present laboratory characterization of prototype BEGINS detector arrays, describe future array development plans, and describe the testbed used to characterize the arrays.

Nicholas F. Cothard↗

Parallel-Plate Capacitor TiN KIDs for Infrared Astronomy

The Balloon Experiment for Galactic INfrared Science (BEGINS) is a concept for a sub-orbital observatory that will characterize dust in the vicinity of high-mass stars. It requires detectors with NEPs from 2x10 -16 W Hz -1/2 to 6x10 -17 W Hz -1/2 from 25-250 microns, respectively. The mission’s sensitivity requirements will be met by utilizing arrays of 1,840 lens-coupled, lumped-element kinetic inductance detectors (KIDs) operating at 300 mK. Each KID will consist of a titanium nitride (TiN) parallel strip absorbing inductive section and parallel plate capacitor deposited on a Silicon (Si) substrate. The parallel plate capacitor geometry allows for reduction of the pixel spacing. We present the optical performance of a prototype BEGINS KID array at 25 microns when coupled to Fresnel zone plate lenses. We present sensitivity, optical efficiency and quasiparticle lifetime measurements taken in a cryogenic test bed with a cryogenic blackbody.

Joanna Perido↗

Wear and Neutron Shielding Resilience of Titanium-Hexagonal Boron Nitride Coatings Against Extreme Lunar Radiation and Thermal Cycles

Ti6Al4V and Al6061 are aerospace alloys used in lunar structural components and rovers owing to their high specific strength. However, they deteriorate rapidly when subjected to demanding conditions of the lunar environment, such as extreme thermal cycles, solar particle radiation, and abrasive regolith. Cryo-milled powders were employed to deposit hBN-reinforced protective titanium coatings through plasma spray (atmospheric APS and vacuum-VPS) with 2 and 10 vol% of hBN on Ti6Al4V and Al6061 substrates. These coatings were evaluated for durability under extreme lunar-like conditions, including thermal cycling, electron radiation, and synergistic (electron radiation-thermal cycle) exposure. The coatings exhibited radiation-induced hardening, resulting in a substantial increase in their microhardness ~20–40% compared to virgin condition. Bright-field transmission electron microscopy (TEM) analysis reveals the presence of high dislocation densities, black dot defects, and dislocation clusters, providing evidence of the severe impact of synergistic environmental stresses. Ball-on-disk tribological tests were conducted in the presence of JSC-1 A lunar regolith simulant to evaluate the wear performance of coatings. Compared to conventional Ti6Al4V substrate, 50%, 90%, and 70% reductions in wear volume were observed in the Ti/2 vol% hBN coatings in thermal-only, radiation-only, and synergistic environments. Neutron shielding tests indicate that the synergistic coatings offer higher neutron shielding performance by up to 28% compared to virgin coatings, attributed to improved neutron capture by 10B isotopes. Upon a comprehensive assessment and ranking of multiple coatings under varying conditions, the VPS Ti/2 vol% hBN coating emerges as the top choice for protection against extreme radiation and thermal cycles for future lunar explorations.

Boron nitride↗

Vapor pressure and evaporation rate of certain heat-resistant compounds in a vacuum at high temperatures

The vapor pressure and evaporation rate of borides of titanium, zirconium, and chrome; and of strontium and carbides of titanium, zirconium, and chrome, molybdenum silicide; and nitrides of titanium, niobium, and tantalum in a vacuum were studied. It is concluded that all subject compounds evaporate by molecular structures except AlB sub 12' which dissociates, losing the aluminum.

Bolgar, A. S.↗

Several new catalysts for reduction of oxygen in fuel cells

Test results prove nickel carbide or nitride, nickel-cobalt carbide, titanium carbide or nitride, and intermetallic compounds of the transition or noble metals to be efficient electrocatalysts for oxygen reduction in alkaline electrolytes in low temperature fuel cells.

Cattabriga, R. A.↗

Analytical and experimental investigation of rubbing interaction in labyrinth seals for a liquid hydrogen fuel pump

Cracking of the titanium knife edges on the labyrinth seals of the liquid hydrogen fuel pump in the Space Shuttle main engine is considered. Finite element analysis of the thermal response of the knife edge in sliding contact with the wear ring surface shows that interfacial temperatures can be quite high and they are significantly influenced by the thermal conductivity of the surfaces in rubbing contact. Thermal shock experiments on a test specimen similar to the knife edge geometry demonstrate that cracking of the titanium alloy is possible in a situation involving repeated thermal cycles over a wide temperature range, as might be realized during a rub in the liquid hydrogen fuel pump. High-speed rub interaction tests were conducted using a representative knife edge and seal geometry over a broad range of interaction rates and alternate materials were experimentally evaluated. Plasma-sprayed aluminum-graphite was found to be significantly better than presently used aluminum alloy seals from the standpoint of rub performance. Ion nitriding the titanium alloy knife-edges also improved rub performance compared to the untreated baseline.

Dolan, F. X.↗

Use of a nitrogen-argon plasma to improve adherence of sputtered titanium carbide coatings on steel

Friction and wear experiments on 440-C steel surfaces that had been RF-sputtered with titanium carbide when a small percentage of nitrogen was added to the plasma were conducted. X-ray photoelectron spectroscopy and X-ray diffraction were used to analyze the resultant coatings. Results indicate that a small partial pressure of nitrogen (about 0.5%) markedly improves the adherence, friction, and wear properties when compared with coatings applied on sputter-etched oxidized surfaces or in the presence of a small oxygen partial pressure. The improvements are related to the formation of an interface containing a mixture of the nitrides of titanium and iron, which are harder than their corresponding oxides.

Brainard, W. A.↗

Effect of nitrogen-containing plasma on adherence, friction, and wear of radiofrequency-sputtered titanium carbide coatings

Friction and wear experiments on 440C steel surfaces that were rf sputtered with titanium carbide when a small percentage of nitrogen was added to the plasma were conducted. Both X-ray photoelectron spectroscopy and X-ray diffraction were used to analyze the resultant coatings. Results indicate that the small partial pressure of nitrogen (approximately 0.5 percent) markedly improves the adherence, friction, and wear properties when compared with coatings applied to sputter-etched surfaces, oxidized surfaces, or in the presence of a small oxygen partial pressure. The improvements are related to the formation of an interface containing a mixture of the nitrides of titanium and iron, which are harder than their corresponding oxides.

Brainard, W. A.↗