Effect of aerosols on the estimation of total ozone in an atmospheric column from the measurements of its ultraviolet radiance
The problem of estimating the total ozone amount of an atmospheric column in the presence of stratospheric and tropospheric aerosols is studied by means of simulated spectral measurements for the five-wavelength Nimbus 4 BUV configuration and the six-wavelength Nimbus G TOMS configuration, and by analyzing such measurements with appropriate total ozone estimation procedures. The simulated spectral measurements were generated for forty different atmospheric models arrived at by varying the total ozone content and various aerosol parameters. A total of ten different values of the solar zenith angle and eight different values of the Lambert reflectivity of the underlying surface were used. It was found that the values of total ozone in an atmospheric column estimated by the five-wavelength procedure can be in error by about + or -2% as a result of particulate contamination encountered in the terrestrial atmosphere under average conditions. Errors due to tropospheric particulate contamination can be reduced significantly by taking appropriate advantage of the additional spectral measurement offered by the Nimbus G TOMS instrument.