Nanoscale Free-Electron Lasing (Final Technical Report)

Optical control of electron dynamics and energy structure can be leveraged for tailoring classical and quantum light sources. Previous work was primarily limited to Transmission Electron Microscopes (TEMs). Our work under this program sought to enable full time and energy control of electrons in SEMs for exploring the physics of attosecond electron dynamics and light generation at the nanoscale. The motivation behind this work was to understand these fundamental processes important to free-electron lasing at the nanoscale using sub-relativistic electrons.

42 ENGINEERING↗

NSUF RTE completion report for 23-4780: Microstructural Defect Induced Thermal Conductivity Reduction in Uranium Nitride and Thorium Nitride

Uranium nitride (UN) is known to have a higher thermal conductivity than traditional oxide fuels, which could lead to a more efficient energy transport and lower local temperature during its lifetime. But the thermal transport performance of UN in extreme environments has not been systematic studied. This study investigated the irradiation induced microstructural defects in UN and the impacts on thermal conductivity. The samples were produced by spark plasma sintering at University of Texas-San Antonio (UTSA), Los Alamos National Laboratory (LANL), and Idaho National Laboratory (INL). Thermal conductivity of UN before and after 2MeV proton irradiation were measured by using laser metrology at INL in a temperature range of 77-295K. Thermal conductivity measurements in this wide, cryogenic temperature range is critical to understand the phonon scattering mechanisms between the thermal energy carrier, phonons, and different types of irradiation-induced defects. In order to ensure the measurements were conducted in the same grains and minimize the impact of the local heterogeneities, the measurement locations were highlighted by fiducial marks using the focused ion beam (FIB) with grain orientation identified using the electron backscatter diffraction (EBSD) at the Center of Advanced Energy Studies (CAES). Irradiation experiment was conducted at the Ion Beam Laboratory at Texas A&M University (TAMU). A total of 6 samples were irradiated with different irradiation doses and temperatures. After irradiation, the microstructure was characterized by using Transmission Electron Microscope (TEM) at CAES (also in the FIB marks).

36 - MATERIALS SCIENCE↗

Towards Construction of a Novel Nanometer-Resolution MeV-STEM for Imaging Thick Frozen Biological Samples

Driven by life-science applications, a mega-electron-volt Scanning Transmission Electron Microscope (MeV-STEM) has been proposed here to image thick frozen biological samples as a conventional Transmission Electron Microscope (TEM) may not be suitable to image samples thicker than 300–500 nm and various volume electron microscopy (EM) techniques either suffering from low resolution, or low speed. The high penetration of inelastic scattering signals of MeV electrons could make the MeV-STEM an appropriate microscope for biological samples as thick as 10 μm or more with a nanoscale resolution, considering the effect of electron energy, beam broadening, and low-dose limit on resolution. The best resolution is inversely related to the sample thickness and changes from 6 nm to 24 nm when the sample thickness increases from 1 μm to 10 μm. To achieve such a resolution in STEM, the imaging electrons must be focused on the specimen with a nm size and an mrad semi-convergence angle. This requires an electron beam emittance of a few picometers, which is ~1000 times smaller than the presently achieved nm emittance, in conjunction with less than 10 -4 energy spread and 1 nA current. We numerically simulated two different approaches that are potentially applicable to build a compact MeV-STEM instrument: (1) DC (Direct Current) gun, aperture, superconducting radio-frequency (SRF) cavities, and STEM column; (2) SRF gun, aperture, SRF cavities, and STEM column. Beam dynamic simulations show promising results, which meet the needs of an MeV-STEM, a few-picometer emittance, less than 10 -4 energy spread, and 0.1–1 nA current from both options. Also, we designed a compact STEM column based on permanent quadrupole quintuplet, not only to demagnify the beam size from 1 μm at the source point to 2 nm at the specimen but also to provide the freedom of changing the magnifications at the specimen and a scanning system to raster the electron beam across the sample with a step size of 2 nm and the repetition rate of 1 MHz. This makes it possible to build a compact MeV-STEM and use it to study thick, large-volume samples in cell biology.

36 MATERIALS SCIENCE↗

Preparing Lamellae from Vitreous Biological Samples using a Dual-Beam Scanning Electron Microscope for Cryo-Electron Tomography

Presented here is a protocol for preparing cryo-lamellae from plunge-frozen grids of Plasmodium falciparum-infected human erythrocytes, which could easily be adapted for other biological samples. The basic principles for preparing samples, milling, and viewing lamellae are common to all instruments and the protocol can be followed as a general guide to on-grid cryo-lamella preparation for cryo-electron microscopy (cryoEM) and cryo-electron tomography (cryoET). Electron microscopy grids supporting the cells are plunge-frozen into liquid nitrogen-cooled liquid ethane using a manual or automated plunge freezer, then screened on a light microscope equipped with a cryo-stage. Frozen grids are transferred into a cryo-scanning electron microscope equipped with a focused ion beam (cryoFIB-SEM). Grids are routinely sputter coated prior to milling, which aids dispersal of charge build-up during milling. Alternatively, an e-beam rotary coater can be used to apply a layer of carbon-platinum to the grids, the exact thickness of which can be more precisely controlled. Once inside the cryoFIB-SEM an additional coating of an organoplatinum compound is applied to the surface of the grid via a gas injection system (GIS). This layer protects the front edge of the lamella as it is milled, the integrity of which is critical for achieving uniformly thin lamellae. Regions of interest are identified via SEM and milling is carried out in a step-wise fashion, reducing the current of the ion beam as the lamella reaches electron transparency, in order to avoid excessive heat generation. A grid with multiple lamellae is then transferred to a transmission electron microscope (TEM) under cryogenic conditions for tilt-series acquisition. A robust and contamination-free workflow for lamella preparation is an essential step for downstream techniques, including cellular cryoEM, cryoET, and sub-tomogram averaging. Development of these techniques, especially for lift-out and milling of high-pressure frozen samples, is of high-priority in the field.

59 BASIC BIOLOGICAL SCIENCES↗

In situ self-ion (Fe + ) irradiation of ODS-FeCrAl alloy fuel cladding materials with different Cr contents: The early stages of Cr-rich α’ phase precipitation

Oxide-dispersion-strengthened FeCrAl (ODS-FeCrAl) alloys are candidate accident-tolerant fuel cladding materials for light water reactors because they demonstrate satisfactory resistance to materials degradation effects such as high-temperature oxidation, radiation-induced swelling, and creep. Their perspective deployment to market is challenged, however, by their inherent susceptibility to irradiation embrittlement caused by the precipitation of the brittle Cr-rich α’ phase at relatively low temperatures (≤475 °C). This work used in situ self-ion irradiation (150 keV Fe + ) in a transmission electron microscope to elucidate the early stages of Cr-rich α’ phase precipitation in three candidate ODS-FeCrAl alloy fuel cladding materials with different Cr contents (10, 12, and 20 wt.%) and microstructures. The early stages of the process resulting in the precipitation of the Cr-rich α’ phase in these three ODS-FeCrAl alloys under Fe + irradiation were investigated at room temperature and 300 °C up to total fluences of 1.7 × 10 15 ions·cm -2 (2 dpa) and 3.4 × 10 15 ions·cm -2 (4 dpa), using three damage dose rates (5 × 10 –5 , 3.3 × 10 –4 , and 2 × 10 –3 dpa·s -1 ). Post-irradiation examination via scanning transmission electron microscopy, energy-dispersive X-ray spectroscopy and electron energy loss spectroscopy suggested that the precipitation of the Cr-rich α’ phase might be promoted by the phase separation of the alloy matrix into Cr-rich and Fe-rich regions. Interestingly, oxygen impurities segregated preferentially in the Cr-rich regions, possibly promoting the radiation-assisted formation of the Cr-rich α’ phase. α’ phase precipitation was more pronounced at room temperature when compared to 300 °C, and it was clearly promoted by the progressive increase in the Cr content of the ODS-FeCrAl alloy.

36 MATERIALS SCIENCE↗

Operando X-ray Absorption Spectroscopy Study of SnO 2 Nanoparticles for Electrochemical Reduction of CO 2 to Formate

Tin–based electrocatalysts exhibit a remarkable ability to catalyze CO 2 to formate selectively. Understanding the size-property relationships and exploring the evolutions of active size still lack complete understanding. Herein, we prepared SnO 2 nanoparticles (NPs) with controllable size supported on commercial carbon spheres (SnO 2 /C–n, n=1,2,3) by a simple low-temperature annealing method. The transmission electron microscopy(TEM)/scanning transmission electron microscope (STEM) images and fitting results of the small angle X-ray scattering (SAXS) profile confirm the increased size of SnO 2 NPs as the increase of SnO 2 loading. The catalytic performance of SnO 2 has proved the size-dependent effect during CO 2 reduction reaction process. The as-prepared SnO 2 /C–1 displayed the maximum Faradic efficiency of formate (FE HCOO– ) of 82.7% at –1.0 V vs. RHE. In contrast, SnO 2 /C–2 and SnO 2 /C–3 with larger particle sizes achieved lower maximum FE HCOO– and larger overpotential. Moreover, we employed operando XAS to study the evolution of the oxidation state and local coordination environment of SnO 2 under working conditions. In addition to the observed the shifts of rising edge of Sn K-edge X-ray absorption near edge structure (XANES) spectra to lower energy side as the applied voltage decreases, the decreased coordination number of Sn in the Sn-O scattering path and the presence of Sn mental contribution in extended X-ray absorption fine structure (EXAFS) spectra verify the reduction of SnO 2 to SnO x and metallic Sn.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid assessment of structural and compositional changes during early stages of zirconium alloy oxidation

A multimodal chemical imaging approach has been developed and applied to detail the dynamic, atomic-scale changes associated with oxidation of a zirconium alloy (Zircaloy-4). Scanning transmission electron microscopy, a gas-phase reactor chamber attached to an atom probe tomography instrument, and synchrotron-based X-ray absorption near-edge spectroscopy were employed to reveal morphology, composition, crystal, and electronic structure changes that occur during initial stages of oxidation at 300 °C. Oxidation was carried out in 10 mbar O 2 gas for short exposure times of 1 and 5 min. A multilayered oxide film with a cubic ZrO adjacent to the oxide/metal interface, a nanoscopic transition region with a graded composition of ZrO 2-x (where 0 < x < 1), and tetragonal ZrO 2 in the outermost oxide were formed. Partitioning of the major alloying element (tin) to the oxide/metal interface and heterogeneously within the oxide accompanied the development of the layered oxide. Our work provides a rapid, high-throughput approach for detailed characterisation of initial stages of zirconium alloy oxidation at an accelerated time scale, with implications for several other alloy systems.

36 MATERIALS SCIENCE↗

A new mechanism for void-cascade interaction from nondestructive depth-resolved atomic-scale measurements of ion irradiation–induced defects in Fe

The nondestructive investigation of single vacancies and vacancy clusters in ion-irradiated samples requires a depth-resolved probe with atomic sensitivity to defects. The recent development of short-pulsed positron beams provides such a probe. Here, we combine depth-resolved Doppler broadening and positron annihilation lifetime spectroscopies to identify vacancy clusters in ion-irradiated Fe and measure their density as a function of depth. Despite large concentrations of dislocations and voids in the pristine samples, positron annihilation measurements uncovered the structure of vacancy clusters and the change in their size and density with irradiation dose. When combined with transmission electron microscopy measurements, the study demonstrates an association between the increase in the density of small vacancy clusters with irradiation and a remarkable reduction in the size of large voids. This, previously unknown, mechanism for the interaction of cascade damage with voids in ion-irradiated materials is a consequence of the high porosity of the initial microstructure.

36 MATERIALS SCIENCE↗

Instrumentation and Samples (CRADA Final Report)

Instruments which are categorized as shared user instruments at the National Laboratory of the Rockies (NLR) will be utilized for ongoing technical work. Samples will be provided by University of Colorado Boulder (CU) and thus no need for materials at NLR is anticipated.

(Ga1- xZnx)(N1-xOx)↗

Randomly Layered Superstructure of In 2 O 3 Truncated Nano-Octahedra and Its High-Pressure Behavior

This study outlines the synthesis and characterization of a unique superlattice composed of vertex-truncated indium oxide (In 2 O 3 ) nano-octahedra, along with an exploration of its response to high-pressure conditions. Here, using a bright-field transmission electron microscope (BF-TEM), we determined an average circumradius of 15.2 nm for these octahedral building blocks. The resilience and response of the superlattice to pressure variations, peaking at 18.01 GPa, were examined by employing synchrotron-based Wide-Angle X-ray Scattering (WAXS) and Small-Angle X-ray Scattering (SAXS) techniques. The WAXS data revealed no phase transitions, reinforcing the stability of the 2D superlattice comprised of random layers in alignment with a 2D p31m symmetry. Notably, the SAXS data unveiled a pressure-induced, irreversible octahedron translation and ligand interaction occurring within the random layer. Through our examination of these pressure-sensitive behaviors, we identified a distinctive translation model inherent to octahedra and observed modulation in the superlattice cell parameter induced by pressure. This research signifies a noteworthy progression in deciphering the intricate behaviors of 2D superlattices under high-pressure conditions.

36 MATERIALS SCIENCE↗

Assessing the quality of large-area monolayer graphene grown on liquid copper for size-selective ionic/molecular membrane separations

Monolayer graphene growth on liquid copper (Cu) has attracted attention due to advantages of a flat/smooth catalytic growth surface, high synthesis temperature (>1080 °C) as well as the possibility of forming graphene domains that are mobile on the liquid Cu with potential to minimize grain boundary defects and self-assemble into a continuous monolayer film. However, the quality of monolayer graphene grown on liquid copper and its suitability for size-selective ionic/molecular membrane separations has not been evaluated/studied. Here, we probe the quality of monolayer graphene grown on liquid Cu (via a metallurgical process, HSMG ® ) using Scanning Electron Microscope (SEM), High-resolution transmission electron microscope (HR-TEM), Raman spectroscopy and report on a facile approach to assess intrinsic sub-nanometer to nanometer-scale defects over centimeter-scale areas. We demonstrate high transfer yields of monolayer graphene (>93% coverage) from the growth substrate to polyimide track etched membrane (PITEM, pore diameter ~200 nm) supports to form centimeter-scale atomically thin membranes. Next, we use pressure-driven transport of ethanol to probe defects > 60 nm and diffusion-driven transport of analytes (KCl ~0.66 nm, L-Tryptophan ~0.7–0.9 nm, Vitamin B12 ~1–1.5 nm and Lysozyme ~3.8–4 nm) to probe nanoscale and sub-nanometer scale defects. Diffusive transport confirms the presence of intrinsic sub-nanometer to nanometer scale defects in monolayer graphene grown on liquid Cu are no less than that in high-quality graphene synthesized via chemical vapor deposition (CVD) on solid Cu. Our work not only benchmarks quality of graphene grown on liquid copper for membrane applications but also provides fundamental insights into the origin of intrinsic defects in large-area graphene synthesized via bottom-up processes for membrane applications.

36 MATERIALS SCIENCE↗

Sample Preparation and Experimental Design for In Situ Multi-Beam Transmission Electron Microscopy Irradiation Experiments

We discuss the need to understand materials exposed to overlapping extreme environments such as high temperature, radiation, or mechanical stress. When these stressors are combined there may be synergistic effects that enable unique microstructural evolution mechanisms to activate. Understanding of these mechanisms is necessary for the input and refinement of predictive models and critical for engineering of next generation materials. The basic physics and underlying mechanisms require advanced tools to be investigated. The in situ ion irradiation transmission electron microscope (I 3 TEM) is designed to explore these principles. To quantitatively probe the complex dynamic interactions in materials, careful preparation of samples and consideration of experimental design is required. Particular handling or preparation of samples can easily introduce damage or features that obfuscate the measurements. There is no one correct way to prepare a sample; however, many mistakes can be made. The most common errors and things to consider are highlighted within. The I 3 TEM has many adjustable variables and a large potential experimental space, therefore it is best to design experiments with a specific scientific question or questions in mind. Experiments have been performed on large number of sample geometries, material classes, and with many irradiation conditions. The following are a subset of examples that demonstrate unique in situ capabilities utilizing the I 3 TEM. Au nanoparticles prepared by drop casting have been used to investigate the effects of single ion strikes. Au thin films have been used in studies on the effects of multibeam irradiation on microstructure evolution. Zr films have been exposed to irradiation and mechanical tension to examine creep. Ag nanopillars were subjected to simultaneous high temperature, mechanical compression, and ion irradiation to study irradiation induced creep as well. These results impact fields including: structural materials, nuclear energy, energy storage, catalysis, and microelectronics in space environments.

47 OTHER INSTRUMENTATION↗

Experimental and computational investigations on the SO 2 poisoning of (La 0.8 Sr 0.2 ) 0.95 MnO 3 cathode materials

To study the formation of detrimental phases under the sulfur gas impurity to the long-term degradation in the LSM cathode material, the classic cathode material, (La 0.8 Sr 0.2 ) 0.95 MnO 3 (LSM), was prepared, sintered, and annealed at 800, 900, and 1000°C in the sulfur-containing atmospheres, respectively. Through X-Ray Diffraction (XRD), Scanning Electron Microscope (SEM), and Transmission electron microscopy (TEM) techniques, as well as the CALPHAD (Computer Coupling of Phase Diagrams and Thermochemistry) methodology, the secondary phases, especially the detrimental ones, under different conditions were predicted and experimentally verified correspondingly. Furthermore, sulfur poisoning results indicate that the accelerated tests might have degradation mechanisms different from actual operation conditions. More importantly, comprehensive comparisons among various impurity-containing conditions were also made to recommend better operation parameters.

36 MATERIALS SCIENCE↗

Mitigating Damage to Hybrid Perovskites Using Pulsed-Beam TEM

Using a pulsed-beam transmission electron microscope, we discover a reduction in damage to methylammonium lead iodide (MAPbI3) as compared to conventional beams delivered at the same dose rates. For rates as low as 0.001 e·Å –2 ·s –1 , we find up to a 17% reduction in damage at a total dose of 10 e·Å –2 . We systematically study the effects of number of electrons in each pulse and the duration between pulse arrival. Damage increases for both, though the number of electrons per pulse has a larger effect. A crossover is identified, where a pulsed beam causes more damage than a conventional one. Although qualitatively similar to previous findings, the degree to which damage is reduced in MAPbI3 is less than that observed for other materials (e.g., C36H74), supporting the hypothesis that the effects are material- and damage-mechanism-dependent. Despite this, the observation here of damage reduction for relatively large electron packets (up to 200 electrons per pulse) suggests that MAPbI3 is in fact less susceptible to irradiation than C36H74, which may be related to reported self-healing effects. This work provides insights into damage processes and durability in hybrid perovskites and also illustrates the viability of using pulsed-beam TEM to explore the associated molecular-level routes to degradation, analogous to laser-accelerated energetic pulsed electron beams and the study of damage to biomolecules, cells, and tissues in radiobiology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Towards Autonomous Experiments by Connecting High Performance Microscopy with High Performance Computing

The digitization of controls, data, and analysis in microscopy is bringing the idea of autonomous microscopes closer to reality than ever before. Automated transmission electron microscopy (TEM) is already fairly routine for some experiments the only require simple repetitive tasks such as imaging biological macromolecules for single particle cryoEM [1], tilt series for electron tomography [2], and movies for crystallography [3]. The vast majority of TEM experiments are conducted completely by human operators who choose the regions of interest, optimize experimental parameters, and make decisions about data quality visually during an experiment. The field is still a long way from having completely autonomous TEMs that can adapt to sample difficulties and tune experimental parameters based on data quality and desired experimental outcomes. Part of the issue is the lack of capability for feeding information learned from on-line, live data analysis back into the on-going experiment [4]. Furthermore, this presentation will discuss current capabilities for large scale data reduction and analysis using high performance computing (i.e. supercomputing) and progress towards developing a true feed-back loop that places data analysis and theory in the experimental loop.

97 MATHEMATICS AND COMPUTING↗

Effects of Neutron Irradiation on the Micro/Nano Scale Structure and Fission Product Distribution of TRISO Coated Particle Fuel Kernels from AGR Experiments

The Advanced Reactor Technologies (ART) Program at Idaho National Laboratory (INL) includes the Advanced Gas Reactor (AGR) fuel development and qualification program that consists of fuel fabrication, experiment irradiations, post-irradiation examination (PIE) and safety testing to assess tristructural isotropic (TRISO) fuel performance during normal irradiation and under potential accident conditions. Advanced microscopy work on selected AGR-1 and AGR-2 unirradiated and irradiated fuel specimens is performed as part of the PIE effort. PIE work on fuel from the first experiment irradiation, AGR-1, began at INL in April 2010, and AGR-2 PIE began at INL in July 2014. This work scope includes University of Florida (UF) performing advanced electron microscopy examination and analysis using facilities at the Center for Advanced Energy Studies (CAES), INL or UF’s electron microscopy facilities. Electron microscopic examination and analysis may include scanning transmission electron microscopy (STEM), transmission electron microscopy (TEM), selected area diffraction (SAD), electron energy loss spectroscopy (EELS), electron dispersive spectroscopy (EDS) and atom probe tomography (APT) on the fuel kernels of TRISO-coated fuel particles. The electron microscopy lamellae will be provided by INL and will be available at CAES or Irradiated Materials Characterization Laboratory (IMCL).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Facile Tensile Testing Platform for In Situ Transmission Electron Microscopy of Nanomaterials

In situ tensile testing using transmission electron microscopy (TEM) is a powerful technique to probe structure-property relationships of materials at the atomic scale. In this work, a facile tensile testing platform for in situ characterization of materials inside a transmission electron microscope is demonstrated. The platform consists of: 1) a commercially available, flexible, electron-transparent substrate (e.g., TEM grid) integrated with a conventional tensile testing holder, and 2) a finite element simulation providing quantification of specimen-applied strain. The flexible substrate (carbon support film of the TEM grid) mitigates strain concentrations usually found in free-standing films and enables in situ straining experiments to be performed on materials that cannot undergo localized thinning or focused ion beam lift-out. The finite element simulation enables direct correlation of holder displacement with sample strain, providing upper and lower bounds of expected strain across the substrate. The tensile testing platform is validated for three disparate material systems: sputtered gold-palladium, few-layer transferred tungsten disulfide, and electrodeposited lithium, by measuring lattice strain from experimentally recorded electron diffraction data. The results show good agreement between experiment and simulation, providing confidence in the ability to transfer strain from holder to sample and relate TEM crystal structural observations with material mechanical properties.

2D materials↗

Study of Helium Irradiation Effect on Al6061 Alloy Fabricated by Additive Friction Stir Deposition

Additive friction stir deposition (AFS-D) is considered a productive method of additive manufacturing (AM) due to its ability to produce dense mechanical parts at a faster deposition rate compared to other AM methods. Al6061 alloy finds extensive application in aerospace and nuclear engineering; nevertheless, exposure to radiation or high-energy particles over time tends to deteriorate their mechanical performance. However, the effect of radiation on the components manufactured using the AFS-D method is still unexamined. In this work, samples from the as-fabricated Al6061 alloy, by AFS-D, and the Al6061 feedstock rod were irradiated with He+ ions to 10 dpa at ambient temperature. The microstructural and mechanical changes induced by irradiation of He+ were examined using a scanning electron microscope (SEM), energy-dispersive X-ray spectroscopy (EDS), transmission electron microscopy (TEM), and nanoindentation. This study demonstrates that, at 10 dpa of irradiation damage, the feedstock Al6061 produced a bigger size of He bubbles than the AFS-D Al6061. Nanoindentation analysis revealed that both the feedstock Al6061 and AFS-D Al6061 samples have experienced radiation-induced hardening. These studies provide a valuable understanding of the microstructural and mechanical performance of AFS-D materials in radiation environments, offering essential data for the selection of materials and processing methods for potential application in aerospace and nuclear engineering.

36 MATERIALS SCIENCE↗