Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transonic wind tunnel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Some solutions to the problems and pitfalls of laser velocimetry in a large transonic wind tunnel

Attention is given to engineering design and development features of a two-component, coaxial backscatter laser velocimetry system which attempts to realize the long-recognized desirability of this technique's use for nonintrusive flow measurement. The design of the optics for the present 16-foot transonic wind tunnel device, and problems associated with the installation of the system in the hostile, test section plenum chamber environment are discussed.

Reubush, D. E.↗

Development and utilization of a laser velocimeter system for a large transonic wind tunnel

The need for measurements of the velocity flow field about spinner propeller nacelle configurations at Mach numbers to 0.8 was met by a specially developed laser velocimeter system. This system, which uses an argon ion laser and 4 beam 2 color optics, was required to operate in the hostile environment associated with the operation of a large transonic wind tunnel. To overcome the conditions present in locating the sensitive optics in close proximity to the wind tunnel, an isolation system was developed. The system protects the velocimeter from the high vibrations, elevated temperatures, destructive acoustic pressures and low atmospheric pressures attendant with the operation of the wind tunnel. The system was utilized to map the flow field in front of, behind and in between the rotating blades of an advanced swept blade propeller model at a Mach number of 0.8. The data collected by the system will be used to correlate and verify computer analyses of propeller nacelle flow fields and propeller performance.

Freedman, R. J.↗

Acoustic reflection contamination measurements in the 16-foot NASA Langley Transonic Wind Tunnel

The Propfan Test Assessment (PTA) contract, awarded recently to Lockheed by the NASA-Lewis Research Center, required a comprehesive series of near field acoustic measurements. These were to use transducers mounted on the surfaces on a one-ninth scale model of the Gulfstream G-II aircraft, modified to the PTA single propfan testbed configuration. The 16-foot Transonic Wind Tunnel at the NASA Langley Research Center was chosen as the facility to be used for these model acoustic tests. Since the tunnel was hard-walled, it is not clear to what extent the propfan noise signals, reaching the various transducers, might be contaminated by reflections from the walls. A Multidriver Acoustic Source was built, and using an impulse and time domain averaging technique, the reflection contaminations in the wind tunnel were measured at selected microphone locations. Results of the investigations of near field measurements exists, due to reflections from the hard walls of the wind tunnnel.

Burrin, R. H.↗

Fluid dynamic research at NASA-Ames Research Center related to transonic wind tunnel design and testing techniques

Fluid dynamic research with the objective of developing new and improved technology in both test facility concepts and test techniques is being reported. A summary of efforts and results thus far obtained in four areas is presented. The four area are: (1) the use of heavy gases to obtain high Reynolds numbers at transonic speeds: (2) high Reynolds number tests of the C-141A wing configuration; (3) performance and flow quality of the pilot injector driven wind tunnel; and (4) integration time required to extract accurate static and dynamic data from tests in transonic wind tunnels. Some of the principal conclusions relative to each of the four areas are: (1) Initial attempts to apply analytical corrections to test results using gases with gamma other than 1.4 to simulate conditions in air show promise but need significant improvement; (2) for the C-141A configuration, no Reynolds number less than the full scale flight value provides an accurate simulation of the full scale flow; (3) high ratios of tunnel mass flow rate to injection mass flow rate and high flow quality can be obtained in an injector driven transonic wind tunnel; and (4) integration times of 0.5 to 1.0 sec may be required for static force and pressure tests, respectively, at some transonic test conditions in order to obtain the required data accuracy.

Muhlstein, L., Jr.↗

Wind tunnel test of the 0.019 scale space shuttle integrated vehicle (model 14-OTS) in the CALSPAN 8-foot transonic wind tunnel (IA36), volume 2

A test is presented which was performed to determine the effect of cold jet gas plumes generated from main propulsion system and solid rocket motor nozzles on: (1) six-component force and moment data, (2) wing static pressures, (3) wing hinge moment, (4) elevon hinge moment, (5) rudder hinge moment, and (6) orbiter MPS nozzle pressure loads. The effects of rudder deflection, nozzle gimbal angle, and plume size were also obtained.

Hardin, R. B.↗

Revalidation of the NASA Ames 11-by 11-Foot Transonic Wind Tunnel with a Commercial Airplane Model

The 11-By 11-Foot Transonic leg of the Unitary Plan Wind Tunnel (UPWT) was modernized to improve tunnel performance, capability, productivity, and reliability. Wind tunnel tests to demonstrate the readiness of the tunnel for a return to production operations included an Integrated Systems Test (IST), calibration tests, and airplane validation tests. One of the two validation tests was a 0.037-scale Boeing 777 model that was previously tested in the 11-By 11-Foot tunnel in 1991. The objective of the validation tests was to compare pre-modernization and post-modernization results from the same airplane model in order to substantiate the operational readiness of the facility. Evaluation of within-test, test-to-test, and tunnel-to-tunnel data repeatability were made to study the effects of the tunnel modifications. Tunnel productivity was also evaluated to determine the readiness of the facility for production operations. The operation of the facility, including model installation, tunnel operations, and the performance of tunnel systems, was observed and facility deficiency findings generated. The data repeatability studies and tunnel-to-tunnel comparisons demonstrated outstanding data repeatability and a high overall level of data quality. Despite some operational and facility problems, the validation test was successful in demonstrating the readiness of the facility to perform production airplane wind tunnel%, tests.

Kmak, Frank J.↗

Computation of wall effects in ventilated transonic wind tunnels.

A method for computing interference effects due to ventilated wind-tunnel walls on lifting transonic airfoils is presented. Differences between the present method based on nonlinear transonic theory and the classical correction formulae from linear subsonic theory are discussed. Computed results are presented for an NACA 0012 in solid and perforated wall tunnels. The solid wall calculations are compared with data.

Murman, E. M.↗

Evaluation of flow quality in two NASA transonic wind tunnels

Tests have been conducted in the Langley Research Center 8-foot Transonic Pressure Tunnel and the Ames Research Center 12-foot pressure wind tunnel in order to measure characteristic disturbance levels and energy spectra in their respective settling chambers, test sections, and diffusers and to determine the sources of these disturbances. Results are presented and discussed along with some specific recommendations.

Owen, F. K.↗

A transonic wind tunnel wall interference prediction code

A small disturbance transonic wall interference prediction code has been developed that is capable of modeling solid, open, perforated, and slotted walls as well as slotted and solid walls with viscous effects. This code was developed by modifying the outer boundary conditions of an existing aerodynamic wing-body-pod-pylon-winglet analysis code. The boundary conditions are presented in the form of equations which simulate the flow at the wall, as well as finite difference approximations to the equations. Comparisons are presented at transonic flow conditions between computational results and experimental data for a wing alone in a solid wall wind tunnel and wing-body configurations in both slotted and solid wind tunnels.

Phillips, Pamela S.↗

A design method for entrance sections of transonic wind tunnels with rectangular cross sections

A mathematical technique developed to design entrance sections for transonic or high-speed subsonic wind tunnels with rectangular cross sections is discribed. The transition from a circular cross-section setting chamber to a rectangular test section is accomplished smoothly so as not to introduce secondary flows (vortices or boundary-layer separation) into a uniform test stream. The results of static-pressure measurements in the transition region and of static and total-pressure surveys in the test section of a pilot model for a new facility at the Ames Research Center are presented.

Lionel, L.↗

A survey of the three-dimensional high Reynolds number transonic wind tunnel

The facilities for aerodynamic testing of airplane models at transonic speeds and high Reynolds numbers are surveyed. The need for high Reynolds number testing is reviewed, using some experimental results. Some approaches to high Reynolds number testing such as the cryogenic wind tunnel, the induction driven wind tunnel, the Ludwieg tube, the Evans clean tunnel and the hydraulic driven wind tunnel are described. The level of development of high Reynolds number testing facilities in Japan is discussed.

Takashima, K.↗

Direct Validation of the Wall Interference Correction System of the Ames 11-Foot Transonic Wind Tunnel

Data from the test of a large semispan model was used to perform a direct validation of a wall interference correction system for a transonic slotted wall wind tunnel. At first, different sets of uncorrected aerodynamic coefficients were generated by physically changing the boundary condition of the test section walls. Then, wall interference corrections were computed and applied to all data points. Finally, an interpolation of the corrected aerodynamic coefficients was performed. This interpolation made sure that the corrected Mach number of a given run would be constant. Overall, the agreement between corresponding interpolated lift, drag, and pitching moment coefficient sets was very good. Buoyancy corrections were also investigated. These studies showed that the accuracy goal of one drag count may only be achieved if reliable estimates of the wall interference induced buoyancy correction are available during a test.

Ulbrich, Norbert↗

Experimental Investigations of the NASA Common Research Model in the NASA Langley National Transonic Facility and NASA Ames 11-Ft Transonic Wind Tunnel (Invited)

Experimental aerodynamic investigations of the NASA Common Research Model have been conducted in the NASA Langley National Transonic Facility and the NASA Ames 11-ft wind tunnel. Data have been obtained at chord Reynolds numbers of 5 million for five different configurations at both wind tunnels. Force and moment, surface pressure and surface flow visualization data were obtained in both facilities but only the force and moment data are presented herein. Nacelle/pylon, tail effects and tunnel to tunnel variations have been assessed. The data from both wind tunnels show that an addition of a nacelle/pylon gave an increase in drag, decrease in lift and a less nose down pitching moment around the design lift condition of 0.5 and that the tail effects also follow the expected trends. Also, all of the data shown fall within the 2-sigma limits for repeatability. The tunnel to tunnel differences are negligible for lift and pitching moment, while the drag shows a difference of less than ten counts for all of the configurations. These differences in drag may be due to the variation in the sting mounting systems at the two tunnels.

Rivers, S. M.↗

Check-Standard Testing Across Multiple Transonic Wind Tunnels with the Modern Design of Experiments

This paper reports the result of an analysis of wind tunnel data acquired in support of the Facility Analysis Verification & Operational Reliability (FAVOR) project. The analysis uses methods referred to collectively at Langley Research Center as the Modern Design of Experiments (MDOE). These methods quantify the total variance in a sample of wind tunnel data and partition it into explained and unexplained components. The unexplained component is further partitioned in random and systematic components. This analysis was performed on data acquired in similar wind tunnel tests executed in four different U.S. transonic facilities. The measurement environment of each facility was quantified and compared.

Deloach, Richard↗

Three-dimensional flow studies on a slotted transonic wind tunnel wall

Three-dimensional flow field measurements were made near a transonic slotted wall. Field velocity vectors and static pressure distributions have been obtained. The boundary layer displacement thickness was found to vary in the transverse plane with its maximum at the slot center line but decreased with increasing suction rate through the slot. The boundary layer characteristics were sensitive to the mass transfer through the slot. The projection on the flow field velocity vectors on the transverse plane reveals a vortex-like flow formation. The center of this secondary flow was located nearly at the edge of the wall shear layer and decreased in strength with applied suction. The secondary vortex motion may be attributed to the mean flow skewing, inhomogeneous transverse plane boundary layer and the wall turbulence anisotropy.

Wu, J. M.↗

Study on needs for a magnetic suspension system operating with a transonic wind tunnel

The U.S. aeronautical industry was surveyed to determine if current and future transonic testing requirements are sufficient to justify continued development work on magnetic suspension and balance systems (MSBS) by NASA. The effort involved preparation of a brief technical description of magnetic suspension and balance systems, design of a survey form asking specific questions about the role of the MSBS in satisfying future testing requirements, selecting nine major aeronautics companies to which the description and survey forms were sent, and visiting the companies and discussing the survey to obtain greater insight to their response to the survey. Evaluation and documentation of the survey responses and recommendations which evolved from the study are presented.

Martindale, W. R.↗

Development of a Large Field of View Shadowgraph System for a 16 Ft. Transonic Wind Tunnel

A large field of view shadowgraph flow visualization system for the Langley 16 ft. Transonic Tunnel (16 ft.TT) has been developed to provide fast, low cost, aerodynamic design concept evaluation capability to support the development of the next generation of commercial and military aircraft and space launch vehicles. Key features of the 16 ft. TT shadowgraph system are: (1) high resolution (1280 X 1024) digital snap shots and sequences; (2) video recording of shadowgraph at 30 frames per second; (3) pan, tilt, & zoom to find and observe flow features; (4) one microsecond flash for freeze frame images; (5) large field of view approximately 12 X 6 ft; and (6) a low maintenance, high signal/noise ratio, retro-reflective screen to allow shadowgraph imaging while test section lights are on.

Talley, Michael A.↗