68 records · Page 4

Multiscale dynamic experiments on fiber-reinforced composites with damage assessment using high-speed synchrotron X-ray phase-contrast imaging

We report fiber-reinforced composites (FRCs) have been widely used as protection materials to replace heavier metals. However, predictive capabilities for the impact-induced failure of FRCs have not been well-developed. In this work, we introduced an integrated technique to visualize the dynamic failure of FRCs, with the modified Kolsky bar loading and the high-speed synchrotron X-ray phase-contrast imaging (PCI). We summarize our experimental studies across the FRCs’ structural levels by using this integrated technique, including single-fiber tensile experiments, fiber/matrix debonding experiments, and single-edge notched bending experiments on composite laminates. It is revealed that the high-speed synchrotron X-ray PCI technique possesses sufficient spatial resolution to identify the failure behavior of a single fiber in the 10-μm scale level, as well as temporal resolution to identify the time sequence of internal dynamic damage evolution. The technique can penetrate through the opaque composite sample and provide real-time visualization of small-scale damaging mechanisms such as the embedded fiber’s sliding in the matrix and the fiber’s transverse debonding with the matrix. At an expanding scale, the technique can identify the crack initiation and track the cracking behavior inside a single ply or between different plies of a composite laminate. High-speed visualization inside the material by this integrated technique provides critical deformation and failure information to develop physical understanding of the damage inside composites under impact.

47 OTHER INSTRUMENTATION↗

Neutron Diffraction Residual Stress Characterization of Large-Scale Components by WA-DED

Two large scale 316L stainless steel cylindrical shells were fabricated by wire arc directed energy deposition (WA DED). Residual stresses were measured by neutron diffraction, and the microstructure and mechanical properties of the printed material were characterized. Longitudinal and transverse residual stresses were compressive at the inner diameter, near neutral at mid wall, and tensile at the outer diameter; radial (through thickness) residual stresses were relatively low in magnitude, and peak tensile residual stresses occurred at the outer diameter surface along the longitudinal direction. The printed 316L SS exhibited a heterogeneous microstructure with finely dispersed δ ferrite, and demonstrated high yield and tensile strengths with large elongation and ductile fracture at ambient temperature and at 250 °C. These results indicate that the outer diameter surface and near surface regions—where tensile residual stress is highest—are the most vulnerable to residual stress–sensitive failure modes, such as stress corrosion cracking and fatigue.

36 MATERIALS SCIENCE↗

C-Coupon Studies of SiC/SiC Composites: Acoustic Emission Monitoring - Part 1

Modal acoustic emission (AE) was used to monitor the acoustic activity during room temperature and elevated temperature c-coupon tests for a variety of SiC/SiC systems including composites containing Sylramic (trademark), ZMI (trademark), or Hi-Nicalon (trademark) fibers with melt-infiltrated or polymer-infiltrated SiC matrices. Modal AE proved excellent at monitoring matrix cracking in the curved portion of the C-coupon specimen with increasing load. This included the load at which the first AE event occurred and the location of AE events during the test that were, presumably, caused by the formation and growth of interlaminar cracks and, at higher loads, transverse cracks. Graphical techniques were employed to estimate the load for first AE. It was determined that for this test with these material systems, the first AE could be estimated within the load range bounded by the load at which initial deviation from linearity of the load-displacement curve occurs and the load where the 98% offset of the linear regression fit intercepted the load-displacement curve. The calculation of interlaminar tensile (ILT) stress from the load for first AE was determined for all the systems. Ultimate ILT strength usually corresponded to ILT stress determined from the ultimate load to failure of the C-coupon test, which was considerably higher than the first cracking stress.

Morscher, Gregory N.↗

Longitudinal splitting in unidirectional composites, analysis and experiments

An experimental study is conducted to determine the fracture behavior of center notched, unidirectional graphite/epoxy laminates when subjected to tensile loading. The actual behavior is compared to the behavior predicted by a mathematical model based on classical shear-lag assumptions. The model allows for damage to occur in the form of longitudinal matrix yielding and splitting with the matrix assumed to fail in pure shear. Results indicate that the model is capable of predicting split initiation stress levels accurately, but does not describe the subsequent split growth adequately. The model predicts rapid split growth following split initiation due to shear failure, while the actual behavior involves a slow split growth region prior to the rapid growth region. It is suggested that transverse matrix normal stresses are responsible for split initiation and the early, slow split growth. The model predicts the actual initiation stress levels reliably, and also appears to be able to predict the point at which the shear failure mode begins to dominate. The shear failure mode does eventually dominate, but at a slower rate than predicted. The nonuniform structure of the graphite/epoxy laminates is thought to be responsible for decreasing the split growth rate due to shear failure.

Goree, J. G.↗

Composite laminate free-edge reinforcement with U-shaped caps. I - Stress analysis. II - Theoretical-experimental correlation

The present generalized plane-strain FEM analysis for the prediction of interlaminar normal stress reduction when a U-shaped cap is bonded to the edge of a composite laminate gives attention to the highly variable transverse stresses near the free edge, cap length and thickness, and a gap under the cap due to the manufacturing process. The load-transfer mechanism between cap and laminate is found to be strain-compatibility, rather than shear lag. In the second part of this work, the three-dimensional composite material failure criteria are used in a progressive laminate failure analysis to predict failure loads of laminates with different edge-cap designs; symmetric 11-layer graphite-epoxy laminates with a one-layer cap of kevlar-epoxy are shown to carry 130-140 percent greater loading than uncapped laminates, under static tensile and tension-tension fatigue loading.

Howard, W. E.↗

Characterization and modeling of tensile behavior of ceramic woven fabric composites

This paper examines the tensile behavior of SiC/SiC fabric composites. In the characterization effort, the stress-strain relation and damage evolution are studied with a series of loading and unloading tensile test experiments. The stress-strain relation is linear in response to the initial loading and becomes nonlinear when loading exceeds the proportional limit. Transverse cracking has been observed to be a dominant damage mode governing the nonlinear deformation. The damage is initiated at the inter-tow pores where fiber yarns cross over each other. In the modeling work, the analysis is based upon a fiber bundle model, in which fiber undulation in the warp and fill directions and gaps among fiber yarns have been taken into account. Two limiting cases of fabric stacking arrangements are studied. Closed form solutions are obtained for the composite stiffness and Poisson's ratio. Transverse cracking in the composite is discussed by applying a constant failure strain criterion.

Kuo, Wen-Shyong↗

Mechanical properties of neat polymer matrix materials and their unidirectional carbon fiber-reinforced composites

The mechanical properties of two neat resin systems for use in carbon fiber epoxy composites were characterized. This included tensile and shear stiffness and strengths, coefficients of thermal and moisture expansion, and fracture toughness. Tests were conducted on specimens in the dry and moisture-saturated states, at temperatures of 23, 82 and 121 C. The neat resins tested were American Cyanamid 1806 and Union Carbide ERX-4901B(MPDA). Results were compared to previously tested neat resins. Four unidirectional carbon fiber reinforced composites were mechanically characterized. Axial and transverse tension and in-plane shear strengths and stiffness were measured, as well as transverse coefficients of thermal and moisture expansion. Tests were conducted on dry specimens only at 23 and 100 C. The materials tested were AS4/3502, AS6/5245-C, T300/BP907, and C6000/1806 unidirectional composites. Scanning electron microscopic examination of fracture surfaces was performed to permit the correlation of observed failure modes with the environmental test conditions.

Zimmerman, Richard S.↗

Effect of Prolonged Ultraviolet Radiation Exposure on the Blast Response of Fiber Reinforced Composite Plates

An experimental study with corresponding numerical simulations was conducted to evaluate the blast response of composite plates after prolonged exposure to ultraviolet radiation. Two composite materials were used in this study, namely carbon fiber/epoxy and glass fiber/vinyl ester. The composite materials consisted of four unidirectional fiber plies oriented in a [± 45°]s layup. The plates were placed in a QUV Accelerated Weathering Tester for 500 h of exposure on each face, totaling 1000 h of ultraviolet radiation exposure, equivalent to 2.5 MJ/m{sup 2} of energy. The QUV Accelerated Weathering Tester was equipped with eight UVA-340 lamps to provide real service life exposure conditions. Material characterization experiments were performed on virgin specimens, as well as specimens exposed to ultraviolet radiation for 1000 h to determine its effect on the mechanical properties of the composites. Blast experiments were conducted on the composite plates to investigate the dynamic response before and after exposure to ultraviolet radiation. The plates were clamped on all edges and subjected to an air blast using a shock tube apparatus. Three-dimensional digital image correlation was coupled with high-speed photography to obtain full-field displacements of the specimens during blast loading. Furthermore, three piezoelectric pressure transducers were mounted on the shock tube apparatus and utilized to measure the pressure history of the shock wave loading. The quasi-static material characterization showed that the tensile modulus E{sub 1} had minimal change after exposure to ultraviolet radiation for 1000 h. However, matrix-dominated properties such as the in-plane shear modulus G{sub 12} increased after exposure to ultraviolet light for both the carbon and glass fiber composites, which resulted in lower out-of-plane displacements during blast loading. For the carbon fiber plates, the forced vibration frequency induced by the transverse blast load was higher in plates exposed to ultraviolet radiation when compared to virgin specimens. However, for the glass fiber plates exposed to ultraviolet radiation, the forced vibration frequency decreased when compared to virgin specimens. Finally, the finite element simulations were in good agreement with the experimental results. The simulations revealed that the glass fiber plates exposed to ultraviolet radiation had higher failure strains at the boundary than virgin specimens, despite having higher stiffness. A parametric study in which higher loading was simulated also showed that the glass fiber plates experienced more damage after 1000 h of ultraviolet radiation exposure.

36 MATERIALS SCIENCE↗

Effects of Oxide Dispersion on Failure Modes in an Additively Manufactured Superalloy

Additive manufacturing opens new paths for introducing oxide particles into superalloys, to potentially provide oxide dispersion strengthening (ODS) at high temperatures. This provides opportunities to study how such dispersions can influence failure modes for a given superalloy, after nearly identical material processing paths. The objective of this study was to compare monotonic failure modes for additively manufactured superalloys with versus without an introduced oxide dispersion. The superalloy for each case was produced by laser powder bed fusion additive manufacturing. Specimens were subsequently given consistent thermal treatment paths and then tested in tensile and creep tests at varied temperatures. Failure modes were then compared. Additively manufactured NiCrAl without ODS had randomly oriented equiaxed grains while this alloy with 0.25 wt% Y 2 O 3 ODS additions had elongated [001] oriented grains in the build direction. Material made without ODS (“No-ODS”) was nearly completely single phase gamma, while ODS additions resulted in gamma, chromium carbide, and Y-Al-Cr oxide phases, with carbide and oxide phases contents estimated at no more than 13 and 1 vol%, respectively. Compared to No-ODS, material made with ODS had higher tensile strengths at room, 760 and 1093 °C. The elongation of ODS material was lower than No-ODS at room temperature, but higher at 760 °C. At 1093 °C ODS material had higher elongation than No-ODS when tested in the build direction, however elongation was lower for ODS material in the transverse direction at 1093 °C. Creep rupture strain, life, and area reduction at 760 and 1093 °C were all much higher for ODS material compared to No-ODS; 760 °C rupture life was nearly 100 times longer for ODS material. The presence of Y in the ODS material significantly improved oxidation resistance.

supperalloys↗

Fatigue Analysis of Notched Laminates: A Time-Efficient Macro-Mechanical Approach

A coupled transversely isotropic deformation and damage fatigue model is implemented within the finite element method and was utilized along with a static progressive damage model to predict the fatigue life, stiffness degradation as a function of number of cycles, and post-fatigue tension and compression response of notched, multidirectional laminates. Initially, the material parameters for the fatigue model were obtained utilizing micromechanics simulations and the provided [0], [90] and [plus or minus 45] experimental composite laminate S-N (stress-cycle) data. Within the fatigue damage model, the transverse and shear properties of the plies were degraded with an isotropic scalar damage variable. The damage in the longitudinal (fiber) ply direction was suppressed, and only the strength of the fiber was degraded as a function of fatigue cycles. A maximum strain criterion was used to capture the failure in each element, and once this criterion was satisfied, the longitudinal stiffness of the element was decreased by a factor of 10 (sup 4). The resulting, degraded properties were then used to calculate the new stress state. This procedure was repeated until final failure of the composite laminate was achieved or a specified number of cycles reached. For post-fatigue tension and compression behavior, four internal state variables were used to control the damage and failure. The predictive capability of the above-mentioned approach was assessed by performing blind predictions of the notched multidirectional IM7/977-3 composite laminates response under fatigue and post-fatigue tensile and compressive loading, followed by a recalibration phase. Although three different multidirectional laminates were analyzed in the course of this study, only detailed results (i.e., stiffness degradation and post-fatigue stress-train curves as well as damage evolution states for a single laminate ([30/60/90/minus 30/minus 60] (sub 2s)) are discussed in detail here.

Composite Fatigue analysis↗

High-Performance Acousto-Ultrasonic Scan System Being Developed

Acousto-ultrasonic (AU) interrogation is a single-sided nondestructive evaluation (NDE) technique employing separated sending and receiving transducers. It is used for assessing the microstructural condition and distributed damage state of the material between the transducers. AU is complementary to more traditional NDE methods, such as ultrasonic cscan, x-ray radiography, and thermographic inspection, which tend to be used primarily for discrete flaw detection. Throughout its history, AU has been used to inspect polymer matrix composites, metal matrix composites, ceramic matrix composites, and even monolithic metallic materials. The development of a high-performance automated AU scan system for characterizing within-sample microstructural and property homogeneity is currently in a prototype stage at NASA. This year, essential AU technology was reviewed. In addition, the basic hardware and software configuration for the scanner was developed, and preliminary results with the system were described. Mechanical and environmental loads applied to composite materials can cause distributed damage (as well as discrete defects) that plays a significant role in the degradation of physical properties. Such damage includes fiber/matrix debonding (interface failure), matrix microcracking, and fiber fracture and buckling. Investigations at the NASA Glenn Research Center have shown that traditional NDE scan inspection methods such as ultrasonic c-scan, x-ray imaging, and thermographic imaging tend to be more suited to discrete defect detection rather than the characterization of accumulated distributed microdamage in composites. Since AU is focused on assessing the distributed microdamage state of the material in between the sending and receiving transducers, it has proven to be quite suitable for assessing the relative composite material state. One major success story at Glenn with AU measurements has been the correlation between the ultrasonic decay rate obtained during AU inspection and the mechanical modulus (stiffness) seen during fatigue experiments with silicon carbide/silicon carbide (SiC/SiC) ceramic matrix composite samples. As shown in the figure, ultrasonic decay increased as the modulus decreased for the ceramic matrix composite tensile fatigue samples. The likely microstructural reason for the decrease in modulus (and increase in ultrasonic decay) is the matrix microcracking that commonly occurs during fatigue testing of these materials. Ultrasonic decay has shown the capability to track the pattern of transverse cracking and fiber breakage in these composites.

Roth, Don J.↗

High-Performance Acousto-Ultrasonic Scan System Being Developed

Acousto-ultrasonic (AU) interrogation is a single-sided nondestructive evaluation (NDE) technique employing separated sending and receiving transducers. It is used for assessing the microstructural condition and distributed damage state of the material between the transducers. AU is complementary to more traditional NDE methods, such as ultrasonic cscan, x-ray radiography, and thermographic inspection, which tend to be used primarily for discrete flaw detection. Throughout its history, AU has been used to inspect polymer matrix composites, metal matrix composites, ceramic matrix composites, and even monolithic metallic materials. The development of a high-performance automated AU scan system for characterizing within-sample microstructural and property homogeneity is currently in a prototype stage at NASA. This year, essential AU technology was reviewed. In addition, the basic hardware and software configuration for the scanner was developed, and preliminary results with the system were described. Mechanical and environmental loads applied to composite materials can cause distributed damage (as well as discrete defects) that plays a significant role in the degradation of physical properties. Such damage includes fiber/matrix debonding (interface failure), matrix microcracking, and fiber fracture and buckling. Investigations at the NASA Glenn Research Center have shown that traditional NDE scan inspection methods such as ultrasonic c-scan, x-ray imaging, and thermographic imaging tend to be more suited to discrete defect detection rather than the characterization of accumulated distributed micro-damage in composites. Since AU is focused on assessing the distributed micro-damage state of the material in between the sending and receiving transducers, it has proven to be quite suitable for assessing the relative composite material state. One major success story at Glenn with AU measurements has been the correlation between the ultrasonic decay rate obtained during AU inspection and the mechanical modulus (stiffness) seen during fatigue experiments with silicon carbide/silicon carbide (SiC/SiC) ceramic matrix composite samples. As shown in the figure, ultrasonic decay increased as the modulus decreased for the ceramic matrix composite tensile fatigue samples. The likely microstructural reason for the decrease in modulus (and increase in ultrasonic decay) is the matrix microcracking that commonly occurs during fatigue testing of these materials. Ultrasonic decay has shown the capability to track the pattern of transverse cracking and fiber breakage in these composites.

Roth, Don J.↗

Through-Thickness Tensile Properties of Triaxial Braided Composites

The through-thickness strength of triaxial braided composites was measured using thin specimens bonded to metallic tabs. Despite providing reasonable engineering estimates of the bulk properties, some test specimen limitations were noted: For strong epoxies, significant shear and tensile stresses occur and induce failure between the first layer and bond-line; the strains over much of the exterior are ~10% lower than interior strains, which are representative of the nominal state; and failure often occurred near or along the adhesive bond line. These interference were partially overcome by adding a large radius to the gage section. Based on the finite element analysis and experimental measurements, the nominal elastic modulus and Poisson's ratio are E(sub 33) = 10.7 GPa and v(sub 31) = 0.08 for the three triaxial braided composites tested. Strengths vary from 14 to 40 MPa depending on the resin. Relative to the in-plane properties, the through thickness modulus, fracture strength, failure strain, and Poisson's ratio are 1/5th, 1/30th, 1/6th, and 1/4th. Interlaminar failure occurred with varying degrees of fiber tear out along with little damage to axial tows, resulting is a smooth undulating fracture surface. Post cure temperature excursions to 177 deg C (350 deg F) had little effect on elastic constants but reduced the strength E862 based composites severely. The strength of PR520 and 5208 based composites increased.

composite↗

Exploration of Failure and Potential Damage Markers in Ti-6Al-4V

To improve prognostics for predicting component life, coupon tests were conducted on Ti-6Al-4V to investigate the development of damage. Various test types were employed (tension, creep, stress relaxation, and fatigue) under a wide range of temperatures and loading rates to engage various amounts of time-dependent and damage behavior. Both stiffness degradation and Poisson’s ratio were monitored to see if they were useful in indicating the initiation and accumulation of damage and subsequently the onset of failure. Stiffness exhibited large decreases with increasing strain when calculated using engineering stress and strain. However, minimal stiffness change was observed when using the true-stress and true- strain values. Detailed microscopy and image analysis were performed to document the actual physical damage that occurred within the various specimens. Two types of damage were observed: shallow surface cracks and internal pores. The severity of damage was greater in the region of localized necking and diminished further away from the neck. The area fraction of pores was higher in the necked region, yet even there it did not exceed more than a few percent and, in most cases, was significantly lower. It was observed that conditions that induced more time-dependent deformation (e.g., slower strain rate testing) resulted in a larger number of pores and larger pore sizes. The pores were always found to occur in the softer β-phase. The severity of observed damage was inconsistent with the large drop in engineering stiffness, but was more aligned with stiffness changes from the true-stress and -strain values. Poisson’s ratio was monitored on every test and showed promise as a damage indicator. It was found to be more sensitive than either the ultimate tensile strength or the inception of tertiary creep. However, calculation of Poisson’s ratio was found to be more involved than expected because of anisotropy and the presence of strain gradients along the specimen at large applied strains. First, the material had a moderate texture and resulted in anisotropy of the strains. Second, the evolution of Poisson’s ratio as a function of axial strain showed strange and unexpected behaviors, which necessitated more extensive analyses of its development. This led to an investigation on the use of small versus large strain approaches and the importance of making consistent measurements; that is, axial and transverse strain measurements over the same volume of material. Additionally, finite element analysis of a tensile sample indicated that non- uniform strain occurred in the sample prior to attaining the maximum strength. This, along with the location at which transverse strain was measured, had a significant influence on the resulting values of Poisson’s ratio. Based on this, lessons learned are offered for future testing.

Ti-6Al-4V↗