Search NASA⌕ Search

SEARCH · Search NASA

Results for “Trapped Ion Frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Radiative lifetimes of the 2s2p2(4P) metastable levels of N III

The radiative decay rates of N III 175 nm intersystem lines were measured in the laboratory by recording the time dependence of photon intensities emitted as the 2s2p2(4P) metastable term of N(2+) ions decay to the 2s22p(2P0) ground term. A cylindrical radio frequency ion trap was used to store the electron impact-produced N(2+) ions. The radiative decay signals were analyzed by multiexponential least-squares fits to the data. The measured radiative decay rates to the ground term are 1019(+/- 64)/s for 4P sub 1/2, 74.5(+/- 5.4)/s for 4P sub 3/2, and 308( +/- 22)/s for 4P sub 5/2. Comparisons of the measured values with theoretical values are presented.

Fang, Z.↗

Charge Transfer Between Ground-State Si(3+) and He at Electron-Volt Energies

The charge-transfer rate coefficient for the reaction Si(3+)(3s(sup 2)S) + He yields products is measured by means of a combined technique of laser ablation and ion storage. A cylindrical radio-frequency ion trap was used to store Si(3+) ions produced by laser ablation of solid silicon targets. The rate coefficient of the reaction was derived from the decay rate of the ion signal. The measured rate coefficient is 6.27(exp +0.68)(sub -0.52) x 10(exp -10)cu cm/s at T(sub equiv) = 3.9 x 10(exp 3)K. This value is about 30% higher than the Landau-Zener calculation of Butler and Dalgarno and is larger by about a factor of 3 than the recent full quantal calculation of Honvault et al.

Fang, Z.↗

A trapped mercury 199 ion frequency standard

Mercury 199 ions confined in an RF quadrupole trap and optically pumped by mercury 202 ion resonance light are investigated as the basis for a high performance frequency standard with commercial possibilities. Results achieved and estimates of the potential performance of such a standard are given.

Cutler, L. S.↗

Suppressing Loss of Ions in an Atomic Clock

An improvement has been made in the design of a compact, highly stable mercury- ion clock to suppress a loss of ions as they are transferred between the quadrupole and higher multipole ion traps. Such clocks are being developed for use aboard spacecraft for navigation and planetary radio science. The modification is also applicable to ion clocks operating on Earth: indeed, the success of the modification has been demonstrated in construction and operation of a terrestrial breadboard prototype of the compact, highly stable mercury-ion clock. Selected aspects of the breadboard prototype at different stages of development were described in previous NASA Tech Briefs articles. The following background information is reviewed from previous articles: In this clock as in some prior ion clocks, mercury ions are shuttled between two ion traps, one a 16- pole linear radio-frequency trap, while the other is a quadrupole radio-frequency trap. In the quadrupole trap, ions are tightly confined and optical state selection from a 202Hg lamp is carried out. In the 16-pole trap, the ions are more loosely confined and atomic transitions are interrogated by use of a microwave beam at approximately 40.507 GHz. The trapping of ions effectively eliminates the frequency pulling that would otherwise be caused by collisions between clock atoms and the wall of a gas cell. The shuttling of the ions between the two traps enables separation of the state-selection process from the clock microwave-resonance process, so that each of these processes can be optimized independently of the other. This is similar to the operation of an atomic beam clock, except that with ions the beam can be halted and reversed as ions are shuttled back and forth between the two traps. When the two traps are driven at the same radio frequency, the strength of confinement can be reduced near the junction between the two traps, depending upon the relative phase of the RF voltage used to operate each of the two traps, and can cause loss of ions during each transit between the traps and thereby cause loss of the 40.507-GHz ion-clock resonance signal. The essence of the modification is to drive the two traps at different frequencies typically between 1.5 and 2 MHz for the quadrupole trap and a frequency a few hundred kHz higher for the 16- pole trap. A frequency difference of a few hundred kHz ensures that the ion motion caused by the trapping electric fields is small relative to the diameter of the traps. Unlike in the case in which both traps are driven at the same frequency, the trapping electric fields near the junction are not zero at all times; instead, the regions of low electric field near the junction open and close at the difference frequency. An additional benefit of making the 16-pole trap operate at higher frequency is that the strength or depth of the multipole trap can be increased independent of the quadrupole ion trap.

Prestage, John↗

Atomic Clock Based On Linear Ion Trap

Highly stable atomic clock based on excitation and measurement of hyperfine transition in 199Hg+ ions confined in linear quadrupole trap by radio-frequency and static electric fields. Configuration increases stability of clock by enabling use of enough ions to obtain adequate signal while reducing non-thermal component of motion of ions in trapping field, reducing second-order Doppler shift of hyperfine transition. Features described in NPO-17758 "Linear Ion Trap for Atomic Clock." Frequency standard based on hyperfine transition described in NPO-17456, "Trapped-Mercury-Ion Frequency Standard."

Prestage, John D.↗

Microfabricated ion trap chip with in situ radio-frequency sensing

A radio-frequency (RF) surface ion trap chip includes an RF electrode and an integrated capacitive voltage divider in which an intermediate voltage node is capacitively connected between the RF electrode and a ground. A sensor output trace is connected to the intermediate voltage node.

Maunz, Peter Lukas Wilhelm↗

1 / ω electric-field noise in surface ion traps from correlated adsorbate dynamics

Ion traps are promising architectures for implementing quantum computers, but they suffer from excessive “anomalous” ion motional heating that limit their overall coherence and practicality for scalable quantum computing. The exact microscopic origins of anomalous heating remain an open question, but experiments point to adsorbates on trap electrodes as one likely source. Many different models of anomalous heating have been proposed, but these models have yet to pinpoint the atomistic origin of the experimentally observed 1/ω electric-field noise scaling seen in ion traps at frequencies between 0.1–10 MHz. In this work, we show that a model based on previously proposed surface-induced dipole fluctuations on adsorbates, but which also incorporates interparticle interaction dynamics through molecular dynamics simulations of up to multiple monolayers of adsorbates, gives rise to 1/ω frequency scaling at the MHz frequencies typically employed in ion traps. Overall, these results demonstrate that moderate-to-high densities of adsorbates can give rise to a set of activated motions that produce the 1/ω noise observed in ion traps and that collective adsorbate motions produce the observed noise spectra that a noninteracting model does not capture.

36 MATERIALS SCIENCE↗

Higher Pole Linear Traps for Atomic Clock Applications

We investigate experimentally and theoretically higher pole linear ion traps for frequency standard use. We have built a 12-pole trap and have successfully loaded ions into it from a linear quadrupole trap. By solving the Boltzmann equation describing large ion clouds where space charge interactions are important, we show that clock frequency changes due to ion number fluctuations are much smaller in ion clocks based multipole traps than comparable clocks based on quadrupole linear traps.

Prestage, John D.↗

Microwave Radiation Detector

Direct photon detector responds to microwave frequencies. Method based on trapped-ion frequency-generation standards proposed to detect radio-frequency (RF) radiation at 40.5 GHz. Technique used for directdetection (RF) communication, radar, and radio astronomy.

Lesh, J. R.↗

Compact, Highly Stable Ion Atomic Clock

A mercury-ion clock now at the breadboard stage of development (see figure) has a stability comparable to that of a hydrogen-maser clock: In tests, the clock exhibited an Allan deviation of between 2 x 10(exp -13) and 3 x 10(exp -13) at a measurement time of 1 second, averaging to about 10(exp -15) at 1 day. However, the clock occupies a volume of only about 2 liters . about a hundredth of the volume of a hydrogen-maser clock. The ion-handling parts of the apparatus are housed in a sealed vacuum tube, wherein only a getter pump is used to maintain the vacuum. Hence, this apparatus is a prototype of a generation of small, potentially portable high-precision clocks for diverse ground- and space-based navigation and radio science applications. Furthermore, this new ion-clock technology is about 100 times more stable and precise than the rubidium atomic clocks currently in use in the NAV STAR GPS Earth-orbiting satellites. In this clock, mercury ions are shuttled between a quadrupole and a 16-pole linear radio-frequency trap. In the quadrupole trap, the ions are tightly confined and optical state selection from a Hg-202 radio-frequency-discharge ultraviolet lamp is carried out. In the 16-pole trap, the ions are more loosely confined and atomic transitions resonant at frequency of about 40.507 GHz are interrogated by use of a microwave beam at that frequency. The trapping of ions effectively eliminates the frequency pulling caused by wall collisions inherent to gas-cell clocks. The shuttling of the ions between the two traps enables separation of the state-selection process from the clock microwave- resonance process, so that each of these processes can be optimized independently of the other. The basic ion-shuttling, two-trap scheme as described thus far is not new: it has been the basis of designs of prior larger clocks. The novelty of the present development lies in major redesigns of its physics package (the ion traps and the vacuum and optical subsystems) to effect the desired reduction of size to a volume of no more than a couple of liters. The redesign effort has included selection of materials for the vacuum tube, ion trap, and ultraviolet windows that withstand bakeout at a temperature of approx.450 C in preparation for sealing the tube to contain the vacuum. This part of the redesign effort follows the approach taken in the development of such other vacuum-tube electronic components as flight traveling- wave-tube amplifiers having operational and shelf lives as long as 15 years. The redesign effort has also included a thorough study of residual-gas-induced shifts of the ion-clock frequency and a study of alternative gases as candidates for use as a buffer gas within the sealed tube. It has been found that neon is more suitable than is helium, which has been traditionally used for this purpose, in that the pressure-induced frequency pulling by neon is between a third and a half of that of helium. In addition, because neon diffuses through solids much more slowly than does helium, the loss of neon by diffusion over the operational lifetime is expected to be negligible.

Prestage, John↗

Sub-mm Scale Fiber Guided Deep/Vacuum Ultra-Violet Optical Source for Trapped Mercury Ion Clocks

We demonstrate the functionality of a mercury capillary lamp with a diameter in the sub-mm range and deep ultraviolet (DUV)/ vacuum ultraviolet (VUV) radiation delivery via an optical fiber integrated with the capillary. DUV spectrum control is observed by varying the fabrication parameters such as buffer gas type and pressure, capillary diameter, electrical resonator design, and temperature. We also show spectroscopic data of the 199Hg+ hyper-fine transition at 40.5GHz when applying the above fiber optical design. We present efforts toward micro-plasma generation in hollow-core photonic crystal fiber with related optical design and theoretical estimations. This new approach towards a more practical DUV optical interface could benefit trapped ion clock developments for future ultra-stable frequency reference and time-keeping applications.

lamps↗

Dynamics Of Ions In A Radio-Frequency Quadrupole Trap

Report describes computer-simulation study of motions of various numbers of ions in Paul trap. Study part of continuing effort to understand motions of trapped charged particles (atoms, ions, molecules, or dust particles). Motions characterized in terms of heating by radio-frequency fields, formation of crystallike structures in cold clouds of trapped particles, and other phenomena important in operation of radio-frequency traps in frequency standards.

Prestage, John D.↗

Modeling of thermal-ion-driven internal kink in DIII-D high- T i plasmas

Toroidal modeling utilizing the non-perturbative magnetohydrodynamic-kinetic hybrid code MARS-K (Liu Y.Q. et al 2008 Phys. Plasmas 15 112503), to a DIII-D high-performance discharge with the core thermal ion temperature of T i ~ 13 keV, finds multiple branches of unstable internal kink (IK) modes triggered by the bounce resonance of trapped thermal ions. The range of the computed mode frequency aligns well with the bounce frequency of trapped thermal ions, confirming the nature of resonance drive for the instability. The computed mode frequency is close to that observed in experiments. Plasma toroidal flow, in particular the fast flow ($ > $10% of Alfvén speed) as in the considered DIII-D discharge, strongly stabilizes the fluid IK branch but not all of the thermal-ion-driven internal kink (TIK) branches, leaving one dominant unstable TIK branch under the experimental conditions. Plasma resistivity also significantly affects stability of the TIKs (but not much on the IK which is ideally strongly unstable) in combination with the drift kinetic drive by thermal ions. High resistivity can drive additional unstable TIK branches. Scanning the on-axis safety factor over a large range confirms robustness of the TIK triggering by thermal ions. The computed TIKs contain both the IK and the tearing components as the dominant contributions to the eigenmode structure. Furthermore, these findings, together with the experimental results reported in reference (Du X.D. et al 2021 Phys. Rev. Lett. 127 025001), strongly suggest the possibility of thermal-ion driven instabilities in ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NASA Tech Briefs, February 2011

Topics covered include: Multi-Segment Radius Measurement Using an Absolute Distance Meter Through a Null Assembly; Fiber-Optic Magnetic-Field-Strength Measurement System for Lightning Detection; Photocatalytic Active Radiation Measurements and Use; Computer Generated Hologram System for Wavefront Measurement System Calibration; Non-Contact Thermal Properties Measurement with Low-Power Laser and IR Camera System; SpaceCube 2.0: An Advanced Hybrid Onboard Data Processor; CMOS Imager Has Better Cross-Talk and Full-Well Performance; High-Performance Wireless Telemetry; Telemetry-Based Ranging; JWST Wavefront Control Toolbox; Java Image I/O for VICAR, PDS, and ISIS; X-Band Acquisition Aid Software; Antimicrobial-Coated Granules for Disinfecting Water; Range 7 Scanner Integration with PaR Robot Scanning System; Methods of Antimicrobial Coating of Diverse Materials; High-Operating-Temperature Barrier Infrared Detector with Tailorable Cutoff Wavelength; A Model of Reduced Kinetics for Alkane Oxidation Using Constituents and Species for N-Heptane; Thermally Conductive Tape Based on Carbon Nanotube Arrays; Two Catalysts for Selective Oxidation of Contaminant Gases; Nanoscale Metal Oxide Semiconductors for Gas Sensing; Lightweight, Ultra-High-Temperature, CMC-Lined Carbon/Carbon Structures; Sample Acquisition and Handling System from a Remote Platform; Improved Rare-Earth Emitter Hollow Cathode; High-Temperature Smart Structures for Engine Noise Reduction and Performance Enhancement; Cryogenic Scan Mechanism for Fourier Transform Spectrometer; Piezoelectric Rotary Tube Motor; Thermoelectric Energy Conversion Technology for High-Altitude Airships; Combustor Computations for CO2-Neutral Aviation; Use of Dynamic Distortion to Predict and Alleviate Loss of Control; Cycle Time Reduction in Trapped Mercury Ion Atomic Frequency Standards; and A (201)Hg+ Comagnetometer for (199)Hg+ Trapped Ion Space Atomic Clocks.

Source record↗

Generation Of 369.4-Nanometers Second Harmonic From A Diode Laser

Experimental laser system features polarization feedback scheme maintaining frequency lock. Generates light at wavelength of 369.4 nanometers by second-harmonic generation from 738.8-nanometers laser diode. System prototype of source of 369.4-nanometers radiation used to optically pump 2S1/2 ' 2P1/2 transition in 171Yb+ ions in lightweight, low-power trapped-ion frequency-standard apparatus.

Williams, Angelyn P.↗