Search NASA⌕ Search

SEARCH · Search NASA

Results for “Trigger”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Implementation of a level 1 trigger system using high speed serial (VXS) techniques for the 12GeV high luminosity experimental programs at Thomas Jefferson National Accelerator Facility

We will demonstrate a hardware and firmware solution for a complete fully pipelined multi-crate trigger system that takes advantage of the elegant high speed VXS serial extensions for VME. This trigger system includes three sections starting with the front end crate trigger processor (CTP), a global Sub-System Processor (SSP) and a Trigger Supervisor that manages the timing, synchronization and front end event readout. Within a front end crate, trigger information is gathered from each 16 Channel, 12 bit Flash ADC module at 4 nS intervals via the VXS backplane, to a Crate Trigger Processor (CTP). Each Crate Trigger Processor receives these 500 MB/S VXS links from the 16 FADC-250 modules, aligns skewed data inherent of Aurora protocol, and performs real time crate level trigger algorithms. The algorithm results are encoded using a Reed-Solomon technique and transmission of this Level 1 trigger data is sent to the SSP using a multi-fiber link. The multi-fiber link achieves an aggregate trigger data transfer rate to the global trigger at 8 Gb/s. The SSP receives and decodes Reed-Solomon error correcting transmission from each crate, aligns the data, and performs the global level trigger algorithms. The entire trigger system is synchronous and operates at 250 MHz with the Trigger Supervisor managing not only the front end event readout, but also the distribution of the critical timing clocks, synchronization signals, and the global trigger signals to each front end readout crate. These signals are distributed to the front end crates on a separate fiber link and each crate is synchronized using a unique encoding scheme to guarantee that each front end crate is synchronous with a fixed latency, independent of the distance between each crate. The overall trigger signal latency is <3 uS, and the proposed 12GeV experiments at Jefferson Lab require up to 200KHz Level 1 trigger rate.

43 PARTICLE ACCELERATORS↗

Nonlinear dynamical triggering of slow slip

Among the most fascinating, recent discoveries in seismology have been the phenomena of triggered slip, including triggered earthquakes and triggered-tremor, as well as triggered slow, silent-slip during which no seismic energy is radiated. Because fault nucleation depths cannot be probed directly, the physical regimes in which these phenomena occur are poorly understood. Thus determining physical properties that control diverse types of triggered fault sliding and what frictional constitutive laws govern triggered faulting variability is challenging. We are characterizing the physical controls of triggered faulting with the goal of developing constitutive relations by conducting laboratory and numerical modeling experiments in sheared granular media at varying load conditions. In order to simulate granular fault zone gouge in the laboratory, glass beads are sheared in a double-direct configuration under constant normal stress, while subject to transient perturbation by acoustic waves. We find that triggered, slow, silent-slip occurs at very small confining loads ({approx}1-3 MPa) that are smaller than those where dynamic earthquake triggering takes place (4-7 MPa), and that triggered slow-slip is associated with bursts of LFE-like acoustic emission. Experimental evidence suggests that the nonlinear dynamical response of the gouge material induced by dynamic waves may be responsible for the triggered slip behavior: the slip-duration, stress-drop and along-strike slip displacement are proportional to the triggering wave amplitude. Further, we observe a shear-modulus decrease corresponding to dynamic-wave triggering relative to the shear modulus of stick-slips. Modulus decrease in response to dynamical wave amplitudes of roughly a microstrain and above is a hallmark of elastic nonlinear behavior. We believe that the dynamical waves increase the material non-affine elastic deformation during shearing, simultaneously leading to instability and slow-slip. The inferred triggered slow-slip on the San Andreas Fault at Parkfield, CA., due to December, 2003 Mw6.5 San Simeon Earthquake (Breguier et al., Science 321, p.1478, 2008) shows very similar characteristics to what we observe in the laboratory, suggesting an extremely low in situ effective stress or a weak fault and a nonlinear-dynamical triggering mechanism.

58 GEOSCIENCES↗

Dynamic Earthquake Triggering in Southern California in High Resolution: Intensity, Time Decay, and Regional Variability

Abstract Earthquake triggering by seismic waves has been recognized as a phenomenon for nearly 30 years. However, our ability to study dynamic triggering has been limited by our ability to capture the triggering stresses accurately and record the resultant earthquakes. Here we use full waveforms from a dense seismic network and a modern, high‐resolution seismic catalog to measure triggering in Southern California from 2008 to 2017 based on interevent time ratios. We find that the fractional seismicity rate change, which we term triggering intensity or triggerability, as a function of peak strain change for the period of ∼20 s due to distant earthquakes is monotonically increasing and compatible with earlier measurements made with a disjoint data set from 1984 to 2008. A triggering strain of 1 microstrain is equivalent to the local productivity generated by an M 1.8 earthquakes. This result implies that a prediction of seismicity rate changes can be made based on recorded ground shaking using the same formalism as currently used for aftershock prediction. For a teleseismic event, this small level of triggering occurs throughout the region and thus aggregates to a regional effect. We find that the triggering rate decays after the triggerer follows an Omori‐Utsu law, but at a much slower rate than a typical aftershock sequence. The slow decay rate suggests that an ancillary process such as creep or fluid flow must be part of dynamic triggering. The prevalence of triggering in areas of creep or fluid involvement reinforces this inference. A triggering cascade of secondary earthquakes is insufficient to explain the data.

Miyazawa, Masatoshi↗

Improving Convection Trigger Functions in Deep Convective Parameterization Schemes Using Machine Learning

Abstract Deficiencies in convection trigger functions, used in deep convection parameterizations in General Circulation Models (GCMs), have critical impacts on climate simulations. A novel convection trigger function is developed using the machine learning (ML) classification model XGBoost. The large‐scale environmental information associated with convective events is obtained from the long‐term constrained variational analysis forcing data from the Atmospheric Radiation Measurement (ARM) program at its Southern Great Plains (SGP) and Manaus (MAO) sites representing, respectively, continental mid‐latitude and tropical convection. The ML trigger is separately trained and evaluated per site, and jointly trained and evaluated at both sites as a unified trigger. The performance of the ML trigger is compared with four convective trigger functions commonly used in GCMs: dilute convective available potential energy (CAPE), undilute CAPE, dilute dynamic CAPE (dCAPE), and undilute dCAPE. The ML trigger substantially outperforms the four CAPE‐based triggers in terms of the F 1 score metric, widely used to estimate the performance of ML methods. The site‐specific ML trigger functions can achieve, respectively, 91% and 93% F 1 scores at SGP and MAO. The unified trigger also has a 91% F 1 score, with virtually no degradation from the site‐specific training, suggesting the potential of a global ML trigger function. The ML trigger alleviates a GCM deficiency regarding the overprediction of convection occurrence, offering a promising improvement to the simulation of the diurnal cycle of precipitation. Furthermore, to overcome the black box issue of the ML methods, insights derived from the ML model are discussed, which may be leveraged to improve traditional CAPE‐based triggers.

54 ENVIRONMENTAL SCIENCES↗

An experimental comparison of triggered and random pulse train uncertainties

In this paper we present an experimental comparison of signal-triggered and randomly triggered based analysis algorithms of neutron multiplicity data. Traditional shift register type signal-triggered multiplicity analysis of singles, doubles and triples rates is compared with analysis using randomly triggered gates. Two methods of random gate generation are explored - non-overlapping gates (Feyrunan approach) and periodic overlapping gates (fast accidentals). Using californium sources with low, medium and high rate in combination with AmLi sources (as a surrogate for plutonium) we investigate relative standard deviation (RSD) of data in order to determine if there are parameter spaces in which one of the measurement methods should be preferred. Neutron correlation analysis is a commonly used NDA technique to assay plutonium mass. The data can be collected in two distinct ways: using signal-triggered or randomly triggered counting gates. Analysis algorithms were developed for both approaches to determine singles (S), doubles (D) and triples (7) rates from the measured sample. Currently the most commonly implemented technique to collect neutron coincidence data utilizes shift register based electronics. Shift register uses signal-triggered counting gates to generate foreground multiplicity distribution of correlated+accidental events and a random gate (opened after a predefined long delay following the signal trigger) to generate background multiplicity distribution of accidental events. Modern shift registers include fast accidental option to sample data with a fixed clock frequency. This way a set of overlapping gates is used to generate background multiplicity distributions in order to improve the measurement precision. In parallel to shift register approach the Feynman variance technique is frequently used, which utilizes set of consecutive non-overlapping gates. In general, different user communities (e.g. safeguards, nuclear material accountancy, emergency response) have used only one of the two analysis methods for the nuclear material assay. The aim of this study is to provide a systematic comparison of the precision of the measured S, D, T rates and {sup 240}Pu effective mass obtained using the above mentioned pulse train sampling techniques. In order to perform this task, a LANL developed list mode based data acquisition system is used, where the entire pulse train is recorded and subsequently analyzed. The list mode acquisition brings an essential advantage for this type of comparison, since the very same pulse train can be analyzed using signal-triggered as well as randomly triggered counting gates. The aim of this study is not only to compare the precision of signal-triggered versus random triggered sampling techniques, but also to investigate the influence of fast accidental sampling on the precision of signal-triggered results. In addition the different random sampling techniques used in safeguards are investigated. For this purpose we implement two types of random sampling - non-overlapping gates (Feynrnan approach) and periodic overlapping gates (fast accidentals). In the following sections the equations utilized in the pulse train analysis are described, experimental setup and measurement techniques are discussed and finally the results are summarized and discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improving Trigger Functions for Convective Parameterization Schemes Using GOAmazon Observations

Using observations from the Green Ocean Amazon (GOAmazon) field campaign, this study aims to improve trigger functions of convection schemes. Results show that the CAPE generation rate (dCAPE)-type triggers are the first tier and that the Bechtold and heated condensation framework (HCF) triggers are a distant second tier. The composite analysis reveals that the undilute dCAPE trigger underpredicts convection when there is bottom-heavy upward motion but overpredicts convection with low-level downward and upper-level upward motions. The empirical orthogonal function (EOF) analysis on vertical velocity shows that EOF1 (62.65%) exhibits upward motion throughout the troposphere and that EOF2 (28.05%) has lower-level upward motion and upper-level downward motion. Both of them have close relationships with precipitation, indicating the role of vertical velocity in triggering convection. The skill sensitivity analysis shows that the inclusion of 700-hPa upward motion significantly enhances the undilute dCAPE trigger. For the dilute dCAPE trigger, entrainment rate and dCAPE threshold are optimized to improve it. Opposite to dCAPE-type triggers, the Bechtold trigger overemphasizes the low-level vertical velocity and underpredicts the mature and decaying phases of long-lasting convection events. The HCF trigger overemphasizes the near-surface moist static energy and overlooks the vertical velocity. The performance of dCAPE-type triggers on various convective systems over the Amazon region is examined. The eastward-propagating systems are best represented, with only a few underpredictions in their decaying stages. The weak locally occurring systems and marginal phases of westward-propagating systems are easy to underpredict. The revised dCAPE-type triggers perform better on different convection systems and the diurnal cycle of convection.

54 ENVIRONMENTAL SCIENCES↗

Limited Dynamic Earthquake Triggering in Nevada

Dynamic triggering occurs when seismic waves from distant large earthquakes temporarily alter stress conditions along faults, potentially triggering new earthquakes hundreds to thousands of kilometers away from the source. Previous studies have linked triggered seismicity to anthropogenic activities such as geothermal, oil, and gas production. Although these activities are present in Nevada, little work has been conducted to explore dynamically triggered seismicity in Nevada. Here, we analyze a newly published, high-resolution earthquake catalog for Nevada to identify local seismicity dynamically triggered by teleseismic events (Mw≥7) from 2008 to 2023. We identify 94 dynamically triggered earthquakes concentrated in four distinct regions, which qualitatively show a modest positive correlation with geothermal well locations. Triggered seismicity in Nevada is predominantly delayed, with some instantaneously triggered by Rayleigh waves. The prevalence of delayed triggering indicates that pore fluid interactions may play a critical role in controlling dynamic triggering susceptibility in Nevada. Our results demonstrate that dynamic triggering can provide valuable insight to help identify critically stressed regions.

58 GEOSCIENCES↗

Final report on LDRD project : advanced optical trigger systems.

Advanced optically-activated solid-state electrical switch development at Sandia has demonstrated multi-kA/kV switching and the path for scalability to even higher current/power. Realization of this potential requires development of new optical sources/switches based on key Sandia photonic device technologies: vertical-cavity surface-emitting lasers (VCSELs) and photoconductive semiconductor switch (PCSS) devices. The key to increasing the switching capacity of PCSS devices to 5kV/5kA and higher is to distribute the current in multiple parallel line filaments triggered by an array of high-brightness line-shaped illuminators. Commercial mechanically-stacked edge-emitting lasers have been used to trigger multiple filaments, but they are difficult to scale and manufacture with the required uniformity. In VCSEL arrays, adjacent lasers utilize identical semiconductor material and are lithographically patterned to the required dimensions. We have demonstrated multiple-line filament triggering using VCSEL arrays to approximate line generation. These arrays of uncoupled circular-aperture VCSELs have fill factors ranging from 2% to 30%. Using these arrays, we have developed a better understanding of the illumination requirements for stable triggering of multiple-filament PCSS devices. Photoconductive semiconductor switch (PCSS) devices offer advantages of high voltage operation (multi-kV), optical isolation, triggering with laser pulses that cannot occur accidentally in nature, low cost, high speed, small size, and radiation hardness. PCSS devices are candidates for an assortment of potential applications that require multi-kA switching of current. The key to increasing the switching capacity of PCSS devices to 5kV/5kA and higher is to distribute the current in multiple parallel line filaments triggered by an array of high-brightness line-shaped illuminators. Commercial mechanically-stacked edge-emitting lasers have been demonstrated to trigger multiple filaments, but they are difficult to scale and manufacture with the required uniformity. As a promising alternative to multiple discrete edge-emitting lasers, a single wafer of vertical-cavity surface-emitting lasers (VCSELs) can be lithographically patterned to achieve the desired layout of parallel line-shaped emitters, in which adjacent lasers utilize identical semiconductor material and thereby achieve a degree of intrinsic optical uniformity. Under this LDRD project, we have fabricated arrays of uncoupled circular-aperture VCSELs to approximate a line-shaped illumination pattern, achieving optical fill factors ranging from 2% to 30%. We have applied these VCSEL arrays to demonstrate single and dual parallel line-filament triggering of PCSS devices. Moreover, we have developed a better understanding of the illumination requirements for stable triggering of multiple-filament PCSS devices using VCSEL arrays. We have found that reliable triggering of multiple filaments requires matching of the turn-on time of adjacent VCSEL line-shaped-arrays to within approximately 1 ns. Additionally, we discovered that reliable triggering of PCSS devices at low voltages requires more optical power than we obtained with our first generation of VCSEL arrays. A second generation of higher-power VCSEL arrays was designed and fabricated at the end of this LDRD project, and testing with PCSS devices is currently underway (as of September 2008).

36 MATERIALS SCIENCE↗

Firearm trigger assembly

A firearm trigger assembly for use with a firearm includes a trigger mounted to a forestock of the firearm so that the trigger is movable between a rest position and a triggering position by a forwardly placed support hand of a user. An elongated trigger member operatively associated with the trigger operates a sear assembly of the firearm when the trigger is moved to the triggering position. An action release assembly operatively associated with the firearm trigger assembly and a movable assembly of the firearm prevents the trigger from being moved to the triggering position when the movable assembly is not in the locked position.

Crandall, David L↗

Real Time Data Analysis With the ATLAS Trigger at the LHC in Run-2

The trigger selection capabilities of the ATLAS detector have been significantly enhanced for the LHC Run- 2 in order to cope with the higher event rates and with the large number of simultaneous interactions (pile-up) per protonproton bunch crossing. A new hardware system, designed to analyse real time event-topologies at Level-1 came to full use in 2017. A hardware-based track reconstruction system, expected to be used real-time in 2018, is designed to provide track information to the high-level software trigger at its full input rate. The high-level trigger selections are largely relying on offline-like reconstruction techniques, and in some cases multivariate analysis methods. Despite the sudden change in LHC operations during the second half of 2017, which caused an increase in pile-up and therefore also in CPU usage of the trigger algorithms, the set of triggers (so called trigger menu) running online has undergone only minor modifications thanks to the robustness and redundancy of the trigger system, and the use of a levelling luminosity scheme in agreement with LHC and other experiments. Here, this presentation gives a brief yet comprehensive review of the real-time performance of the ATLAS trigger system in 2017. Considerations will be presented on the most relevant parameters of the trigger (efficiency to collect signal and output data rate) as well as details on some aspects of the algorithms which are run real-time on the High Level Trigger CPU farm.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of the ATLAS RPC detector and Level-1 muon barrel trigger at √(s)=13 TeV

The ATLAS experiment at the Large Hadron Collider (LHC) employs a trigger system consisting of a first-level hardware trigger (L1) and a software-based high-level trigger. The L1 muon trigger system selects muon candidates, assigns them to the correct LHC bunch crossing and classifies them into one of six transverse-momentum threshold classes. The L1 muon trigger system uses resistive-plate chambers (RPCs) to generate the muon-induced trigger signals in the central (barrel) region of the ATLAS detector. The ATLAS RPCs are arranged in six concentric layers and operate in a toroidal magnetic field with a bending power of 1.5 to 5.5 Tm. The RPC detector consists of about 3700 gas volumes with a total surface area of more than 4000 m2. This paper reports on the performance of the RPC detector and L1 muon barrel trigger using 60.8 fb-1 of proton-proton collision data recorded by the ATLAS experiment in 2018 at a centre-of-mass energy of 13 TeV. Detector and trigger performance are studied using Z boson decays into a muon pair. Measurements of the RPC detector response, efficiency, and time resolution are reported. Measurements of the L1 muon barrel trigger efficiencies and rates are presented, along with measurements of the properties of the selected sample of muon candidates. Measurements of the RPC currents, counting rates and mean avalanche charge are performed using zero-bias collisions. Finally, RPC detector response and efficiency are studied at different high voltage and front-end discriminator threshold settings in order to extrapolate detector response to the higher luminosity expected for the High Luminosity LHC.

47 OTHER INSTRUMENTATION↗

Design of the Trigger Interface and Distribution Board for CEBAF 12 GeV Upgrade

The design of the Trigger Interface and Distribution (TID) board for the 12 GeV Upgrade at the Continuous Electron Beam Accelerator Facility (CEBAF) at TJNAL is described. The TID board distributes a low jitter system clock, synchronized trigger, and synchronized multi-purpose SYNC signal. The TID also initiates data acquisition for the crate. With the TID boards, a multi-crate system can be setup for experiment test and commissioning. The TID board can be selectively populated as a Trigger Interface (TI) board, or a Trigger Distribution (TD) board for the 12 GeV upgrade experiments. When the TID is populated as a TI, it can be located in the VXS crate and distribute the CLOCK/TRIGGER/SYNC through the VXS P0 connector; it can also be located in the standard VME64 crate, and distribute the CLOCK/TRIGGER/SYNC through the VME P2 connector or front panel. It initiates the data acquisition for the front crate where the TI is positioned in. When the TID is populated as a TD, it fans out the CLOCK/TRIGGER/SYNC from trigger supervisor to the front end crates through optical fibres. The TD monitors the trigger processing on the TIs, and gives feedback to the TS for trigger flow control. Field Programmable Gate Arrays (FPGA) is utilised on TID board to provide programmability. The TID boards were intensively tested on the bench, and various setups.

CEBAF upgrade↗

Design of the Trigger Interface and Distribution Board for CEBAF 12 GeV Upgrade

The design of the Trigger Interface and Distribution (TID) board for the 12 GeV Upgrade at the Continuous Electron Beam Accelerator Facility (CEBAF) at TJNAL is described. The TID board distributes a low jitter system clock, synchronized trigger, and synchronized multi-purpose SYNC signal. The TID also initiates data acquisition for the crate. With the TID boards, a multi-crate system can be setup for experiment test and commissioning. The TID board can be selectively populated as a Trigger Interface (TI) board, or a Trigger Distribution (TD) board for the 12 GeV upgrade experiments. When the TID is populated as a TI, it can be located in the VXS crate and distribute the CLOCK/TRIGGER/SYNC through the VXS P0 connector; it can also be located in the standard VME64 crate, and distribute the CLOCK/TRIGGER/SYNC through the VME P2 connector or front panel. It initiates the data acquisition for the front crate where the TI is positioned in. When the TID is populated as a TD, it fans out the CLOCK/TRIGGER/SYNC from trigger supervisor to the front end crates through optical fibres. The TD monitors the trigger processing on the TIs, and gives feedback to the TS for trigger flow control. Field Programmable Gate Arrays (FPGA) is utilised on TID board to provide programmability. The TID boards were intensively tested on the bench, and various setups.

CEBAF upgrade↗

A novel in situ trigger combination method

Searches for rare physics processes using particle detectors in high-luminosity colliding hadronic beam environments require the use of multi-level trigger systems to reject colossal background rates in real time. In analyses like the search for the Higgs boson, there is a need to maximize the signal acceptance by combining multiple different trigger chains when forming the offline data sample. In such statistically limited searches, datasets are often amassed over periods of several years, during which the trigger characteristics evolve and system performance can vary significantly. Reliable production cross-section measurements and upper limits must take into account a detailed understanding of the effective trigger inefficiency for every selected candidate event. We present as an example the complex situation of three trigger chains, based on missing energy and jet energy, that were combined in the context of the search for the Higgs (H) boson produced in association with a $W$ boson at the Collider Detector at Fermilab (CDF). We briefly review the existing techniques for combining triggers, namely the inclusion, division, and exclusion methods. We introduce and describe a novel fourth in situ method whereby, for each candidate event, only the trigger chain with the highest a priori probability of selecting the event is considered. We compare the inclusion and novel in situ methods for signal event yields in the CDF $WH$ search. This new combination method, by virtue of its scalability to large numbers of differing trigger chains and insensitivity to correlations between triggers, will benefit future long-running collider experiments, including those currently operating on the Large Hadron Collider.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Level-1 Trigger and DAQ system of the GlueX experiment

The goal of the GlueX detector at Jefferson Lab is to study fundamental questions of the quantum chromodynamics, i.e., the nature of confinement of gluons and quarks. The detector's design is optimized to measure the spectrum of exotic mesons that are expected to be produced in interactions of 8.4 - 9.0 GeV linearly polarized photons with a liquid hydrogen target. The GlueX trigger and DAQ electronics is based on pipelined TDC boards and FADC boards running at a 250 MHz clock. The trigger logic is implemented on special purpose programmable electronics boards with Field-Programmable Gate Array chips. Two types of boards are used: Crate Trigger Processors and Global Trigger Processors. All trigger electronics is hosted in VXS crates. The Level-1 trigger should reduce the 200 MHz electromagnetic rate and the 400 kHz hadronic rate to 200 kHz total rate. The trigger algorithm makes use of a measurement of the energy deposition in two electromagnetic calorimeters and hit counts in the start counter, the time-of-flight detector, and the tagger hodoscopes. We will present the trigger and DAQ design of the GlueX experiment and describe the Level-1 trigger algorithm in detail..

Somov, Alexander↗

Occurrence frequencies of IMF triggered and nontriggered substorms

The occurrence of triggered and nontriggered substorm are examined in light of current interest in such issues as substorm identification, IMF By variations, and potentially undetected small-scale solar wind perturbation. Global substorms are identified using a sudden, persistent decrease in the AL index. The onset of this global expansion is taken to be the time of the Pi 2 burst nearest in time to the beginning of the AL, decrease. IMF triggers were identified both subjectively through visual scanning of the data and automatically with a computer algorithm. Both northward turnings of the IMF Bz and decreases in the amplitude of the By component were considered as possible triggers. Two different solar wind monitors were used in the investigation: IMP-8 in a circular orbit with a distance 12 to approx.35 Re to the Earth-Sun line and ISEE-2 in an elliptical orbit with a distance only 5 to approx.10 Re to the Earth-Sun line. The IMP-8 results show that the triggering probability does not depend on the distance of the monitor from the Earth-Sun line in the range 12-35 Re. The ISEE dataset shows that closer than 12 Re the triggering probability is the same as it is in the IMP-8 data set. Thus there appears to be no dependence of triggering on the location of the monitor provided it is within 35 Re of the Earth. We also demonstrate that including the By component does not significantly increase the probability of substorm triggering. Approximately 60% of all substorms appear to be triggered. Of the 40% for which we could not identify a trigger, 10% occurred while the IMF was northward. The data suggest that substorm onset is a consequence of an internal magnetospheric instability that is highly sensitive to changes in magnetospheric convection induced by a sudden change in the IMF, but that these changes are not always necessary.

Hsu, Tung-Shin↗

Video event trigger and tracking system using fuzzy comparators

A video observation method and apparatus, the apparatus having a frame storage mechanism, a dividing mechanism, a plurality of fuzzy comparators and a trigger signal mechanism. The frame storage mechanism stores at least one non-current video frame of a viewing field. The dividing mechanism divides a current video frame of the viewing field and the at least one non-current video frame into a plurality of corresponding trigger sections. The plurality of fuzzy comparators each compare and detect a fuzzy logic difference between one trigger section of the current video frame and the corresponding trigger sections of the at least one non-current video frame, the number of fuzzy comparators being selected so that every trigger section of the current video frame is compared. The trigger signal mechanism provides a trigger signal when a fuzzy logic difference is detected between any of the corresponding current and non-current trigger sections. A video observation mechanism and data reducing mechanism may be included with the above apparatus or alone with only a frame storage mechanism, a single generic comparator and a trigger signal mechanism. The video observation mechanism provides a video data stream, wherein each pixel of each frame of a viewing field is provided as multiple bits of data. The data reducing mechanism reduces each set of multiple bits of data which correspond to each pixel to one bit of binary data based on whether the pixel has a level of grey which is above or below a threshold level of grey.

Williams, Glenn L.↗