Characterization of the environmentally induced chemical transformation of UF 4
The overall objective is to develop an initial chemical and structural basis for understanding UF 4 hydrolysis in the environment.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
The overall objective is to develop an initial chemical and structural basis for understanding UF 4 hydrolysis in the environment.
This project demonstrated that a device using majority Commercial Off the Shelf (COTS) components could be used to collect uranium hexafluoride samples safely from gaseous or solid sources. The device was based on the successful Cristallini method developed by ABACC over the past 10 years. The system was designed to capture and store the UF 6 as an inert fluoride salt to ease transportation regulations. In addition, the method was considerably faster than traditional cryogenic methods, collected enough material to perform analyses without undue waste, and could be used either inside a facility or in the storage yard.
This unit process provides the material inputs for the construction of a steel storage container for UF 6 storage and transportation. Through the parameters, the size of the container can be varied for the applicable type: 48X, 48Y, or 30B. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=643B7D37-C898-4319-9317-85A084D22E20
In this work, a method for using ratios of passive gamma ray measurements to determine the time since the filling of UF 6 cylinders was explored. This method uses the 186 keV gamma ray emitted by 235 U and the 1,275 keV gamma ray that results from interactions of alpha particles in fluorine. Studies were made using MCNP models of both 30B cylinders and smaller 5A cylinders. Results indicate that for enrichments at or above that of natural uranium, this approach may provide a method for determining age up to 10 years or identifying whether the age is greater than 10 years, even if the uranium enrichment is unknown. The calculated results show the same behavior as the results of a recent measurement campaign, indicating the possibility of using this method for real-world cylinders.
A field scoping study was conducted to evaluate the ability of Cd-Zn-Te (CZT) detectors and High Purity Germanium (HPGe) detectors to quantify the U-235 enrichment in UF 6 samples collected on alumina in P-10 tubes, similar to the Cristillini method of sample collection for analysis by mass spectrometry. With in-field gamma-ray spectroscopy methods, international safeguards and verification missions could benefit from quick in-field confirmation of declared enrichment values prior to or without the need for additional shipping, sample preparation and analysis. Samples of depleted (DU), low-enriched (LEU) and high-assay low-enriched (HALEU) uranium were collected on Cristillini-type alumina in P-10 tubes and measured with two H3D, Inc. M400 CZT detectors as well as a Canberra Falcon HPGe detector. The M400 detectors were able to confirm enrichment in the DU and LEU samples but not the HALEU sample in measurements 8-40 hrs after collection. The Falcon system was able to confirm enrichment in all three samples. Improvements in detector geometry, increase in number of detectors as well as increase sample mass loading may allow measurement of U-235 enrichment in these types of samples within 4-8hrs of collection with 5-10% uncertainty.
This project is developing an in-field alpha spectrometry system for the purpose of assaying grab samples of uranium hexafluoride (UF 6 ) and determining uranium enrichment. This system will accommodate Single-Use Destructive Assay (SUDA) samples (PNNL) and be field portable.
Under the auspices of the US Department of Energy/National Nuclear Security Agency’s Nuclear Reference Material Program (NRMP), the Material Signatures and Isotopic Standards (MSIS) group of Oak Ridge National Laboratory was tasked with analyzing five UF 6 filled P-10 tubes for uranium isotopic composition. This report documents the results of the measurements performed by the MSIS group’s International Organization for Standardization/International Electrotechnical Commission 17025:2017 accredited operating procedure CSD-AM-CIMS-IN20, Determination of Uranium and Plutonium Isotopic Composition using Thermal Ionization Mass Spectrometry, and in accordance with the quality assurance plan as described in QAP-X-96-CSD/RML-001, Nuclear Analytical Chemistry Laboratory Section Quality Assurance Plan.
The estimate of absorbed dose to individual organs of a space crewmember is affected by the geometry of the anatomical model of the astronaut used in the radiation transport calculation. For astronaut dosimetry, NASA currently uses the computerized anatomical male (CAM) and computerized anatomical female (CAF) stylized phantoms to represent astronauts in its operational radiation dose analyses. These phantoms are available in one size and in two body positions. In contrast, the UF Hybrid Adult Male and Female (UFHADM and UFHADF) phantoms have organ shapes based on actual CT data. The surfaces of these phantoms are defined by non-uniform rational B-spline surfaces, and are thus flexible in terms of body morphometry and extremity positioning. In this study, UFHADM and UFHADF are scaled to dimensions corresponding to 5th, 50th, and 95th percentile (PCTL) male and female astronauts. A ray-tracing program is written in Visual Basic 2008, which is then used to create areal density maps for dose points corresponding to various organs within the phantoms. The areal density maps, along with appropriate space radiation spectra, are input into the NASA program couplet HZETRN/BRYNTRN, and organ doses are calculated. The areal density maps selected tissues and organs of the 5th, 50th, and 95th PCTL male and female phantoms are presented and compared. In addition, the organ doses for the 5th, 50th, and 95th PCTL male and female phantoms are presented and compared to organ doses for CAM and CAF.
Emissions are a central component of atmospheric chemistry models. The Harmonized Emissions Component (HEMCO) is a software component for computing emissions from a user-selected ensemble of emission inventories and algorithms. It allows users to re-grid, combine, overwrite, subset, and scale emissions from different inventories through a configuration file and with no change to the model source code. The configuration file also maps emissions to model species with appropriate units. HEMCO can operate in offline stand-alone mode, but more importantly it provides an online facility for models to compute emissions at runtime. HEMCO complies with the Earth System Modeling Framework (ESMF) for portability across models. We present a new version here, HEMCO 3.0, that features an improved three-layer architecture to facilitate implementation into any atmospheric model and improved capability for calculating emissions at any model resolution including multiscale and unstructured grids. The three-layer architecture of HEMCO 3.0 includes (1) the Data Input Layer that reads the configuration file and accesses the HEMCO library of emission inventories and other environmental data, (2) the HEMCO Core that computes emissions on the user-selected HEMCO grid, and (3) the Model Interface Layer that re-grids (if needed) and serves the data to the atmospheric model and also serves model data to the HEMCO Core for computing emissions dependent on model state (such as from dust or vegetation). The HEMCO Core is common to the implementation in all models, while the Data Input Layer and the Model Interface Layer are adaptable to the model environment. Default versions of the Data Input Layer and Model Interface Layer enable straightforward implementation of HEMCO in any simple model architecture, and options are available to disable features such as re-gridding that may be done by independent couplers in more complex architectures. The HEMCO library of emission inventories and algorithms is continuously enriched through user contributions so that new inventories can be immediately shared across models. HEMCO can also serve as a general data broker for models to process input data not only for emissions but for any gridded environmental datasets. We describe existing implementations of HEMCO 3.0 in (1) the GEOS-Chem “Classic” chemical transport model with shared-memory infrastructure, (2) the high-performance GEOS-Chem (GCHP) model with distributed-memory architecture, (3) the NASA GEOS Earth System Model (GEOS ESM), (4) the Weather Research and Forecasting model with GEOS-Chem (WRF-GC), (5) the Community Earth System Model Version 2 (CESM2), and (6) the NOAA Global Ensemble Forecast System – Aerosols (GEFS-Aerosols), as well as the planned implementation in the NOAA Unified Forecast System (UFS). Implementation of HEMCO in CESM2 contributes to the Multi-Scale Infrastructure for Chemistry and Aerosols (MUSICA) by providing a common emissions infrastructure to support different simulations of atmospheric chemistry across scales.
With the growing scarcity of freshwater, innovative process design mechanisms like Reverse Osmosis (RO) are increasingly gaining attention among water treatment utilities to address the rising demand. Ensuring reliable water production necessitates efficient resource utilization, minimizing downtime in (ultra-filtration) UF systems. Recent advancements in machine learning (ML) have enabled the development of accurate data-driven models for Model Predictive Control (MPC), often requiring minimal prior knowledge of underlying physical processes. In this study, we present predictive regression models based on Random Forest (RF) and Auto-Regressive (AR) approaches to forecast the initial Trans-Membrane Pressure (TMP) for each filtration cycle in data generated by Direct Potable Reuse (DPR) systems. The proposed RF-based model demonstrates superior performance compared to baseline methods, including historical mean, Last Observation Carried Forward (LOCF), and naïve AR models, across various forecasting horizons in terms of root mean square error (RMSE) metric. To evaluate how different classes of process variables contribute to TMP dynamics over time, we examine the feature importance of independent covariates across multiple forecast horizons. This analysis provides insight into the temporal relevance of operational and sensor-derived features, guiding control and monitoring strategies. Additionally, the impact of hyperparameter tuning on TMP prediction performance is studied for both direct and recursive RF modelling approaches across increasing forecast horizons. Accurate prediction of initial TMP is critical for optimizing RO operations, as it enables the development of robust modelling frameworks by accurately estimating membrane fouling trends, thereby enhancing process efficiency and long-term reliability. The demonstrated efficacy of the RF-based approach highlights its potential as a tool for real-time decision-making in water treatment systems, paving the way for advanced process optimization and sustainable water resource management.
U1F is Tungsten Carbide-like structured and crystallizes in the hexagonal P-6m2 space group. The structure is three-dimensional. U is bonded in a 6-coordinate geometry to six equivalent F atoms. All U–F bond lengths are 2.67 Å. F is bonded in a 6-coordinate geometry to six equivalent U atoms.
PurposeThis study was designed to assess midterm outcome of uterine artery embolisation (UAE) for women with therapy-resistant adenomyosis using polyzene F-coated hydrogel microspheres.MethodsBetween September 2006 and January 2010, 29 consecutive women with adenomyosis (15 in combination with fibroids) were treated with UAE using polyzene F-coated hydrogel microspheres. Junction zone thickness was assessed with MRI at baseline and 3 months. Women filled out the uterine fibroid symptom and quality of life questionnaire at baseline, 3 months and after a mean clinical follow-up of 37 months (median 35, range 29–64 months).ResultsAt baseline, symptom severity score of 29 women was mean 67 (median 72, range 23–100). At 3 months, this score decreased to mean 22 (median 15, range 0–66) and mean 15 (median 17, range 0–34) at final follow-up. At final follow-up of mean 37 months (median 35, range 29–64 months), 22 of 29 (76 %) patients were asymptomatic. Of these 22 women, 3 underwent a second UAE at 6, 7, and 14 months. The remaining seven patients clinically improved but still had symptoms; one underwent a hysterectomy. There was no difference in outcome between women with pure adenomyosis and women with additional fibroids. The junction zone of 4 women with additional therapy was significantly thicker compared with the remaining 25 patients.ConclusionsIn women with therapy resistant adenomyosis, UAE using polyzene F-coated hydrogel microspheres resulted in 3 years preservation of the uterus in 28 of 29 (97 %) with good clinical outcome in the vast majority of patients. Initial thickness of the junction zone is related to additional therapy.
In recent years, the International Atomic Energy Agency (IAEA) has pursued innovative techniques and an integrated suite of safeguards measures to address the verification challenges posed by the front end of the nuclear fuel cycle. Among the unattended instruments currently being explored by the IAEA is an Unattended Cylinder Verification Station (UCVS), which could provide automated, independent verification of the declared relative enrichment, 235 U mass, total uranium mass, and identification for all declared uranium hexafluoride cylinders in a facility (e.g., uranium enrichment plants and fuel fabrication plants). Under the auspices of the United States and European Commission Support Programs to the IAEA, a project was undertaken to assess the technical and practical viability of the UCVS concept. The first phase of the UCVS viability study was centered on a long-term field trial of a prototype UCVS system at a fuel fabrication facility. A key outcome of the study was a quantitative performance evaluation of two nondestructive assay (NDA) methods being considered for inclusion in a UCVS: Hybrid Enrichment Verification Array (HEVA), and Passive Neutron Enrichment Meter (PNEM). This paper provides a description of the UCVS prototype design and an overview of the long-term field trial. In conclusion, analysis results and interpretation are presented with a focus on the performance of PNEM and HEVA for the assay of over 200 “typical” Type 30B cylinders, and the viability of an “NDA Fingerprint” concept as a high-fidelity means to periodically verify that material diversion has not occurred.
The University of Florida Training Reactor (UFTR) is a 100-kW ARGONAUT type reactor with a unique design such that a large volume of air passes through the core, producing and releasing significant quantities of 41 Ar. Once released, the radioargon is dispersed throughout the atmosphere and decays by a 1294 keV gamma ray emission. This quantified, validated, and controlled 41 Ar plume can be utilized to verify and validate atmospheric transport models (ATMs). This is accomplished by coupling an ATM with MCNP and comparing the results to experimental measurements. For this study, an in-house developed Gaussian dispersion model and the EPA approved Gaussian model AERMOD were coupled with MCNP to simulate the results of a six hour measurement taken on May 8th, 2018. For the measurements and simulations, a grid of seven NaI detectors were placed in four different rooftop locations near the UFTR plume stack. With easterly winds dominating during the morning and early afternoon, both the measurement results and simulations displayed a higher 41 Ar photon count rate on the detectors west of the plume stack throughout the day. Overall, the AERMOD simulations produced better results when compared to the in-house model, particularly for the detectors placed east and west of the plume stack. While some of the AERMOD data showed a strong correlation with the measurements, the results remain inconsistent. Here, due to the varying accuracy of the simulation results, it is theorized that the relationship between measurement results and simulations will improve with the use of localized weather information or the utilization of non-Gaussian dispersion models.
Three data analysis methods were compared for gamma ray spectra collected by planar and coaxial high-purity germanium detectors (HPGe) on thick-walled uranium hexafluoride cylinders. The cylinder contents range from natural to low-enriched uranium (4.95% 235 U). Each spectrum was analyzed with the traditional 185.7 keV enrichment meter method, a 185.7/1001 keV ratio method, and the Fixed Energy Response Function Analysis with Multiple Efficiency (FRAM) software that utilizes low- and high-energy gamma rays and X-rays. When results for all cylinders were compared, the enrichment meter method and the 185.7/1001 keV peak ratio method consistently provided the most accurate data for all detector types. The error on the enrichment calculations analyzed with FRAM did not meet the international target value whereas those calculated with the enrichment meter and ratio method did. Enrichments calculated by FRAM were found to skew to higher values on natural uranium and to lower values on low-enriched uranium. FRAM calculated the least-precise enrichments; replicate analyses of single cylinders resulted in 235 U values that varied by as much as 19%. FRAM does have the significant advantages in that it does not require the use of calibration cylinders, infinite thickness criteria are not necessary, and it can be applied to any HPGe detector. Finally, if calibration cylinders are available, the enrichment meter and 185.7/1001 peak ratio are the recommended methods as they are the most accurate and precise.
Not provided.