At least 73 records · Page 4

Structural Characterization and Gas Reactions of Small Metal Particles by High Resolution In-situ TEM and TED

A commercial electron microscope with flat-plate upper pole piece configuration of the objective lens and top entry specimen introduction was modified to obtain 5 x 10 to the minus 10th power mbar pressure at the site of the specimen while maintaining the convenience of a specimen airlock system that allows operation in the 10 to the 10th power mbar range within 15 minutes after specimen change. The specimen chamber contains three wire evaporation sources, a specimen heater, and facilities for oxygen or hydrogen plasma treatment to clean as-introduced specimens. Evacuation is achieved by dural differential pumping, with fine entrance and exit apertures for the electron beam. With the microscope operating at .000001 mbar, the first differential pumping stage features a high-speed cryopump operating in a stainless steel chamber that can be mildly baked and reaches 1 x 10 to the minus 8th power mbar. The second stage, containing the evaporation sources and a custom ionization gauge within 10 cm from the specimen, is a rigorously uncompromised all-metal uhv-system that is bakable to above 200 C throughout and is pumped with an 80-liter ion pump. Design operating pressures and image quality (resolution of metal particles smaller than 1 nm in size) was achieved.

Heinemann, K.↗

The Correlation of Structural, Chemical, and Electronic Properties of Small Metal Particles and Their Alloys

The low pressure interaction of CO with small Ru particles supported on ultrahigh vacuum (UHV) cleaved mica was studied using flash thermal desorption, Auger electron microscopy, transmission electron microscopy, and transmission electron diffraction. Average particle sizes for these experiments varied between 1.2 and 16 nm. A careful search for CO decomposition on the Ru particles revealed no evidence of dissociaiton over a temperature range and pressure range of 300 to 550 C and 10 to the minus 11th power to 10 to the minus 6th millibar, respectively. Cas and heat treatments caused significant morphological changes and dispersion in the Ru particles, which affected CO desorptiom These effects were dependent on the particle size.

Source record↗

Growth and characterization of epitaxial SrF2 on InP(100)

The epitaxial growth of 100-262.5-nm SrF2 films on n-type and p-type (100)InP in a conventional baked UHV system at base pressure about 200 ptorr, temperature 250-350 C, and growth rate from less than 100 to about 200 pm/s. Substrates are chemicomechanically polished, degreased, bombarded with 500-eV Ar ions for 3-4 min at 350 C, and annealed for 23-30 min at 350 C, producing a slightly In-rich (In/P = 1.02) In-island-free surface with a (4 x 1) or (1 x 1) LEED structure. Films grown at 350 C and less than 100 pm/s are found to be smooth and free of cracks in most cases, with a highly faceted (1 x 1) LEED structure. The electrical properties of the SrF2 films are found to be acceptable only when the ohmic contacts are applied prior to the substrate prior to SrF2 growth.

Sinharoy, S.↗

CO oxidation studies over supported noble metal catalysts and single crystals: A review

The catalytic oxidation of CO over noble metal catalysts is reviewed. Results obtained on supported noble metal catalysts and single crystals both at high pressures and under UHV conditions are compared. The underlying causes which result in surface instabilities and multiple steady-state oscillations are considered, in particular, the occurrence of hot spots. CO islands of reactivity, surface oxide formation and phase transformations under oscillatory conditions are discussed.

Boecker, Dirk↗

A high flux source of swift oxygen atoms

A source of swift oxygen atoms is described which has several unique features. A high current ion beam is produced by a microwave discharge, accelerated to 10 keV and the mass selected by a modified Du Pont 21-110 mass spectrometer. The O(+) beam exciting the mass spectrometer is focused into a rectangular shape with an energy spread of less than 1 eV. The next section of the machine decelerates the ion beam into a counterpropagating electron beam in order to minimize space charge effects. After deceleration, the ion beam intersects at 90 deg, a neutral oxygen atom beam, which via resonant charge exchange produces a mixture of O(+) and O. Any remaining O(+) are swept out of the beam by an electric field and differentially pumped away while the desired O beam, collimated by slits, impinges on the target. In situ monitoring of the target surface is done by X-ray photoelectron or Auger spectroscopy. Faraday cups provide flux measurements in the ion sections while the neutral flux is determined by a special torsion balance or by a quadrupole mass spectrometer specially adapted for swift atoms. While the vacuum from the source through the mass spectrometer is maintained by diffusion pumps, the rest of the machine is UHV.

Fink, M.↗

Hypervelocity atomic oxygen source for the study of atom-surface interactions

Planned improvements in an electric discharge heated atomic oxygen beam source are described which will provide 6 to 7 kms(-1) beams of atomic oxygen with a flux of 10(16) cm(-2) s(-1) at 50 cm distance from the source aperture. A major advance will be the use of a zone of silence nozzle-skimmer arrangement which is necessitated by the need for high source flux and performance. It is anticipated that a Phase 2 program would provide for the fabrication of a two stage vacuum system which would be suitable for bolting on to a UHV (ultrahigh vacuum) surface study apparatus.

Freedman, A.↗

Study of Staebler-Wronsky degradation effect in a Si:H based P-I-N solar cells

The objective of this study is to improve the stability and efficiency of thin solar cells with emphasis on a-Si:H devices. The research project was broken down into three main phases. The first involves designing and building a UHV glow discharge system; the second involves making good quality films and eventually efficient cells; the final phase will be analytical.

Naseem, Hameed↗

Effect of substrate preparation on the structure and chemisorption properties of Pd/MgO model catalyst

Pd/MgO model catalysts are prepared by vapor deposition of Pd particles on MgO thin films which are deposited, at different temperatures, on UHV cleaved mica. MgO films and Pd particles are characterized in situ by Auger electron spectroscopy and energy-loss spectroscopy and ex situ by transmission electron microscopy. Succesive temperature programmed desorption (TPD) of CO shows a different evolution of the morphology of the Pd particles deposited on MgO films prepared at low and high temperature. In addition, on MgO prepared at low temperature, the smallest particles show a continuous decay of CO adsorption during TPD due to contamination by support species.

Henry, C. R.↗

Research and development of HgZnTe as an infrared material

Interfacial morphology and Fermi level pinning behavior at the interfaces of Al, Ag, and Pt with UHV-cleaved CdTe and ZnTe have been studied using X-ray and ultraviolet photoemission spectroscopies. Results are compared to metal/HgCdTe interface formation, where the weak HgTe bond and consequent ease of Hg loss strongly influence semiconductor disruption and metal-semiconductor intermising. For Al/CdTe, the strong Al-Te reaction yields a significantly more extensive Al-Te reacted region than has been observed for HgCdTe. The Al/ZnTe interface is observed to be more abrupt than Al/CdTe. The final Fermi level pinning positions, Ef-Evbm for Al, Ag, and Pt on p-type CdTe and p-ZnTe have been determined. Efi is found to be roughly the same for both CdTe and ZnTe, with the value for ZnTe lying approximately 0.2 eV closer to the VBM for all three metals. From these results, one would expect Schottky barriers of about the same height for these metals on p-CdTe and p-ZnTe; and also that, in principle, metal interfaces with the two alloys HgCdTe and HgZnTe would have the same properties. Comparisons and implications for electrical behavior of metal contacts to the alloys are discussed.

Wahi, A. K.↗

CdTe and ZnTe metal interface formation and Fermi-level pinning

Interfacial morphology and Fermi-level pinning behavior at the interfaces of Al, Ag, and Pt with UHV-cleaved CdTe and ZnTe are studied using X-ray photoelectron and ultraviolet photoemission spectroscopies. Results are compared to metal/HgCdTe interface formation. For Al/CdTe, a case is found where significantly greater intermixing occurs in CdTe than seen on HgCdTe. The Al/ZnTe interface is also more abrupt than Al/CdTe. Band bending results for interfaces of all three metals with p-CdTe and p-ZnTe are presented and implications for metal/HgZnTe interface formation are considered.

Wahi, A. K.↗

Development of a quadrupole-based Secondary-Ion Mass Spectrometry (SIMS) system at Lewis Research Center

The design, construction, and initial use of an ion microprobe to carry out secondary ion mass spectrometry (SIMS) of solid samples is reported. The system is composed of a differentially pumped custom-made UHV (Ultra High Vacuum) chamber, a quadrupole mass spectrometer and a telefocus A-DIDA ion gun with the capability of producing beams of Cesium, as well as inert and reactive gases. The computer control and acquisition of the data were designed and implemented using a personal computer with plug-in boards, and external circuitry built as required to suit the system needs. The software is being developed by using a FORTH-like language. Initial tests aimed at characterizing the system, as well as preliminary surface and depth-profiling studies are presently underway.

Vargas-Aburto, Carlos↗

Surface defects and chemistry on the SnO2(110) surface

A variety of ultrahigh vacuum (UHV) surface science techniques have been used to characterize the structural, electronic and chemical properties of SnO2(110), a model catalytic surface. Two types of surface oxygen vacancies have been identified, each associated with different band gap (defect) electronic states. Adsorption experiments show that the interaction of simple gases with this surface occurs primarily through these oxygen vacancies and can show site-specificity to only one of the two types of vacancies.

Cox, David F.↗

Characterization of the surfaces of platinum/tin oxide based catalysts by Fourier Transform Infrared Spectroscopy (FTIR)

A Pt/SnO2 catalyst has been developed at NASA Langley that is effective for the oxidation of CO at room temperature (1). A mechanism has been proposed to explain the effectiveness of this catalyst (2), but most of the species involved in this mechanism have not been observed under actual catalytic conditions. A number of these species are potentially detectable by Fourier Transform Infrared Spectroscopy (FTIR), e.g., HOSnO sub x, HO sub y PtO sub z, Pt-CO, and SnHCO3. Therefore a preliminary investigation was conducted to determine what might be learned about this particular catalyst by transmission FTIR. The main advantage of FTIR for this work is that the catalyst can be examined under conditions similar to the actual catalytic conditions. This can be of critical importance since some surface species may exist only when the reaction gases are present. Another advantage of the infrared approach is that since vibrations are probed, subtle chemical details may be obtained. The main disadvantage of this approach is that FTIR is not nearly as sensitive as the Ultra High Vacuum (UHV) surface analytical techniques such as Auger, Electron Spectroscopy for Chemical Analysis (ESCA), Electron Energy Loss Spectroscopy (EELS), etc. Another problem is that the assignment of the observed infrared bands may be difficult.

Keiser, Joseph T.↗

Impact fracture experiments simulating interstellar grain-grain collisions

Oxide and silicate grains condensing during the early phases of the formation of the solar system or in the outflow of stars are exposed to high partial pressures of the low-z elements H, C, N and O and their simple gaseous compounds. Though refractory minerals are nominally anhydrous and non-carbonate, if they crystallize in the presence of H2O, N2 and CO or CO2 gases, they dissolve traces of the gaseous components. The question arises: How does the presence of dissolved gases or gas components manifest itself when grain-grain collisions occur. What are the gases emitted when grains are shattered during a collision event. Researchers report on fracture experiments in ultrahigh vacuum (UHV, approximately less than 10 to the -8th power mbar) designed to measure (by means of a quadrupole mass spectrometer, QMS, with microns to ms time resolution) the emission of gases and vapors during and after impact (up to 1.5 sec). Two terrestrial materials were chosen which represent structural and compositional extremes: olivine (San Carlos, AZ), a densely packed Mg-Fe(2+) silicate from the upper mantle, available as 6 to 12 mm single crystals, and obsidian (Oregon), a structurally open, alkaline-SiO2-rich volcanic glass. In the olivine crystals OH- groups have been identified spectroscopically, as well as H2 molecules. Obsidian is a water-rich glass containing OH- besides H2O molecules. Olivine from the mantle often contains CO2, either as CO2-rich fluid in fluid inclusions or structurally dissolved or both. By analogy to synthetic glasses CO2 in the obsidian may be present in form of CO2 molecules in voids of molecular dimensions, or as carbonate anions, CO3(2-). No organic molecules have been detected spectroscopically in either material. Results indicate that refractory oxide/silicates which contain dissolved traces of the H2O and CO/CO2 components but no spectroscopically detectable traces of organics may release complex H-C-O (possibly H-C-N-O) molecules upon fracture, plus metal vapor. This points: (1) at complex reaction mechanisms between dissolved H2O, CO/CO2 (and N2) components within the mineral structure or during fracture, and (2) at the possibility that similar emission processes occur following grain-grain collisions in interstellar dust clouds.

Freund, Friedemann↗

TEMPUS: First results

The electromagnetic levitation facility, TEMPUS, developed by Dornier is designed to operate under microgravity conditions. Compared to terrestrial levitation, microgravity offers the possibility to melt and undercool in ultra high vacuum, thereby, providing an ultra clean environment. The technical concept of the TEMPUS facility was tested on two KC 135 flights and in the Texus 22 mission. Preparative investigations concerning the coil system and the heating and positioning efficiencies were carried out in the TEMPUS laboratory version. Furthermore, temperature-time profiles were determined under various boundary conditions. As a consequence of processing liquid metals under UHV, correct temperature measurement arises as the most critical problem. Experiences with experiments in the TEMPUS laboratory module show that due to the evaporation losses of the sample, the transmission of the CaF2 shielding windows changes drastically during the processing time. The investigation of the effect of contamination on pyrometry and the development of alternative evaporation shielding methods were initiated. During the second KC 135 flight, it was possible to heat up and melt an FeNi sample under He atmosphere. Oscillations of the molten sample, which were excited by switching out the magnetic heating field, could be detected and afterwards analyzed. From the frequency of these oscillations the surface tension of the sample material could be derived. The measurement of the surface tension and viscosity of an undercooled metal is proposed for TEMPUS on IML-2. This document is presented in view graph form.

Neuhaus, P.↗

Versatile, low-cost, computer-controlled, sample positioning system for vacuum applications

A versatile, low-cost, easy to implement, microprocessor-based motorized positioning system (MPS) suitable for accurate sample manipulation in a Second Ion Mass Spectrometry (SIMS) system, and for other ultra-high vacuum (UHV) applications was designed and built at NASA LeRC. The system can be operated manually or under computer control. In the latter case, local, as well as remote operation is possible via the IEEE-488 bus. The position of the sample can be controlled in three linear orthogonal and one angular coordinates.

Vargas-Aburto, Carlos↗

Scanning tunneling microscopy studies of diamond films and optoelectronic materials

In this report, we report on progress achieved from 12/1/92 to 10/1/93 under the grant entitled 'Scanning Tunneling Microscopy Studies of Diamond Films and Optoelectronic Materials'. We have set-up a chemical vapor deposition (CVD) diamond film growth system and a Raman spectroscopy system to study the nucleation and growth of diamond films with atomic resolution using scanning tunneling microscopy (STM). A unique feature of the diamond film growth system is that diamond films can be transferred directly to the ultrahigh vacuum (UHV) chamber of a scanning tunneling microscope without contaminating the films by exposure to air. The University of North Texas (UNT) provided $20,000 this year as matching funds for the NASA grant to purchase the diamond growth system. In addition, UNT provided a Coherent Innova 90S Argon ion laser, a Spex 1404 double spectrometer, and a Newport optical table costing $90,000 to set-up the Raman spectroscopy system. The CVD diamond growth system and Raman spectroscopy system will be used to grow and characterize diamond films with atomic resolution using STM as described in our proposal. One full-time graduate student and one full-time undergraduate student are supported under this grant. In addition, several graduate and undergraduate students were supported during the summer to assist in setting-up the diamond growth and Raman spectroscopy systems. We have obtained research results concerning STM of the structural and electronic properties of CVD grown diamond films, and STM and scanning tunneling spectroscopy of carbon nanotubes. In collaboration with the transmission electron microscopy (TEM) group at UNT, we have also obtained results concerning the optoelectronic material siloxene. These results were published in refereed scientific journals, submitted for publication, and presented as invited and contributed talks at scientific conferences.

Perez, Jose M.↗

Electron spectroscopy analysis

The Surface Science Laboratories at the University of Alabama in Huntsville (UAH) are equipped with x-ray photoelectron spectroscopy (XPS or ESCA) and Auger electron spectroscopy (AES) facilities. These techniques provide information from the uppermost atomic layers of a sample, and are thus truly surface sensitive. XPS provides both elemental and chemical state information without restriction on the type of material that can be analyzed. The sample is placed into an ultra high vacuum (UHV) chamber and irradiated with x-rays which cause the ejection of photoelectrons from the sample surface. Since x-rays do not normally cause charging problems or beam damage, XPS is applicable to a wide range of samples including metals, polymers, catalysts, and fibers. AES uses a beam of high energy electrons as a surface probe. Following electronic rearrangements within excited atoms by this probe, Auger electrons characteristic of each element present are emitted from the sample. The main advantage of electron induced AES is that the electron beam can be focused down to a small diameter and localized analysis can be carried out. On the rastering of this beam synchronously with a video display using established scanning electron microscopy techniques, physical images and chemical distribution maps of the surface can be produced. Thus very small features, such as electronic circuit elements or corrosion pits in metals, can be investigated. Facilities are available on both XPS and AES instruments for depth-profiling of materials, using a beam of argon ions to sputter away consecutive layers of material to reveal sub-surface (and even semi-bulk) analyses.