Water recovery by catalytic treatment of urine vapor

The objective of this investigation was to demonstrate the feasibility of water recovery on a man-rated scale by the catalytic processing of untreated urine vapor. For this purpose, two catalytic systems, one capable of processing an air stream containing low urine vapor concentrations and another to process streams with high urine vapor concentrations, were designed, constructed, and tested to establish the quality of the recovered water.

Budininkas, P.↗

Development Status of the International Space Station Urine Processor Assembly

NASA, Marshall Space Flight Center (MSFC) is developing a Urine Processor Assembly (UPA) for the International Space Station (ISS). The UPA uses Vapor Compression Distillation (VCD) technology to reclaim water from pre-treated urine. This water is further processed by the Water Processor Assembly (WPA) to potable quality standards for use on the ISS. NASA has developed this technology over the last 25-30 years. Over this history, many technical issues were solved with thousands of hours of ground testing that demonstrate the ability of the UPA technology to reclaim water from urine. In recent years, NASA MSFC has been responsible for taking the UPA technology to "flight design" maturity. This paper will give a brief overview of the UPA design and a status of the major design and development efforts completed recently to mature the UPA to a flight level.

Holder, Donald W.↗

Development of Urine Receptacle Assembly for the Crew Exploration Vehicle

The Urine Receptacle Assembly (URA) initially was developed for Apollo as a primary means of urine collection. The aluminum housing with stainless steel honeycomb insert provided all male crewmembers with a non-invasive means of micturating into a urine capturing device and then venting to space. The performance of the URA was a substantial improvement over previous devices but its performance was not well understood. The Crew Exploration Vehicle (CEV) program is exploring the URA as a contingency liquid waste management system for the vehicle. URA improvements are required to meet CEV requirements, including: consumables minimization, flow performance, acceptable hygiene standards, crew comfort, and female crewmember capability. This paper presents the results of a historical review of URA performance during the Apollo program, recent URA performance tests on the reduced gravity aircraft flight under varying flow conditions, and a proposed development plan for the URA to meet CEV needs.

Cibuzar, Branelle Rae↗

Evaluation of Technologies to Prevent Precipitation During Water Recovery from Urine

The International Space Station (ISS) Urine Processor Assembly (UPA) experienced a hardware failure in the Distillation Assembly (DA) in October 2010. Initially the UPA was operated to recover 85% of the water from urine through distillation, concentrating the contaminants in the remaining urine. The DA failed due to precipitation of calcium sulfate (gypsum) which caused a loss of UPA function. The ISS UPA operations have been modified to only recover 70% of the water minimizing gypsum precipitation risk but substantially increasing water resupply needs. This paper describes the feasibility assessment of several technologies (ion exchange, chelating agents, threshold inhibitors, and Lorentz devices) to prevent gypsum precipitation. The feasibility assessment includes the development of assessment methods, chemical modeling, bench top testing, and validation testing in a flight-like ground UPA unit. Ion exchange technology has been successfully demonstrated and has been recommended for further development. The incorporation of the selected technology will enable water recovery to be increased from 70% back to the original 85% and improve the ISS water balance.

Broyan, James L., Jr.↗

Temporary Urine and Brine Stowage System (TUBSS) Development

International Space Station (ISS) crew liquid human waste is treated with chromic and sulfuric acids to maintain stability prior to processing to recover water. This pre-treated urine (PTU) and its processed by-product, brine, are highly toxic fluids that require special containment for on-orbit stowage. The temporary urine and brine stowage syste m (TUBSS) is an assembly used to store and transfer pre-treated urine (PTU) and brine for processing or disposal at a later date. This paper describes the development of the TUBSS, including design for two-fault tolerance and materials selection to maintain a soft, collapsible container. In addition, this paper will provide results of testing as well as lessons learned from the project, culminating in the successful launch of the hardware.

Dries, Kevin↗

Ion Exchange Technology Development in Support of the Urine Processor Assembly Precipitation Prevention Project for the International Space Station

In support of the Urine Processor Assembly Precipitation Prevention Project (UPA PPP), multiple technologies were explored to prevent CaSO4 dot 2H2O (gypsum) precipitation during the on-orbit distillation process. Gypsum precipitation currently limits the water recovery rate onboard the International Space Station (ISS) to 70% versus the planned 85% target water recovery rate. Due to its advanced performance in removing calcium cations in pretreated augmented urine (PTAU), ion exchange was selected as one of the technologies for further development by the PPP team. A total of 12 ion exchange resins were evaluated in various equilibrium and dynamic column tests with solutions of dissolved gypsum, urine ersatz, PTAU, and PTAU brine at 85% water recovery. While initial evaluations indicated that the Purolite SST60 resin had the highest calcium capacity in PTAU (0.30 meq/mL average), later tests showed that the Dowex G26 and Amberlite FPC12H resins had the highest capacity (0.5 meq/mL average). Further dynamic column testing proved that G26 performance is +/- 10% of that value at flow rates of 0.45 and 0.79 Lph under continuous flow, and 10.45 Lph under pulsed flow. Testing at the Marshall Spaceflight Center (MSFC) integrates the ion exchange technology with a UPA ground article under flight-like pulsed flow conditions with PTAU. To date, no gypsum precipitation has taken place in any of the initial evaluations.

Mitchell, Julie L.↗

Ion Exchange Technology Development in Support of the Urine Processor Assembly Precipitation Prevention Project for the International Space Station

In support of the Urine Processor Assembly Precipitation Prevention Project (UPA PPP), multiple technologies were explored to prevent CaSO4 2H2O (gypsum) precipitation during the on-orbit distillation process. Gypsum precipitation currently limits the water recovery rate onboard the International Space Station (ISS) to 70% versus the planned 85% target water recovery rate. Due to its ability to remove calcium cations in pretreated augmented urine (PTAU), ion exchange was selected as one of the technologies for further development by the PPP team. A total of 13 ion exchange resins were evaluated in various equilibrium and dynamic column tests with solutions of dissolved gypsum, urine ersatz, PTAU, and PTAU brine at 85% water recovery. While initial evaluations indicated that the Purolite SST60 resin had the highest calcium capacity in PTAU (0.30 meq/mL average), later tests showed that the Dowex G26 and Amberlite FPC12H resins had the highest capacity (0.5 meq/mL average). Testing at the Marshall Spaceflight Center (MSFC) integrates the ion exchange technology with a UPA ground article under flight-like pulsed flow conditions with PTAU. To date, no gypsum precipitation has taken place in any of the initial evaluations.

Mitchell, Julie L.↗

A Population Pharmacokinetic Model for Disposition in Plasma, Saliva and Urine of Scopolamine after Intranasal Administration to Healthy Human Subjects

An intranasal gel formulation of scopolamine (INSCOP) was developed for the treatment of Space Motion Sickness. The bioavailability and pharmacokinetics (PK) were evaluated under the Food and Drug Administration guidelines for clinical trials with an Investigative New Drug (IND) protocol. The aim of this project was to develop a PK model that can predict the relationship between plasma, saliva and urinary scopolamine concentrations using data collected from the IND clinical trials with INSCOP. Methods: Twelve healthy human subjects were administered three dose levels (0.1, 0.2 and 0.4 mg) of INSCOP. Serial blood, saliva and urine samples were collected between 5 min and 24 h after dosing and scopolamine concentrations were measured by using a validated LC‐MS‐MS assay. Pharmacokinetic Compartmental models, using actual dosing and sampling times, were built using Phoenix (version 1.2). Model selection was based on the likelihood ratio test on the difference of criteria (‐2LL) and comparison of the quality of fit plots. Results: The best structural model for INSCOP (minimal ‐2LL= 502.8) was established. It consisted of one compartment each for plasma, saliva and urine, respectively, which were connected with linear transport processes except the nonlinear PK process from plasma to saliva compartment. The best‐fit estimates of PK parameters from individual PK compartmental analysis and Population PK model analysis were shown in Tables 1 and 2, respectively. Conclusion: A population PK model that could predict population and individual PK of scopolamine in plasma, saliva and urine after dosing was developed and validated. Incorporating a non‐linear transfer from plasma to saliva compartments resulted in a significantly improved model fitting. The model could be used to predict scopolamine plasma concentrations from salivary and urinary drug levels, allowing non‐invasive therapeutic monitoring of scopolamine in space and other remote environments.

Wu, L.↗

Urine Pretreatment History and Perspective in NASA Human Spaceflight

Urine pretreatment is a technology that may seem to have small mass impacts in future spaceflight missions, but can have significant impacts on reliability, life, and performance of the rest of the wastewater management and recovery systems. NASA has experience with several different urine pretreatment systems, including those flow on the space shuttle, evaluated for NASA waste collection systems or used in Russian commodes on ISS, or developed by NASA or industry as alternatives. Each has had unique requirements for shelf life, operational life, and the life or conditions of the stored, treated urine. Each was evaluated under different test conditions depending on mission, and depending on testing experience developed over NASA's history. Those that were flown led to further lessons learned about hardware compatibility and control. As NASA looks forward to human spaceflight missions beyond low Earth orbit, these techniques need to be evaluated in new light. Based on published design reference missions, candidate requirements can be derived for future systems. Initial comparisons between these requirements and previous performance or test results can be performed. In many cases these comparisons reveal data gaps. Successful previous performance is not enough to address current needs.

Anderson, Molly↗

Odor Control Test Report of the Urine Containment Bag (UCB) for Orion Utilization

The purpose of this report is to summarize the conclusions for the odor control test of the Urine Containment Bag (UCB), P/N SDD46107234-306 in an environment simulating a space craft capsule. JSC 65891, Odor Control Test Plan of the Urine Containment Bag (UCB) for Orion Utilization, documents the test plan. The details of the test set-up and data reduction are detailed in the WSTF test report for this test WSTF #10-44500, Odor Control Test Plan of the Urine Containment Bag (UCB) for Orion Utilization,. This document outlines the project conclusions and forward plans with regard to trash containment for Constellation.

Casper, Stephanie↗

An improved method for uranium separation from urine for rapid bioassay by inductively coupled plasma mass spectrometry

Bioassay monitoring is an important capability for any facility that works with significant amounts of radioactive material. The speed at which these analyses can be made is critical in the event of a potential exposure. Here, we present a new method that facilitates the rapid separation of uranium from a urine matrix for assay and isotopic determination by inductively coupled plasma mass spectrometry. This method is validated with archived urine samples that were previously analyzed using established, more time consuming methods. The sources of uncertainty for uranium assay and isotopic measurements are modelled using the Monte Carlo method to better understand the precision and accuracy of this method at the limit of quantification.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Upgrades to the International Space Station Urine Processor Assembly

Since November 2008, the ISS Urine Processor Assembly (UPA) has successfully generated distillate from crew urine. Several rounds of modifications and upgrades have also been implemented to improve overall system performance throughout the years. The Distillation Assembly (DA) is the latest upgraded unit available, installed in September 2020. This unit has shown immediate performance improvements and redesign success. Most significant upgrades have been a redesigned drive train to eliminate belt slips, improved sealing to reduce leak paths and improve wear, and a redesigned liquid level sensor. The Purge Pump and Separator Assembly (PPSA) technology demonstration is the next available upgraded unit and has finished ground assembly and testing and is targeted for ISS delivery within the coming year. Most recent ground studies have identified areas to focus future UPA upgrade considerations with exploration missions in mind, specifically for better fault detection and isolations approaches as well as potential hardware redesigns to facilitate successful dormancy operations.

Urine Processor Assembly↗

Urine sampling and collection system

This specification defines the performance and design requirements for the urine sampling and collection system engineering model and establishes requirements for its design, development, and test. The model shall provide conceptual verification of a system applicable to manned space flight which will automatically provide for collection, volume sensing, and sampling of urine.

Fogal, G. L.↗

A urine volume measurement system

An improved urine volume measurement system for use in the unusual environment of manned space flight is reported. The system utilizes a low time-constant thermal flowmeter. The time integral of the transient response of the flowmeter gives the urine volume during a void as it occurs. In addition, the two phase flows through the flowmeter present no problem. Developments of the thermal flowmeter and a verification of the predicted performance characteristics are summarized.

Poppendiek, H. F.↗

Microchemical urinalysis. IX - Determination of hydroxyproline in urine.

A simplified procedure is described for the determination of hydroxyproline in human or monkey urine. In this procedure 1 ml of urine is subjected in succession to hydrolysis, oxidation, extraction, and color development. During these steps impurities and interfering substances are eliminated, thus resulting in a chromophore due to hydroxyproline alone.

Grunbaum, B. W.↗

The determination of ethanol in blood and urine by mass fragmentography

A mass fragmentographic technique for a rapid, specific and sensitive determination of ethanol in blood and urine is described. A Varian gas chromatograph coupled through an all-glass membrane separator to a Finnigan quadripole mass spectrometer and interfaced to a computer system is used for ethanol determination in blood and urine samples. A procedure for plotting calibration curves for ethanol quantitation is also described. Quantitation is achieved by plotting the peak area ratios of undeuterated-to-deuterated ethanol fragment ions against the amount of ethanol added. Representative results obtained by this technique are included.

Pereira, W. E.↗

Effect of 14 days of bed rest on urine metabolite excretion and plasma enzyme levels

After 1 week of ambulatory base-line measurement, a group of 8 men 19-26 years of age remained continuously recumbent for 14 days. Studies were continued for 1 week following the prolonged recumbency. Urine excretion rates for a number of constituents were determined 2 days before bed rest, on day 14 of bed rest, and day 6 after bed rest. Blood plasma samples were also obtained at these times, and analyzed for several enzymes. On day 14 of bed rest significant increases were observed in urine excretion of total osmotically-active substances, magnesium, calcium, phosphate, creatinine, hydroxyproline, and 17-OH corticosteroids. A decrease occurred in urinary glucose excretion. Plasma levels of alkaline phosphatase and LDH-3 were depressed, while plasma GPT was elevated. Many of these changes persisted on day 6 after bed rest, and are interpreted as concomitants of the disuse atrophy of the musculoskeletal system that characterizes prolonged bed rest and weightlessness.

Pace, N.↗

Automated biowaste sampling system urine subsystem operating model, part 1

The urine subsystem automatically provides for the collection, volume sensing, and sampling of urine from six subjects during space flight. Verification of the subsystem design was a primary objective of the current effort which was accomplished thru the detail design, fabrication, and verification testing of an operating model of the subsystem.