Search NASA⌕ Search

SEARCH · Search NASA

Results for “Uncertainty Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Strain Gauge Balance Uncertainty Analysis at NASA Langley: A Technical Review

This paper describes a method to determine the uncertainties of measured forces and moments from multi-component force balances used in wind tunnel tests. A multivariate regression technique is first employed to estimate the uncertainties of the six balance sensitivities and 156 interaction coefficients derived from established balance calibration procedures. These uncertainties are then employed to calculate the uncertainties of force-moment values computed from observed balance output readings obtained during tests. Confidence and prediction intervals are obtained for each computed force and moment as functions of the actual measurands. Techniques are discussed for separate estimation of balance bias and precision uncertainties.

John S Tripp↗

Uncertainty Analysis in Space Radiation Protection

Space radiation is comprised of high energy and charge (HZE) nuclei, protons, and secondary radiation including neutrons. The uncertainties in estimating the health risks from galactic cosmic rays (GCR) are a major limitation to the length of space missions, the evaluation of potential risk mitigation approaches, and application of the As Low As Reasonably Achievable (ALARA) principle. For long duration space missio ns, risks may approach radiation exposure limits, therefore the uncertainties in risk projections become a major safety concern and methodologies used for ground-based works are not deemed to be sufficient. NASA limits astronaut exposures to a 3% risk of exposure induced death (REID) and protects against uncertainties in risks projections using an assessment of 95% confidence intervals in the projection model. We discuss NASA s approach to space radiation uncertainty assessments and applications for the International Space Station (ISS) program and design studies of future missions to Mars and other destinations. Several features of NASA s approach will be discussed. Radiation quality descriptions are based on the properties of radiation tracks rather than LET with probability distribution functions (PDF) for uncertainties derived from radiobiology experiments at particle accelerators. The application of age and gender specific models for individual astronauts is described. Because more than 90% of astronauts are never-smokers, an alternative risk calculation for never-smokers is used and will be compared to estimates for an average U.S. population. Because of the high energies of the GCR limits the benefits of shielding and the limited role expected for pharmaceutical countermeasures, uncertainty reduction continues to be the optimal approach to improve radiation safety for space missions.

Cucinotta, Francis A.↗

Interpolation Method Needed for Numerical Uncertainty Analysis of Computational Fluid Dynamics

Using Computational Fluid Dynamics (CFD) to predict a flow field is an approximation to the exact problem and uncertainties exist. There is a method to approximate the errors in CFD via Richardson's Extrapolation. This method is based off of progressive grid refinement. To estimate the errors in an unstructured grid, the analyst must interpolate between at least three grids. This paper describes a study to find an appropriate interpolation scheme that can be used in Richardson's extrapolation or other uncertainty method to approximate errors. Nomenclature

CFD↗

Methods for Probabilistic Uncertainty Analysis and Bayesian Analysis with Examples of Statistically Analyzing Data to Revise MMOD Risk Estimates and Compare Models

Probabilistic methods are presented for characterizing and quantifying uncertainties in models and model predictions. Techniques are given for constructing specific uncertainty distributions based on available information. Alternative techniques are given for propagating uncertainties in model inputs to obtain the uncertainty in the model result or prediction. Bayesian techniques are also described for utilizing data and information to update and revise model results and predictions. The focus is on applications with numerous specific examples given. The use of data to revise Micrometeoroid and Orbital Debris (MMOD) risk prediction models are among the examples given.

Risk↗

Computational Fluid Dynamics Uncertainty Analysis for Payload Fairing Spacecraft Environmental Control Systems

Spacecraft components may be damaged due to airflow produced by Environmental Control Systems (ECS). There are uncertainties and errors associated with using Computational Fluid Dynamics (CFD) to predict the flow field around a spacecraft from the ECS System. This paper describes an approach to estimate the uncertainty in using CFD to predict the airflow speeds around an encapsulated spacecraft.

Computational↗

Uncertainty Analysis on Heat Transfer Correlations for RP-1 Fuel in Copper Tubing

NASA is studying kerosene (RP-1) for application in Next Generation Launch Technology (NGLT). Accurate heat transfer correlations in narrow passages at high temperatures and pressures are needed. Hydrocarbon fuels, such as RP-1, produce carbon deposition (coke) along the inside of tube walls when heated to high temperatures. A series of tests to measure the heat transfer using RP-1 fuel and examine the coking were performed in NASA Glenn Research Center's Heated Tube Facility. The facility models regenerative cooling by flowing room temperature RP-1 through resistively heated copper tubing. A Regression analysis is performed on the data to determine the heat transfer correlation for Nusselt number as a function of Reynolds and Prandtl numbers. Each measurement and calculation is analyzed to identify sources of uncertainty, including RP-1 property variations. Monte Carlo simulation is used to determine how each uncertainty source propagates through the regression and an overall uncertainty in predicted heat transfer coefficient. The implications of these uncertainties on engine design and ways to minimize existing uncertainties are discussed.

Driscoll, E. A.↗

Uncertainty Analysis of Heat Transfer to Supercritical Hydrogen in Cooling Channels

Sound understanding of the cooling efficiency of supercritical hydrogen is crucial to the development of high pressure thrust chambers for regeneratively cooled LOX/LH2 rocket engines. This paper examines historical heat transfer correlations for supercritical hydrogen and the effects of uncertainties in hydrogen property data. It is shown that uncertainty due to property data alone can be as high as 10%. Previous heated tube experiments with supercritical hydrogen are summarized, and data from a number of heated tube experiments are analyzed to evaluate conditions for which the available correlations are valid.

Locke, Justin M.↗

Uncertainty Analysis of Decomposing Polyurethane Foam

Sensitivity/uncertainty analyses are necessary to determine where to allocate resources for improved predictions in support of our nation's nuclear safety mission. Yet, sensitivity/uncertainty analyses are not commonly performed on complex combustion models because the calculations are time consuming, CPU intensive, nontrivial exercises that can lead to deceptive results. To illustrate these ideas, a variety of sensitivity/uncertainty analyses were used to determine the uncertainty associated with thermal decomposition of polyurethane foam exposed to high radiative flux boundary conditions. The polyurethane used in this study is a rigid closed-cell foam used as an encapsulant. Related polyurethane binders such as Estane are used in many energetic materials of interest to the JANNAF community. The complex, finite element foam decomposition model used in this study has 25 input parameters that include chemistry, polymer structure, and thermophysical properties. The response variable was selected as the steady-state decomposition front velocity calculated as the derivative of the decomposition front location versus time. An analytical mean value sensitivity/uncertainty (MV) analysis was used to determine the standard deviation by taking numerical derivatives of the response variable with respect to each of the 25 input parameters. Since the response variable is also a derivative, the standard deviation was essentially determined from a second derivative that was extremely sensitive to numerical noise. To minimize the numerical noise, 50-micrometer element dimensions and approximately 1-msec time steps were required to obtain stable uncertainty results. As an alternative method to determine the uncertainty and sensitivity in the decomposition front velocity, surrogate response surfaces were generated for use with a constrained Latin Hypercube Sampling (LHS) technique. Two surrogate response surfaces were investigated: 1) a linear surrogate response surface (LIN) and 2) a quadratic response surface (QUAD). The LHS techniques do not require derivatives of the response variable and are subsequently relatively insensitive to numerical noise. To compare the LIN and QUAD methods to the MV method, a direct LHS analysis (DLHS) was performed using the full grid and timestep resolved finite element model. The surrogate response models (LIN and QUAD) are shown to give acceptable values of the mean and standard deviation when compared to the fully converged DLHS model.

Hobbs, Michael L.↗

Detailed Uncertainty Analysis of the Ares I A106 Liftoff/Transition Database

The Ares I A106 Liftoff/Transition Force and Moment Aerodynamics Database describes the aerodynamics of the Ares I Crew Launch Vehicle (CLV) from the moment of liftoff through the transition from high to low total angles of attack at low subsonic Mach numbers. The database includes uncertainty estimates that were developed using a detailed uncertainty quantification procedure. The Ares I Aerodynamics Panel developed both the database and the uncertainties from wind tunnel test data acquired in the NASA Langley Research Center s 14- by 22-Foot Subsonic Wind Tunnel Test 591 using a 1.75 percent scale model of the Ares I and the tower assembly. The uncertainty modeling contains three primary uncertainty sources: experimental uncertainty, database modeling uncertainty, and database query interpolation uncertainty. The final database and uncertainty model represent a significant improvement in the quality of the aerodynamic predictions for this regime of flight over the estimates previously used by the Ares Project. The maximum possible aerodynamic force pushing the vehicle towards the launch tower assembly in a dispersed case using this database saw a 40 percent reduction from the worst-case scenario in previously released data for Ares I.

Hanke, Jeremy L.↗

Pre-launch Radiometric Calibration and Uncertainty Analysis of Landsat Thermal Infrared Sensor 2

The Thermal Infrared Sensor-2 that will be on-board Landsat 9 has undergone a pre-launch testing campaign to characterize its radiometric, spectral, and spatial performance and demonstrate compliance to its requirements. This work reviews key elements of the instrument-level radiometric testing using an SI traceable source to derive its uncertainties. Those arising from on-orbit calibration using the TIRS-2 on-board blackbody are also discussed. We use a Monte Carlo approach to propagate the uncertainties through a non-linear calibration equation and address both random and systematic uncertainty terms. Achieving the required performance demonstrates the instrument’s potential for enhancing our understanding of the Earth’s environment.

Landsat↗

Prelaunch Radiometric Calibration and Uncertainty Analysis of Landsat Thermal Infrared Sensor 2

The Thermal Infrared Sensor-2 (TIRS-2) that will be onboard Landsat 9 has undergone a prelaunch testing campaign to characterize its radiometric, spectral, and spatial performances and demonstrate compliance to its requirements. This work reviews the key elements of the instrument-level radiometric testing using an SI-traceable source to derive its uncertainties. Those arising from on-orbit calibration using the TIRS-2 onboard blackbody are also discussed. We use a Monte Carlo approach to propagate the uncertainties through a nonlinear calibration equation and address both random and systematic uncertainty terms. Achieving the required performance demonstrates the instrument's potential for enhancing our understanding of the Earth's environment.

Aaron Pearlman↗

Uncertainty Analysis of Coaxial Thermocouple Calorimeters Used in Arc Jets

Recent introduction of Coaxial Thermocouple type calorimeters into the NASA Ames arc jet facilities has inspired an analysis of 2D conduction effects internal to this type of calorimeter. Lateral conduction effects violate the 1D finite slab inverse analysis which is typically used to deduce the heat transfer to such calorimeters. The spherical shaped nose associated with most calorimeters (rather than flat) leads to a bias error that over-estimates the stagnation heating. Non-uniform heating on the face of spherically shaped calorimeters leads to conduction losses to the colder rim of the calorimeter which causes an underestimate of the stagnation heating. These two effects come into play at different times of the calorimeter's exposure to the arc jet, so they do not cancel. The spherical body effects come into play in the early stages of exposure, while the non-uniform heating effect becomes most severe at the later stages of exposure. The bias associated with spherical effects can be avoided by rewriting the 1D finite slab inverse analysis code to solve for 1D conduction in spherical coordinates. However, reducing the bias error associated non-uniform heating requires a somewhat ad hoc modification to the 1D finite element inverse analysis.

Isotherms↗

Uncertainty Analysis of the Pitch Damping Coefficient of Blunt Bodies, Measured from Magnetic Suspension Wind Tunnel Tests

Blunt body aerodynamics in re-entry conditions are characterized by oscillatory behavior that is often encapsulated by the pitch damping coefficient (Cmq). Magnetic Suspension Wind Tunnel (MSWT) testing with a Magnetic Suspension Balance System (MSBS) aims to improve blunt body wind tunnel testing by removing the sometimes unknown aerodynamic effects of traditional sting mounts, as well as generate more constrained outputs than vertical spin tunnel testing. Efforts to calculate the uncertainty of the pitch damping coefficient with a proposed Earth Entry Vehicle (EEV) capsule model have been made by fitting an analytic prediction of the attitude time history to video data of a free-to-oscillate MSBS test.

Magnetic suspension, dynamic stability, uncertaint↗

Efficient Parametric Uncertainty Analysis of an Earth Entry Vehicle Concept Using Least Angle Regression

The objective of this work was to outline and apply an efficient and accurate parametric un-certainty propagation approach to the analysis of convective heating on an Earth entry vehicle concept. The described approach was based on Least Angle Regression used to solve a sparse and underdetermined linear system in the point-collocation non-intrusive polynomial chaos surrogate method. This approach involved an iterative process to computing the non-zero terms of the underlying polynomial chaos model using only enough samples to converge uncertainty interval predictions and Sobol index values based global nonlinear sensitivity estimates. The Earth entry vehicle was analyzed at three points along a representative trajectory for a Mars return mission. 329 sources of uncertainty were identified in the computational fluid dynamics model used to predict the forebody convective heating. These included uncertainty in flow field chemical rates, collision integrals, heats of formation, surface finite rate char model reaction rates, wall roughness height, and the turbulent Schmidt number. Results from this study showed that convective heating uncertainty as high as 50% of the nominal was predicted with only about 50 evaluations of the computational model. This was far fewer than would be required for a sampling-based approach or a full basis polynomial chaos model, which would have required over 50,000 samples. Additionally, results showed that over 90% of the total convective heating uncertainty was due to uncertainty in the N2catalytic rate on the surface, while the remainder of the uncertainty was attributed to the turbulent Schmidt number and the wall roughness uncertainties.

Thomas K West IV↗

Micro-Pulse Lidar Signals: Uncertainty Analysis

Micro-pulse lidar (MPL) systems are small, autonomous, eye-safe lidars used for continuous observations of the vertical distribution of cloud and aerosol layers. Since the construction of the first MPL in 1993, procedures have been developed to correct for various instrument effects present in MPL signals. The primary instrument effects include afterpulse, laser-detector cross-talk, and overlap, poor near-range (less than 6 km) focusing. The accurate correction of both afterpulse and overlap effects are required to study both clouds and aerosols. Furthermore, the outgoing energy of the laser pulses and the statistical uncertainty of the MPL detector must also be correctly determined in order to assess the accuracy of MPL observations. The uncertainties associated with the afterpulse, overlap, pulse energy, detector noise, and all remaining quantities affecting measured MPL signals, are determined in this study. The uncertainties are propagated through the entire MPL correction process to give a net uncertainty on the final corrected MPL signal. The results show that in the near range, the overlap uncertainty dominates. At altitudes above the overlap region, the dominant source of uncertainty is caused by uncertainty in the pulse energy. However, if the laser energy is low, then during mid-day, high solar background levels can significantly reduce the signal-to-noise of the detector. In such a case, the statistical uncertainty of the detector count rate becomes dominant at altitudes above the overlap region.

Welton, Ellsworth J.↗

Uncertainty Analysis of Experimental Discharge Coefficients in Additively Manufactured Liquid Injector Elements

Screening of two additively manufactured liquid injector designs was conducted in the UAH high pressure spray facility. Four variants of each geometry with slightly different dimensions were obtained from eleven separate commercial additive manufacturing services. The devices were manufactured from Inconel 625 using the selective laser melting (SLM) powder bed process. The devices were cold flowed with water over a range of relevant pressure drops (75 psi to 1500 psi) to produce water flow rates from 0.037 to 1.75 lbm/s into ambient back pressure. Discharge coefficients determined from the testing along with the associated uncertainties provide insight into characteristic flow performance variabilities that can be expected from the SLM process for similar geometries.

Venters, James P.↗