Search NASA⌕ Search

SEARCH · Search NASA

Results for “Utility-Scale Energy Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Beginner's Guide to Understanding Power System Model Results for Long-Term Resource Plans

This guide was developed to improve decision-making in the electricity planning process by strengthening dialogue between electricity system planners and stakeholders throughout the process. This document was created for anyone who is first getting exposed to scenario results from power system planning models, or for those who are beginning to interact with power system modelers. It does not assume any experience with power system modeling, or familiarity with electricity planning concepts. This guide can be helpful to a wide range of people, including but not limited to state utility commissioners and commission staff, state energy offices, and intervenors in the planning process. It is targeted to those who are evaluating or reviewing model results presented by a utility, which typically span utility-scale generation and storage (and associated transmission) assets. This guide is designed to provide enough background and guidance that stakeholders can formulate and ask questions to evaluate model results through a deeper understanding of the key assumptions, data, and methods that drive decision outcomes. The ultimate purpose of this work is to increase transparency in the electricity planning process by enabling stakeholders to better engage and evaluate model results. A follow-on guide will provide a deeper dive into emerging topics, which are expected to become more prominent in the electricity planning process, but whose methods and approaches are still being refined.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Multi-Sensor Approach for Measuring Bird and Bat Collisions with Offshore Wind Turbines (Final Technical Report)

Collision of birds and bats with wind turbines is a conservation concern for both land-based and offshore wind projects. The fatality rates of birds and bats at land-based turbines are well documented. The measurement strategies on land focus on finding carcasses following collision, estimating the number of carcasses missed through searcher efficiency, carcass persistence trials and carcass fall distributions, and modeling statistically robust fatality rates. Few technologies have been developed to monitor offshore bird and bat collisions, and many that have been developed focused on detecting collisions with large birds. The few studies that have attempted to document collisions at offshore turbines do not account for smaller bodied animals or for collisions that might be missed, which prevents the calculation of statistically robust fatality rates. The overall goal of this report, A Multi-Sensor Approach for Measuring Bird and Bat Collisions with Offshore Wind Turbines (Project), was to develop an effective multi-sensor system for quantifying bird and bat collision rates, specifically for offshore wind facilities. The Project goal and resulting automated collision detection system was achieved through two major technological advancements: 1) refining The Netherlands Organisation for Applied Scientific Research’s (TNO’s) existing WT-Bird® vibration sensing system, that had successfully detected large bird collisions during daytime, to allow for improved detection of smaller birds and bats during both daytime and nighttime hours and 2) improving image processing systems and developing and integrating machine learning algorithms to automatically detect and classify small and large bird and bat collisions with offshore turbines. This final technical report (FTR) summarizes Methods , Results , Conclusions , and Lessons Learned during each of the five Tasks identified for this research and development effort. This FTR includes summaries of the following: Task 1. Initial Engineering Tests to Improve WT-Bird® Task 2. Installation of WT‐Bird® on a Utility-scale Turbine at the National Wind Technology Center – National Renewable Energy Laboratory Task 3. Field Tests and Refinement of the Object Detection System Task 4. Validation of WT-Bird® on a Land-based Turbine Task 5. Preparation for the Implementation of WT-Bird® on an Offshore Turbine. This research and development effort documented successful improvement of the WT Bird® collision detection system to detect small birds and bats, and WT-Bird® is the first collision detection system to validate results compared to land-based post-construction monitoring. The collision trials provide estimates of missed targets that can be used to estimate fatality rates, a significant improvement relative to other offshore collision monitoring systems. Advances were made in developing an edge-processing solution to reduce data storage requirements, which is important if the system is deployed for long periods of time at offshore turbines. The improved WT-Bird® system also provides an important option for wind operators on land or offshore who need to document specific details about when collisions occur, particularly efforts to further research on bat impact minimization, or when standard fatality searches are impractical (e.g. offshore) or inadequate (e.g. challenging locations on land).

17 WIND ENERGY↗

Operations, maintenance, and cost considerations for PV+Storage in the United States

Battery storage systems are increasingly being installed at photovoltaic (PV) sites to address supply-demand balancing needs. Although there is some understanding of costs associated with PV operations and maintenance (O&M), costs associated with emerging technologies such as PV plus storage lack details about the specific systems and/or activities that contribute to the cost values. This study aims to address this gap by exploring the specific factors and drivers contributing to utility-scale PV plus storage systems (UPVS) O&M activities costs, including how technology selection, data collection, and related and ongoing challenges. Specifically, we used semi-structured interviews and questionnaires to collect information and insights from utility-scale owners and operators. Data was collected from 14 semi-structured interviews and questionnaires representing 51.1 MW with 64.1 MWh of installed battery storage capacity within the United States (U.S.). Differences in degradation rate, expected life cycle, and capital costs are observed across different storage technologies. Most O&M activities at UPVS related to correcting under-performance. Fires and venting issues are leading safety concerns, and owner operators have installed additional systems to mitigate these issues. There are ongoing O&M challenges due the lack of storage-specific performance metrics as well as poor vendor reliability and parts availability. Insights from this work will improve our understanding of O&M consideration at PV plus storage sites.

14 SOLAR ENERGY↗

Tracking the Sun: Pricing and Design Trends for Distributed Photovoltaic Systems in the United States, 2024 Edition [Slides]

Berkeley Lab’s annual Tracking the Sun report describes trends among grid-connected, distributed solar photovoltaic (PV) and paired PV+storage systems in the United States. For the purpose of this report, distributed solar includes residential systems, roof-mounted non-residential systems, and ground-mounted systems up to 5 MW-AC. Ground-mounted systems larger than 5 MW-AC are covered in Berkeley Lab’s companion annual report, Utility-Scale Solar. The latest edition of the report is based on 3.7 million systems installed through year-end 2023, representing close to 80% of systems installed to date. The report describes and discusses key trends related to: -Project characteristics, including system size, module efficiencies, roof-coverage ratios, prevalence of paired PV with storage, use of module-level power electronics, third-party ownership, mounting configurations, panel orientation, and customer segmentation -Median installed-price trends, both nationally and by state -Variability in pricing according to system size, state, installer, equipment type, and other factors, relying on both descriptive analysis and a multi-variate regression to estimate the effects of key pricing drivers for residential systems installed in 2023.

14 SOLAR ENERGY↗

Tracking the Sun: Pricing and Design Trends for Distributed Photovoltaic Systems in the United States (2023 Edition) [Slides]

Berkeley Lab’s annual Tracking the Sun report describes trends among grid-connected, distributed solar photovoltaic (PV) and paired PV+storage systems in the United States. For the purpose of this report, distributed solar includes residential systems, roof-mounted non-residential systems, and ground-mounted systems up to 5 MW-AC. Ground-mounted systems larger than 5 MW-AC are covered in Berkeley Lab’s companion annual report, Utility-Scale Solar. The latest edition of the report is based on 3.2 million systems installed through year-end 2022, representing more than 80% of systems installed to date. The report describes and discusses key trends related to: -Project characteristics, including system size, module efficiencies, prevalence of paired PV with storage, use of module-level power electronics, third-party ownership, mounting configurations, panel orientation, and non-residential customer segmentation ownership -Median installed-price trends, both nationally and by state -Variability in pricing according to system size, state, installer, equipment type, and other factors, relying on both descriptive and econometric analysis The report also includes a multi-variate regression analysis to estimate the effects of key pricing drivers for residential systems installed in 2022.

14 SOLAR ENERGY↗

An Educational Program on Concentrated Solar Power and Heliostats for Power Generation and Industrial Processes

The objective of this project was to design and implement a comprehensive educational and applied research program in Concentrated Solar Thermal Power (CSTP) and heliostat technologies at Northeastern University. In alignment with the U.S. Department of Energy's Heliostat Consortium (HelioCon) goals, the project aimed to expand student and public understanding of CSTP systems while simultaneously contributing to workforce development and the broader decarbonization strategy. A particular emphasis was placed on integrating hands-on student design projects and publicly disseminating educational content relevant to CSTP systems. The project addressed a critical gap in renewable energy education: CSTP and heliostats, despite their importance in utility-scale solar energy, are rarely included in standard mechanical engineering programs. This project established new pathways for students to engage with the topic through the creation of a 4-credit graduate/senior elective course, development of five industry-facing short courses, and the inclusion of CSTP-based capstone design projects. Over two academic years, 36 students across six senior design teams developed and tested technologies such as deformable heliostats, beacon-based tracking systems, and solar-powered pyrolizers for biomass-to-biochar conversion. Concurrently, 30 undergraduate and graduate students were enrolled in the new academic course centered around CSTP principles. To ensure the relevance and accessibility of the short course content, the project team engaged with industry professionals, technical policy stakeholders, and potential course participants through structured surveys and informal consultations. Feedback from 28 respondents guided the structure, length, and delivery format of the courses - resulting in a modular design broken into five workshops. The feedback emphasized the need for flexible, asynchronous delivery and practical case studies, particularly in areas such as heliostat control, thermal storage, and solar fuel production. This engagement helped align the courses with the evolving knowledge demands of the renewable energy workforce and ensured that participants from both technical and policy backgrounds could meaningfully benefit from the material. The research and educational activities advanced the understanding of heliostat control systems, optical performance under misalignment, and thermal system integration in solar-driven pyrolysis applications. Methods and designs explored in this project proved to be both technically effective and economically feasible at the lab scale. Prototypes were constructed using commercially available components and custom-fabricated elements, demonstrating that meaningful performance improvements can be achieved with modest material and fabrication costs, supporting the feasibility of student-led research in this field. The public benefit of this project is twofold. First, it cultivates a pipeline of engineers trained to be familiar with CSTP principles, an essential workforce need identified by the Department of Energy for achieving its 2030 cost and deployment targets. Second, it contributes openly accessible educational materials, course content, and experimental frameworks to the broader community, enabling other institutions to adopt or adapt similar programming. Through outreach activities, curriculum integration, and technical exposure, this project contributes to a more informed and capable renewable energy workforce while supporting innovation in heliostat and CSTP system design. A new technical report is being prepared to document the development of the course and its outcomes, with plans to publish it in the ASME Open Access Journal of Engineering to ensure global accessibility, free of cost.

14 SOLAR ENERGY↗

Integration of Hybrids into Wholesale Power Markets

With growing commercial activity around utility-scale hybrid storage projects in the Unites States, independent system operators (ISOs) and regional transmission organizations (RTOs) are faced with making decisions on how to represent such emerging technology resources in the market clearing software through the definition of hybrid resource participation models. System operators are facing increasing uncertainties around efficient and reliable ways to operate these resources given the ambiguity around their impacts, particularly when high levels of hybrid resources are present. This study aimed to evaluate and compare the performance implications of different hybrid resource participation models in a realistic wholesale electricity market setting with significant deployment of hybrid resources, and to provide the industry with metrics that quantify the advantages and disadvantages of different participation options using realistic electricity market simulations. The different participation models are compared in terms of the impact to reliability of the overall system, the ability of the market to access the full capabilities of hybrid resources as measured by the economic efficiency, and asset profitability.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Utility-Scale Solar, 2024 Edition: Empirical Trends in Deployment, Technology, Cost, Performance, PPA Pricing, and Value in the United States [Slides]

Berkeley Lab’s “Utility-Scale Solar, 2024 Edition” presents analysis of empirical plant-level data from the U.S. fleet of ground-mounted photovoltaic (PV), PV+battery, and concentrating solar-thermal power (CSP) plants with capacities exceeding 5 MWAC (PV plants of 5 MWAC or less, including residential rooftop systems, are covered separately in Berkeley Lab’s companion annual report, Tracking the Sun). Key findings from this year’s report include: -18.5 GWAC of new utility-scale PV capacity came online in 2023, bringing cumulative installed capacity to more than 80.2 GWAC across 47 states. Installed costs continued to fall in 2023. Relative to 2022, capacity-weighted averages decreased by 8% to -$\$1.43$/WAC (or $\$1.08$/WDC). Costs, based on a 7.1 GWAC sample of 76 plants completed in 2023, have fallen by 75% (averaging 10% annually) since 2010. Plant-level capacity factors vary widely, from 6% to 36% (on an AC basis), with a sample median of 24%. -Levelized cost of energy (LCOE) of new 2023 projects increased slightly to $\$46$/MWh prior to the application of tax credits but continued to fall to $\$31$/MWh when accounting for federal incentives. PPA prices have largely followed the decline in solar’s LCOE over time, but newly signed longer-term PPA prices have increased since 2021, to an average of $\$35$/MWh (levelized, in 2023 dollars). -Solar’s average energy and capacity value (i.e., ability to offset costs of other power generation sources) across the U.S. was $\$45$/MWh in 2023. Solar’s average market value was lowest in CAISO ($\$27$/MWh), the market with the greatest solar generation share, and highest in ERCOT ($\$67$/MWh). -Newer solar projects had greater market value in 2023 than their generation costs, yielding $\$1.1$ billion in benefits. Projects built in 2022 delivered on average $\$15$/MWh more market value than their costs in 2023. -Solar’s combined value from wholesale electricity markets, public health and climate damage reduction were greater than generation costs and incentives, yielding $\$13.7$ billion in net benefits in 2023. We estimate U.S. health benefits of $\$24$/MWh and reduced global climate damages of $\$101$/MWh. -Adding battery storage is one way to increase the value of solar. Deployment of 52 new PV+battery hybrid plants set a record with 5.3 GW installed in 2023. Our public data file tracks metadata and PPA prices from more than 100 PV+battery hybrid projects that are already online or that have secured offtake arrangements. -Looking ahead, a massive pipeline of at least 1,085 GW of solar capacity dominates the nation’s interconnection queues at the end of 2023. Nearly 571 GW, or 53%, of that total was paired with a battery – in CAISO it was a staggering 98%. Historically only 10% of the requested solar capacity is built. -For more information, and to explore related interactive data visualizations, go to utilityscalesolar.lbl.gov.

14 SOLAR ENERGY↗

Defining a compact dry cooler design to reduce LCOE contribution in a CSP facility

Concentrating solar power (CSP), when coupled with a supercritical carbon dioxide (sCO 2 ) power cycle and sensible heat storage, presents a renewable and clean alternative for utility-scale power generation. However, in order to be competitive in the current and future markets, CSP facilities must limit their levelized cost of electricity (LCOE) by minimizing capital costs and reducing operating costs over the lifetime of the plant. Targeting this goal, this study investigates the LCOE impact of the power cycle pre-cooler. This study considers a compact dry cooler with micro-channel technology on the CO 2 side and formed fin geometry on the air side, using directly-coupled centrifugal fans and a transition duct to improve air distribution across the fins as well as protect the fins from contaminants which may cause blockage, soiling, fouling, and damage. In an effort to better understand the dry cooler impact on LCOE, a sensitivity study was conducted using various combinations of end-to-end approach temperatures, air-side pressure drop values, CO 2 -side pressure drop values, fan types, cooler turndown control schemes, cooler module sizes, and design-point ambient temperatures. Furthemore, off-design cycle performance data was calculated for each dry cooler design using NPSS simulation software; cycle performance data were then input to System Advisor Model (SAM) along with the associated capital costs for LCOE prediction of a 100 MW system over a 30 year plant lifetime. Results of this study show the LCOE is most sensitive to air-side performance, followed by heat transfer effectiveness and capital cost. It was found that a power cycle with a mid- to high-performance dry cooler will produce the most competitive power-production costs. Designing at the extreme ends for approach temperature (or effectiveness), design-point ambient temperature, and compactness (footprint) produce higher LCOE values; mid-range values for these parameters balance performance, operating costs, and associated capital cost to optimize LCOE.

14 SOLAR ENERGY↗

Assessing the levelized cost of energy in South Korea

This study evaluates the levelized cost of energy (LCOE) for various energy technologies in the Republic of Korea (Korea) from 2023 to 2050, highlighting cost trajectories and potential crossovers among competing technologies. The analysis projects that, based on our set of assumptions, utility-scale photovoltaic systems achieve lower LCOEs than nuclear by 2030, while fixed offshore wind is expected to become cost-competitive with coal-fired generation around the same time. Floating offshore wind is projected to reach cost parity with coal in the late 2030s. Co-firing with natural gas and green hydrogen is identified as the highest-cost generation option due to high natural gas and green fuel costs and declining capacity utilization. This study further examines the potential for hybrid systems that integrate renewable energy with energy storage to serve as flexible, cost-effective, zero-emission alternatives to green hydrogen-based generation. Spatial LCOE assessments indicate that near-shore offshore wind sites may achieve lower costs despite modest capacity factors, contingent on site-specific factors such as grid integration and social acceptance. The findings indicate that renewable energy technologies are expected to experience continued cost declines, with solar photovoltaic becoming the most competitive energy source in Korea by 2030–2035. Incorporating social costs accelerates this shift from conventional alternatives.

Green hydrogen↗

The Potential and Cost of Carbon Dioxide Removal Using Direct Air Capture with Land-Based Wind and Utility-Scale Photovoltaics

The rapid deployment of direct air capture and storage (DACS) is critical for achieving emission targets, necessitating precise evaluation of the scale and cost of carbon dioxide removal. This study examines the availability of land, electricity generation, and geologic CO 2 storage within the United States, estimating a technical potential for low-temperature, adsorbent-based DACS to remove approximately 9 gigatonnes of CO 2 annually. By 2050, a substantial portion of this removal could be achieved at net-removed costs below $\$$300/tonneCO 2 , though costs are highly variable depending on factors such as facility scale, construction expenses, climate-dependent productivity and heating efficiency, and geologic storage conditions. In the short term, DACS deployment will help identify key research priorities for advancing technology and reducing removal costs. Concurrently, there is an urgent need for scientifically robust and standardized frameworks for monitoring, reporting, and verifying DACS performance across both established and emerging technologies and energy sources.

Carbon capture↗

A Graph-Net with Node Embeddings to Detect False Data Injection Attacks in Photovoltaic Systems

Distributed energy resources (DER) contribute to the operational stability of the larger power grid both at utility-scale as well as commercial and residential scales in aggregated forms. These DER in-turn are susceptible to increasing cyber threats. An adversary can plug into the same local network that a field photovoltaic (PV) system uses to interconnect its data loggers and inverters and manipulate certain measurements collected from the network or trick existing irradiance and inverter readings through false data injection attacks (FDIA). Control routines that rely on these measurements can propagate the false data, impacting critical decisions that result in a suboptimal operation or even cause intentional harm leading to inverter-tripping or unscheduled loads that need to be shed. To detect FDIA in PV systems, the paper introduces an attention-based graph neural network with node embeddings and applied it to a simple prototypical DC-coupled microgrid with PV, energy storage, and load. The algorithm shows a detection accuracy of up to 98.95%. The proposed FDIA detection technique will provide micro-grid operators with an effective method to safeguard their systems, guaranteeing the secure and reliable operation.

Parvez, Imtiaz [Utah Valley University]↗

Evaluating the Risk of Enabling Energy Storage Systems to Provide Multiple Services

Battery energy storage systems (BESS) are emerging as a promising, versatile technology for modern power grids due to their inherent distributed nature, their ability to inject bidirectional power flows and to provide multiple grid services. With the proliferation of intermittent renewable energy resources, the BESS procurement is also expected to increase, thereby creating systematic and strategic opportunities for BESS to various revenue streams for providing multiple grid services. Utilizing a co-simulation architecture, this work presents evaluation framework for enabling Utility-scale BESS with simultaneous provision of multiple services. The proposed framework is implemented on a real-life feeder modeled in GridLAB-D, leveraging multi-service grid support. A Risk-Aware control strategy is also implemented in this work that that takes into account the uncertain nature of some of the stochastic services and ensures the BESS to deliver their service commitments. This promotes overall grid reliability and encourages BESS implementation through the revenue streams from providing multiple grid services.

Theisen, John↗

High-Temperature Linear Receiver Enabled by Multicomponent Aerogels

Concentrating solar thermal (CST) technology has significant potential mainly due to its dispatchability and low cost of storage. However, to compete with other sources, including utility-scale solar PV, its final cost (cents/kWh) still needs to be lowered. Cost reduction can be achieved by improving the system level efficiency of the CST plants through the deployment of advanced power cycles, which operate at high temperatures of ~700°C. However, optical, and thermal losses pose a major challenge to the efficiency of such CST systems. The overall aim of this project is to investigate and de-risk a linear solar receiver concept called an Aerogel Insulated Receiver (AIR) that generates high temperatures (up to 700°C) at a low solar concentration ratio (<100) and with a high collection efficiency (optical × receiver). Our prior work has demonstrated the thermal stability1 and optical and heat-insulating properties2,3 of transparent aerogel insulation at a one-inch scale. The focus of this work is on (1) co-optimization of the geometry of the aerogel tile and receiver enclosure to fit a standard parabolic collector (PTC), (2) scale-up of aerogels into 4-inch tiles while preserving key properties, (3) experimental measurement of receiver heat loss (W/m) in a >70-cm test stand and validation of anticipated receiver performance at high temperatures. Regarding (1), appropriate optical and thermal models for a parabolic trough receiver (PTR) are developed and validated. The geometry of the aerogels and the receiver enclosure are co-optimized to maximize the collection efficiency. The model predicts a 54% collection efficiency at 700°C for an AIR design based on flat aerogels. By combining the collection efficiency with the power block efficiency of supercritical CO 2 cycles, we predict >10% improvements in peak plant efficiency relative to existing line-focusing CST systems. The application of curved plasmonic aerogels is predicted to further increase the collection efficiency to 64%. Regarding (2), we demonstrate the successful development of 6-inch-long refractory aerogel tiles with optical, thermal, and stability characteristics consistent with our prior work. This scale-up requires a transition to a larger ALD station and modifying the ALD process variables such as exposure time and the number of precursor doses. Regarding (3), we design and develop an AIR test stand measuring 3 feet in length. Heat loss performance analysis is carried out using the test stand. The results indicate that aerogel insulation can significantly reduce receiver thermal losses at the high operating temperatures required for next-generation PTRs. The experimental results agree with the heat loss performance predicted by our receiver model. Lastly, we conducted preliminary failure mode and effects (FMEA) and techno-economic (TEA) analyses to identify failure mitigation strategies and commercial opportunities, respectively. Overall, this project identifies key opportunities and challenges in deploying aerogel insulating receivers in next-generation line-focusing CST technologies.

14 SOLAR ENERGY↗

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY↗

Vulcan Test Platform: Demonstrating the Data Center as a Flexible Grid Asset

Explosive data center demand is outpacing grid infrastructure development. AI workloads and hyperscale cloud growth are creating unprecedented power requirements, while traditional grid expansion faces multi-year development timelines, regulatory hurdles, and decarbonization challenges. Sidewalk Infrastructure Partners recognized this impending crisis years ago and founded Verrus to develop an innovative solution: data centers that function as grid assets rather than passive loads. The Verrus approach integrates proprietary grid-aware controls with battery energy storage systems (BESS) in a medium-voltage architecture that delivers three critical capabilities: Fast-responding demand flexibility that can service requests from the utility within 10 seconds, Uninterrupted transition to islanded operation during grid disturbances, Continuous uptime assurance while maintaining all customer service level commitments Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), we validated these capabilities on Vulcan, a 70 MW utility-scale test platform powered by NREL's ARIES Virtual Emulation Environment. This deployment-ready technology has successfully demonstrated that Verrus data centers can deliver meaningful grid services while maintaining mission-critical reliability. This technical report outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can play a pivotal role in enhancing grid flexibility and reliability, without sacrificing service level guarantees.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control Strategies and Validation in the Hybrid Optimization and Performance Platform (HOPP)

The Hybrid Optimization and Performance Platform (HOPP) is a tool that simulates hybrid power plants in various configurations, and also calculates the financial feasibility of these plants. This report outlines an overview of HOPP and the energy storage dispatch strategies available. It then presents three case studies which demonstrate different applications of HOPP. The first case looks at the profitability of hybrid power plants in different locations in the USA. The second case examines the availability of hybrid power plants to provide energy reliability services. The third case presents a plant that produces both hydrogen and electricity, and demonstrates a dispatch strategy that chooses the most profitable energy vector based on price signals. The next section shows the validation of HOPP on operational data, using data from both unit-scale and utility-scale power plants. This validation process demonstrated that HOPP can simulate the power output of both wind and solar PV plants at both scales with comparable fidelity to an existing commercial software tool. Finally, HOPP is applied in a field test which applies an optimal dispatch strategy to a physical battery in a unit-scale hybrid plant at NREL. HOPP's optimal dispatch strategy, applied in a real-world setting, improved this hybrid plant's ability to meet a load signal while minimizing operational costs.

14 SOLAR ENERGY↗

Storing Affordability: Battery Storage as an Asset to Reduce Data Center Cost Shifts

This report examines how battery energy storage systems (BESS) can help utilities accommodate large load growth while protecting affordability for existing ratepayers. Rapid growth in electricity demand from artificial intelligence (AI) data centers is straining the U.S. grid. Furthermore, many new data centers are entering rural markets, which could offer economic benefits but may also pose implementation challenges for smaller utilities. At the same time, retail electricity prices are increasing faster than inflation, elevating customer affordability as a key challenge. While data centers have not been the primary driver of increases in residential prices to date, they have pushed wholesale energy and capacity prices higher in several markets. Fundamental utility cost-allocation principles show that data center growth can be rate-positive for existing customers only if new peak demand grows faster than the costs a utility must incur to serve it. Several factors, including a utility’s degree of wholesale market exposure, forecast uncertainty and stranded-asset risk, and tariff design can determine the outcome of load growth on retail rates. Energy storage can make several affordability contributions in the face of this landscape of uncertainty and market volatility, including deferral of higher-cost grid investments through improved utilization of existing assets and flexibility of new large loads, insulation from volatile wholesale prices through peak shaving, and reliability support to address grid risks stemming from the behavior of AI data center loads. Different potential BESS deployment pathways—utility-scale front-of-the-meter systems, aggregated small-scale storage installations, and data center-sited behind-the-meter storage—are compared against each other and against conventional capacity alternatives. This framework is intended as a conceptual resource to utilities, particularly smaller public utilities with rural service territories, who may be considering the role that energy storage can play in insulating existing ratepayers from data center cost shifts.

25 ENERGY STORAGE↗