Search NASA⌕ Search

SEARCH · Search NASA

Results for “VACUUM EQUIPMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Laboratory Studies of Astronomical Ices: Reaction Chemistry and Spectroscopy

In this article, we will describe the work of the Cosmic Ice Laboratory at NASA’s Goddard Space Flight Center to characterize the composition of and to understand the chemistry occurring in icy bodies in the Solar System and beyond. Our work has touched on a wide range of extraterrestrial environments including icy interstellar grains, small bodies such as comets and asteroids, and planets and moons. We are especially interested in the chemical and physical changes that occur in ices as a result of thermal changes or exposure to radiation. To this end, we conduct experiments designed to simulate cold extraterrestrial environments and measure physical properties of single- and multi-component ices. We expose ices to radiation (e.g., MeV protons or keV-MeV electrons) or high-energy photons (e.g., UV) to initiate physical and chemical changes. We conduct experiments using cryo-vacuum chambers equipped with analytical tools and radiation sources to make most of our measurements, including the collection of all spectroscopic data,in situ. When possible and appropriate, we also collect reaction products for further ex situ analysis. The work of the Cosmic Ice Lab provides critical data to astrochemists and others seeking to understand observations, make predictions, and plan future space missions.

Christopher K Materese↗

Microbial Pigments and Their Degradation Products as Biosignatures

Carotenoids are a class of vibrant biological pigments that have a characteristic chemical structure centered around a polyene core (Lu et al. 2018). Carotenoids and their derivatives are candidate biosignatures because they can persist in the terrestrial geologic record for up to 1.73 billion years (Vinnichenko et al. 2020), have specific structures that are likely the result of complex pathways, mediate the survival of many microorganisms in Mars and Ocean Worlds analog environments, and are detectable with multiple techniques, including Raman spectroscopy. In this project, we aim to investigate the detectability of carotenoid pigments with different spectroscopic methods to inform future instrument selection. We compare the spectra of five unaltered carotenoids, two model compounds, and carotenoid-forming archaeon with visible and deep UV Raman spectroscopy and UVVis absorption spectrophotometry. We then use one model pigment, beta-carotene, to evaluate the likelihood that unique spectral properties of carotenoids, or their refractory byproducts, would be preserved and detectable on a remote planetary surface by exposing it to simulated conditions for Mars. Sample Acquisition. Pigments betacarotene, lutein, zeaxanthin, astaxanthin, and lycopene were purchased from Sigma Aldrich. Halobacterium salinarum NRC-1 was acquired from Carlina Biological and grown in Halobacterium media. Mineral salts including sodium sulfate, sodium carbonate, and halite were used to form matrices in which the beta-carotene was embedded before exposure. Pigment-mineral mixes were at a 1:10 ratio in water. Analytical Techniques. Deep UV Raman data were collected on a custom laboratory mapping spectrometer called MOBIUS (Mineral and Organic Based Investigations using Ultraviolet Spectroscopy), which is an analog to the SHERLOC instrument on the Mars 2020 Perseverance rover (Bhartia et al. 2021). It features a 248.56 nm NeCu pulsed laser, liquid nitrogen-cooled detector, and tunable optical setup. Visible Raman data were collected using a Horiba Jobin Yvon LabRam HR spectrometer with a frequencydoubled Nd:YAG laser (532 nm) and a HeNe laser (633 nm). A VWR 6300 PC UV/Visible Spectrophotometer was used to collect absorption data for carotenoid solutions, model compounds, and solvents in UVpermissible capped cuvettes. Data were collected from 190-1100 nm at 1 nm increments. All spectral data were analyzed using Igor Pro 9 (Wavemetrics). Irradiation. We used a vacuum chamber equipped with a cryostat and a flood electron gun to simulate Martian surface temperatures, low pressures, and ionizing radiation (10keV, 10μA for 6h at 200K for our initial tests). The samples were prepared by drying the pigment-mineral mix onto polished metal tabs, then mounted on the cryostat for processing. Samples were then analyzed directly on the tabs after exposure. Results: In comparing the visible and deep UV Raman spectra of unaltered pigments, we found that they differed drastically. Carotenoids are often studied with visible Raman and typically have peaks at 1525 cm-1 and 1157 cm-1, due to the stretching of the C=C and C-C bonds in the polyene structure. However, in deep UV, the strongest feature is at ~1630 cm-1 and is broad, possibly indicating that multiple peaks are forming this feature. This stark difference is likely due to different preresonant enhancement effects. The UV-Vis results show that there is an absorption band in the deep UV <300 nm, which supports the hypothesis that the 248.6 nm excitation is interrogating another aspect of carotenoids than visible Raman. Our preliminary exposure tests indicated that pigments – even without minerals present - were largely unaltered in the applied conditions, with only a slight broadening in the primary polyene peaks apparent in the visible Raman data. Figure 1. A) Visible vs. deep UV Raman spectra of unaltered beta carotene. B) Schematic of exposure. Conclusions: Our results to date indicate that deep UV and visible Raman spectroscopy, both techniques with planetary mission heritage from Mars 2020 (Wiens et al. 2021, Bhartia et al. 2021), may be used in a complementary manner to observe carotenoids. In addition, we find that beta-carotene is largely resistant to our current exposure conditions, though there may be some amount of amorphization of the material which could cause the broadening of the peaks at 1525 and 1157 cm-1. As a next step, we aim to increase the dosage and duration of exposure to observe degradation of the parent pigment, possibly add UV as a factor via an Ar mini-arc UV lamp and use GC-MS to characterize possible degradation products.

pigments↗

Robot For Infrared Mapping Of A Large Assembly In A Vacuum

Robotic system devised for use in infrared mapping of large assembly of equipment under test in vacuum chamber. Thermal images recorded from almost any direction. In original intended application, assembly thermally mapped is spacecraft, but system also used on integrated-circuit-fabrication equipment or other industrial equipment operating in vacuum. Mechanism operated in high vacuum and extreme cold.

Mcaffee, Douglas A.↗

Thermal Vacuum Testing of the Crew and Equipment Translation Aid for the International Space Station

The Crew and Equipment Translation Aid (CETA) is a human powered cart that will aid astronauts in conducting extra-vehicular activity (EVA) maintenance on the International Space Station (ISS). There are two critical EVA tasks relevant to the successful operation of the CETA. These are the removal of the launch restraint bolts during its initial deployment from the Space Shuttle payload bay and the manual deceleration of the cart, its two onboard astronauts, and a payload. To validate the launch restraint and braking system designs, the hardware engineers needed to verify their performance in an environment similar to that in which it will be used. This environment includes the vacuum of low earth orbit and temperatures as low as -11O F and as high as +200 F. The desire for quantitative data, as opposed to subjective information which could be provided by a suited astronaut, coupled with test scheduling conflicts resulted in an unmanned testing scenario. Accommodating these test objectives in an unmanned test required a solution that would provide remotely actuated thermal vacuum compatible torque sources of up to 25 ft-lbs at four horizontally oriented and four vertically oriented bolts, a variable input force of up to 125 lbs at the four brake actuators, and thermal vacuum compatible torque and force sensors. The test objectives were successfully met in both the thermal Chamber H and the thermal vacuum Chamber B at NASA's Johnson Space Center.

Blanco, Raul A.↗

Plasma Facing Component Characterization and Correlation With Plasma Conditions in Lithium Tokamak Experiment-β

Lithium coatings in the Lithium Tokamak eXperiment (LTX) led to flat temperature profiles. The flat temperature profiles were observed along with a hot, low density edge, implying a broad, collisionless scrape-off layer (SOL). Additionally, in vacuo X-ray photoelectron spectroscopy (XPS) measurements established that lithium coatings evaporatively deposited onto high-Z plasma facing components (PFCs) became oxidized while retaining the ability to achieve good plasma performance long after lithium was applied to the PFCs. Longstanding theory predicted flat temperature profiles with low recycling walls, which was presumed to be due to hydrogen binding with elemental lithium to form lithium hydride. The presence of oxidized lithium, however, raised questions regarding the exact mechanism of hydrogen retention in LTX. To investigate these questions, the upgraded facility LTX- β includes a new sample exposure probe (SEP) for more detailed in vacuo analysis of PFC samples. The SEP is equipped with a vacuum suitcase capable of transporting samples representative of the LTX- β outer midplane PFCs to a stand-alone XPS system while maintaining pressures lower than the LTX- β base vacuum to limit the contamination between sample exposure and analysis. The low-energy resolution XPS system used in past experiments could only enable the determination of elemental percentages on the PFC sample surfaces. Because the new XPS system has higher energy resolution, it is more direct to assign chemical compounds to the measured binding energies. This capability has been confirmed by comparing XPS data from PFC test samples with measurements using a commercial high-resolution XPS system. Quartz crystal microbalances (QCMs) were used to quantify the thickness of the deposited lithium on the LTX- β PFCs. This article describes the application of the SEP to characterize the PFC surfaces using XPS and their relationship to plasma conditions.

Maan, Anurag↗

RESOLVE Project

The RESOLVE project is a lunar prospecting mission whose primary goal is to characterize water and other volatiles in lunar regolith. The Lunar Advanced Volatiles Analysis (LAVA) subsystem is comprised of a fluid subsystem that transports flow to the gas chromatograph- mass spectrometer (GC-MS) instruments that characterize volatiles and the Water Droplet Demonstration (WDD) that will capture and display water condensation in the gas stream. The LAVA Engineering Test Unit (ETU) is undergoing risk reduction testing this summer and fall within a vacuum chamber to understand and characterize C!Jmponent and integrated system performance. Ray will be assisting with component testing of line heaters, printed circuit heaters, pressure transducers, temperature sensors, regulators, and valves in atmospheric and vacuum environments. He will be developing procedures to guide these tests and test reports to analyze and draw conclusions from the data. In addition, he will gain experience with preparing a vacuum chamber with fluid and electrical connections. Further testing will include integrated testing of the fluid subsystem with the gas supply system, near-infrared spectrometer, WDD, Sample Delivery System, and GC-MS in the vacuum chamber. This testing will provide hands-on exposure to a flight forward spaceflight subsystem, the processes associated with testing equipment in a vacuum chamber, and experience working in a laboratory setting. Examples of specific analysis Ray will conduct include: pneumatic analysis to calculate the WOO's efficiency at extracting water vapor from the gas stream to form condensation; thermal analysis of the conduction and radiation along a line connecting two thermal masses; and proportional-integral-derivative (PID) heater control analysis. In this Research and Technology environment, Ray will be asked to problem solve real-time as issues arise. Since LAVA is a scientific subsystem, Ray will be utilizing his chemical engineering background to operate the near-infrared spectrometer and GC-MS instruments during ETU testing. Ray will be working with Modified Commercial off the Shelf (MCOTS) instruments and characterizing their analytical behavior for optimization. Ray will be offered the opportunity to suggest testing modifications or configuration changes at any time to improve the experimental effectiveness. He will gain many skills needed for working in a technical team setting requiring flexibility and critical thinking.

Parker, Ray O.↗

RESOLVE Project

The RESOLVE project is a lunar prospecting mission whose primary goal is to characterize water and other volatiles in lunar regolith. The Lunar Advanced Volatiles Analysis (LAVA) subsystem is comprised of a fluid subsystem that transports flow to the gas chromatograph - mass spectrometer (GC-MS) instruments that characterize volatiles and the Water Droplet Demonstration (WDD) that will capture and display water condensation in the gas stream. The LAVA Engineering Test Unit (ETU) is undergoing risk reduction testing this summer and fall within a vacuum chamber to understand and characterize component and integrated system performance. Testing of line heaters, printed circuit heaters, pressure transducers, temperature sensors, regulators, and valves in atmospheric and vacuum environments was done. Test procedures were developed to guide experimental tests and test reports to analyze and draw conclusions from the data. In addition, knowledge and experience was gained with preparing a vacuum chamber with fluid and electrical connections. Further testing will include integrated testing of the fluid subsystem with the gas supply system, near-infrared spectrometer, WDD, Sample Delivery System, and GC-MS in the vacuum chamber. This testing will provide hands-on exposure to a flight forward spaceflight subsystem, the processes associated with testing equipment in a vacuum chamber, and experience working in a laboratory setting. Examples of specific analysis conducted include: pneumatic analysis to calculate the WDD's efficiency at extracting water vapor from the gas stream to form condensation; thermal analysis of the conduction and radiation along a line connecting two thermal masses; and proportional-integral-derivative (PID) heater control analysis. Since LAVA is a scientific subsystem, the near-infrared spectrometer and GC-MS instruments will be tested during the ETU testing phase.

Parker, Ray↗

Regulated-current dc power supply for gaseous-discharge lamps

Controlled current source having a high output resistance feeds continuous-flow hydrogen lamps in vacuum-ultraviolet photometric equipment. The power supply, also used with low-pressure sealed lamps, has a short recovery time and smooth regulation without overshoot.

Freeman, W.↗

Planetary quarantine

Methods for presterilization cleaning or decontamination of spacecraft hardware to reduce microbial load, without harming materials or spacecraft components, are investigated. Three methods were considered: (1) chemicals in liquid form, relying on physical removal as well as bacterial or bacteriostatic action; (2) chemicals used in the gaseous phase, relying on bacterial activity; and (3) mechanical cleaning relying on physical removal of organisms. These methods were evaluated in terms of their effectiveness in microbial burden reduction and compatibility with spacecraft hardware. Results show chemical methods were effective against spore microorganisms but were harmful to spacecraft materials. Mechanical methods were also effective with the degree depending upon the type of instrument employed. Mechanical methods caused problems in handling the equipment, due to vacuum pressure damaging the very thin layered materials used for shielding, and the bristles used in the process caused streaks or abrasions on some spacecraft components.

Source record↗

Making Excited Oxygen Molecules And Atoms

Oxidation of semiconductors and high-temperature superconductors achieved at lower temperatures by use of oxygen molecules or atoms raised into specific excited states. Use of excited oxygen (or other species) of interest in research on kinetics and mechanisms of chemical reactions. Used in ultra-high-vacuum chamber also equipped for such surface-analytical techniques as x-ray photoelectron spectroscopy.

Vasquez, Richard P.↗

Primary research efforts on exploring the commercial possibilities of thin film growth and materials purification in space

The progress made on research programs in the 1987 to 1988 year is reported. The research is aimed at producing thin film semiconductors and superconductor materials in space. Sophisticated vacuum chambers and equipment were attained for the epitaxial thin film growth of semiconductors, metals and superconductors. In order to grow the best possible epitaxial films at the lowest possible temperatures on earth, materials are being isoelectronically doped during growth. It was found that isoelectrically doped film shows the highest mobility in comparison with films grown at optimal temperatures. Success was also attained in growing epitaxial films of InSb on sapphire which show promise for infrared sensitive devices in the III-V semiconductor system.

Source record↗

Lightweight Radiator Fin

Lightweight radiator fin made of tapered panels bent together at ends and joined to heat pipe in middle. Taper chosen for minimum mass per unit of radiated power. Intended primarily for use as part of cooling system of space station, also used on Earth to cool equipment in laboratory vacuum. Possible to modify basic design equations to design minimum-mass fins for cooling by conduction or convection.

Long, W. Russ, III↗

Facility for continuous CVD coating of ceramic fibers

An inductively heated CVD furnace of pilot-plant scale, whose hot zone is 150 mm in diameter x 300 mm in length, has been adapted for continuous coating of ceramic yarns. Coatings at very low pressures are possible in this facility due to the fact that the entire apparatus, including yarn feeding and collecting equipment, is under vacuum. SiC yarn has been coated with 0.1-0.2 microns of BN at yarn speeds of 60 cm/min; a 500-m spool; was coated in about 14 hrs. Coating capacity was tripled by adding pulleys to allow three yarn passes through the furnace.

Moore, Arthur W.↗

Global Auroral Imaging for the Dynamics Explorer Mission

The two Dynamics Explorer spacecraft, DE-1 and DE-2, were launched on August 3, 1981, into polar coplanar orbits at different altitudes for the purpose of studying interactive processes within the atmosphere-ionosphere-magnetosphere system. The DE-1 spacecraft (high-altitude mission) used an elliptical orbit that was selected to allow: (1) measurements extending from the hot magnetospheric plasma through the plasmasphere to the cool ionosphere; (2) global auroral imaging, wave measurements in the heart of the magnetosphere, and crossing of auroral field lines at several earth radii; and (3) measurements for significant periods of time along a magnetic field flux tube. The orbit of Dynamics Explorer 1 offered an opportunity to obtain global images of Earth's dayglow and auroral luminosities and to acquire consecutive images of the entire auroral oval during the growth, onset, expansion, and recovery phases of substorms. The University of Iowa's Spin-scan Auroral Imaging (SAI) instrument, was on-board DE-1. SAI was activated in orbit and placed in routine operation on September 23, 1981, and has provided outstanding new contributions in the fields of auroral, magnetospheric and geocoronal physics, introduced a powerful tool for the study of global atmospheric ozone, and initiated the first search from space for marine bioluminescence on the surface of the global ocean. The SAI instrumentation consists of three imaging photometers, two for visible wavelengths and the third for vacuum-ultraviolet wavelengths equipped with primary catoptric optics with superpolished mirror surfaces. The primary focusing element is an off-axis section of a parabolic mirror that is used to provide an optical path completely free of support structures for the mirrors.

Frank, L. A.↗

Addressing EO-1 Spacecraft Pulsed Plasma Thruster EMI Concerns

The Pulsed Plasma Thruster (PPT) Experiment on the Earth Observing One (EO-1) spacecraft has been designed to demonstrate the capability of a new generation PPT to perform spacecraft attitude control. Results from PPT unit level radiated electromagnetic interference (EMI) tests led to concerns about potential interference problems with other spacecraft subsystems. Initial plans to address these concerns included firing the PPT at the spacecraft level both in atmosphere, with special ground support equipment. and in vacuum. During the spacecraft level tests, additional concerns where raised about potential harm to the Advanced Land Imager (ALI). The inadequacy of standard radiated emission test protocol to address pulsed electromagnetic discharges and the lack of resources required to perform compatibility tests between the PPT and an ALI test unit led to changes in the spacecraft level validation plan. An EMI shield box for the PPT was constructed and validated for spacecraft level ambient testing. Spacecraft level vacuum tests of the PPT were deleted. Implementation of the shield box allowed for successful spacecraft level testing of the PPT while eliminating any risk to the ALI. The ALI demonstration will precede the PPT demonstration to eliminate any possible risk of damage of ALI from PPT operation.

Zakrzwski, C. M.↗

Automated Electrostatics Environmental Chamber

The Mars Electrostatics Chamber (MEC) is an environmental chamber designed primarily to create atmospheric conditions like those at the surface of Mars to support experiments on electrostatic effects in the Martian environment. The chamber is equipped with a vacuum system, a cryogenic cooling system, an atmospheric-gas replenishing and analysis system, and a computerized control system that can be programmed by the user and that provides both automation and options for manual control. The control system can be set to maintain steady Mars-like conditions or to impose temperature and pressure variations of a Mars diurnal cycle at any given season and latitude. In addition, the MEC can be used in other areas of research because it can create steady or varying atmospheric conditions anywhere within the wide temperature, pressure, and composition ranges between the extremes of Mars-like and Earth-like conditions.

Calle, Carlos↗