Search NASA⌕ Search

SEARCH · Search NASA

Results for “VACUUM GAUGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Thermal and Evolved Gas Analysis of Hydromagnesite and Nesquehonite: Implications for Remote Thermal Analysis on Mars

Volatile-bearing minerals (e.g., Fe-oxyhydroxides, phyllosilicates, carbonates, and sulfates) may be important phases on the surface of Mars. In order to characterize these potential phases the Thermal Evolved-Gas Analyzer (TEGA), which was onboard the Mars Polar Lander, was to have performed differential scanning calorimetry (DSC) and evolved-gas analysis of soil samples collected from the surface. The sample chamber in TEGA operates at about 100 mbar (approximately 76 torr) with a N2, carrier gas flow of 0.4 seem. Essentially, no information exists on the effects of reduced pressure on the thermal properties of volatile-bearing minerals. In support of TEGA, we have constructed a laboratory analog for TEGA from commercial instrumentation. We connected together a commercial differential scanning calorimeter, a quadruple mass spectrometer, a vacuum pump, digital pressure gauge, electronic mass flow meter, gas "K" bottles, gas dryers, and high and low pressure regulators using a collection of shut off and needle valves. Our arrangement allows us to vary and control the pressure and carrier gas flow rate inside the calorimeter oven chamber.

Lauer, H. V., Jr.↗

Thermal Vacuum Test Correlation of a Zero Propellant Load Case Thermal Capacitance Propellant Gauging Analytical Model

This thesis describes the development and correlation of a thermal model that forms the foundation of a thermal capacitance spacecraft propellant load estimator. Specific details of creating the thermal model for the diaphragm propellant tank used on NASA's Magnetospheric Multiscale spacecraft using ANSYS and the correlation process implemented are presented. The thermal model was correlated to within plus or minus 3 degrees Celsius of the thermal vacuum test data, and was determined sufficient to make future propellant predictions on MMS. The model was also found to be relatively sensitive to uncertainties in applied heat flux and mass knowledge of the tank. More work is needed to improve temperature predictions in the upper hemisphere of the propellant tank where predictions were found to be 2 to 2.5 C lower than the test data. A road map for applying the model to predict propellant loads on the actual MMS spacecraft toward its end of life in 2017-2018 is also presented.

Gauging↗

Thermal Vacuum Test Correlation of A Zero Propellant Load Case Thermal Capacitance Propellant Gauging Analytics Model

This thesis describes the development and test data validation of the thermal model that is the foundation of a thermal capacitance spacecraft propellant load estimator. Specific details of creating the thermal model for the diaphragm propellant tank used on NASA's Magnetospheric Multiscale spacecraft using ANSYS and the correlation process implemented to validate the model are presented. The thermal model was correlated to within plus or minus 3 degrees Centigrade of the thermal vacuum test data, and was found to be relatively insensitive to uncertainties in applied heat flux and mass knowledge of the tank. More work is needed, however, to refine the thermal model to further improve temperature predictions in the upper hemisphere of the propellant tank. Temperatures predictions in this portion were found to be 2-2.5 degrees Centigrade lower than the test data. A road map to apply the model to predict propellant loads on the actual MMS spacecraft toward its end of life in 2017-2018 is also presented.

Thermal↗

Laser Metrology Gauges for OSI

Heterodyne interferometers have been commercially available for many years. In addition, many versions have been built at JPL for various projects. This activity is aimed at improving the accuracy of such interferometers from the 1-30 nanometer level to the picometer level for use in the proposed OSI and SONATA missions as metrology gauges. In the null-gauge configuration, we obtained a precision of 0.6 picometers at time scales of 2,500 seconds. In the relative-gauge configuration, we obtained an accuracy of 3.5 picometers rms in vacuum at time scales of few minutes. An absolute gauge with an accuracy of 10 microns over a distance of 10 meters is under construction.

Gursel, Yekta↗

Simulation of Vacuum Chamber Pressure Distribution with Surrogate Modeling and Uncertainty Quantification

A major challenge in understanding differences in electric propulsion performance in ground tests and in space operations concerns the pressure distribution within the test vacuum chamber. The chamber backpressure is much higher than experienced in space, modifying thruster performance and plume dynamics. Numerical simulation is a key element to determining the background conditions in non-ideal vacuum chamber environments. An important parameter for the accurate simulation of chamber backpressure is the probability that an atom will stick to a cryogenic panel used to pump away the plume gases. This quantity can be used to model vacuum pumps in particle-based kinetic numerical methods. In this work, a three-dimensional direct simulation Monte Carlo code is used to model neutral xenon atoms flowing from the anode of the H9 Hall Effect Thruster within the University of Michigan’s Large Vacuum Test Facility. Simulated pressures are compared with ion gauge pressure measurements to infer the effective sticking coefficient of the chamber’s vacuum pumps. A pressure predicting surrogate model is developed for inference of pump sticking coefficients and for uncertainty quantification. This information enables accurate and useful kinetic simulations of electric propulsion thruster plasma plumes in vacuum chambers.

DSMC↗

Feeder For Oxygen-Sensitive Powders

Powder feeder for oxygen-sensitive powders facilitates transfer of powder while protecting it against oxidation. Sight gauge enables continuous monitoring of level to which feeder filled with powder, as well as for visual monitoring of quality powder. Coupling mates with specially designed containers, in which powders packaged under vacuum or inert gas. Eliminating need for unncessary handling of powders and attendant risk of contamination by oxygen. Internal funnel unloads unused powder from feeder in vacuum or inert-gas atmosphere. Pressure gauge monitors pressure of inert backfill gas.

Woodford, William H.↗

Vacuum measurements on the lunar surface.

Results of measurements of neutral gas pressure on the lunar surface made with a cold cathode ionization gauge carried to the moon by Apollo 14. The vacuum quality at the landing site is much influenced by the adsorption of rocket gases and their later release. During surface operations by the astronauts, the pressure was near 10 to the minus 8th torr. No data were obtained between the time of the surface operations and lunar sunset about 12 days later, at which time the temperature fell rapidly to the vicinity of 100 K. The pressure was about 10 to the minus 12th torr shortly after sunset, but intermittent releases of gas, perhaps from within the moon itself, occasionally raised the pressure by less than an order of magnitude for as long as a day or two at a time and on one occasion to about 10 to the minus 10th torr for about an hour. At lunar sunrise, as the surface was warmed rapidly to about 300 K, the pressure rose rapidly to about 10 to the minus 10th torr, most likely due to the release of absorbed gases in the immediate landing area or on the landing module itself. For comparison with interplanetary vacuum conditions, the directed pressure of the solar wind is usually less than 10 to the minus 11th torr and the pressure of random gas motion within the solar wind, less than 10 to the minus 13th torr.

Johnson, F. S.↗

Static pressure orifice system testing method and apparatus

A method and apparatus are presented for pressure testing the static pressure orifices and associated connections used in wind tunnels. A cylindrical module, having in one end an open hemispherical calibration pressure chamber separated from and surrounded by an annular vacuum chamber is placed over the orifice of the system to be tested. O-rings ensure seating and a vacuum seal between the chambered end of the module and the surface around the orifice: one O-ring separates the outer chamber from the outside environment. Ports lead from each of the chambers out the other end of the module to tubes connected to a control box consisting of calibration pressure and vacuum supply lines, bleeder valves, and gauges.

Culotta, R. F.↗

Environmental Influence of Gravity and Pressure on Arc Tracking of Insulated Wires Investigated

Momentary short-circuit arcs between a defective polyimide-insulated wire and another conductor may thermally char (pyrolize) the insulating material. The charred polyimide, being conductive, can sustain the short-circuit arc, which may propagate along the wire through continuous pyrolization of the polyimide insulation (arc tracking). If the arcing wire is part of a multiple-wire bundle, the polyimide insulation of other wires within the bundle may become thermally charred and start arc tracking also (flash over). Such arc tracking can lead to complete failure of an entire wire bundle, causing other critical spacecraft or aircraft failures. Unfortunately, all tested candidate wire insulations for aerospace vehicles were susceptible to arc tracking. Therefore, a test procedure was designed at the NASA Lewis Research Center to select the insulation type least susceptible to arc tracking. This test procedure addresses the following three areas of concern: (1) probability of initiation, (2) probability of reinitiation (restrike), and (3) extent of arc tracking damage (propagation rate). Item 2 (restrike probability) is an issue if power can be terminated from and reapplied to the arcing wire (by a switch, fuse, or resettable circuit breaker). The degree of damage from an arcing event (item 3) refers to how easily the arc chars nearby insulation and propagates along the wire pair. Ease of nearby insulation charring can be determined by measuring the rate of arc propagation. Insulation that chars easily will propagate the arc faster than insulation that does not char very easily. A popular polyimide insulated wire for aerospace vehicles, MIL-W-81381, was tested to determine a degree of damage from an arcing event (item 3) in the following three environments: (1) microgravity with air at 1-atm pressure, (2) 1g with air at 1 atm, and (3) 1g within a 10^-6 Torr vacuum. The microgravity 1-atm air was the harshest environment, with respect to the rate of damage of arc tracking, for the 20 AWG (American Wiring Gauge) MIL-W-81381 wire insulation type . The vacuum environment resulted in the least damage. Further testing is planned to determine if the environmental results are consistent between insulation types and to evaluate the other two parameters associated with arc tracking susceptibility.

Source record↗

Gas flow analysis during thermal vacuum test of a spacecraft

The self-contamination of the IMP-H spacecraft, while it was undergoing thermal and solar vacuum tests, has been investigated in conjunction with the outgassing evaluation and detection of molecular flow anomalies occurring in the test chamber. The pressures indicated by two tubulated ionization gauges were used to calculate flow kinetics in the vacuum chamber. The fluxes of emitted molecules and chamber wall reflected molecules were monitored during the entire test. Representative equations and graphs are presented. Test results indicate that from 3 to 9 of every 100 emitted molecules returned to the spacecraft surface; that self-contamination by noncondensable gases was more severe than that by condensable gases; and that outgassing of the spacecraft was approximately 1.18 x 0.01 g/s after 10 hours and 1.18 x 0.001 after 90 hours of vacuum exposure. Testing deficiencies have been identified, and the type and location of instruments required to measure the outgassing, the degree of contamination, and return flow are discussed.

Scialdone, J. J.↗

Comparisons Between Pretest Prediction and Flight Test Data of Aerodynamic Loading for EFT-1

Exploration Flight Test One (EFT-1) was an incredible milestone in the development NASA's Orion spacecraft. It incorporated hundreds of articles of flight test instrumentation and returned with a wealth of data. Aerodynamic surface pressures were collected during launch vehicle ascent and capsule reentry and descent. These discrete surface pressure measurements enable comparisons to computational results and ground test data. This paper details the comparisons between pre-test predictions and flight test data for the Orion MPCV Crew Module (CM) and Launch Abort Tower (LAT) during all phases of flight. Regions with strong comparisons, poor predictions, and lessons learned are discussed. 38 pressure measurements were made on the LAT during ascent. Nine of the gauges were Honeywell PPTs and the remainder were Kulite pressure transducers. In order to address bias in the Kulites, a two-point linear calibration was used and the details are discussed. Results from the flight are compared to existing database products. 44 pressure measurements were made on the CM during reentry and descent. Nine of the gauges were Honeywell PPTs and the remainder were Kulite pressure transducers. In order to address bias in the Kulites, a tare was made against the vacuum measurements as described below. Once the bias was removed from the gauges, comparisons between predicted loading and the measured results are compared.

Schwing, Alan M.↗