Search NASA⌕ Search

SEARCH · Search NASA

Results for “VACUUM PUMP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Reduction of waveguide vacuum trips in CEBAF accelerating cavities with a combination ion pump and non-evaporable getter pump

Pressure spikes in the fundamental power coupler waveguide are a significant source of trips during the operation of both original and refurbished superconducting radio-frequency cavities installed in the CEBAF accelerator. In its original configuration, two waveguides from a cavity-pair are connected to a single 32 l/s ion pump. In 2017 a new cavity-pair was installed in a refurbished cryomodule in which a NEXTorr® D200-5 combination ion pump and non-evaporable getter pump was installed for each waveguide. It is shown that hydrogen is the dominant residual gas in the waveguide and simulations with Molflow+ indicated that the new pumping scheme allows reducing the pressure at the end of the waveguide by a factor of ~5 , compared to the original configuration. In conclusion, the new cavity-pair has been operating in CEBAF for a total of 431 days and it only had a total of 3 trips due to vacuum spikes in the waveguide.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an accelerator-based neutron source to prototype Mo-99 production, Part II: A liquid LBE loop under a high vacuum

To provide US domestic supply of Mo-99 without using high-enriched uranium (HEU), a subcritical uranium target assembly (UTA) is irradiated by an accelerator-based neutron source to create Mo-99 through fission. Part I of this work discusses the design of a liquid lead–bismuth eutectic (LBE) windowless target for an accelerator-based neutron source development. Part II discusses how to couple this windowless target to an accelerator operating at an ultra-high vacuum and the subcritical UTA cooled by water at room temperature. Due to the windowless design of the target, the liquid LBE flow shares an ultra-high vacuum (<1.3 × 10 -7 Pa or 10 -9 Torr) space with the accelerator. As a result of this shared vacuum space, the LBE system must operate at a high vacuum (10 -3 ~10 -6 Pa or 10 -5 ~10 -8 Torr). A magnetic rotary motion feedthrough unit utilizes magnetic fluid to allow rotation of the pump while maintaining a high vacuum environment. Prior to testing the LBE system under vacuum, a pump curve measurement is performed to estimate flowrate in the system. This measurement also generates data on orifice loss coefficients, which are compared to correlations in literature. The second experiment investigates vacuum level in the LBE system during operation. High vacuum is maintained (10 -3 ~10 -5 Pa or 10 -5 ~10 -7 Torr) during system operation, and a residual gas analyzer (RGA) scan shows that partial pressures of residual gases in the LBE system lower over the duration of LBE system operations. The third experiment investigates the gravity driven liquid LBE flowing out of the target chamber in the return line, which is partially full. If the liquid LBE is not drained quickly enough, flooding in the target chamber could occur. The coefficient n in the Manning equation is found to be around 0.008 s/m 1/3 . The last experiment performed is a demonstration that a vacuum jacket could provide sufficient thermal insulation to allow coupling between 300 °C LBE loop and a water tank at room temperature. In conclusion, the results from these experiments have influenced the development of the neutron source for the future commercial scale Mo-99 production system.

43 PARTICLE ACCELERATORS↗

Laser Transport System Vacuum Simulations and LED Atom Tracker

MAGIS-100 is an experiment using atom interferometry on strontium atoms in a 100m vacuum chamber. The laser travels through a laser transport system (LTS) before going down the chamber. Two projects were completed over the course of the internship. One project was conducting vacuum simulations on the LTS to ensure it meets the experimental pressure requirement of 10-11 torr. This was done by characterizing the pressure profile with variations in pump size, pump spacing, and orifice size. The initial design of the LTS included one 30 L/s ion pump in the high vacuum (HV) region, a lens mount with holes of diameter 0.788”, and three 150 L/s ion pumps in the ultra-high vacuum (UHV) region. After adjusting these variables, it was concluded that the lens mount holes could be reduced to 0.200” in diameter and one 150 L/s ion pump in the UHV could be removed and still meet the experimental requirements. The other project was to design an LED atom tracker that shows the position of the strontium atoms in the 100m shaft. This will help with public outreach by allowing visitors to have a visual of the experiment. An Arduino Uno and Arduino Due were programmed using classical physics formulas to direct the RGB LED strips to flash in sync with the falling atoms. The requirements for powering and connecting the hardware were calculated and recommendations for scaling the system to 100m were made.

43 PARTICLE ACCELERATORS↗

Development of advanced vacuum technologies for extending plasma pulse duration on EAST

Advanced vacuum technologies, including pumping, fueling and wall conditioning, have been successfully developed or upgraded to efficiently control the fuel and impurity particles to extend the plasma pulse duration in the experimental advanced superconducting tokamak (EAST). To improve the particle exhaust rate cryopumps with a 60% increase in pumping speed and ∼2 times increase in saturation capacity have been developed, and molecular pumps with a ∼30% increase in pumping speed have been upgraded. In order to monitor the molecular pump status while avoiding bearing faults and overload accidents, a fault detection system has been built which can offer an early warning to avoid more losses within the fusion device. A series of fueling technologies have been developed including gas injection system, supersonic molecular beam injector, pellet injector (PI), massive gas injector and shattered pellet injector, installed at the midplane and divertor positions at different ports to improve fueling uniformity and efficiency. Meanwhile, routine wall conditioning such as electric and hot N 2 baking, ion cyclotron wall conditioning and glow discharge cleaning have been successfully developed to remove the impurity particles from the inner component and materials. The low Z material wall coating and real-time powder injection during plasma discharge are also designed and applied to further improve particle control capability. Finally, by using these advanced vacuum related technologies, good vacuum (<2 × 10 −6 Pa) and wall conditions are realized, and the fuel and impurity particles can be effectively and stably controlled, which promotes the achievement of the record plasma of ∼1056 s pulse duration with the line-averaged electron density of 1.8 × 10 19 m −3 on EAST. They provide a very important reference for vacuum system design and operation for future fusion devices.

EAST↗

An atomic beam of titanium for ultracold atom experiments

Here we generate an atomic beam of titanium (Ti) using a “Ti-ball” Ti-sublimation pump, which is a common getter pump used in ultrahigh vacuum systems. We show that the sublimated atomic beam can be optically pumped into the metastable 3d 3 ( 4 F)4s a 5 F 5 state, which is the lower energy level in a cycling optical transition that can be used for laser cooling. We measure the atomic density and transverse and longitudinal velocity distributions of the beam through laser fluorescence spectroscopy. We find a metastable atomic flux density of 4.3(2) × 10 9 s -1 cm -2 with a mean forward velocity of 773(8) m/s at 2.55 cm directly downstream of the center of the Ti-ball. Owing to the details of optical pumping, the beam is highly collimated along the transverse axis parallel to the optical pumping beam and the flux density falls off as 1/r. We discuss how this source can be used to load atoms into a magneto-optical trap.

47 OTHER INSTRUMENTATION↗

DESIGN ISSUES AND QUALIFICATION OF HYDROFORMED DOUBLE WALLED EXPANSION JOINTS IN VACUUM SERVICE

The Vacuum Auxiliary System for ITER is devoted to pumping out, venting, and purging the vacuum volumes of the tokamak. Over 5000 clients including the cryostat and vacuum vessel, at 8500 m3 and 1400 m3 respectively, are serviced by approximately 150 pumping stations through 6 km of pipework. The piping and functions provided to the clients include component operation, routing of potentially tritiated gases, and timely leak localization. Expansion joints are used to reduce loadings on pumps and piping stresses but also to qualify in-line components having low allowable design loads. The ITER project utilizes vacuum valves that are not designed to withstand typical piping system loadings and require detailed design and evaluation. Loading scenarios prescribed by governing system specifications must be considered. To maintain allowable design loads for components and to keep piping stresses below code requirements, double walled hydroformed expansion joints have been employed in the design. These are not standard items and require custom fabrication. Installation space constraints and adjacent pipe support attachment location availability at ITER limit standard expansion joint installation guidelines provided by the Expasion Joint Manufacturers Association (EJMA). Careful consideration must be given to the analysis model to ensure proper function and life expectancy of the component. These considerations include accurate accounting of thrust forces, thermal movements, seismic accelerations, equipment and building differential displacements. In addition to displacements, the process internal, external, and interspace pressures affect the qualification and selection of the double walled expansion joints. The calculation results shall confirm that deflections, forces, and moments are reasonable for the size and type required for the system’s demands as evaluated against the manufacturer’s design.

Clark, Forrest [ORNL] (ORCID:0009000678106843)↗

Eliminating Signal Bias Caused by Vacuum System Backstreaming in the Diagnostic Residual Gas Analyzer of ITER

In fusion neutral gas analysis, such as with the Diagnostic Residual Gas Analyzer (DRGA) for ITER, the primary measurement range of interest comprises the low-amu species (1 to 6), especially deuterium and helium. The challenge in successfully obtaining accurate measurements is two-fold. First, the sensitivity of the method must be sufficient to resolve trace amounts accurately; typically, one percent or less. Second, the gas signal from the fusion processes must be free of bias caused by the latent presence (from system outgassing and/or vacuum backstreaming) of these gases to enable accurate interpretation of the measured signal. This latter criterion can be problematic for the lightest gases since there is a propensity for some fraction of the pumped gas load to undergo a phenomenon known as backstreaming. This behavior is manifested in pumping systems for gas properties related to relative atomic weight (lightest) and size (smallest). Backstreaming results in a significant amount of the pumped gas undertaking a reverse flow and re-entering the measurement region; thus, contaminating the forward, real-time measurement. To fully eliminate this adverse effect, a conductance-limiting device – or orifice – has been installed in the high-vacuum pumping system of the present ITER DRGA prototype. The system was already equipped with a secondary turbomolecular pump (TMP), but with limited effectiveness against backstreaming in the inter-pump volume (IPV). This orifice is placed within the suction inlet coupling of the secondary TMP, which is downstream of the IPV. Its objective is to eliminate the backstreaming phenomenon by increasing the back pressure in the IPV. However, the orifice sizing must take into consideration other factors, such as the diagnostic measurement objectives. For example, in the ITER DRGA, one of the measurement requirements is a dynamic response time of ~1s. Fortunately, an added benefit of the pumping restriction created by the orifice is that the upstream pressure increase is beneficial for the DRGA’s optical gas analysis (OGA) sensors. These sensors are attached to the IPV in the present design. The glow discharges, when used as an OGA light source, will typically have a brighter light emission with increasing plasma cell pressure. In addition to the fusion machine research sector, there are other potential applications of this pumping technique where the monitoring of lighter gas concentrations is essential, such as the photolithography process for the semiconductor fabrication of integrated circuits. This presentation will describe the vacuum system used to demonstrate a process to eliminate backstreaming as well as show test results to verify the accomplishment of this critical objective.

Marcus, Chris↗

NSTX-U Machine Core Vacuum Seals Upgrade Design

The vacuum in the National Spherical Torus Experiment Upgrade (NSTX-U) is in the range of 2.66x10⁻⁶ Pa (2x 10⁻⁸ torr). To enhance vacuum seals and lower gas permeation in the NSTX-U and therefore ensuring operation safety and quality, the machine core vacuum seal design has been upgraded using double elastomeric seals and pumped interspaces (guard channels). In NSTX-U machine core, there are six major vacuum seals, including upper and lower vacuum vessel main flanges, upper and lower bellows flanges, and two in the ceramic isolation ring assembly that are mounted to the upper vacuum vessel main flange. The elastomeric seals are commercially available and customized fluorocarbon (Viton) O-rings. To ensure appropriate O-ring compression ratios for the vacuum seal, the O-ring grooves are customized with appropriate tolerances considering specific situations for each seal. In this upgrade, the vacuum in each interspace is designed to reach 13.33 Pa (0.1 torr), thus the overall pressure difference crossing each double O-ring seal is expected to be reduced by at least three orders of magnitude, and accordingly the overall rates of leakage and permeation will be lowered by three orders of magnitude. The corresponding pump-down times for each seal, at room temperature, are estimated at about 60 s. Additionally, the vacuum pumped interspaces will be able to function as a real-time leak monitor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Approaching air buoyancy in aero/cryogel vacuum vessels

Air impermeability has been observed in low-density aerogel and cryogel materials, which has led to a series of experiments to investigate the feasibility of an air buoyant vacuum vessel, as well as the fabrication and testing of sub-buoyant prototypes. Here, bulk samples of silica aerogel were shown to isolate vacuum from ambient air for several hours with optimal vacuum isolation occurring at a density of approximately 85 mg cm –3 . It was demonstrated using polyimide aerogel and cryogel materials that the ability of these foam materials to provide an air impermeable layer between vacuum and atmosphere, in spite of being comprised of mostly void space, is related to material stiffness. It is hypothesized that this behavior is due to local deformation of the random nanostructure of the material. Spherical shell vacuum vessels were produced using the polyimide cryogel, and less than 133 Pa vacuum containment was demonstrated under active pumping. In order to approach the non-buoyant to buoyant transition for these vacuum vessels, a polyimide composite was produced using helical fibers for which preliminary mechanical testing was performed.

36 MATERIALS SCIENCE↗

On the origin of ground-state vacuum-field catalysis: Equilibrium consideration

Recent experiments suggest that vibrational strong coupling (VSC) may significantly modify ground-state chemical reactions and their rates even without external pumping. The intrinsic mechanism of this “vacuum-field catalysis” remains largely unclear. Generally, modifications of thermal reactions in the ground electronic states can be caused by equilibrium or non-equilibrium effects. The former are associated with modifications of the reactant equilibrium distribution as expressed by the transition state theory of chemical reaction rates, while the latter stem from the dynamics of reaching and leaving transition state configurations. In this work, we examine how VSC can affect chemical reactions rates in a cavity environment according to transition state theory. Our approach is to examine the effect of coupling to cavity mode(s) on the potential of mean force (PMF) associated with the reaction coordinate. Within the context of classical nuclei and classical photons and also assuming no charge overlap between molecules, we find that while the PMF can be affected by the cavity environment, this effect is negligible for the usual micron-length cavities used to examine VSC situations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Implementation of extreme ultraviolet spectroscopy on a sheared-flow-stabilized Z pinch

A diagnostic for extreme ultraviolet spectroscopy was fielded on the sheared-flow-stabilized (SFS) fusion Z-pinch experiment (FuZE-Q) for the first time. The spectrometer collected time-gated plasma emission spectra in the 5–40 nm wavelength (30–250 eV) range for impurity identification, radiative power studies, and for plasma temperature and density measurements. The unique implementation of the diagnostic included fast (10 ns risetime) pulsed high voltage electronics and a multi-stage differential pumping system that allowed the vacuum-coupled spectrometer to collect three independently timed spectra per FuZE-Q shot while also protecting sensitive internal components. Analysis of line emission identifies oxygen (N-, C-, B-, Be-, Li-, and He-like O), peaking in intensity shortly after maximum current (>500 kA). This work provides a foundation for future high energy spectroscopy experiments on SFS Z-pinch devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beam Coupling Impedances of Inter-cell Section in Scorpius Linac

The following technical note is prepared for distribution to external project collaborators. An inter-cell pumping section in the Scorpius linac contains a pumping grid with slots, bellows, and vacuum plenum. The beam coupling impedances of the inter-cell section are calculated with CST Studio. Important to note that all impedance values in the tech note below should be divided by a factor of 2 to obtain the beam coupling impedances in their standard definition; see reference for details.

43 PARTICLE ACCELERATORS↗

Electrode ink deposition system for high-throughput polymer electrolyte fuel cell

Systems for creating electrodes for polymer electrolyte membrane fuel cells include an XY stage having a heated vacuum table physically coupled to the XY stage. The vacuum table has a working face with a plurality of channels formed therein to communicate vacuum pressure from a port coupled to a vacuum source to the channels. A sheet of perforated heat-conductive material has staggered holes configured to evenly distribute the vacuum pressure from the channels through the perforated sheet. A heat-conductive wire mesh is placed over the perforated sheet, and has openings smaller than the staggered holes such that a membrane material placed on the wire mesh is not deformed by the vacuum pressure. A nanopipette or micropipette coupled to a pump is configured to deposit electrode ink onto an exposed surface of the membrane material as the controller device causes the XY stage to move the vacuum table to control deposition of the electrode ink onto the surface of the membrane material.

Park, Jae Hyung↗

PARTICULATE STUDY OF NEG PUMPS IRRADIATED IN THE CEBAF TUNNEL

Non-evaporable getter (NEG) pumps are being used to maintain ultra-high vacuum in the beamline of superconducting radio-frequency (SRF) accelerators, such as the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. Because of the sensitivity of the performance of SRF cavities to particulate contamination, it is important to evaluate the integrity of the NEG material after exposure to high radiation during beam operation. The particulate from two NEG pumps based on ZAO® getter alloy was measured with a particle counter in a clean-room. The pumps were assembled onto a hermetically sealed setup which was placed in the CEBAF tunnel. The setup was exposed to 24 h beam operation for ~ 230 days. The total gamma-rays dose measured on the test setup was ~ 1.6 Mrad. The total neutron dose measured at ~ 75 cm of the test setup was ~ 11 krad. The particulate count from the two pumps was measured again in the clean-room after irradiation. Whereas an increase of particulate counts was measured, compared to before irradiation, subsequent measurements indicate the absence of systematically loose particulate. The pumping speed of one of the irradiated pumps was also measured to be consistent with that of a non-irradiated one, corroborating the absence of significant damage to the ZAO® NEG material due to irradiation.

Ciovati, G. [Thomas Jefferson National Accelerator↗

PARTICULATE STUDY OF NEG PUMPS IRRADIATED IN THE CEBAF TUNNEL

Non-evaporable getter (NEG) pumps are being used to maintain ultra-high vacuum in the beamline of superconducting radio-frequency (SRF) accelerators, such as the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. Because of the sensitivity of the performance of SRF cavities to particulate contamination, it is important to evaluate the integrity of the NEG material after exposure to high radiation during beam operation. The particulate from two NEG pumps based on ZAO® getter alloy was measured with a particle counter in a clean-room. The pumps were assembled onto a hermetically sealed setup which was placed in the CEBAF tunnel. The setup was exposed to 24 h beam operation for ~ 230 days. The total gamma-rays dose measured on the test setup was ~ 1.6 Mrad. The total neutron dose measured at ~ 75 cm of the test setup was ~ 11 krad. The particulate count from the two pumps was measured again in the clean-room after irradiation. Whereas an increase of particulate counts was measured, compared to before irradiation, subsequent measurements indicate the absence of systematically loose particulate. The pumping speed of one of the irradiated pumps was also measured to be consistent with that of a non-irradiated one, corroborating the absence of significant damage to the ZAO® NEG material due to irradiation.

Ciovati, Gianluigi [Thomas Jefferson National Acce↗

Liquid hydrogen storage system for heavy duty trucks: Configuration, performance, cost, and safety

In this work, we investigate the potential of liquid hydrogen storage (LH 2 ) on-board Class-8 heavy duty trucks to resolve many of the range, weight, volume, refueling time and cost issues associated with 350 or 700-bar compressed H 2 storage in Type-3 or Type-4 composite tanks. We present and discuss conceptual storage system configurations capable of supplying H 2 to fuel cells at 5-bar with or without on-board LH 2 pumps. Structural aspects of storing LH 2 in double walled, vacuum insulated, and low-pressure Type-1 tanks are investigated. Structural materials and insulation methods are discussed for service at cryogenic temperatures and mitigation of heat leak to prevent LH 2 boiloff. Failure modes of the liner and shell are identified and analyzed using the regulatory codes and detailed finite element (FE) methods. The conceptual systems are subjected to a Failure modes and effects analysis (FMEA) and a safety, codes, and standards (SCS) review to rank failures and identify safety gaps. The results indicate that the conceptual systems can reach 19.6% usable gravimetric capacity, 40.9 g-H 2 /L usable volumetric capacity and $174-183/kg-H 2 cost (2016 USD) when manufactured 100,000 systems annually.

08 HYDROGEN↗

Dual-module humidity pump for efficient air dehumidification: Demonstration and performance limitations

Condensation dehumidification in conventional air conditioning technologies is energy-intensive, accounting for up to 50% of building cooling energy used in some climates. Selective vacuum membrane dehumidification (VMD) is one of the leading alternative dehumidification technologies due to its potential for significant energy savings, and the “dual-module humidity pump” is one of the most promising VMD concepts. Here, this work is the first to provide experimental proof-of-concept for the dual-module humidity pump system and provides the first thermodynamic modeling framework that accounts for realistic steady-state operating limitations, both of which are lacking in the current literature. Additionally, this work is the first to provide a system design solution that overcomes practical challenges associated with air accumulation in the vacuum channels. The experimental results in this work show that the current prototype can remove up to 45% of the water vapor in the air stream, and the vapor pressure difference in the vapor rejection module needs to be approximately 2–4 times greater than that of the dehumidification module in order to maintain balanced mass transfer. The thermodynamic model applied to typical air conditioning conditions shows that the ideal dehumidification (latent) COPs can reach up to 40, but practical COPs are limited to approximately 10. Furthermore, the model shows that the overall energy efficiency increases as the membrane air selectivity increases, though this improvement gradually starts to diminish when the membrane selectivity is increased above 10,000.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗