Search NASA⌕ Search

SEARCH · Search NASA

Results for “VALVES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The Effect of Valve Cooling upon Maximum Permissible Engine Output as Limited by Knock

A Wright GR-1820-G200 cylinder was tested over a wide range of fuel-air ratios at maximum permissible power output as limited by knock with three different degrees of valve cooling. The valves used were stock valves (solid inlet valve and hollow sodium-cooled exhaust valve), hollow valves with no coolant, and hollow valves with flowing water as a coolant. Curves showing the variation in maximum permissible values of inlet-air pressure, indicated mean effective pressure, cylinder charge, and indicated specific fuel consumption with change in fuel-air ratio and valve cooling are shown. The use of valves cooled by a stream of water passing through their hollow interiors permitted indicated mean effective pressures 10 percent higher than the mean effective pressures permissible with stock valves when the engine was operated with fuel-air ratios from 0.055 to 0.065. Operation of the engine with lean mixtures with uncooled hollow valves resulted in power output below the output obtained with the stock valves. The data show an increase in maximum permissible indicated mean effective pressure due to cooling the valves, which averages only 2.1 percent with fuel-air ratios from 0.075 to 0.105.

Munger, Maurice↗

Simple Check Valves for Microfluidic Devices

A simple design concept for check valves has been adopted for microfluidic devices that consist mostly of (1) deformable fluorocarbon polymer membranes sandwiched between (2) borosilicate float glass wafers into which channels, valve seats, and holes have been etched. The first microfluidic devices in which these check valves are intended to be used are micro-capillary electrophoresis (microCE) devices undergoing development for use on Mars in detecting compounds indicative of life. In this application, it will be necessary to store some liquid samples in reservoirs in the devices for subsequent laboratory analysis, and check valves are needed to prevent cross-contamination of the samples. The simple check-valve design concept is also applicable to other microfluidic devices and to fluidic devices in general. These check valves are simplified microscopic versions of conventional rubber- flap check valves that are parts of numerous industrial and consumer products. These check valves are fabricated, not as separate components, but as integral parts of microfluidic devices. A check valve according to this concept consists of suitably shaped portions of a deformable membrane and the two glass wafers between which the membrane is sandwiched (see figure). The valve flap is formed by making an approximately semicircular cut in the membrane. The flap is centered over a hole in the lower glass wafer, through which hole the liquid in question is intended to flow upward into a wider hole, channel, or reservoir in the upper glass wafer. The radius of the cut exceeds the radius of the hole by an amount large enough to prevent settling of the flap into the hole. As in a conventional rubber-flap check valve, back pressure in the liquid pushes the flap against the valve seat (in this case, the valve seat is the adjacent surface of the lower glass wafer), thereby forming a seal that prevents backflow.

Willis, Peter A.↗

Self-Rupturing Hermetic Valve

For commercial, military, and aerospace applications, low-cost, small, reliable, and lightweight gas and liquid hermetically sealed valves with post initiation on/off capability are highly desirable for pressurized systems. Applications include remote fire suppression, single-use system-pressurization systems, spacecraft propellant systems, and in situ instruments. Current pyrotechnic- activated rupture disk hermetic valves were designed for physically larger systems and are heavy and integrate poorly with portable equipment, aircraft, and small spacecraft and instrument systems. Additionally, current pyrotechnically activated systems impart high g-force shock loads to surrounding components and structures, which increase the risk of damage and can require additional mitigation. The disclosed mechanism addresses the need for producing a hermetically sealed micro-isolation valve for low and high pressure for commercial, aerospace, and spacecraft applications. High-precision electrical discharge machining (EDM) parts allow for the machining of mated parts with gaps less than a thousandth of an inch. These high-precision parts are used to support against pressure and extrusion, a thin hermetically welded diaphragm. This diaphragm ruptures from a pressure differential when the support is removed and/or when the plunger is forced against the diaphragm. With the addition of conventional seals to the plunger and a two-way actuator, a derivative of this design would allow nonhermetic use as an on/off or metering valve after the initial rupturing of the hermetic sealing disk. In addition, in a single-use hermetically sealed isolation valve, the valve can be activated without the use of potential leak-inducing valve body penetrations. One implementation of this technology is a high-pressure, high-flow-rate rupture valve that is self-rupturing, which is advantageous for high-pressure applications such as gas isolation valves. Once initiated, this technology is self-energizing and requires low force compared to current pyrotechnic-based burst disk hermetic valves. This is a novel design for producing a single-use, self-rupturing, hermetically sealed valve for isolation of pressurized gas and/or liquids. This design can also be applied for single-use disposable valves for chemical instruments. A welded foil diaphragm is fully supported by two mated surfaces that are machined to micron accuracies using EDM. To open the valve, one of the surfaces is moved relative to the other to (a) remove the support creating an unsupported diaphragm that ruptures due to over pressure, and/or (b) produce tension in the diaphragm and rupture it.

Tucker, Curtis E., Jr.↗

Design and Testing of a Prototype Eddy Current Actuated Valve for the ITER Shattered Pellet Injection System

Reliably mitigating disruptions is essential for ITER to meet its long-term operational research plan without damage to the in-vessel components. Currently, the shattered pellet injection (SPI) technique is the most effective radiator of thermal energy and has been chosen for the baseline disruption mitigation system (DMS) for ITER. The SPI process uses cryogenic temperatures to desublimate material into the barrel of a pipe gun forming a solid cylindrical pellet. Pellets for ITER will initially be hydrogen and hydrogen-neon mixtures. Once formed, pellets are dislodged and accelerated using high-pressure gas (40-60 bar) delivered by a fast-opening valve. The solenoid valves currently used for SPI experiments will not operate in an ITER environment due to the large background magnetic field. An ITER prototype fast-opening valve, called a flyer plate valve (FPV), has been designed and has undergone a wide range of testing. The FPV operates by pulsing current through a pancake coil that is closely coupled with a ``flyer plate.'' The flyer plate is an aluminum plate in which eddy currents are generated creating a repulsive force from the pancake coil. The force generated in the flyer plate rapidly lifts the valve tip off the seat and delivers a pulse of gas to the rear of the pellet, breaking it free from the barrel and accelerating the pellet downstream to its intended target. The design of the valve has been iterated on over the lifetime of this project, as the DMS for ITER shifted from massive gas injection (MGI) to SPI. The most recent design has been tested, and operational ranges have been mapped. The valve must survive 3000+ cycles in an ITER-like magnetic field. The principal functional requirement of this valve is to reliably dislodge and accelerate hydrogen (or H-Ne mixture) pellets into ITER. The valve was mated with an ITER SPI test stand and has been shown to be capable of launching pellets reliably. The valve and power supply design will be discussed in this article, along with the various testing setups used to determine the feasibility of this valve for use on ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mechanical and Hydraulic Actuation Strategies for Mainstage Spool Valves in Hydraulic Motors

A large variety of options for the internal valves of a hydraulic motor are available. Poppet valves, rotary valves, and port plates are common options, but each have drawbacks such as actuation force, complexity, leakage, or friction. An alternative type that is also common is spool valves. Spool valves require minimal actuation force and have low throttling losses if sized correctly. This paper compares two drive options for a mainstage spool valve: a hydraulic pilot from a rotary valve and mechanical actuation. Dynamic models of the two valve configurations are created to carry out design studies and evaluate the performance of the motor. Compressibility effects, viscous drag, and flow forces are included in the model. Simulations show that the rotary valve pilot operation causes an unacceptable lag in the motion of the spool that cannot be corrected without reducing performance when running in reverse. Furthermore, the rotary pilot stage drive results in the motor timing becoming retarded at higher operating speeds. For these reasons, mechanically actuated valves are preferred over pilot operated valves for hydraulic motors operated bi-directionally or across a wide speed range.

42 ENGINEERING↗

Experimental Operation of a Prototype 750C Advanced Chloride Molten Salt Bellows Valve

To achieve DOE 2030 SunShot targets that reduce the cost of liquid-based solar by an additional 40% to 70% beyond 2018 costs, a more reliable, highly manufacturable flow valve, capable of achieving operational temperatures of >700°C is required [1]. This paper investigates the development of an innovative high-temperature chloride molten salt valve, with operation up to 750°C. This valve is intended to be employed within Gen 3 CSP liquid-based thermal energy storage (TES) systems as well as Gen 4 modular salt reactor (MSR) technologies. This work details the general design and flow testing of a bellows-seal flow control valve (FCV). This design includes an integrated closed-loop thermal control system to ensure robust design for freeze-thaw cycles. The self-contained thermal management STM system, is unique in the salt valve industry since it is an integrated solution to provide a consistent, repeatable alternative to typical heat tracing. Additionally, the design includes the employment of a novel heat pipe valve stem to facilitate enhanced passive thermal management into the valve assembly. This valve stem heat pipe is designed to facilitate natural circulation within the bonnet to ensure robust operation, during both nominal and transient thermal operation. The valve body and trim will be designed using SS316H, consistent with Flowserve Corporation’s existing product base and is code qualified but will utilize clad material for materials corrosion, manufacturing cost reduction and compatibility to ensure design flexibility. A test campaign was performed in this investigation utilizing a novel 750°C ternary chloride (20%NaCl/40%MgCl2/40%KCl by mol. wt. %) molten salt flow loop. A discussion about the design and installation of the valves within this test bed is provided for this investigation. Valve test results from this study assessed Cv curves as well as multiple actuator cycles, under varying thermodynamic and operational mode conditions, which would be characteristic within a commercial molten salt facility. The results indicate nominal operation for the baseline design, though improved performance and reliability is expected with the full designed FCV.

Armijo, Kenneth (ORCID:0000000346832147)↗

Carbon Fiber Reinforced Carbon Composite Valve for an Internal Combustion Engine

A carbon fiber reinforced carbon composite valve for internal combustion engines and the like formed of continuous carbon fibers throughout the valve's stem and head is disclosed. The valve includes braided carbon fiber material over axially aligned unidirectional carbon fibers forming a valve stem; the braided and unidirectional carbon fibers being broomed out at one end of the valve stem forming the shape of the valve head; the valve-shaped structure being densified and rigidized with a matrix of carbon containing discontinuous carbon fibers: and the finished valve being treated to resist oxidation. Also disclosed is a carbon matrix plug containing continuous and discontinuous carbon fibers and forming a net-shape valve head acting as a mandrel over which the unidirectional and braided carbon fibers are formed according to textile processes. Also disclosed are various preform valves and processes for making finished and preform carbon fiber reinforced carbon composite valves.

Rivers, H. Kevin↗

Effect of Molding and Machining on Neoflon CTFE M400H Polychlorotrifluoroethylene Rod Stock and Valve Seat Properties

Since 1997 numerous fires have been reported to the Food and Drug Administration involving cylinder valves installed on medical use oxygen cylinders sold and operated within the United States. All of the cylinder valves in question had polychlorotrifluoroethylene (PCTFE) valve seats. Subsequent failure analysis showed that the main seat was the primary source of ignition. A review of the incidents involving cylinder valve fires indicated three possible ignition mechanisms: contaminant promotion, flow friction, and resonance. However, gas purity analysis showed that uncombusted, residual oxygen was within specification. Infrared and energy dispersive spectroscopy further showed that no contaminants or organic compounds were present in the remaining, uncombusted valve seat material or on seat plug surfaces. Therefore, contaminant-promoted ignition did not appear to be responsible for the failures. Observations of extruded material along the outer edge of the coined or loaded seat area produced by cylinder overuse or poppet overload led to concerns that accelerated gas flow across a deformed seat surface could generate enough localized heating to ignite the polymeric seat. Low molecular weight or highly amorphous quick-quenched PCTFE grades might be expected to be especially prone to this type of deformation. Such a failure mechanism has been described as flow friction; however, the corresponding mechanistic parameters are poorly understood. Subsequent revelation of low-temperature dimensional instability by thermomechanical analysis (TMA) in a variety of PCTFE sheet and rod stock samples led to new concerns that PCTFE valve seats could undergo excessive expansion or contraction during service. During expansion, additional extrusion and accompanying flow friction could occur. During contraction, a gap between the seal and adjacent metal surfaces could form. Gas flowing past the gap could, in turn, lead to resonance heating and subsequent ignition as described in ASTM Guide for Evaluation Nonmetallic Materials for Oxygen Service (G 63). Attempts to uncover the origins of the observed dimensional instability were hindered by uncertainties about resin grade, process history, and post-process heat history introduced by machining, annealing, and sample preparation. An approach was therefore taken to monitor property changes before and after processing and machining using a single, well-characterized lot of Neoflon CTFE.1 M400H resin. A task group consisting of the current PCTFE resin supplier, two molders, and four valve seat manufacturers was formed, and phased testing on raw resin, intermediate rod stock, and finished valve seats initiated. The effect of processing and machining on the properties of PCTFE rod stock and oxygen gas cylinder valve seats was then determined. Testing focused on two types of extruded rod stock and one type of compression-molded rod stock. To accommodate valve seat manufacturer preferences for certain rod stock diameters, two representative diameters were used (4.8 mm (0.1875 in.) and 19.1 mm (0.75 in.)). To encompass a variety of possible sealing configurations, seven different valve seat types with unique geometries or machining histories were tested. The properties investigated were dimensional stability as determined by TMA, specific gravity, differential scanning calorimetry (DSC), compressive strength, zero strength time, and intrinsic viscosity. Findings are discussed in the context of polymer structure-process-property relationships whenever possible.

Waller, Jess M.↗

Improved Relief Valve Would Be Less Susceptible to Failure

The balanced-piston relief valve with side vented reaction cavity has been proposed as an improved alternative to a conventional high-pressure, high-flow relief valve. The proposed valve would be less susceptible to failure. A typical conventional high-pressure, high-flow relief valve contains a piston that is exposed to the upstream pressure across the full valve-seat diameter and is held against the valve seat and the upstream pressure by a large spring. In the event of an increase in upstream pressure to a level above the valve set point (the pressure above which the valve opens), the opening force on the piston can be so large that the piston becomes accelerated to a speed high enough that the ensuing hard impact of the piston within the valve housing results in failure of the valve. For a given flow cross section, the proposal would significantly reduce the force, thereby reducing susceptibility to failure. A basic version of the proposed balanced-piston relief valve with side vented reaction cavity is described.

Farner, Bruce R.↗

Experimental and Computational Investigation of Valve Motion in a Resonant Pulse Combustor

The motion of a passive reed-type valve and a poppet-style valve operating in a small scale, liquid-fueled pulse combustor is investigated experimentally. Valve position and combustion chamber pressure are simultaneously measured using an in-house fabricated optical position probe. The reed valve configuration is found to operate in a self-aspirated mode, generating significant pressure gain. The poppet valve configuration cannot operate without forced air, and does not generate pressure gain. Both type valves are tested in combustors of multiple lengths. Close examination of the respective valve motions indicate that the reed valve is highly non-linear, with unique attributes that appear essential for self-aspiration. Dynamic models for the motion of each valve are implemented in a computational fluid dynamic (CFD) simulation of the pulse combustor in order to assess if this unique valve motion is critical to successful operation. The results show that it is. The implications of these results are discussed. The need for active actuation with feedback control, rather than passive valve actuation is highlighted as a critical technology for practical resonant pulse combustors.

Combustion↗

Experimental and Computational Investigation of Valve Motion in a Resonant Pulse Combustor

The motion of a passive reed-type valve and a poppet-style valve operating in a small scale, liquid-fueled pulse combustor is investigated experimentally. Valve position and combustion chamber pressure are simultaneously measured using an in-house fabricated optical position probe. The reed valve configuration is found to operate in a self-aspirated mode, generating significant pressure gain. The poppet valve configuration cannot operate without forced air, and does not generate pressure gain. Both type valves are tested in combustors of multiple lengths. Close examination of the respective valve motions indicate that the reed valve is highly non-linear, with unique attributes that appear essential for self-aspiration. Dynamic models for the motion of each valve are implemented in a computational fluid dynamic (CFD) simulation of the pulse combustor in order to assess if this unique valve motion is critical to successful operation. The results show that it is. The implications of these results are discussed. The need for active actuation with feedback control, rather than passive valve actuation is highlighted as a critical technology for practical resonant pulse combustors.

Combustion↗

Assessment on the Practicality of Off-the-Shelf Valves for Use in Molten Salt

From the mid to late 1960s, the Molten Salt Reactor Experiment (MSRE) was operated at Oak Ridge National Laboratory (ORNL). The MSRE design is unique: instead of standard valves, freeze valves were used to isolate the fluid salt as needed. While standard valves were considered for use in the MSRE, key design challenges (leaking, corrosion, valve alignment, and cold-welding, etc.) were all avoided by choosing a freeze type valve. While the freeze valves were integral to the MSRE’s success, they do not respond quickly, and they are not capable of throttling flow: two key features important to commercial operation and test facilities. More than half a century after the MSRE’s inception, design and manufacturing capabilities have changed. There is a renewed interest in molten salts for energy storage in nuclear and concentrated solar power. Therefore, there is a strong desire to have a functioning valve that can be obtained off the shelf or with minimal modification to a custom valve. This research addresses the known challenges associated with valve selection in fluoride salts, provides guidelines as to potential options for selection of a valve, and uses these guidelines to select a valve for testing in ORNL’s Liquid Salt Test Loop (LSTL).

Howard, Trevor↗

Multi-channel pulsed valve inlet system and method

A multichannel inlet system for a mass spectrometer includes a plurality of valve assemblies coupled to a manifold, and a pulsed valve driver. The manifold is configured to be connected in fluid connection with an ion trap of the mass spectrometer. Each valve assembly includes a valve and an injection port operably coupled to receive the reagent. The valve has an actuated state in which the valve provides fluid communication between the injection port and the manifold, and an unactuated state in which the valve substantially prevents fluid communication between the injection port and the manifold. The pulsed valve driver is operably connected to receive a pulse signal sequence from a processor, and is configured to generate pulsed valve drive signals for one or more of the valves based on the pulse signal sequence to cause a corresponding one of the valves to be in the actuated state.

Kenttamaa, Hilkka↗

Aperture Valve for the Mars Organic Molecule Analyzer (MOMA)

NASA's participation in the multi-nation ExoMars 2018 Rover mission includes a critical astrobiology Mass Spectrometer Instrument on the Rover called the Mars Organic Molecule Analyzer (MOMA). The Aperture Valve is a critical electromechanical valve used by the Mass Spectrometer to facilitate the transfer of ions from Martian soil to the Mass Spectrometer for analysis. The MOMA Aperture Valve development program will be discussed in terms of the Initial valve design and subsequent improvements that resulted from prototype testing. The Initial Aperture Valve concept seemed promising, based on calculations and perceived merits. However, performance results of this design were disappointing, due to delamination of TiN and DLC coatings applied to the Titanium base metals, causing debris from the coatings to seize the valve. While peer reviews and design trade studies are important forums to vet a concept design, results from testing should not be underestimated.Despite the lack of development progress to meet requirements, valuable information from weakness discovered in the Initial Valve design was used to develop a second, more robust Aperture valve. Based on a check-ball design, the ETU flight valve design resulted in significantly less surface area to create the seal. Moreover, PVD coatings were eliminated in favor of hardened, nonmagnetic corrosion resistant alloys. Test results were impressive, with the valve achieving five orders of magnitude better sealing leak rate over end of life requirements. Cycle life was equally impressive, achieving 280,000 cycles without failure.

Mars↗

Aperture Valve for the Mars Organic Molecule Analyzer (MOMA)

NASA's participation in the multi-nation ExoMars 2018 Rover mission includes a critical astrobiology Mass Spectrometer Instrument on the Rover called the Mars Organic Molecule Analyzer (MOMA). The Aperture Valve is a critical electromechanical valve used by the Mass Spectrometer to facilitate the transfer of ions from Martian soil to the Mass Spectrometer for analysis. The MOMA Aperture Valve development program will be discussed in terms of the Initial valve design and subsequent improvements that resulted from prototype testing. The Initial Aperture Valve concept seemed promising, based on calculations and perceived merits. However, performance results of this design were disappointing, due to delamination of TiN and DLC coatings applied to the Titanium base metals, causing debris from the coatings to seize the valve. While peer reviews and design trade studies are important forums to vet a concept design, results from testing should not be underestimated. Despite the lack of development progress to meet requirements, valuable information from weakness discovered in the Initial Valve design was used to develop a second, more robust Aperture valve. Based on a check-ball design, the ETU /flight valve design resulted in significantly less surface area to create the seal. Moreover, PVD coatings were eliminated in favor of hardened, nonmagnetic corrosion resistant alloys. Test results were impressive, with the valve achieving five orders of magnitude better sealing leak rate over end of life requirements. Cycle life was equally impressive, achieving 280,000 cycles without failure.

00000↗

Discharge characteristics of a double injection-valve single-pump injection system

The discharge characteristics of two similar injection valves operated by a single-cylinder fuel-injection pump were determined with an apparatus that measured the quantity of fuel discharged from each valve during every 0.5 degrees of pump rotation. It was found that similar discharges took place from the two valves at all pump speeds when the valve-opening pressures, the nozzle-orifice diameters, and the injection-tube lengths were the same for both valves. Under these conditions, the effects of changing the pump speed, the pump throttle setting, or the nozzle orifice diameter were very similar to those occurring with a single-injection valve. By a proper selection of discharge-orifice areas and valve-opening pressures it was possible to obtain a great many combinations of discharge quantities, discharge rates, and injection timings for the two valves. A series of tests using injection tubes of unequal lengths for the two valves showed that under these conditions the injection timing and the fuel quantity discharged from each valve varies widely and erratically with changes in the pump speed.

Lee, Dana W↗

Static Flow Characteristics of a Mass Flow Injecting Valve

A sleeve valve is under development for ground-based forced response testing of air compression systems. This valve will be used to inject air and to impart momentum to the flow inside the first stage of a multi-stage compressor. The valve was designed to deliver a maximum mass flow of 0.22 lbm/s (0.1 kg/s) with a maximum valve throat area of 0.12 sq. in (80 sq. mm), a 100 psid (689 KPA) pressure difference across the valve and a 68 F, (20 C) air supply. It was assumed that the valve mass flow rate would be proportional to the valve orifice area. A static flow calibration revealed a nonlinear valve orifice area to mass flow relationship which limits the maximum flow rate that the valve can deliver. This nonlinearity was found to be caused by multiple choking points in the flow path. A simple model was used to explain this nonlinearity and the model was compared to the static flow calibration data. Only steady flow data is presented here. In this report, the static flow characteristics of a proportionally controlled sleeve valve are modelled and validated against experimental data.

Mattern, Duane↗

Thermostatic Valves Containing Silicone-Oil Actuators

Flow-splitting and flow-mixing thermally actuated spool valves have been developed for controlling flows of a heat-transfer fluid in a temperature-regulation system aboard the Mars Science Laboratory (MSL) rover. Valves like these could also be useful in terrestrial temperature-regulation systems, including automobile air-conditioning systems and general refrigeration systems. These valves are required to provide smoother actuation over a wider temperature range than the flow-splitting, thermally actuated spool valves used in the Mars Explorer Rover (MER). Also, whereas the MER valves are unstable (tending to oscillate) in certain transition temperature ranges, these valves are required not to oscillate. The MER valves are actuated by thermal expansion of a wax against spring-loaded piston rods (as in common automotive thermostats). The MSL valves contain similar actuators that utilize thermal expansion of a silicone oil, because silicone-oil actuators were found to afford greater and more nearly linear displacements, needed for smoother actuation, over the required wider temperature range. The MSL valves also feature improved spool designs that reflect greater understanding of fluid dynamics, consideration of pressure drops in valves, and a requirement for balancing of pressures in different flow branches.

Bhandari, Pradeep↗