Search NASA⌕ Search

SEARCH · Search NASA

Results for “Variable Speed Pumps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Dynamic Modeling and Grid Interaction of a Tidal and River Generator

This presentation provides a high-level overview of the deployment of a river generator installed in a small system. The turbine dynamics of a river generator, electrical generator, and power converter are modeled in detail. Various simulations can be exercised, and the impact of different control algorithms, failures of power switches, and corresponding impacts can be examined.

13 HYDRO ENERGY↗

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Extension of a Virtual Refrigerant Charge Sensor

The primary goal of the work described in this paper was to evaluate and extend a virtual refrigerant charge sensor (VRC) for determining refrigerant charge for equipment having variable-speed compressors and fans. To evaluate the accuracy of the VRC, data were first collected from previous laboratory tests for different systems and over a wide range of operating conditions. In addition, new laboratory tests were performed to consider conditions not available within the existing data set. The systems for the new laboratory tests were two residential ductless split heat pump systems that employ a variable-speed compressor and R-410a as the refrigerant. Based on the evaluations, the original virtual charge sensor (termed model I) was found to work well in estimating the refrigerant charge for systems with a variable-speed compressor under many operating conditions. However, for extreme test conditions such as low outdoor temperatures and low compressor speed, the VRC needed to be improved. To overcome the limitations, the model associated with the VRC sensor was modified to include a term involving the inlet quality to the evaporator estimated from the condenser outlet condition (termed model II). Both model I and II showed good performance in terms of predicting charge levels for systems with a constant speed compressor, but model II gave better performance for systems with a variable-speed compressor. However, when the superheat of the compressor was zero, neither model I nor II could accurately predict charge level. Therefore, a third approach (Model III) was developed that includes the discharge superheat of the compressor. This model improved performance for a laboratory-tested system that included a number of points with no superheat entering the compressor.

Kim, Woohyun↗

Fractional order PID controller for improvement of PMSM speed control in aerospace applications

Because of the benefits reduced size, cost and maintenance, noise, CO2 emissions and increased control flexibility and precision, to meet these expectations, electrical equipment increasingly utilize in modern aircraft systems and aerospace industry rather than conventional mechanic, hydraulic, and pneumatic power systems. Electric motor drives are capable of converting electrical power to drive actuators, pumps, compressors, and other subsystems at variable speeds. In the past decades, permanent magnet synchronous motor (PMSM) and brushless dc (BLDC) motor were investigated for aerospace applications such as aircraft actuators. In this paper, the fractional-order PID controller is used in the design of speed loop of PMSM speed control system. Having more parameters for tuning fractional order PID controller lead to good performance ratio to integer order. This good performance is shown by comparison fractional order PID controller with the conventional PI and tuned PID controller by Genetic algorithm in MATLAB soft wear.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development and Experimental Hardware Validation of Novel Variable Speed Hydropower Control Schemes for Emerging Applications and Water Resource Paradigms

Recent opportunities for new hydropower generation in the United States have often been in non-powered dams and run-of-river type flows occurring in low-impact natural areas and unregulated conduits. At the same time, a changing water resource paradigm is challenging some existing generation in drought stricken areas where supply reservoirs behind many medium and high head units are at historically low levels. The result is a developing market space which is potentially best captured by machines capable of variable speed operation. Variable speed units have a wider range of operating conditions compared to their synchronous counterparts and have already proven their resilience through a 20+ year history in pumped hydro applications. This work develops a control scheme for variable speed hydropower units operating to deliver a set-point power through flow controlling gates. This control scheme increases both the hydrologic operating range of a unit as well as the speed of response to grid contingencies under droop and automatic generator control. Results from simulation are confirmed on hardware.

Starrett, Mike↗

Compressor Selection and Equipment Sizing for Cold Climate Heat Pumps

In order to limit heating capacity degradation at -25 C (-13 F) ambient to 25%, compared to the nominal rating point capacity at 8.3 C (47 F), an extensive array of design and sizing options were investigated, based on fundamental equipment system modeling and building energy simulation. Sixteen equipment design options were evaluated in one commercial building and one residential building, respectively in seven cities. The energy simulation results were compared to three baseline cases: 100% electric resistance heating, a 9.6 HSPF single-speed heat pump unit, and 90% AFUE gas heating system. The general recommendation is that variable-speed compressors and tandem compressors, sized such that their rated heating capacity at a low speed matching the building design cooling load, are able to achieve the capacity goal at low ambient temperatures by over-speeding, for example, a home with a 3.0 ton design cooling load, a tandem heat pump could meet this cooling load running a single compressor, while running both compressors to meet heating load at low ambient temperatures in a cold climate. Energy savings and electric resistance heat reductions vary with building types, energy codes and climate zones. Oversizing a heat pump can result in larger energy saving in a less energy efficient building and colder regions due to reducing electric resistance heating. However, in a more energy-efficient building or for buildings in warmer climates, one has to consider balance between reduction of resistance heat and addition of cyclic loss.

Building Energy Simulation↗

Field Validation of Innovative Air-Source Heat Pumps for Cold-Climate Heating Applications

Air-source heat pumps (ASHPs) have historically found application in milder climates in the United States (US). Their application in cold climates has been hindered by reduced performance as outdoor temperatures fall below freezing and the need for backup or auxiliary electric resistance heaters to meet peak heating loads. Recent advances in cold-climate air-source heat pumps (ccASHPs) with features such as variable-speed compressors, multistage systems, and highly optimized thermal design have improved performance by increasing the coefficient of performance (COP), low-ambient-temperature capacity, and heating seasonal performance factor (HSPF) dramatically. Despite their benefits, ccASHPs are still not widely prescribed for cold climate conditions. This is due in part to a lack of verified, demonstrated performance and analysis in cold climates. Ultimately, high-efficiency ccASHPs play a key role in emerging energy/grid renovation efforts in addition to their potential energy savings and avoided carbon emissions, but their actual performance in various cold climate field settings must be better understood. The primary objective of this project was to measure the in-field performance of variable-capacity air-source heat pumps in cold climates with the goal of enabling the development of field-based performance maps. Specifically, the study looked at how the heat pumps operated in the field, the frequency of cycling, the frequency of defrost events, and the time spent in each mode of operation. The results are intended to be used by DOE to inform research and development of energy-efficient equipment and to develop guidelines for optimizing primary energy savings when using air-source heat pumps in heating-dominated regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rates of fuel discharge as affected by the design of fuel-injection systems for internal-combustion engines

Using the method of weighing fuel collected in a receiver during a definite interval of the injection period, rates of discharge were determined, and the effects noted, when various changes were made in a fuel-injection system. The injection system consisted primarily of a by-pass controlled fuel pump and an automatic injection valve. The variables of the system studied were the pump speed, pump-throttle setting, discharge-orifice diameter, injection-valve opening and closing pressures, and injection-tube length and diameter.

Gelalles, A G↗

Investigation of a high-temperature combination heat pump for lower-cost electrification in multifamily buildings

The development of space and water heating combination heat pumps capable of generating water temperatures high enough for convective heat emitters will enable more cost-effective and equitable decarbonization solutions for electrifying multifamily buildings. Here, in this paper, multifamily building models and a charge-sensitive mechanistic cycle model of a combination heat pump are developed, and the system performance is predicted based on the models. Unlike other state-of-the-art residential heat pumping equipment, the modeled combination heat pump using an economized, fluid-injected variable-speed compressor can achieve higher temperature lifts of 40° - 85°C, with lower installation costs and complexity. The model predicted heating coefficient of performance (COP h ) is 2.1 at an ambient temperature of -15°C with a high-temperature lift of nearly 85°C, and a seasonal coefficient of performance in heating mode (SCOP h ) ranges from 2 - 4 for different locations. The system shows 30% - 90% lower CO 2 eq emissions over a condensing gas boiler and 9% - 13% lower projected installation costs than two separate space and water heat pumping appliances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cold Climate Air-Source Heat Pump Demonstration and Analysis: Experimental Study on Cold Temperature Performance

Space heating energy is the largest end use for U.S. residential buildings, accounting for nearly 45% of residential building energy consumption nationwide, and approximately 51% of space heating energy is consumed on-site by combusting natural gas (EIA 2020a). In Colorado, approximately 53% of the statewide residential building energy consumption goes to space heating, 76% of which is provided by natural gas (EIA 2020a). Heat pumps are an efficient, electric alternative space heating technology and have been proven viable for decades. However, historically air-source heat pumps (ASHPs) have been limited to temperate climates because of (1) subpar performance at extremely cold outdoor air temperatures, (2) the need for air conditioning in summer months, and (3) the availability of natural gas in colder climates. Relatively recent advances to cold climate ASHP technology, which typically relies on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance, enabling the technology to potentially save energy for many homes in cold climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DEVELOPMENT OF COLD CLIMATE HEAT PUMP USING TWO-STAGE COMPRESSION

This paper uses a well-regarded, hardware based heat pump system model to investigate a two-stage economizing cycle for cold climate heat pump applications. The two-stage compression cycle has two variable-speed compressors. The high stage compressor was modelled using a compressor map, and the low stage compressor was experimentally studied using calorimeter testing. A single-stage heat pump system was modelled as the baseline. The system performance predictions are compared between the two-stage and single-stage systems. Special considerations for designing a cold climate heat pump are addressed at both the system and component levels.

Cold Climate↗

Description of the 3 MW SWT-3 wind turbine at San Gorgonio Pass, California

The SWT-3 wind turbine, a microprocessor controlled three bladed variable speed upwind machine with a 3MW rating that is presently operational and undergoing system testing, is discussed. The tower, a rigid triangular truss configuration, is rotated about its vertical axis to position the wind turbine into the prevailing wind. The blades rotate at variable speed in order to maintain an optimum 6 to 1 tip speed ratio between cut in and fated wind velocity, thereby maximizing power extraction from the wind. Rotor variable speed is implemented by the use of a hydrostatic transmission consisting of fourteen fixed displacement pumps operating in conjunction with eighteen variable displacement motors. Full blade pitch with on-off hydraulic actuation is used to maintain 3MW of output power.

Rybak, S. C.↗

Chapter 18: Variable Frequency Drive Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

An adjustable-speed drive (ASD) includes all devices that vary the speed of a rotating load, including those that vary the motor speed and linkage devices that allow constant motor speed while varying the load speed. The Variable Frequency Drive Evaluation Protocol presented here addresses evaluation issues for variable-frequency drives (VFDs) installed on commercial and industrial motor-driven centrifugal fans and pumps for which torque varies with speed. Constant torque load applications, such as those for positive displacement pumps, are not covered by this protocol.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Overall chilled water system energy consumption modeling and optimization

The emergence of increasingly affordable variable-speed drive technology has changed the approach used to control chilled water systems equipped with these drives. The purpose of this research was to develop an integrated chilled water modeling technique that can determine the optimal system setpoints and estimate the energy saving potential of chiller system. The chiller system equipped with Variable Frequency Drives (VFDs) on cooling tower fans and condenser water pumps. To accomplish the objective, physical component models of the centrifugal chiller, cooling tower and condenser water pump were established with the goal of incorporating the system’s condenser water flow rate and cooling tower fan speeds as optimization variables. Furthermore, a cooling load prediction algorithm was developed using a multiple non-linear regression model to approximate the building’s cooling load subject to a range of environmental conditions. The inputs and outputs of the individual component models were linked to estimate how adjusting the cooling tower fan and condenser water pump speed would influence the system’s comprehensive performance. Here, the overall system model was then optimized using a generalized reduced gradient optimization algorithm to determine the potential energy savings through speed control with VFDs and to ascertain a control logic strategy for the building automation system to operate the heating and cooling system. A case-study was performed on a single chiller system at a museum and the model was calibrated according to logged data collected over four months. Results showed that for the system analyzed, the energy saving of optimizing the cooling tower fan system was found to be 12–15%, while the energy saving potential of optimizing the condenser water pump with the cooling tower fan was negligible. Additionally, comparing different cooling tower fan control strategies showed that a wet-bulb approach-based cooling tower control strategy was shown to have the highest correlation to the optimized fan speed with an R 2 of 0.924.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Preliminary design package for solar heating and cooling systems

Summarized preliminary design information on activities associated with the development, delivery and support of solar heating and cooling systems is given. These systems are for single family dwellings and commercial applications. The heating/cooling system use a reversible vapor compression heat pump that is driven in the cooling mode by a Rankine power loop, and in the heating mode by a variable speed electric motor. The heating/cooling systems differ from the heating-only systems in the arrangement of the heat pump subsystem and the addition of a cooling tower to provide the heat sink for cooling mode operation.

Source record↗

A data driven control strategy for optimal and flexible operation of absorption systems; Stratégie de régulation fondée sur les données pour un fonctionnement optimal et flexible des systèmes à absorption

A novel control strategy for vapor absorption systems with experimental validation is presented. Statistical methods are used to integrate a detailed thermodynamic model and system-specific characteristics into a model based control algorithm. This allows for continuously optimized operation as well as fast response to variations in operating conditions. Autonomous controller performance was tested experimentally for response to changes in heat sink and evaporator temperatures. Continuous turndown with fast response to capacity demand changes, in contrast to suboptimal on/off control, was demonstrated. The thermal compressor concept was employed to develop the variable speed thermal compressor module, with aspects specific to absorption heat pumps, also facilitating cross-applicability of vapor compression system control strategies. Our results of this study enable further development and optimization of absorption systems for a wide range of applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Active Power and Flux Control of a Self-Excited Induction Generator for a Variable-Speed Wind Turbine Generation

A Self-Excited Induction Generation (SEIG) for a variable speed wind turbine generation(VS-WG) is normally considered to be a good candidate for implementation in stand-alone applications such as battery charging, hydrogenation, water pumping, water purification, water desalination, and etc. In this study, we have examined a study on active power and flux control strategies for a SEIG for a variable speed wind turbine generation. The control analysis for the proposed system is carried out by using PSCAD software. In the process, we can optimize the control design of the system, thereby enhancing and expediting the control design procedure for this application. With this study, this control design for a SEIG for VS-WG can become the industry standard for analysis and development in terms of SEIG.

17 WIND ENERGY↗

Revised Heating Load Line Analysis: Addendum to ORNL/TM-2015/281

The original heating load line analysis of ORNL TM-2015/281 was modified to incorporate two adjustments of (1) removing mechanical ventilation and (2) resizing the heat pump units based on new criteria. This resulted in a lowering of the HLL slope factor from the originally rounded 1.3 level to 1.15 in DOE Region IV and V while leaving unchanged the zero-load ambient at a rounded value of 55 F. For the other four DOE regions, the zero-load ambients dropped by 1 to 2 F from those found earlier and the rounded HLL slope factors ranged from 1.05 to 1.3. The average rounded HLL slope factor over all six DOE regions is 1.15. Effects of the revised slope factor on rated HSPFs (Region IV) for single- and two-capacity units dropped from 16% in the original work to 12.6% in this report. For VS units, the HSPF reductions of 14 to 25% in the original report were lowered to a range of 9 to 21%. As in the original report, for VS units that do not limit minimum speed operation below 47 F ambient, the average HSPF reduction for the cases evaluated is approximately the same as for single- and two-capacity units. For VS units that do limit minimum speed operation below 47 F ambient, the lower 1.15 slope factor of this report generally results in small overpredictions of rated HSPF by 1 to 3% compared to functional HSPF. An exception is minimum-speed-limited VS units where the minimum speed COP at 47 F is higher than that at 62 F; one such unit was found to have an HSPF overprediction of over 14% with the 1.15 HLL slope factor level. For such VS exception cases, a default HSPF penalty should be considered. For the more typical VS units that limit minimum speed operation, use of a 1.15 slope factor for rated HSPF was found to still acceptably limit the HSPF error. If slope factors lower than 1.15 are used for HSPF ratings, some means should be considered to appropriately derate the HSPFs for VS units which limit minimum speed operation below 47 F ambient.

42 ENGINEERING↗