Search NASA⌕ Search

SEARCH · Search NASA

Results for “Visual Examination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Foam-assisted delivery of nanoscale zero valent iron in porous media

Foam is potentially a promising vehicle to deliver nanoparticles for vadose zone remediation as foam can overcome the intrinsic problems associated with solution-based delivery, such as preferential flow and contaminant mobilization. In this work, the feasibility of using foam to deliver nanoscale zero valent iron (nZVI) in unsaturated porous media was investigated. Foams generated using surfactant sodium lauryl ether sulfate (SLES) showed excellent ability to carry nZVI. SLES and nZVI concentrations in the foaming solutions did not affect the percentages of nZVI concentrations in foams relative to nZVI concentrations in the solutions. When foams carrying nZVI were injected through the unsaturated columns, the fractions of nZVI exiting the column were much higher than those when nZVI was injected in liquid. The enhanced nZVI transport implies that foam delivery could significantly increase the radius of influence of injected nZVI. The type and concentrations of surfactants and the influent nZVI concentrations did not noticeably affect nZVI transport during foam delivery. In contrast, nZVI retention increased considerably as the grain size of porous media decreased. Oxidation of foam-delivered nZVI due to oxygen diffusion into unsaturated porous media was visually examined using a flow cell. It was demonstrated that if foams are injected to cover a deep vadose zone layer, oxidation would only cause a small fraction of foam-delivered nZVI to be oxidized before it reacts with contaminants.

Ding, Yuanzhao↗

An isocenter detection and verification device for use in proton therapy

We developed a new device for isocenter detection and verification for use in proton therapy. This device can be used to confirm the isocenters of a room laser, a digital radiography system, and a rotational gantry. Agreement between the isocenters of a room laser and a digital radiography system was examined visually. We used the star-shots method for detecting and verifying the rotational gantry isocenter. The gafchromic film could be irradiated with this method using a 2 mm slitted 200 MeV proton beam. The isocenters of a room laser and digital radiography system were in good agreement. The size distribution of the isocenter by the star-shots method was <2 mm, which is the value recommended by the American Association of Physicists in Medicine Task Group 142. This new device can be used to evaluate comprehensive isocenter detection and verification for related equipment. Subsequent checking using this new device will decrease the uncertainty in measuring an isocenter. When using this device, the working time was significantly reduced to about 30 min, including preparation. These measurements should be useful for high accuracy daily treatments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Candidate Cell and Matrix Interaction Domains on the Collagen Fibril, the Predominant Protein of Vertebrates

Type I collagen, the predominant protein of vertebrates, polymerizes with type III and V collagens and non-collagenous molecules into large cable-like fibrils, yet how the fibril interacts with cells and other binding partners remains poorly understood. To help reveal insights into the collagen structure-function relationship, a data base was assembled including hundreds of type I collagen ligand binding sites and mutations on a two-dimensional model of the fibril. Visual examination of the distribution of functional sites, and statistical analysis of mutation distributions on the fibril suggest it is organized into two domains. The 'cell interaction domain' is proposed to regulate dynamic aspects of collagen biology, including integrin-mediated cell interactions and fibril remodeling. The 'matrix interaction domain' may assume a structural role, mediating collagen cross-linking, proteoglycan interactions, and tissue mineralization. Molecular modeling was used to superimpose the positions of functional sites and mutations from the two-dimensional fibril map onto a three-dimensional x-ray diffraction structure of the collagen microfibril in situ, indicating the existence of domains in the native fibril. Sequence searches revealed that major fibril domain elements are conserved in type I collagens through evolution and in the type II/XI collagen fibril predominant in cartilage. Moreover, the fibril domain model provides potential insights into the genotype-phenotype relationship for several classes of human connective tissue diseases, mechanisms of integrin clustering by fibrils, the polarity of fibril assembly, heterotypic fibril function, and connective tissue pathology in diabetes and aging.

59 BASIC BIOLOGICAL SCIENCES↗

AN ENHANCED SPECTROSCOPIC CENSUS OF THE ORION NEBULA CLUSTER

We report new spectral types or spectral classification constraints for over 600 stars in the Orion Nebula Cluster (ONC) based on medium resolution (R ≈ 1500-2000) red optical spectra acquired using the Palomar 200'' and Kitt Peak 3.5 m telescopes. Spectral types were initially estimated for F, G, and early K stars from atomic line indices while for late K and M stars, which constitute the majority of our sample, indices involving TiO and VO bands were used. To ensure proper classification, particularly for reddened, veiled, or nebula-contaminated stars, all spectra were then visually examined for type verification or refinement. We provide an updated spectral type table that supersedes previous work, increasing the percentage of optically visible ONC stars with spectral type information from 68% to 90%. However, for many objects, repeated observations have failed to yield spectral types primarily due to the challenges of adequate sky subtraction against a bright and spatially variable nebular background. The scatter between our new and our previously determined spectral types is approximately two spectral sub-classes. We also compare our grating spectroscopy results with classification based on narrow-band TiO filter photometry, finding similar scatter. While the challenges of working in the ONC may explain much of the spread, we highlight several stars showing significant and unexplained bona fide spectral variations in observations taken several years apart; these and similar cases could be due to a combination of accretion and extinction changes. Finally, nearly 20% of ONC stars exhibit obvious Ca II triplet emission indicative of strong accretion.

79 ASTRONOMY AND ASTROPHYSICS↗

A search for globular clusters in more remote areas around M31 and M33 II

Using the Sloan Digital Sky Survey (SDSS), ∼900 deg{sup 2} of the sky surrounding M31 and M33 have been searched for globular clusters (GCs) that through galaxy interaction have become unbound from their parent systems and M31 (hence, intergalactic globular clusters, IGCs). This search reached a maximum of ∼500 kpc in projected galactocentric distance (R {sub gc}) from M31. Visual examination of 283,871 SDSS cutout images and of 1143 fits images yielded 320 candidates. This sample was reduced to six GCs and one likely candidate by excluding galaxies on the basis of combinations of their optical, ultraviolet, and infrared colors from the SDSS, the Galaxy Evolution Explorer satellite, and the Wide-field Infrared Survey Explorer satellite, as well as their photometric redshifts from the SDSS. Since these seven objects have 14 kpc ≤ R {sub gc} ≤ 137 kpc, they are more likely to be GCs in the halo of M31 than IGCs. They are all 'classical' as opposed to 'extended' GCs, and they provide further evidence that the remote halo of M31 (R {sub gc} ≥ 50 kpc) contains more GCs of all types and, in particular, far more 'classical' ones than the remote halo of the Milky Way.

79 ASTRONOMY AND ASTROPHYSICS↗

A search for intergalactic globular clusters in the local group

The whole Sloan Digital Sky Survey (SDSS, 14,555 deg{sup 2}) has been searched for intergalactic globular clusters (IGCs) in the Local Group (LG). Using optical, infrared, and ultraviolet photometric selection criteria and photometric redshifts, the 2.1×10{sup 8} objects in the SDSS Galaxy Catalog were reduced to only 183,791 brighter than r{sub 0}=19 that might be GCs. Visual examination of their SDSS images recovered 84% of the confirmed GCs in M31 and M33 and yielded 17 new GC candidates, 5 of them of high confidence, which we could confirm as GCs in MegaPrime images from the Canada–France–Hawaii Telescope. These 5 GCs are within M31's halo, but the other 12 candidates are not close to LG galaxies or galaxies within 3 Mpc of the LG. Even though this search covers only one-third of the sky and some GCs could have been missed, it suggests that the LG does not contain a large population of IGCs more luminous than M{sub V}∼−6. In the direction of the M81 Group, the search yielded five candidate GCs, probable members of that group.

79 ASTRONOMY AND ASTROPHYSICS↗

A SEARCH FOR BINARY ACTIVE GALACTIC NUCLEI: DOUBLE-PEAKED [O III] AGNs IN THE SLOAN DIGITAL SKY SURVEY

We present active galactic nuclei (AGNs) from the Sloan Digital Sky Survey (SDSS) having double-peaked profiles of [O III]{lambda}{lambda}5007, 4959 and other narrow emission lines, motivated by the prospect of finding candidate binary AGNs. These objects were identified by means of a visual examination of 21,592 quasars at z < 0.7 in SDSS Data Release 7 (DR7). Of the spectra with adequate signal-to-noise, 148 spectra exhibit a double-peaked [O III] profile. Of these, 86 are Type 1 AGNs and 62 are Type 2 AGNs. Only two give the appearance of possibly being optically resolved double AGNs in the SDSS images, but many show close companions or signs of recent interaction. Radio-detected quasars are three times more likely to exhibit a double-peaked [O III] profile than quasars with no detected radio flux, suggesting a role for jet interactions in producing the double-peaked profiles. Of the 66 broad-line (Type 1) AGNs that are undetected in the FIRST survey, 0.9% show double-peaked [O III] profiles. We discuss statistical tests of the nature of the double-peaked objects. Further study is needed to determine which of them are binary AGNs rather than disturbed narrow line regions, and how many additional binaries may remain undetected because of insufficient line-of-sight velocity splitting. Previous studies indicate that 0.1% of SDSS quasars are spatially resolved binaries, with typical spacings of {approx}10-100 kpc. If a substantial fraction of the double-peaked objects are indeed binaries, then our results imply that binaries occur more frequently at smaller separations (<10 kpc). This suggests that simultaneous fueling of both black holes is more common as the binary orbit decays through these spacings.

79 ASTRONOMY AND ASTROPHYSICS↗

HIGH-RESOLUTION SIMULATIONS OF THE REIONIZATION OF AN ISOLATED MILKY WAY-M31 GALAXY PAIR

We present the results of a set of numerical simulations aimed at studying reionization at the galactic scale. We use a high-resolution realization of the formation of the Milky Way (MW)-M31 system to simulate the reionization of the Local Group. The reionization calculation was performed with the post-processing radiative transfer code ATON and the underlying cosmological simulation was performed as part of the CLUES project (http://www.clues-project.org). We vary the source models to bracket the range of source properties used in the literature. We investigate the structure and propagation of the galactic ionization fronts by a visual examination of our reionization maps. Within the progenitors, we find that reionization is patchy and proceeds locally inside-out. The process becomes patchier with decreasing source photon output. It is generally dominated by one major H II region and one to four additional isolated smaller bubbles, which eventually overlap. Higher emissivity results in faster and earlier local reionization. In all models, the reionization of the MW and M31 are similar in duration, i.e., between 203 Myr and 22 Myr depending on the source model, placing their z{sub reion} between 8.4 and 13.7. In all models except the most extreme, the MW and M31 progenitors reionize internally, ignoring each other despite being relatively close to each other, even during the epoch of reionization. Only in the case of strong supernova feedback suppressing star formation in halos less massive than 10{sup 9} M{sub ☉}, and using our highest emissivity, do we find that the MW is reionized by M31.

79 ASTRONOMY AND ASTROPHYSICS↗

Island of misfit tortoises: waif gopher tortoise health assessment following translocation

Translocation, the intentional movement of animals from one location to another, is a common management practice for the gopher tortoise (Gopherus polyphemus). Although the inadvertent spread of pathogens is a concern with any translocation effort, waif tortoises—individuals that have been collected illegally, injured and rehabilitated or have unknown origins—are generally excluded from translocation efforts due to heightened concerns of introducing pathogens and subsequent disease to naïve populations. However, repurposing these long-lived animals for species recovery is desirable when feasible, and introducing waif tortoises may bolster small populations facing extirpation. The objective of this study was to assess the health of waif tortoises experimentally released at an isolated preserve in Aiken County, SC, USA. Our assessments included visual examination, screening for 14 pathogens using conventional or quantitative polymerase chain reaction (qPCR) and haematological evaluation. Of the 143 individuals assessed in 2017 and 2018, most individuals (76%; n = 109 of 143) had no overt clinical evidence of disease and, when observed, clinical findings were mild. In both years, we detected two known tortoise pathogens, Mycoplasma agassizii and Mycoplasma testudineum, at a prevalence of 10.2–13.9% and 0.0–0.8%, respectively. Additionally, we found emydid Mycoplasma, a bacterium commonly found in box turtles (Terrapene spp.), in a single tortoise that showed no clinical evidence of infection. The presence of nasal discharge was an important, but imperfect, predictor of Mycoplasma spp. infection in translocated tortoises. Hemogram data were comparable with wild populations. Our study is the first comprehensive effort to assess pathogen prevalence and hemogram data of waif gopher tortoises following translocation. Although caution is warranted and pathogen screening necessary, waif tortoises may be an important resource for establishing or augmenting isolated populations when potential health risks can be managed.

60 APPLIED LIFE SCIENCES↗

Pre- and post-processing of cluster galaxies out to 5 × R 200: the extreme case of A2670

ABSTRACT We study galaxy interactions in the large-scale environment around A2670, a massive (M200 = $8.5 \pm 1.2~\times 10^{14} \, \mathrm{{M}_{\odot }}$) and interacting galaxy cluster at z = 0.0763. We first characterize the environment of the cluster out to 5× R200 and find a wealth of substructures, including the main cluster core, a large infalling group, and several other substructures. To study the impact of these substructures (pre-processing) and their accretion into the main cluster (post-processing) on the member galaxies, we visually examined optical images to look for signatures indicative of gravitational or hydrodynamical interactions. We find that ∼21 per cent of the cluster galaxies have clear signs of disturbances, with most of those (∼60 per cent) likely being disturbed by ram pressure. The number of ram-pressure stripping candidates found (101) in A2670 is the largest to date for a single system, and while they are more common in the cluster core, they can be found even at >4 × R200, confirming cluster influence out to large radii. In support of a pre-processing scenario, most of the disturbed galaxies follow the substructures found, with the richest structures having more disturbed galaxies. Post-processing also seems plausible, as many galaxy–galaxy mergers are seen near the cluster core, which is not expected in relaxed clusters. In addition, there is a comparable fraction of disturbed galaxies in and outside substructures. Overall, our results highlight the complex interplay of gas stripping and gravitational interactions in actively assembling clusters up to 5 × R200, motivating wide-area studies in larger cluster samples.

Astronomy & Astrophysics↗

Counter-top search for macroscopic dark matter

A number of dark matter candidates have been discussed that are macroscopic, of approximately nuclear density, and scatter ordinary matter essentially elastically with approximately their geometric cross section. A wide range of mass and geometric cross section is still unprobed for these “macros.” Macros passing through rock would melt the material in cylinders surrounding their long nearly straight trajectories. Once cooled, the resolidified rock would be easily distinguishable from its surroundings. In this paper we discuss how, by visually examining ordinary slabs of rock such as are widely available commercially for kitchen countertops, one could probe an interesting segment of the open macro parameter space.

79 ASTRONOMY AND ASTROPHYSICS↗

Objective models of compressed breast shapes undergoing mammography

Purpose: To develop models of compressed breasts undergoing mammography based on objective analysis, that are capable of accurately representing breast shapes in acquired clinical images and generating new, clinically realistic shapes. Methods: An automated edge detection algorithm was used to catalogue the breast shapes of clinically acquired cranio-caudal (CC) and medio-lateral oblique (MLO) view mammograms from a large database of digital mammography images. Principal component analysis (PCA) was performed on these shapes to reduce the information contained within the shapes to a small number of linearly independent variables. The breast shape models, one of each view, were developed from the identified principal components, and their ability to reproduce the shape of breasts from an independent set of mammograms not used in the PCA, was assessed both visually and quantitatively by calculating the average distance error (ADE). Results: The PCA breast shape models of the CC and MLO mammographic views based on six principal components, in which 99.2% and 98.0%, respectively, of the total variance of the dataset is contained, were found to be able to reproduce breast shapes with strong fidelity (CC view mean ADE = 0.90 mm, MLO view mean ADE = 1.43 mm) and to generate new clinically realistic shapes. The PCA models based on fewer principal components were also successful, but to a lesser degree, as the two-component model exhibited a mean ADE = 2.99 mm for the CC view, and a mean ADE = 4.63 mm for the MLO view. The four-component models exhibited a mean ADE = 1.47 mm for the CC view and a mean ADE = 2.14 mm for the MLO view. Paired t-tests of the ADE values of each image between models showed that these differences were statistically significant (max p-value = 0.0247). Visual examination of modeled breast shapes confirmed these results. Histograms of the PCA parameters associated with the six principal components were fitted with Gaussian distributions. The six-component model was also used to generate CC and MLO view mammogram breast shapes, using the mean PCA parameter values of these distributions and randomly generated values based on the fitted Gaussian distributions, which resemble clinically encountered breasts. A spreadsheet with the data necessary to apply this model is provided as the supplementary material. Conclusions: Our PCA models of breast shapes in both mammographic views successfully reproduce analyzed breast shapes and generate new clinically relevant shapes. This work can aid in research applications which incorporate breast shape modeling, such as x-ray scatter correction, dosimetry, and image registration.

60 APPLIED LIFE SCIENCES↗

SU-E-J-126: Respiratory Gating Quality Assurance: A Simple Method to Achieve Millisecond Temporal Resolution

Purpose: Low temporal latency between a gating on/off signal and a linac beam on/off during respiratory gating is critical for patient safety. Although, a measurement of temporal lag is recommended by AAPM Task Group 142 for commissioning and annual quality assurance, there currently exists no published method. Here we describe a simple, inexpensive, and reliable method to precisely measure gating lag at millisecond resolutions. Methods: A Varian Real-time Position Management™ (RPM) gating simulator with rotating disk was modified with a resistive flex sensor (Spectra Symbol) attached to the gating box platform. A photon diode was placed at machine isocenter. Output signals of the flex sensor and diode were monitored with a multichannel oscilloscope (Tektronix™ DPO3014). Qualitative inspection of the gating window/beam on synchronicity were made by setting the linac to beam on/off at end-expiration, and the oscilloscope's temporal window to 100 ms to visually examine if the on/off timing was within the recommended 100-ms tolerance. Quantitative measurements were made by saving the signal traces and analyzing in MatLab™. The on and off of the beam signal were located and compared to the expected gating window (e.g. 40% to 60%). Four gating cycles were measured and compared. Results: On a Varian TrueBeam™ STx linac with RPM gating software, the average difference in synchronicity at beam on and off for four cycles was 14 ms (3 to 30 ms) and 11 ms (2 to 32 ms), respectively. For a Varian Clinac™ 21EX the average difference at beam on and off was 127 ms (122 to 133 ms) and 46 ms (42 to 49 ms), respectively. The uncertainty in the synchrony difference was estimated at ±6 ms. Conclusion: This new gating QA method is easy to implement and allows for fast qualitative inspection and quantitative measurements for commissioning and TG-142 annual QA measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computerized analysis of coronary artery disease: Performance evaluation of segmentation and tracking of coronary arteries in CT angiograms

Purpose: The authors are developing a computer-aided detection system to assist radiologists in analysis of coronary artery disease in coronary CT angiograms (cCTA). This study evaluated the accuracy of the authors’ coronary artery segmentation and tracking method which are the essential steps to define the search space for the detection of atherosclerotic plaques. Methods: The heart region in cCTA is segmented and the vascular structures are enhanced using the authors’ multiscale coronary artery response (MSCAR) method that performed 3D multiscale filtering and analysis of the eigenvalues of Hessian matrices. Starting from seed points at the origins of the left and right coronary arteries, a 3D rolling balloon region growing (RBG) method that adapts to the local vessel size segmented and tracked each of the coronary arteries and identifies the branches along the tracked vessels. The branches are queued and subsequently tracked until the queue is exhausted. With Institutional Review Board approval, 62 cCTA were collected retrospectively from the authors’ patient files. Three experienced cardiothoracic radiologists manually tracked and marked center points of the coronary arteries as reference standard following the 17-segment model that includes clinically significant coronary arteries. Two radiologists visually examined the computer-segmented vessels and marked the mistakenly tracked veins and noisy structures as false positives (FPs). For the 62 cases, the radiologists marked a total of 10191 center points on 865 visible coronary artery segments. Results: The computer-segmented vessels overlapped with 83.6% (8520/10191) of the center points. Relative to the 865 radiologist-marked segments, the sensitivity reached 91.9% (795/865) if a true positive is defined as a computer-segmented vessel that overlapped with at least 10% of the reference center points marked on the segment. When the overlap threshold is increased to 50% and 100%, the sensitivities were 86.2% and 53.4%, respectively. For the 62 test cases, a total of 55 FPs were identified by radiologist in 23 of the cases. Conclusions: The authors’ MSCAR-RBG method achieved high sensitivity for coronary artery segmentation and tracking. Studies are underway to further improve the accuracy for the arterial segments affected by motion artifacts, severe calcified and noncalcified soft plaques, and to reduce the false tracking of the veins and other noisy structures. Methods are also being developed to detect coronary artery disease along the tracked vessels.

60 APPLIED LIFE SCIENCES↗

Position tracking of moving liver lesion based on real-time registration between 2D ultrasound and 3D preoperative images

Purpose: Registration between 2D ultrasound (US) and 3D preoperative magnetic resonance (MR) (or computed tomography, CT) images has been studied recently for US-guided intervention. However, the existing techniques have some limits, either in the registration speed or the performance. The purpose of this work is to develop a real-time and fully automatic registration system between two intermodal images of the liver, and subsequently an indirect lesion positioning/tracking algorithm based on the registration result, for image-guided interventions. Methods: The proposed position tracking system consists of three stages. In the preoperative stage, the authors acquire several 3D preoperative MR (or CT) images at different respiratory phases. Based on the transformations obtained from nonrigid registration of the acquired 3D images, they then generate a 4D preoperative image along the respiratory phase. In the intraoperative preparatory stage, they properly attach a 3D US transducer to the patient’s body and fix its pose using a holding mechanism. They then acquire a couple of respiratory-controlled 3D US images. Via the rigid registration of these US images to the 3D preoperative images in the 4D image, the pose information of the fixed-pose 3D US transducer is determined with respect to the preoperative image coordinates. As feature(s) to use for the rigid registration, they may choose either internal liver vessels or the inferior vena cava. Since the latter is especially useful in patients with a diffuse liver disease, the authors newly propose using it. In the intraoperative real-time stage, they acquire 2D US images in real-time from the fixed-pose transducer. For each US image, they select candidates for its corresponding 2D preoperative slice from the 4D preoperative MR (or CT) image, based on the predetermined pose information of the transducer. The correct corresponding image is then found among those candidates via real-time 2D registration based on a gradient-based similarity measure. Finally, if needed, they obtain the position information of the liver lesion using the 3D preoperative image to which the registered 2D preoperative slice belongs. Results: The proposed method was applied to 23 clinical datasets and quantitative evaluations were conducted. With the exception of one clinical dataset that included US images of extremely low quality, 22 datasets of various liver status were successfully applied in the evaluation. Experimental results showed that the registration error between the anatomical features of US and preoperative MR images is less than 3 mm on average. The lesion tracking error was also found to be less than 5 mm at maximum. Conclusions: A new system has been proposed for real-time registration between 2D US and successive multiple 3D preoperative MR/CT images of the liver and was applied for indirect lesion tracking for image-guided intervention. The system is fully automatic and robust even with images that had low quality due to patient status. Through visual examinations and quantitative evaluations, it was verified that the proposed system can provide high lesion tracking accuracy as well as high registration accuracy, at performance levels which were acceptable for various clinical applications.

60 APPLIED LIFE SCIENCES↗

Isolation and characterization of two cellulose morphology mutants of Gluconacetobacter hansenii ATCC23769 producing cellulose with lower crystallinity

Gluconacetobacter hansenii , a Gram-negative bacterium, produces and secrets highly crystalline cellulose into growth medium, and has long been used as a model system for studying cellulose synthesis in higher plants. Cellulose synthesis involves the formation of β-1,4 glucan chains via the polymerization of glucose units by a multi-enzyme cellulose synthase complex (CSC). These glucan chains assemble into ordered structures including crystalline microfibrils. AcsA is the catalytic subunit of the cellulose synthase enzymes in the CSC, and AcsC is required for the secretion of cellulose. However, little is known about other proteins required for the assembly of crystalline cellulose. To address this question, we visually examined cellulose pellicles formed in growth media of 763 individual colonies of G. hansenii generated via Tn5 transposon insertion mutagenesis, and identified 85 that produced cellulose with altered morphologies. X-ray diffraction analysis of these 85 mutants identified two that produced cellulose with significantly lower crystallinity than wild type. The gene disrupted in one of these two mutants encoded a lysine decarboxylase and that in the other encoded an alanine racemase. Solid-state NMR analysis revealed that cellulose produced by these two mutants contained increased amounts of non-crystalline cellulose and monosaccharides associated with non-cellulosic polysaccharides as compared to the wild type. Monosaccharide analysis detected higher percentages of galactose and mannose in cellulose produced by both mutants. Field emission scanning electron microscopy showed that cellulose produced by the mutants was unevenly distributed, with some regions appearing to contain deposition of non-cellulosic polysaccharides; however, the width of the ribbon was comparable to that of normal cellulose. As both lysine decarboxylase and alanine racemase are required for the integrity of peptidoglycan, we propose a model for the role of peptidoglycan in the assembly of crystalline cellulose.

59 BASIC BIOLOGICAL SCIENCES↗

Ranchero Armature Test LA-43-CT-2: PBXN-110 Explosive with no smoothing layer. Lower Slobovia, 6/13/13

This test, documented as LA-43-CT-2, was performed to verify calculations which indicate that the smoothing layer employed for Ranchero Armatures is not required when the slapper point spacing is 18 mm (“On the efficacy of an acrylic layer in the Ranchero armature,” Bob Watt, published in “Ranchero Status Report” LA-14463). [Naming this test –CT-2 acknowledges the previous test performed during 1/11 as the initial test in the series, and we will refer to that test as LA-43-CT-1 in the future.] In addition, higher velocity is achieved when the volume occupied by the smoother is replaced by HE. Two framing cameras were used on the shot, and a 20 point PDV array was fielded to ascertain armature performance in specific conditions. The conclusions are that the armature is smooth enough, and the terminal velocity is increased from ~3.1 mm/μs to ~3.3 mm/μs. The armature tested had casting voids in the HE that were observed in pre-test inspections, and were expected to cause ruptures. (See Appendix 3 of the Ranchero Status Report.) Such “blowouts” were observed in all three locations identified in pre-shot inspection. In addition, ruptures occurred in locations having no pre-shot indication of a problem. These unpredicted blowouts have a difference in appearance from those typically seen. Further visual examination of the inspection radiographs do not reveal the cause, and that is a serious concern for future efforts with such castings. A path forward will include attempting to digitize the inspection x-rays for the charge tested, to see if the cause of the “new” ruptures can be found via computer enhancement. In addition, there are two additional armatures from the same casting lot, and these might also be tested to see if there is some problem with the HE or the armature material in this batch. For now, this plan is on hold, pending the outcome of tests and cost estimates related to using PBX-9501 in place of the PBXN-110. Casting issues would be eliminated in such configurations.

42 ENGINEERING↗

Microbial Activity and Precipitation at Solution-Solution Mixing Zones in Porous Media -- Subsurface Biogeochemical Research

The goal for this research was to understand how best to add compounds to receptive microbial communities in porous media in order to achieve optimal calcite precipitation in a volumetrically significant space and to understand the physiological health of the cells that are responsible for the calcite precipitation. The specific objectives were to: (1) develop better tools for visually examining biofilms in porous media and calcium carbonate precipitation being mediated by microbes in porous media, and (2) demonstrate the effectiveness of using that tool within a flow cell model system.

54 ENVIRONMENTAL SCIENCES↗