At least 73 records · Page 4

The Oxygen and Volatile Extraction Node (OVEN) Subsystem for Resource Prospector

The OVEN (Oxygen and Volatile Extraction Node) Subsystem is part of the RESOLVE (Regolith and Environment Science & Oxygen and Lunar Volatile Extraction) Payload, whose main objective is to verify the presence of water and other volatiles on the lunar surface. The RESOLVE payload is scheduled to fly to the moon as part of the Resource Prospector (RP) in 2019. The OVEN Subsystem accepts regolith (soil) and evolves the volatiles contained in the sample by heating the segment to a temperature of at least 150oC for volatile analysis and as high as 900oC for hydrogen reduction. In general, a regolith segment is deposited into a crucible; the crucible is heated and evolved gases flow to a gas analyzer.

Paz, Aaron↗

Resource Prospector Instrumentation for Lunar Volatiles Prospecting, Sample Acquisition and Processing

Data gathered from lunar missions within the last two decades have significantly enhanced our understanding of the volatile resources available on the lunar surface, specifically focusing on the polar regions. Several orbiting missions such as Clementine and Lunar Prospector have suggested the presence of volatile ices and enhanced hydrogen concentrations in the permanently shadowed regions of the moon. The Lunar Crater Observation and Sensing Satellite (LCROSS) mission was the first to provide direct measurement of water ice in a permanently shadowed region. These missions with other orbiting assets have laid the groundwork for the next step in the exploration of the lunar surface; providing ground truth data of the volatiles by mapping the distribution and processing lunar regolith for resource extraction. This next step is the robotic mission Resource Prospector (RP).Resource Prospector is a lunar mission to investigate strategic knowledge gaps (SKGs) for in-situ resource utilization (ISRU). The mission is proposed to land in the lunar south pole near a permanently shadowed crater. The landing site will be determined by the science team with input from broader international community as being near traversable landscape that has a high potential of containing elevated concentrations of volatiles such as water while maximizing mission duration. A rover will host the Regolith Environment Science and Oxygen Lunar Volatile Extraction (RESOLVE) payload for resource mapping and processing. The science instruments on the payload include a 1-meter drill, neutron spectrometer, a near infrared spectrometer, an operations camera, and a reactor with a gas chromatograph-mass spectrometer for volatile analysis.

Lunar Crater↗

Design Process of a Pressure Transducer Vibration Fixture

This paper details the iterative design cycle of a fixture used to mount two types of pressure transducers for vibration testing which allows for functional testing without the removal of the transducers. The objective of the fixture is to prove that the pressure transducers can survive vibrations induced during launch. This would increase the Technology Readiness Level of the pressure transducers which is a requirement for the Lunar Advanced Volatile Analysis subsystem preliminary design review. During the design process, additive manufacturing is considered as a manufacturing method of the fixture as a way to investigate the use of additive manufacturing for the final flight version of the Fluid Sub System manifold. It is ultimately shown that the added ability to perform functional testing and optimization for additive manufacturing made the fixture less than ideal for vibration testing. It is determined that the best option is to design and manufacture a traditional vibration fixture without the ability to perform functional testing of components while attached and a separate part to investigate the application of additive manufacturing to the Fluid Subsystem manifold.

Gilstrap, Andrew↗

Isotopic Compositions of Noble Gases and Nitrogen in the Ryugu Samples Returned by Hayabusa2

In December 2014, the hayabusa2 spacecraft launched to visit the C-type asteroid (162173) Ryugu to bring back surface and subsurface materials to the Earth. The spacecraft arrived at Ryugu on June 27, 2018, and subsequently carried out two touchdowns (TDs) and sample collections. The 1st TD was carried out and collected surface samples, while the 2nd TD was done to collect the impact melt ejecta near the artificial crater made by the small carry-on Impactor operation in April 2019. Samples collected during the 1st and 2nd TDs were stored in Chamber A and C of the Hayabusa2 sample catcher, respectively. Our principal objective is to quantify the indigenous compositions of the Ryugu samples with as little terrestrial contamination as possible. Here we report the isotopic ratios and concentrations of noble gases and nitrogen in the Ryugu samples allocated to the Hayabusa2-initial-analysis-volatile team.

noble gas↗

The Evolution of Volatile Memory Forensics

The collection and analysis of volatile memory is a vibrant area of research in the cybersecurity community. The ever-evolving and growing threat landscape is trending towards fileless malware, which avoids traditional detection but can be found by examining a system’s random access memory (RAM). Additionally, volatile memory analysis offers great insight into other malicious vectors. It contains fragments of encrypted files’ contents, as well as lists of running processes, imported modules, and network connections, all of which are difficult or impossible to extract from the file system. For these compelling reasons, recent research efforts have focused on the collection of memory snapshots and methods to analyze them for the presence of malware. However, to the best of our knowledge, no current reviews or surveys exist that systematize the research on both memory acquisition and analysis. We fill that gap with this novel survey by exploring the state-of-the-art tools and techniques for volatile memory acquisition and analysis for malware identification. For memory acquisition methods, we explore the trade-offs many techniques make between snapshot quality, performance overhead, and security. For memory analysis, we examined the traditional forensic methods used, including signature-based methods, dynamic methods performed in a sandbox environment, as well as machine learning-based approaches. We summarize the currently available tools, and suggest areas for more research.

Nyholm, Hannah↗

Monitoring systems for evaluation of terrestrial contamination in a lunar sample transfer facility

The lunar sample transfer facility used consists of two tandem glove boxes and an entrance vacuum antechamber. Monitoring systems were used to evaluate the contamination levels of water, permanent gases, and lower volatility organic compounds in the glove box atmosphere. The experimental procedures are considered, taking into account the glove box atmosphere, aspects of volatile gas analysis, and lower volatility organic contaminants. The value of high resolution mass spectrometry in the monitoring scheme is illustrated with the aid of an example.

Wszolek, P. C.↗

Miniature triaxial metastable ionization detector for gas chromatographic trace analysis of extraterrestrial volatiles

The present investigation is concerned with a miniature metastable ionization detector featuring an unconventional electrode configuration, whose performance characteristics parallel those of traditional design. The ionization detector is to be incorporated in a flight gas chromatograph (GC) for use in the Space Shuttle. The design of the detector is discussed, taking into account studies which verified the sensitivity of the detector. The triaxial design of the detector is compared with a flat-plate style. The obtained results show that the principal goal of developing a miniature, highly sensitive ionization detector for flight applications was achieved. Improved fabrication techniques will utilize glass-to-metal seals and brazing procedures.

Woeller, F. H.↗

A Helium GC/IMS for the Analysis of Extraterrestrial Volatiles in Exobiology Flight Experiments

For exobiology experiments on board spacecraft or space probes, a wide range of chemical species often must be detected and identified. The limited amount of power and space available for flight instruments severely limits the number of instruments that can be flown on any given mission. It is important then, that these experiments utilize instrumentation with universal response, so that all species of interest can be analyzed. Instrumentation to fulfill the analytical requirements of exobiology experiments has been developed utilizing Gas Chromatography - Ion Mobility Spectrometry. The Gas Chromatograph (GC) combines columns developed specifically for the complex mixtures anticipated with highly sensitive Metastable Ionization Detectors (a type of Helium Ionization Detector). To satisfy the limitations placed on resources, the Ion Mobility Spectrometer (IMS) uses the same ultra high purity helium as the GC. This GC-MS provides the analytical capability to fulfill a wide range of exobiology flight experiment applications and has been included on a proposed Discovery Mission and proposals for both Lander and Orbiter of the European Space Agency's Rosetta Comet Mission. A data base of helium IMS spectra is now being built for these future applications.

Kojiro, Daniel R.↗

Results for the first quarter calendar year 2017 tank 50H salt solution sample

In this memorandum, the chemical and radionuclide contaminant results from the First Quarter Calendar Year 2017 (CY17) sample of Tank 50H salt solution are presented in tabulated form. The First Quarter CY17 Tank 50H samples [a 200 mL sample obtained 6” below the surface (HTF-50-17-7) and a 1 L sample obtained 66” from the tank bottom (HTF-50-17-8)] were obtained on January 15, 2017 and received at Savannah River National Laboratory (SRNL) on January 16, 2017. Prior to obtaining the samples from Tank 50H, a single pump was run at least 4.4 hours and the samples were pulled immediately after pump shut down. All volatile organic analysis (VOA) and semi-volatile organic analysis (SVOA) were performed on the surface sample and all other analyses were performed on the variable depth sample. The information from this characterization will be used by Savannah River Remediation (SRR) for the transfer of aqueous waste from Tank 50H to the Saltstone Production Facility, where the waste will be treated and disposed of in the Saltstone Disposal Facility. This memorandum compares results, where applicable, to Saltstone Waste Acceptance Criteria (WAC) limits and targets. The chemical and radionuclide contaminant results from the characterization of the First Quarter CY17 sampling of Tank 50H were requested by SRR personnel and details of the testing are presented in the SRNL Task Technical and Quality Assurance Plan (TTQAP). This memorandum is part of Deliverable 2 from SRR request. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals will be documented at a later time per the TTQAP for the Tank 50H saltstone task.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results for the First Quarter Calendar Year 2017 Tank 50H Salt Solution Sample

In this memorandum, the chemical and radionuclide contaminant results from the First Quarter Calendar Year 2017 (CY17) sample of Tank 50 H salt solution are presented in tabulated form. The First Quarter CY17 Tank 50H samples [a 200 mL sample obtained 6” below the surface (HTF-50-17-7) and a 1 L sample obtained 66” from the tank bottom (HTF-50-17-8)] were obtained on January 15, 2017 and received at Savannah River National Laboratory (SRNL) on January 16, 2017. Prior to obtaining the samples from Tank 50H, a single pump was run at least 4.4 hours and the samples were pulled immediately after pump shut down. All volatile organic analysis (VOA) and semi-volatile organic analysis (SVOA) were performed on the surface sample and all other analyses were performed on the variable depth sample. The information from this characterization will be used by Savannah River Remediation (SRR) for the transfer of aqueous waste from Tank 50H to the Saltstone Production Facility, where the waste will be treated and disposed of in the Saltstone Disposal Facility.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results for the Third Quarter Calendar Year 2017 Tank 50 Salt Solution Sample

In this memorandum, the chemical and radionuclide contaminant results from the Third Quarter Calendar Year 2017 (CY17) sample of Tank 50 salt solution are presented in tabulated form. The Third Quarter CY17 Tank 50 samples [a 200 mL sample obtained 6” below the surface (HTF-50-17-62) and a 1 L sample obtained 66” from the tank bottom (HTF-50-17-63)] were obtained on July 17, 2017 and received at Savannah River National Laboratory (SRNL) on July 17, 2017. Prior to obtaining the samples from Tank 50, a single pump was run at least 4.4 hours and the samples were pulled immediately after pump shut down. All volatile organic analysis (VOA) and semi-volatile organic analysis (SVOA) were performed on the surface sample and all other analyses were performed on the variable depth sample. The information from this characterization will be used by Savannah River Remediation (SRR) for the transfer of aqueous waste from Tank 50 to the Saltstone Production Facility, where the waste will be treated and disposed of in the Saltstone Disposal Facility.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MetricForensics: A Multi-Level Approach for Mining Volatile Graphs

Advances in data collection and storage capacity have made it increasingly possible to collect highly volatile graph data for analysis. Existing graph analysis techniques are not appropriate for such data, especially in cases where streaming or near-real-time results are required. An example that has drawn significant research interest is the cyber-security domain, where internet communication traces are collected and real-time discovery of events, behaviors, patterns and anomalies is desired. We propose MetricForensics, a scalable framework for analysis of volatile graphs. MetricForensics combines a multi-level “drill down" approach, a collection of user-selected graph metrics and a collection of analysis techniques. At each successive level, more sophisticated metrics are computed and the graph is viewed at a finer temporal resolution. In this way, MetricForensics scales to highly volatile graphs by only allocating resources for computationally expensive analysis when an interesting event is discovered at a coarser resolution first. We test MetricForensics on three real-world graphs: an enterprise IP trace, a trace of legitimate and malicious network traffic from a research institution, and the MIT Reality Mining proximity sensor data. Our largest graph has »3M vertices and »32M edges, spanning 4:5 days. The results demonstrate the scalability and capability of MetricForensics in analyzing volatile graphs; and highlight four novel phenomena in such graphs: elbows, broken correlations, prolonged spikes, and strange stars.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

IMPROVED ANTIFOAM AGENT STUDY END OF YEAR REPORT, EM PROJECT 3.2.3

Antifoam 747 is added to minimize foam produced by process gases and water vapor during chemical processing of sludge in the Defense Waste Processing Facility (DWPF). This allows DWPF to maximize acid addition and evaporation rates to minimize the cycle time in the Chemical Processing Cell (CPC). Improvements in DWPF melt rate due to the addition of bubblers in the melter have resulted in the need for further reductions in cycle time in the CPC. This can only be accomplished with an effective antifoam agent. DWPF production was suspended on March 22, 2011 as the result of a Flammable Gas New Information/(NI) Potential Inadequacy in the Safety Analysis (PISA). The issue was that the DWPF melter offgas flammability strategy did not take into account the H and C in the antifoam, potentially flammable components, in the melter feed. It was also determined the DWPF was using much more antifoam than anticipated due to a combination of longer processing in the CPC due to high Hg, longer processing due to Actinide Removal Process (ARP)/Modular Caustic Side Solvent Extraction Unit (MCU) additions, and adding more antifoam than recommended. The resolution to the PISA involved and assessment of the impact of the antifoam on melter flammability and the implementation of a strategy to control additions within acceptable levels. This led to the need to minimize the use of Antifoam 747 in processing beginning in May 2011. DWPF has had limited success in using Antifoam 747 in caustic processing. Since starting up the ARP facility, the ARP product (similar chemically to caustic sludge) is added to the Sludge Receipt and Adjustment Tank (SRAT) at boiling and evaporated to maintain a constant SRAT volume. Although there is very little offgas generated during caustic boiling, there is a large volume of water vapor produced which can lead to foaming. High additions and more frequent use of antifoam are used to mitigate the foaming during caustic boiling. The result of these three issues above is that DWPF had three antifoam needs in FY2011: (1) Determine the cause of the poor Antifoam 747 performance during caustic boiling; (2) Determine the decomposition products of Antifoam 747 during CPC processing; and (3) Improve the effectiveness of Antifoam 747, in order to minimize the amount used. Testing was completed by Illinois Institute of Technology (IIT) and Savannah River National Laboratory (SRNL) researchers to address these questions. The testing results reported were funded by both DWPF and DOE/EM 31. Both sets of results are reported in this document for completeness. The results of this research are summarized: (1) The cause for the poor Antifoam 747 performance during caustic boiling was the high hydrolysis rate, cleaving the antifoam molecule in two, leading to poor antifoam performance. In testing with pH solutions from 1 to 13, the antifoam degraded quickly at a pH < 4 and pH > 10. As the antifoam decomposed it lost its spreading ability (wetting agent performance), which is crucial to its antifoaming performance. During testing of a caustic sludge simulants, there was more foam in tests with added Antifoam 747 than in tests without added antifoam. (2) Analyses were completed to determine the composition of the two antifoam components and Antifoam 747. In addition, the decomposition products of Antifoam 747 were determined during CPC processing of sludge simulants. The main decomposition products were identified primarily as Long Chain Siloxanes, boiling point > 400 C. Total antifoam recovery was 33% by mass. In a subsequent study, various compounds potentially related to antifoam were found using semi-volatile organic analysis and volatile organic analysis on the hexane extractions and hexane rinses. These included siloxanes, trimethyl silanol, methoxy trimethyl silane, hexamethyl disiloxane, aliphatic hydrocarbons, dioctyl phthalate, and emulsifiers. Cumulatively, these species amounted to less than 3% of the antifoam mass. The majority of the antifoam was identified using carbon analysis of the SRAT product (40-80% by mass) and silicon analysis (23-83% by mass) of the condensate. Both studies recommended a better solvent for antifoam and more specific tests for antifoam degradation products than the Si and C analyses used. (3) The DWPF Antifoam 747 Purchase Specification was revised in Month, 2011 with a goal of increasing the quality of Antifoam 747. The purchase specification was changed to specify the manufacturer and product for both components that are blended by Siovation to produce Antifoam 747 for DWPF. Testing of Antifoam produced using both the old and new antifoam specifications perform very similarly in testing. Since the change in purchase specification has not improved antifoam performance, an improved antifoam agent is required.

36 MATERIALS SCIENCE↗

Chemical Characterization Results for Tank 40 Sludge Batch 10 Waste Acceptance Product Specifications (WAPS) Sample

A 3-L sample (HTF-40-23-24) obtained from Tank 40 following transfer of Tank 51 to achieve the final Sludge Batch 10 processing composition was received by Savannah River National Laboratory (SRNL). SRNL was tasked with characterization of the sample in accordance with requirements for reporting the Waste Acceptance Product Specifications. A representative subsample, approximately 500 mL, was prepared by continuously agitating the 3-L sample via a mixing blade inserted into the bottle. This subsample was then used for the chemical and physical characterization reported here. This characterization includes the following: (1) Supernate and slurry density; (2) Weight percent solids; (3) Mercury Analysis (supernate and slurry); (4) Anions; (5) Total Organic/Inorganic Carbon; (6) Free Hydroxide; (7) Other Base; (8) Elementals; (9) Volatile Organic Analysis and Semi-volatile Organic Analysis; and (10) Fissile Radionuclides and Uranium Enrichment. The results of this physical and chemical characterization of the sample are documented in this report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Consequences of sludge composition on combustion performance derived from thermogravimetry analysis

Highlights: • Volatiles, particularly proteins, play a key role in sludge combustion. • Sludge combustion performance varies with different sludge organic concentrations. • Carbohydrates significantly affect the combustion rate in the second stage. • Combustion performance of digested sludge is more negative compared with others. - Abstract: Wastewater treatment plants produce millions of tons of sewage sludge. Sewage sludge is recognized as a promising feedstock for power generation via combustion and can be used for energy crisis adaption. We aimed to investigate the quantitative effects of various sludge characteristics on the overall sludge combustion process performance. Different types of sewage sludge were derived from numerous wastewater treatment plants in Beijing for further thermogravimetric analysis. Thermogravimetric–differential thermogravimetric curves were used to compare the performance of the studied samples. Proximate analytical data, organic compositions, elementary composition, and calorific value of the samples were determined. The relationship between combustion performance and sludge composition was also investigated. Results showed that the performance of sludge combustion was significantly affected by the concentration of protein, which is the main component of volatiles. Carbohydrates and lipids were not correlated with combustion performance, unlike protein. Overall, combustion performance varied with different sludge organic composition. The combustion rate of carbohydrates was higher than those of protein and lipid, and carbohydrate weight loss mainly occurred during the second stage (175–300 °C). Carbohydrates have a substantial effect on the rate of system combustion during the second stage considering the specific combustion feature. Additionally, the combustion performance of digested sewage sludge is more negative than the others.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A device for volatile organic compound (VOC) analysis from skin using heated dynamic headspace sampling

Abstract Human skin is an important source of volatile organic compounds (VOCs) offering noninvasive methods to gain clinical metabolite information. This work was focused on the development of a skin sampling device based on a dynamic headspace sampling method with the addition of temperature to increase VOC metabolite recovery. The device preconcentrates skin VOC emissions onto a sorbent substrate, which can either be preserved for offline analysis or attached to a real time sensor downstream. In this work, skin VOC samples were analyzed offline using thermal desorption-gas chromatography-mass spectrometry. A list of 10 common skin VOCs was pre-selected to optimize parameters of sampling time, sampling temperature, and sorbent selection. Overall, this study highlights an effective skin VOC sampling technology with a heating dimension (40 °C, rather than 30 °C or no heating) with a sampling time of 15 min (rather than 5 or 30 mins) and onto Tenax TA sorbent (rather than PDMS), which collectively increases the recovery of compounds with lower vapor pressure and decreases the observed variability in skin VOC measurements. Finally, a list of 79 skin VOC compounds were detected and identified within a cohort of 20 young, healthy volunteers.

Biochemistry & Molecular Biology↗