Search NASA⌕ Search

SEARCH · Search NASA

Results for “WEATHERIZATION ASSISTANCE PROGRAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Energy Auditor and Quality Control Inspector Certification Updates

This presentation discusses recent and future Home Energy Professional credential and resource updates at the National Renewable Energy Laboratory in support to the U.S Department of Energy's Weatherization Assistance Program (WAP). It will provide an in-depth overview of planned improvements to the EA and QCI certification schemes.

certification↗

Retrofit of Blown Attic Insulation in Existing HUD-Code Manufactured Homes: Needs Assessment Report

This needs assessment was conducted by the Washington State University (WSU) Energy Program and Building Science Corporation (BSC), with support from the U.S. Department of Energy's (DOE) Building Technologies Office. The primary goal of this research was to identify moisture durability, energy savings, and savings-to-investment ratio (SIR) research needs related to the retrofit of attic insulation in the DOE Weatherization Assistance Program (WAP). Specifically, manufactured homes that comply with building codes established by the U.S. Department of Housing and Urban Development (HUD) built after 1976 and sited in colder climates. This project assessed current practice of WAP insulation and/or roof venting solutions that improve attic insulation energy savings and durability. WSU and BSC conducted outreach to stakeholders via email, phone, one-on-one interviews, and group meetings designed to inquire about relevant issues that they may have observed. Needs assessment feedback was provided from stakeholders involved with attic insulation retrofits in existing HUD-code manufactured housing in the colder climates of the United States. The list of more than 50 stakeholders who provided input into this needs assessment is provided in Appendix A.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retrofit of Blown Attic Insulation in Existing HUD-Code Manufactured Homes: Needs Assessment Report

This needs assessment was conducted by the Washington State University (WSU) Energy Program and Building Science Corporation (BSC), with support from the U.S. Department of Energy's (DOE) Building Technologies Office. The primary goal of this research was to identify moisture durability, energy savings, and savings-to-investment ratio (SIR) research needs related to the retrofit of attic insulation in the DOE Weatherization Assistance Program (WAP). Specifically, manufactured homes that comply with building codes established by the U.S. Department of Housing and Urban Development (HUD) built after 1976 and sited in colder climates. This project assessed current practice of WAP insulation and/or roof venting solutions that improve attic insulation energy savings and durability. WSU and BSC conducted outreach to stakeholders via email, phone, one-on-one interviews, and group meetings designed to inquire about relevant issues that they may have observed. Needs assessment feedback was provided from stakeholders involved with attic insulation retrofits in existing HUD-code manufactured housing in the colder climates of the United States. The list of more than 50 stakeholders who provided input into this needs assessment is provided in Appendix A.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low-e Storm Windows: Market Assessment and Pathways to Market Transformation

Laboratory and field studies sponsored by the U.S. Department of Energy (DOE) demonstrate that the use of low-emissivity (low-e) storm windows can lead to significant heating and cooling energy savings in homes. This report examines the market for low-e storm windows based on market data, case studies, and recent experience with weatherization deployment programs. It uses information from interviews conducted with DOE researchers and industry partners involved in case studies and early deployment efforts related to low-e storm windows. In addition, this study examines potential barriers to market acceptance, assesses the market and energy savings potential, and identifies opportunities to transform the market for low-e storm windows and overcome market adoption barriers. Based on laboratory testing, case studies, and climate-based modeled energy savings, the installation of low-e storm windows is estimated to reduce heating and cooling consumption by 12 to 33% in residential homes. Individual home savings would depend on the overall condition of existing windows and home as well as climate conditions. Based on these heating and cooling saving ranges, low-e storm windows have a technical potential energy savings – that is, the energy savings that would result if all low-performing windows were covered with low-e storm windows – ranging from 0.7 to 1.96 quadrillion Btus primary (source) energy. Of this technical potential, this study estimates that market adoption of low-e storm windows could reasonably achieve savings of 140 trillion Btus of primary energy annually by 2025, assuming DOE implements a number of market transformation activities directed toward low-e storm window market adoption. To assess the marketability and market adoption potential of low-e storm windows, this study examines and characterizes the benefits and costs of the technology, the size and characteristics of likely target markets, the potential pathways to reach these markets, possible market barriers, and the likelihood of overcoming these barriers. A number of promising market transformation pathways are identified including existing weatherization assistance programs, utility energy-efficiency incentive programs, federally sponsored energy efficiency retrofit programs, standards and rating organizations, and federal building energy-efficiency mandates and programs. By working with storm window manufacturers, installers, energy-efficiency consortiums, and the Federal Energy Management Program, the U.S. Department of Energy’s Building America program could implement a number of targeted outreach, education, and technical assistance programs to help effectively transform the market for low-e storm windows and have a measurable impact on reducing residential energy consumption over time.

Building America↗

Air Leakage of US Homes: Regression Analysis and Improvements from Retrofit

LBNL Residential Diagnostics Database (ResDB) contains blower door measurements and other diagnostic test results of homes in United States. Of these, approximately 134,000 single-family detached homes have sufficient information for the analysis of air leakage in relation to a number of housing characteristics. We performed regression analysis to consider the correlation between normalized leakage and a number of explanatory variables: IECC climate zone, floor area, height, year built, foundation type, duct location, and other characteristics. The regression model explains 68% of the observed variability in normalized leakage. ResDB also contains the before and after retrofit air leakage measurements of approximately 23,000 homes that participated in weatherization assistant programs (WAPs) or residential energy efficiency programs. The two types of programs achieve rather similar reductions in normalized leakage: 30% for WAPs and 20% for other energy programs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Assessing the Potential of Social Networks as a Means for Information Diffusion the Weatherization Experiences (WE) Project.

In April 2009, U.S. Department of Energy (DOE) formally tasked Oak Ridge National Laboratory (ORNL) with conducting two impact and process evaluations of DOE’s Weatherization Assistance Program (WAP), known as the retrospective and American Recovery and Reinvestment Act of 2009 (ARRA) period evaluations, respectively. The former focused on WAP Program Year (PY) 2008, which covers the period from April 2008 to June 2009. The latter focused on PY 2010. This report presents in-depth analyses from ORNL’s social network study, the Weatherization Experiences (WE) Project, an exploratory study conducted as part of the ARRA period WAP evaluation. The WE Project explored the potential for WAP recipients and staff to influence energy savings beyond their homes and day jobs. Several studies conducted through ORNL’s evaluation of WAP found that the program has the ability to profoundly impact the lives of the people it serves (Tonn et al. 2014b). Recipients of WAP provided statements ranging from the newfound ability to pay utility bills and prescription medication to reduced emergency department visits for asthma and medical conditions associated with thermal stress. Through this exploratory research project, the stories of hundreds of weatherization recipients and providers were documented. The WE Project was designed to further investigate whether or not shared experiences with weatherization have the power to stimulate home energy saving action within an individual’s social network.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

WAP Innovation and Collaboration: Updates from NREL

The National Renewable Energy Laboratory (NREL) gives an update on initiatives supporting the Weatherization Assistance Program (WAP). This presentation explains how to leverage NREL's cutting-edge resources, tools, and workforce initiatives to strengthen organizations' impact within the WAP network.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION,↗

Leveraging T&TA Plans to Support State Workforce Development Needs

This presentation talks about how to maximize training and technical assistance (T&TA) budgets within the Weatherization Assistance Program (WAP). Grantees share creative ways they've used T&TA funds to support workforce recruitment and retention, staff training, work quality, monitoring, and more.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION,↗

Installer Badges Toolkit

As the focus on home energy efficiency grows, the National Renewable Energy Lab (NREL) and the U.S. Department of Energy (DOE) Weatherization Assistance Program (WAP) are collaborating with the home energy retrofit industry to support the development of skilled workers. The Installer Badges Toolkit provides a flexible, customizable, and voluntary approach to training and skills recognition for WAP implementers, utility programs, private sector workers, and contractors.

ENERGY PLANNING, POLICY, AND ECONOMY↗

Building for Growth: Weatherization Updates from NREL

Our NREL team (Jal Desai, Juliana Williams, and Cory Chovanec) will discuss recent and future projects at the National Renewable Energy Laboratory in support to the U.S Department of Energy's Weatherization Assistance Program (WAP). NREL staff will provide updates on several initiatives, including worker credentials, Standard Work Specifications, visualization resources, and more! Be prepared to provide feedback and share new ideas in pursuit of continuous improvement within WAP.

continuous improvement↗

Reducing Deferrals by Integrating Health Homes with Weatherization

The U.S. Department of Energy’s Weatherization Assistance Program (WAP) improves energy efficiency and household health for low-income families, yet a substantial number of otherwise eligible homes are deferred from due to health and safety concerns in their homes, including mold, moisture damage, or structural deficiencies. These deferred homes are often occupied by marginalized or otherwise vulnerable residents who may be exposed to elevated indoor air pollutant concentration. Integrating Healthy Homes (HH) interventions with weatherization has been proposed as a strategy to reduce deferrals, address environmental justice concerns, and improve health outcomes. However, limited data on the health and economic implications of such integration exist. This study aimed to assess the potential health benefits and savings-to-investment ratio (SIR) associated with integrating Healthy Homes interventions into weatherization programs for homes typically deferred from WAP services. We collected indoor air pollutant data from homes undergoing health home renovations, including fine particulate matter (PM 2.5 ), nitrogen dioxide (NO 2 ), carbon monoxide (CO), and formaldehyde, with sampling times up to one month. Except for fomaldehyde, which was measured using passive UMEx badges, the other metrics were measured using the airQ Pro indoor air quality monitor.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demystifying Solar in WAP

Over the last two years, the National Renewable Energy Laboratory has identified the pathways for implementing solar in the Weatherization Assistance Program and Low Income Home Energy Assistance Program and practices for successful implementation. Learn about successful implementation models from around the network and the new resources that can give you a head start in planning solar into your program, including a demonstration of tools to help evaluate solar potential and cost-effectiveness at the household level, as well as a new tool from the U.S. Department of Energy National Community Solar Partnership to help connect households receiving LIHEAP assistance to community solar subscriptions that guarantee energy bill savings.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗

Energy Efficiency and Renewable Energy Resources for State and Local Leaders

The Weatherization and Intergovernmental Programs Office (WIP) is part of DOE’s Office of Energy Efficiency and Renewable Energy (EERE) and supports DOE’s mission to create greater energy affordability, security, and resilience. WIP’s mission is to enable strategic investments in energy efficiency and renewable energy technologies using innovative practices across the United States in partnership with a wide range of stakeholders, including state and local organizations and community-based nonprofits. WIP supports DOE’s strategic objective to lower energy bills while expanding cost-effective energy choices for all Americans through the Weatherization Assistance Program (WAP) and State Energy Program (SEP). This resource guide highlights resources and publications from the State and Local Solution Center website and across EERE programs.

cost-effective energy, energy efficiency, tools an↗

WAP Workforce Needs Analysis

As identified through stakeholder dialogue, Weatherization Assistance Program (WAP) Grantees and Subgrantees face challenges in hiring and retaining field staff in the following positions: Retrofit Installers/Technicians (RITs), Crew Leaders (CLs), Energy Auditors (EAs), and Quality Control Inspectors (QCIs). To gain a baseline understanding of workforce needs, NREL collected voluntary workforce data from May 4-June 30, 2022. This presentation includes a qualitative analysis of this data, key takeaways, and an introduction to new tools supporting WAP workforce development.

ENERGY PLANNING, POLICY, AND ECONOMY↗

Weatherization Crew Leader Job Task Analysis

The US Department of Energy's Guidelines for Home Energy Professionals project maintains job task analyses for jobs in the Weatherization Assistance Program and home performance industry. One of those jobs is Crew Leader, defined as: 'A Crew Leader is responsible for supervising and assisting in the retrofitting activities specified in the scope of work. He or she is responsible for interacting with the client plus managing personnel and materials on the job site in a safe and effective manner. The Crew Leader is responsible for quality control, testing procedures, documentation, and conducting a walk through in preparation that all work is completed in a satisfactory manner.' This document is an updated version of the Crew Leader job task analysis.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Using Retrofit Nail Base Panels to Expand the Market for Wall Upgrades

This project evaluated the effectiveness and affordability of integrating retrofit insulated panels into a re-siding project. The Partnership for Home Innovation (PHI) teamed with New York State Energy Research and Development Authority (NYSERDA), the Albany Housing Authority (AHA), and the New York State Weatherization Assistance Program (WAP) administered by Albany Community Action Partnership to demonstrate an energy retrofit and siding upgrade on a two-story, seven unit, multifamily building in Albany New York (CZ 5). The project focused on accomplishing three goals - doubling the existing wall thermal resistance (from approximately R-13 to a weighted average of R-27), reduction of building air leakage, and completion of the retrofit within a budget where the additional cost for upgrading wall's thermal resistance is equal to the cost of the standard re-siding effort (i.e., the total cost of the energy efficient re-siding scope of work is not more than double the cost of the standard re-siding effort). Lessons learned from the project strongly indicate that the retrofit panel technology can be installed using common installation practices and with minimal training. Other lessons learned include limitation on the use of standard air sealing materials during cold weather installations and the need to develop better installation guidance for trades working with the level of tolerances that may be present in the existing structure. This technology demonstration showed that exterior retrofit panels provide a viable and reasonable option for the siding trades to increase market opportunities and achieve synergistic benefits for aesthetic upgrades to a building's exterior.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Trade-Friendly Retrofit Insulated Panels for Existing Buildings, Albany, New York

This project evaluated the effectiveness and affordability of integrating retrofit insulated panels into a re-siding project. The Partnership for Home Innovation (PHI) teamed with New York State Energy Research and Development Authority (NYSERDA), the Albany Housing Authority (AHA), and the New York State Weatherization Assistance Program (WAP) administered by Albany Community Action Partnership to demonstrate an energy retrofit and siding upgrade on a two-story, seven unit, multifamily building in Albany New York (CZ 5). The project focused on accomplishing three goals - doubling the existing wall thermal resistance (from approximately R-13 to a weighted average of R-27), reduction of building air leakage, and completion of the retrofit within a budget where the additional cost for upgrading wall's thermal resistance is equal to the cost of the standard re-siding effort (i.e., the total cost of the energy efficient re-siding scope of work is not more than double the cost of the standard re-siding effort). Lessons learned from the project strongly indicate that the retrofit panel technology can be installed using common installation practices and with minimal training. Other lessons learned include limitation on the use of standard air sealing materials during cold weather installations and the need to develop better installation guidance for trades working with the level of tolerances that may be present in the existing structure. This technology demonstration showed that exterior retrofit panels provide a viable and reasonable option for the siding trades to increase market opportunities and achieve synergistic benefits for aesthetic upgrades to a building's exterior.

33 ADVANCED PROPULSION SYSTEMS↗

Electrify Monterey Bay

The Electrify Monterey Bay project, delivered by Central Coast Energy Services (CCES) under DOE Weatherization Assistance Program Enhancement & Innovation (E&I) funding, was designed to demonstrate scalable, low-income residential electrification across the Monterey Bay region over a 36-month performance period. The original production goal was to electrify at least 50 households; CCES exceeded this benchmark by completing electrification work in 86 households. Targeting criteria prioritized households located in disadvantaged communities and/or with an energy burden >6.5% (defined as average household energy costs divided by average household countable income). Across participating households, the average energy burden was 28%, indicating a high-need population and supporting the program’s equity and affordability objectives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗