Search NASA⌕ Search

SEARCH · Search NASA

Results for “WIDE ANGLE LENS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

59 records · Page 4

Cloud Ozone Dust Imager (CODI): Investigation and Technical Plan - Volume 1

The Cloud Ozone Dust Imager (CODI) is proposed to investigate the current climatic balance of the Mars atmosphere, with particular emphasis on the important but poorly understood roles which dust and water ice aerosols play in this balance. The large atmospheric heating (20-50 K) resulting from global dust storms around Mars perihelion is well recognized. However, groundbased observations of Mars atmospheric temperatures, water vapor, and clouds since the Viking missions have identified a much colder, cloudier atmosphere around Mars aphelion that may prove as important as global dust storms in determining the interannual and long-term behavior of the Mars climate. The key climate issues CODI is designed to investigate are: 1) the degree to which non-linear interactions between atmospheric dust heating, water vapor saturation, and cloud nucleation influence the seasonal and interannual variability of the Mars atmosphere, and 2) whether the strong orbital forcing of atmospheric dust loading, temperatures and water vapor saturation determines the long-term balance of Mars water, as reflected in the north-south hemispheric asymmetries of atmospheric water vapor and polar water ice abundances. The CODI experiment will measure the daily, seasonal and (potentially) interannual variability of atmospheric dust and cloud opacities, and the key physical properties of these aerosols which determine their role in the climate cycles of Mars. CODI is a small (1.2 kg), fixed pointing camera, in which four wide-angle (+/- 70 deg) lenses illuminate fixed filters and CCD arrays. Simultaneous sky/surface imaging of Mars is obtained at an angular resolution of 0.28 deg/pixel for wavelengths of 255, 336, 502, and 673 nm (similar to Hubble Space Telescope filters). These wavelengths serve to measure atmospheric ozone (255 and 336 nm), discriminate ice and dust aerosols (336 and 673 nm), and construct color images (336, 502, and 673 nm). The CODI images are detected on four 512 x 512 pixel arrays, as partitioned on two 1024 x 1024 CCD's operated in frame transfer mode. The center of the CODI field-of-view is canted 40 deg from the zenith direction to obtain sky brightness measurements and a 20 deg surface field-of-view. Daily image observations will be conducted when the Sun is greater than or equal to 5 deg outside the edge of the CODI field-of-view, and twilight and nighttime imaging will obtained on a weekly basis. The 673 nm channel includes a polarizer wheel to obtain sky/surface polarimetry. A dust cover protects the entire lens assemblies of all four CODI channels. This opaque dust cover, which is normally opened for CODI imaging, includes a small fixed mirror and transparent window positioned above the 673 nm lens, to redirect the 673 nm field-of-view to the surface for descent imaging. Fixed pointing, internal data buffering, low operating power (2-4 W for less than or equal to 30 seconds), selective data transmission, and simple operational characteristics of the CODI experiment place minimum resource and operational demands on the Mars Surveyor 1998 lander. The CODI science goals are optimized for, but not restricted to, a low-latitude landing site (20 deg S-30 deg N). The primary CODI measurement objectives are the opacities, wave forms, particle properties (size, shape, and alignment), and heights of clouds; the opacities, particle properties, and vertical distribution of dust; and the opacity and vertical distribution of ozone. The variability of cloud, ozone, and dust opacities will be determined on diurnal, daily, and seasonal timescales. Wind velocities will be determined from cloud motions and wave characteristics; and the temporal variability of atmospheric water vapor, with limited altitude information, will be inferred from the CODI ozone observations. Secondary measurement objectives include limited descent imaging capability, surface uv-visible photometry and polarimetry, photochemistry, and meteorite infall rates.

Clancy, R. Todd↗

Tunable-Bandwidth Filter System

A tunable-bandwidth filter system (TBFS), now undergoing development, is intended to be part of a remote sensing multispectral imaging system that will operate in the visible and near infrared spectral region (wavelengths from 400 to 900 nm). Attributes of the TBFS include rapid tunability of the pass band over a wide wavelength range and high transmission efficiency. The TBFS is based on a unique integration of two pairs of broadband Raman reflection holographic filters with two rotating spherical lenses. In experiments, a prototype of the TBFS, was shown to be capable of spectral sampling of images in the visible range over a 200 nm spectral range with a spectral resolution of 30 nm. The figure depicts the optical layout of a prototype of the TBFS as part of a laboratory multispectral imaging system for the spectral sampling of color test images in two orthogonal polarizations. Each pair of broadband Raman reflection holographic filters is mounted at an equatorial plane between two halves of a spherical lens. The two filters in each pair are characterized by steep spectral slopes (equivalently, narrow spectral edges), no ripple or side lobes in their pass bands, and a few nanometers of non-overlapping wavelength range between their pass bands. Each spherical lens and thus the filter pair within it is rotated in order to rapidly tune its pass band. The rotations of are effected by electronically controlled, programmable, high-precision rotation stages. The rotations are coordinated by electronic circuits operating under overall supervision of a personal computer in order to obtain the desired variation of the overall pass bands with time. Embedding the filters inside the spherical lenses increases the range of the hologram incidence angles, making it possible to continuously tune the pass and stop bands of the filters over a wider wavelength range. In addition, each spherical lens also serves as part of the imaging optics: The telephoto lens focuses incoming light to a field stop that is also a focal point of each spherical lens. A correcting lens in front of the field stop compensates for the spherical aberration of the spherical lenses. The front surface of each spherical lens collimates the light coming from the field stop. After the collimated light passes through the filter in the spherical lens, the rear surface of the lens focuses the light onto a charge-coupled-device image detector.

Bailey, John W.↗

Tunable-Bandwidth Filter System

A tunable-bandwidth filter system (TBFS), now undergoing development, is intended to be part of a remote-sensing multispectral imaging system that will operate in the visible and near infrared spectral region (wavelengths from 400 to 900 nm). Attributes of the TBFS include rapid tunability of the pass band over a wide wavelength range and high transmission efficiency. The TBFS is based on a unique integration of two pairs of broadband Raman reflection holographic filters with two rotating spherical lenses. In experiments, a prototype of the TBFS was shown to be capable of spectral sampling of images in the visible range over a 200-nm spectral range with a spectral resolution of .30 nm. The figure depicts the optical layout of a prototype of the TBFS as part of a laboratory multispectral imaging system for the spectral sampling of color test images in two orthogonal polarizations. Each pair of broadband Raman reflection holographic filters is mounted at an equatorial plane between two halves of a spherical lens. The two filters in each pair are characterized by steep spectral slopes (equivalently, narrow spectral edges), no ripple or side lobes in their pass bands, and a few nanometers of non-overlapping wavelength range between their pass bands. Each spherical lens and thus the filter pair within it is rotated in order to rapidly tune its pass band. The rotations of the lenses are effected by electronically controlled, programmable, high-precision rotation stages. The rotations are coordinated by electronic circuits operating under overall supervision of a personal computer in order to obtain the desired variation of the overall pass bands with time. Embedding the filters inside the spherical lenses increases the range of the hologram incidence angles, making it possible to continuously tune the pass and stop bands of the filters over a wider wavelength range. In addition, each spherical lens also serves as part of the imaging optics: The telephoto lens focuses incoming light to a field stop that is also a focal point of each spherical lens. A correcting lens in front of the field stop compensates for the spherical aberration of the spherical lenses. The front surface of each spherical lens collimates the light coming from the field stop. After the collimated light passes through the filter in the spherical lens, the rear surface of the lens focuses the light onto a charge-coupled-device image detector.

Aye, Tin↗

Large Aperture Scanning Lidar Based on Holographic Optical Elements

Lidar remote sensing instruments can make a significant contribution to satisfying many of the required measurements of atmospheric and surface parameters for future spaceborne platforms, including topographic altimeters, atmospheric profiles of, wind, humidity, temperature, trace molecules, aerosols, and clouds. It is highly desirable to have wide measurement swaths for rapid coverage rather than just the narrow ribbon of data that is obtained with a nadir only observation. For most applications global coverage is required, and for wind measurements scanning or pointing is required in order to retrieve the full 3-D wind vector from multiple line-of-sight Doppler measurements. Conventional lidar receivers make up a substantial portion of the instrument's size and weight. Wide angle scanning typically requires a large scanning mirror in front of the receiver telescope, or pointing the entire telescope and aft optics assembly, Either of these methods entails the use of large bearings, motors, gearing and their associated electronics. Spaceborne instruments also need reaction wheels to counter the torque applied to the spacecraft by these motions. NASA has developed simplified conical scanning telescopes using Holographic Optical Elements (HOEs) to reduce the size, mass, angular momentum, and cost of scanning lidar systems. NASA has developed two operating lidar systems based on 40 cm diameter HOEs. The first such system, named Prototype Holographic Atmospheric Scanner for Environmental Remote Sensing (PHASERS) was a joint development between NASA Goddard Space Flight Center (GSFC) and the University of Maryland College Park. PHASERS is based on a reflection HOE for use at the doubled Nd:YAG laser wavelength of 532 nm and has recently undergone a number of design changes in a collaborative effort between GSFC and Saint Anselm College in New Hampshire. The next step was to develop IR transmission HOEs for use with the Nd:YAG fundamental in the Holographic Airborne Rotating Lidar Instrument Experiment (HARLIE). The HOE spins like a compact disk in a large ring ball bearing. In an aircraft the HOE faces down, looking out through a window at an angle of 45 degrees off-nadir. The HOE diffracts 85% of the incident 532 nm light into a 160 micron spot at a focal length of 1 meter. HARLIE is a field deployable lidar measuring aerosol, cloud, and boundary layer backscatter for atmospheric research. It has flown several times and is also used from a ground-based trailer in an upward-looking mode. The HOE generates a 45 degree conical scan pattern by rotating at speeds up to 30 rpm. Like PHASERS, the HOE in HARLIE serves both as the laser collimating lens as well as the receiver telescope primary optic. The telescope is coupled to the receiver package via fiber optic. The transmitter is a diode pumped Nd:YAG laser operating at 1064 nm, delivering 1 mJ pulses at a 5 KHz rep-rate. The receiver has a 200 microradian field-of-view and a 0.5 nm optical bandpass. The photon counting data system utilizes a single Geiger-mode silicon avalanche photodiode detector, This new technology has also presented us with new data visualization challenges as well as new measurement techniques. The backscatter data obtained from a stationary (i.e. ground-based) scanning HOE lidar is on the surface of a cone, which when viewed over many consecutive scans can reveal atmospheric motions on this surface over time as the atmosphere advects over the site. In a moving platform such as an airplane or satellite, the data from consecutive scans cover different areas under the flight path, revealing atmospheric structure in 3-dimensions. An example of a visualization of HARLIE ground-based data is presented, showing aerosol backscatter on a 90 degree conical surface generated from one 360 degree scan of the lidar during the HOLO-1 field campaign on the afternoon of 10 March 1999. Higher backscatter levels are rendered as lighter signal against a dark background. Breaking Kelvin-Helmholtz waves are evident on the north side of the scan at an altitude of 10-11 km. Time series of successive scans made at regular intervals render unique views of atmospheric motions, from which vertical profiles of atmospheric wind vectors can be obtained using a unique data analysis approach. Wind vectors obtained from the lidar were compared with co-located radiosonde wind profiles during an intensive operating period in September-October 2000 at the Atmospheric Radiation Measurement Program's Southern Great Plains Central Facility.

Schwemmer, Geary K.↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗