Search NASA⌕ Search

SEARCH · Search NASA

Results for “WIND TUNNEL FANS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Performance of a model cascade thrust reverser for short-haul applications

Aerodynamic and acoustic characteristics are presented for a cowl-mounted, model cascade thrust reverser suitable for short-haul aircraft. Thrust reverser efficiency and the influence on fan performance were determined from isolated fan-driven models under static and forward velocity conditions. Cascade reverser noise characteristics were determined statically in an isolated pipe-flow test, while aerodynamic installation effects were determined with a wind-tunnel, fan-powered airplane model. Application of test results to short-haul aircraft calculations demonstrate that such a cascade thrust reverser may be able to meet both the performance and noise requirements for short-haul aircraft operation. However, aircraft installation effects can be quite significant.

Dietrich, D. A.↗

Exploratory study to induce fan noise in the test section of the NASA Langley full-scale wind tunnel

Measures to reduce the intensity of fan noise in the NASA Langley 30 ft x 60 ft subsonic wind tunnel were sought. Measurements were first performed to document existing aerodynamic and acoustic conditions. The purpose of these experiments was to (1) obtain the transfer function between the sound power output of the fan and the sound pressure on the test platform, (2) evaluate the sound attenuation around the tunnel circuit, (3) measure simultaneously the flow profile and the turbulence spectrum of the inflow to the fan and the noise on the test platform, and (4) perform flow observations and identify secondary noise sources. Subsequently, these data were used to predict (1) the relative contribution of the major aerodynamic parameters to total fan noise and (2) the effect of placing a dissipative silencer in the collector duct upstream of the fan. Promising noise control measures were identified and recommendations were made on how to evaluate them.

Ver, I. L.↗

A new blade element method for calculating the performance of high and intermediate solidity axial flow fans

A method is presented to design and predict the performance of axial flow rotors operating in a duct. The same method is suitable for the design of ducted fans and open propellers. The unified method is based on the blade element approach and the vortex theory for determining the three dimensional effects, so that two dimensional airfoil data can be used for determining the resultant force on each blade element. Resolution of this force in the thrust and torque planes and integration allows the total performance of the rotor, fan or propeller to be predicted. Three different methods of analysis, one based on a momentum flow theory; another on the vortex theory of propellers; and a third based on the theory of ducted fans, agree and reduce cascade airfoil data to single line as a function of the loading and induced angle of attack at values of constant inflow angle. The theory applies for any solidity from .01 to over 1 and any blade section camber. The effects of the duct and blade number can be determined so that the procedure applies over the entire range from two blade open propellers, to ducted helicopter tail rotors, to axial flow compressors with or without guide vanes, and to wind tunnel drive fans.

Borst, H. V.↗

Wind tunnel test results of a 1/8-scale fan-in-wing model

A 1/8-scale model of a fan-in-wing concept considered for development by Grumman Aerospace Corporation for the U.S. Army was tested in the Langley 14- by 22-Foot Subsonic Tunnel. Hover testing, which included height above a pressure-instrumented ground plane, angle of pitch, and angle of roll for a range of fan thrust, was conducted in a model preparation area near the tunnel. The air loads and surface pressures on the model were measured for several configurations in the model preparation area and in the tunnel. The major hover configuration change was varying the angles of the vanes attached to the exit of the fans for producing propulsive force. As the model height above the ground was decreased, there was a significant variation of thrust-removed normal force with constant fan speed. The greatest variation was generally for the height-to-fan exit diameter ratio of less than 2.5; the variation was reduced by deflecting fan exit flow outboard with the vanes. In the tunnel angles of pitch and sideslip, height above the tunnel floor, and wind speed were varied for a range of fan thrust and different vane angle configurations. Other configuration features such as flap deflections and tail incidence were evaluated as well. Though the V-tail empennage provided an increase in static longitudinal stability, the total model configuration remained unstable.

Wilson, John C.↗

Experimental Characterization of an Electric Ducted Fan for the SUSAN 25% Scale Research Vehicle

An electric ducted fan (EDF) was tested in the NASA Langley 12-Foot Low-Speed Tunnel for the SUbsonic Single Aft eNgine (SUSAN) Electrofan 25% scale research vehicle, which incorporates distributed electric fans along the wings and serves as a scaled electrified transport aircraft testbed. The commercial-off-the-shelf EDF was selected as a propulsor that can meet the 25% scale vehicle geometry constraints, along with the performance requirements throughout the flight profile. The test included a series of one-factor-at-a-time (OFAT) and design of experiments (DOE) approaches that were implemented across a range of fan speed, voltage, freestream dynamic pressure, and incidence angle settings to characterize the performance of the EDF. Several test matrix designs and modeling approaches were considered. System identification methods were used to develop a static motor model, a dynamic motor model, an EDF thrust model, and a power consumption model. The model predictive capabilities were then evaluated with validation data not used in the modeling process. The results provide a comprehensive set of models developed to characterize the fan, and offer general insight into EDF modeling approaches.

electric ducted fan↗

The U.S. 2.5-Meter Cryogenic High Reynolds Number Tunnel

The U.S. 2.5-Meter Cryogenic High Reynolds Number Tunnel is a fan-driven transonic wind tunnel scheduled for operation in 1981. It will operate at Mach numbers from 0.1 to 1.2, stagnation pressures from 1 to 9 bars, and stagnation temperatures from 352 to 80 Kelvin. The maximum Reynolds number capability will be 120 million at a Mach number of 1.0 based on a reference length of 0.25 meter. This paper describes the basis for the conceptual approach, the engineering design including unique features, and the performance operating envelopes for the tunnel.

Howell, R. R.↗

Numerical Simulation of an Enclosed Laminar Jet Diffusion Flame in Microgravity Environment: Comparison with ELF Data

Enclosed diffusion flames are commonly found in practical combustion systems, such as the power-plant combustor, gas turbine combustor, and jet engine after-burner. In these systems, fuel is injected into a duct with a co-flowing or cross-flowing air stream. The diffusion flame is found at the surface where the fuel jet and oxygen meet, react, and consume each other. In combustors, this flame is anchored at the burner (i.e., fuel jet inlet) unless adverse conditions cause the flame to lift off or blow out. Investigations of burner stability study the lift off, reattachment, and blow out of the flame. Flame stability is strongly dependent on the fuel jet velocity. When the fuel jet velocity is sufficiently low, the diffusion flame anchors at the burner rim. When the fuel jet velocity is increased, the flame base gradually moves downstream. However, when the fuel jet velocity increases beyond a critical value, the flame base abruptly jumps downstream. When this "jump" occurs, the flame is said to have reached its lift-off condition and the critical fuel jet velocity is called the lift-off velocity. While lifted, the flame is not attached to the burner and it appears to float in mid-air. Flow conditions are such that the flame cannot be maintained at the burner rim despite the presence of both fuel and oxygen. When the fuel jet velocity is further increased, the flame will eventually extinguish at its blowout condition. In contrast, if the fuel jet velocity of a lifted flame is reduced, the flame base moves upstream and abruptly returns to anchor at the burner rim. The fuel jet velocity at reattachment can be much lower than that at lift off, illustrating the hysteresis effect present in flame stability. Although there have been numerous studies of flame stability, the controlling mechanisms are not well understood. This uncertainty is described by Pitts in his review of various competing theories of lift off and blow out in turbulent jet diffusion flames. There has been some research on the stability of laminar flames, but most studies have focused on turbulent flames. It is also well known that the airflow around the fuel jet can significantly alter the lift off, reattachment and blow out of the jet diffusion flame. Buoyant convection is sufficiently strong in 1-g flames that it can dominate the flow-field, even at the burner rim. In normal-gravity testing, it is very difficult to delineate the effects of the forced airflow from those of the buoyancy-induced flow. Comparison of normal-gravity and microgravity flames provides clear indication of the influence of forced and buoyant flows on the flame stability. The overall goal of the Enclosed Laminar Flames (ELF) investigation (STS-87/USMP-4 Space Shuttle mission, November to December 1997) is to improve our understanding of the effects of buoyant convection on the structure and stability of co-flow diffusion flame, e.g., see http://zeta.lerc.nasa.gov/expr/elf.htm. The ELF hardware meets the experiment hardware limit of the 35-liter interior volume of the glovebox working area, and the 180x220-mm dimensions of the main door. The ELF experiment module is a miniature, fan-driven wind tunnel, equipped with a gas supply system. A 1.5-mm diameter nozzle is located on the duct's flow axis. The cross section of the duct is nominally a 76-mm square with rounded corners. The forced air velocity can be varied from about 0.2 to 0.9 m/s. The fuel flow can be set as high as 3 std. cubic centimeter (cc) per second, which corresponds to a nozzle exit velocity of up to 1.70 m/s. The ELF hardware and experimental procedure are discussed in detail in Brooker et al. The 1-g test results are repeated in several experiments following the STS-87 Mission. The ELF study is also relevant to practical systems because the momentum-dominated behavior of turbulent flames can be achieved in laminar flames in microgravity. The specific objectives of this paper are to evaluate the use reduced model for simulation of flame lift-off and blowout.

Jia, Kezhong↗

Modal Test and Analysis Correlation of Wind Tunnel Blades for the National Transonic Facility

NASA has a significant maintenance challenge with the aging wind tunnel infrastructure across the agency . Wind tunnel blades, such as the ones in the National Transonic Facility at NASA Langley Research Center, have been subjected to damage from impacts and fatigue. Accurate analytical models of these blades are necessary to either recertify replacement blades to be built or for redesign of these blades. In this paper an upgraded finite element model of these wind tunnel blades with the capability of representing damage is presented. An eigenvalue analysis of the structural model is performed, and the boundary conditions are adjusted to simulate the natural frequencies obtained by experimental testing of a set of twenty five blades in 1992. Additional numerical studies of the effect of delamination damage on the natural frequencies of the blade are conducted using the tuned finite element model.

wind tunnel↗

Modal Test and Analysis Correlation of Wind Tunnel Blades for the National Transonic Facility

NASA has a significant maintenance challenge with the aging wind tunnel infrastructure across the agency . Wind tunnel blades, such as the ones in the National Transonic Facility at NASA Langley Research Center, have been subjected to damage from impacts and fatigue. Accurate analytical models of these blades are necessary to either recertify replacement blades to be built or for redesign of these blades. In this paper an upgraded finite element model of these wind tunnel blades with the capability of representing damage is presented. An eigenvalue analysis of the structural model is performed, and the boundary conditions are adjusted to simulate the natural frequencies obtained by experimental testing of a set of twenty five blades in 1992. Additional numerical studies of the effect of delamination damage on the natural frequencies of the blade are conducted using the tuned finite element model.

wind tunnel↗

Inlet turbulence and fan noise measured in an anechoic wind tunnel and statically with an inlet flow control device

Turbulence and acoustic measurements were taken in the NASA-Lewis anechoic wind tunnel - a facility which has demonstrated the blade passage tone cutoff phenomena with forward velocity. Turbulence data were taken in a subsonic inlet at various fan speeds under static and forward velocity conditions. A honeycomb/screen flow control device was placed over the inlet during static tests to modify the inflow in an attempt to simulate flight conditions. Acoustic levels of the blade passage tone along with transverse turbulence intensities were reduced with forward velocity. The flow control device reduced the blade passage tone to an intermediate level between those levels associated with static and forward velocity operation.

Shaw, L. M.↗

CHARACTERISTICS OF LIFTING-FAN V/STOL AIRCRAFT

Wind-tunnel tests of full scale practical configuration of lifting fan v/stol aircraft show transition pitching moments comparable to conventional aircraft, and that lift increases with greater forward speed

LIFT FAN↗

Simulation of flight-type engine fan noise in the NASA-Lewis 9 x 15 anechoic wind tunnel

A major problem in the measurement of aircraft engine fan noise is the difficulty of simulating, in a ground-based facility, the noise that occurs during flight. Flight-type noise as contrasted to the usual ground-static test noise exhibits substantial reductions in both (1) the time unsteadiness of tone noise and (2) the mean level of tones calculated to be nonpropagating or cut-off. A model fan designed with cut-off of the fundamental tone was acoustically tested in the anechoic wind tunnel under both static and tunnel flow conditions. The properties that characterize flight-type noise were progressively simulated with increasing tunnel flow. The distinctly lobed directivity pattern of propagating rotor/stator interaction modes was also observed. The results imply that the excess noise attributed to the ingestion of the flow disturbances that prevail near most static test facilities was substantially reduced with tunnel flow. The anechoic wind tunnel appears to be a useful facility for applied research on aircraft engine fan noise under conditions of simulated flight.

Heidmann, M. F.↗

Wind tunnel investigation of a large-scale model of a lift/cruise fan V/STOL aircraft

An investigation was conducted in the Ames 40- by 80-Foot wind tunnel to determine the aerodynamic characteristics of a large scale model of a lift/cruise fan V/STOL aircraft. The model was equipped with three fans, one mounted in the forward section of the fuselage in a lift mode, and two mounted on top of the wing adjacent to the fuselage in a lift/cruise mode. The data that were obtained include longitudinal and lateral-directional characteristics of the model, with the horizontal tail on and off, for both the Powered lift and cruise configurations. Powered lift data were obtained at several wind tunnel velocities and at several lift/cruise fan thrust vector angles by varying the position of the hooded deflectors from 0 deg. (the cruise condition) to 90 deg.

Gambucci, B. J.↗

Experimental and analytical evaluation of the effects of simulated engine inlets on the blade vibratory stresses of the SR-3 model prop-fan

A cooperative wind tunnel test program, referred to as GUN-3, had been conducted previously to assess the effect of inlet configuration and location on the inlet face pressure recovery and inlet drag in the presence of a high-speed advanced turboprop. These tests were conducted with the inlets located just downstream of the SR-3 model Prop-Fan, a moderately swept, eight-bladed 62.2 cm (24.5 inch) diameter advanced, high-speed turboprop model fabricated from titanium. During these tests, two blades of the SR-3 model Prop-Fan were strain gaged to measure the vibratory blade stresses occurring during the inlet aerodynamic test program. The purpose of the effort reported herein was to reduce and analyze the test results related to the vibratory strain gage measurements obtained. Three inlet configurations had been tested. These were: (1) single scoop, (2) twin scoop, and (3) annular. Each of the three inlets was tested at a position just behind the rotor. The single scoop inlet was also tested at a position further aft. Tests were also done without an inlet. These results emphasize the importance of avoiding critical speeds in the continuous operating range.

Bansal, Prem N.↗

Static and Wind Tunnel Aero-Performance Tests of NASA AST Separate Flow Nozzle Noise Reduction Configurations

This report presents the results of cold flow model tests to determine the static and wind tunnel performance of several NASA AST separate flow nozzle noise reduction configurations. The tests were conducted by Aero Systems Engineering, Inc., for NASA Glenn Research Center. The tests were performed in the Channels 14 and 6 static thrust stands and the Channel 10 transonic wind tunnel at the FluiDyne Aerodynamics Laboratory in Plymouth, Minnesota. Facility checkout tests were made using standard ASME long-radius metering nozzles. These tests demonstrated facility data accuracy at flow conditions similar to the model tests. Channel 14 static tests reported here consisted of 21 ASME nozzle facility checkout tests and 57 static model performance tests (including 22 at no charge). Fan nozzle pressure ratio varied from 1.4 to 2.0, and fan to core total pressure ratio varied from 1.0 to 1.19. Core to fan total temperature ratio was 1.0. Channel 10 wind tunnel tests consisted of 15 tests at Mach number 0.28 and 31 tests at Mach 0.8. The sting was checked out statically in Channel 6 before the wind tunnel tests. In the Channel 6 facility, 12 ASME nozzle data points were taken and 7 model data points were taken. In the wind tunnel, fan nozzle pressure ratio varied from 1.73 to 2.8, and fan to core total pressure ratio varied from 1.0 to 1.19. Core to fan total temperature ratio was 1.0. Test results include thrust coefficients, thrust vector angle, core and fan nozzle discharge coefficients, total pressure and temperature charging station profiles, and boat-tail static pressure distributions in the wind tunnel.

Mikkelsen, Kevin L.↗

Acoustic Signatures of a Model Fan in the NASA-Lewis Anechoic Wind Tunnel

One-third octave band and narrowband spectra and continuous directivity patterns radiated from an inlet are presented over ranges of fan operating conditions, tunnel velocity, and angle of attack. Tunnel flow markedly reduced the unsteadiness and level of the blade passage tone, revealed the cutoff design feature of the blade passage tone, and exposed a lobular directivity pattern for the second harmonic tone. The full effects of tunnel flow are shown to be complete above a tunnel velocity of 20 meters/second. The acoustic signatures are also shown to be strongly affected by fan rotational speed, fan blade loading, and inlet angle of attack.

Dietrich, D. A.↗

Acoustic signatures of a model fan in the NASA-Lewis anechoic wind tunnel

One-third octave band and narrowband spectra and continuous directivity patterns radiated from an inlet are presented over ranges of fan operating conditions, tunnel velocity, and angle of attack. Tunnel flow markedly reduced the unsteadiness and level of the blade passage tone, revealed the cut-off design feature of the blade passage tone, and exposed a lobular directivity pattern for the second harmonic tone. The full effects of tunnel flow are shown to be complete above a tunnel velocity of 20 meters/second. The acoustic signatures are also shown to be strongly affected by fan rotational speed, fan blade loading, and inlet angle of attack.

Dietrich, D. A.↗