Search NASA⌕ Search

SEARCH · Search NASA

Results for “Wall temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Updated Estimate of Tritium Permeation from TPBAR Disposal Containers in ILV (U)

A tritium source term analysis was performed for TPBAR disposal in the E-Area Intermediate Level Vaults for the E-Area Low-Level Waste Facility Performance Assessment (PA). This analysis is based on an earlier source term analysis which treated the bulk oft he tritium residual as tightly bound by the TPBAR getter material, with only a small fraction existing as tritiated moisture in the lithium aluminate ceramic pellets. Together with atmospheric moisture trapped in the free volume, the tritiated water vapor is assumed to corrode steel surfaces inside the disposal container, covering them with a magnetite film while generating hydrogen. The carbon steel walls of the disposal container are permeable to hydrogen, providing a path way for tritium to escape containment. The rate of hydrogen generation is assumed to be limited by the rate of corrosion, which is assumed to be governed by parabolic reaction kinetics obtained from the literature. This relies on the further assumption that the water vapor consumed by the corrosion reaction is continually replaced by moisture from the lithium aluminate pellets until all of that moisture is gone. In addition to tritium permeation, the analysis also includes a slow leak through the disposal container walls at the maximum allowable leak rate, 1 x 1CH standard cm3/s. Results were obtained for four different combinations of internal and container wall temperatures, established in an earlier thermal analysis that considered two different vault loadings and two different TPBAR activity levels. Instantaneous release rates for these four cases are plotted in Figure ES-1 below

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improvements to CTF Closure Models for Modelling of Two-Phase Flow

This report documents the efforts to improve the CTF prediction of void fraction and two-phase pressure drop by improving two-phase closure models. Previous validation activities have revealed that CTF tends to overpredict void fraction and two-phase pressure drop. In response to this, two approaches were taken to improve CTF’s predictive capabilities. Based on findings that the interfacial drag and subcooled boiling models significantly impact void prediction, alternative closure models for these physical effects were found and implemented into the code. An extensive assessment was performed by using the existing and newly added two-phase experimental data, which showed that void prediction, wall temperature, and two-phase pressure-drop results are improved by using the newly implemented models. A second approach for improving CTF modeling accuracy involved the use of a Bayesian calibration process that uses CTF validation data to optimize selected modeling coefficients and closure model multipliers to achieve a more accurate prediction of experimental results. A similar assessment was performed with calibrated models that improved the void and pressure-drop prediction for test cases that were both included and not included in the calibration dataset. Results of this study will be used to change the models used in CTF to achieve more accurate BWR analyses moving forward. This study also identified opportunities for improving additional closure models and other opportunities to use calibration techniques to improve CTF.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Review and Analysis of Heat Transfer Correlations For Horizontal Pseudocritical CO 2 Heat Exchanger Applications

There is significant interest in the development of supercritical carbon dioxide (sCO 2 ) power cycles because of the potential for smaller and more energy efficient systems than a steam Rankine cycle. Heat exchanger designs typically use empirical correlations, but the applicability of these correlations near the CO 2 critical point is a potential issue. Though numerous correlations have been proposed in the literature, there are some disagreements when it comes to the accuracy. The current work recognizes the role of thermophysical properties, and its impacts on the heat transfer correlations and cycle efficiency. Heat transfer correlations proposed for horizontal flow inside circular pipes were analyzed with the help of numerical simulations. Steady state RANS simulations were performed using SST k-w turbulence model to evaluate the Nusselt number empirical correlations. It was found that the most of correlations (except Yoon) produced a Nusselt number that differed significantly with the one predicted numerically. Some of the correlations were developed for pure forced convection regime and as mentioned in Lin et al. do not account for mixed convection or free convection effects. Based on the limited observation, it appears that Yoon et al. predictions match well with the numerically predicted Nusselt Numbers. However, further analysis is required understand the applicability of various correlations and is contingent on accurate measurements or predictions of wall temperature profiles in the axial and the circumferential directions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Initial use of Nek5000/Cardinal to improve closure models in Pronghorn

Heat transfer coefficient closure models for pebble bed reactors are built using a data-driven approach by leveraging the capabilities of an Evolutionary Algorithm entitled Particle Swarm Optimization (PSO). In the present work, the Computational Fluid Dynamics code nekRS was used in order to collect the high-fidelity flow data for a core with 1,568 pebbles. To characterize the heat transfer, multiple concentric regions were considered to extract the physical quantities of interest, e.g./ the Reynolds number. The PSO algorithm is employed as part of an inverse problem targeting determine what are the coefficients for a Nusselt number correlation to match the collected data. Such correlation should follow any given format that is defined a priori. Finally, two correlations are proposed, one with an implicit dependence on the pebbles’ wall temperatures and another expressed as a fully explicit correlation depending on the flow conditions and the position within the core. Anyway, given the generic nature of the proposed approach, correlations following different formats could be tested. Preliminary results for the high-fidelity simulation of a fast MSR core are presented. The target Reynolds number is currently 20K, with the expectation that this will increase, pending the availability of further computational resources. These simulations will be used to inform lower fidelity models, including a coarse CFD turbulence model in Pronghorn. Additionally, they will serve as a reference for the RANS models in Nek5000/NekRS.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simple Heat Transfer Model for Film Cooling Applications

This report describes the development of a simple engineering model for film cooling. This model is used to derive a relationship between local wall temperature variations and key cooling performance parameters like local heat transfer coefficients and film effectiveness. This relation and method new and different from previously published models. The scope of this report includes the derivation of regression model equations for a flat plate with and without film cooling. The model equation for a flat plate without film cooling can be used to estimate local heat transfer coefficients using surface temperatures measured from infrared thermography. The model equation for the flat plate with film cooling can be used to estimate film cooling effectiveness, $η_f$, and heat transfer augmentation from the film cooling jet(s).

42 ENGINEERING↗

Challenge Problem 1: Preliminary Results of the Direct Numerical Simulation of Transient Flows

This report presents the first direct numerical simulations (DNS) of transient mixed convection in an idealized downcomer-like channel (Challenge Problem 1, Phase II). Using the GPU-accelerated NekRS solver, we modeled a sudden decay in driving pressure, mimicking loss-of-flow events, and tracked the resulting evolution of Reynolds number, boundary-layer structure, turbulence statistics, and heat-transfer metrics. Key findings include the systematic thickening and eventual asymmetry of velocity and thermal boundary layers under buoyant deceleration; minimal “memory” lag in Reynolds shear stress and TKE profiles when sampled at matching Re, yet clear shifts of peak locations toward the cooled wall; overshoots in transient eddy-viscosity and eddy-diffusivity (and corresponding sub-unity turbulent Prandtl numbers) on the cooled side; and a pronounced transient Nusselt-number enhancement driven by wall-temperature inertia and residual eddy mixing. These effects combined to offer a temporary cooling margin above steady-state predictions during reactor LOF transients. Future work will extend this work to a more complex “Case II” geometry (90° turn + lower plenum) and generate multi-Re/Pr datasets for data-driven turbulence closures.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Study of Propane Combustion in a Spark-Ignited Cooperative Fuel Research (CFR) Engine

Liquefied petroleum gas (LPG), whose primary composition is propane, is a promising candidate for heavy-duty vehicle applications as a diesel fuel alternative due to its CO 2 reduction potential and high knock resistance. To realize diesel-like efficiencies, spark-ignited LPG engines are proposed to operate near knock-limit over a wide range of operating conditions, which necessitates an investigation of fuel-engine interactions that leads to end-gas autoignition with propane combustion. This work presents both experimental and numerical studies of stoichiometric propane combustion in a sparkignited (SI) cooperative fuel research (CFR) engine. Engine experiments are initially conducted at different compression ratio (CR) values, and the effects of CR on engine combustion are characterized. A three-pressure analysis (TPA) model based on the two-zone combustion concept is developed in GT-Power and validated using test results to estimate in-cylinder wall temperatures, residual gas fraction, etc. This model is further utilized to examine end-gas chemistry by enabling the SI turbulent flame combustion and unburned gas chemical kinetics modules. Finally, a three-dimensional (3D) computational fluid dynamic (CFD) model of the CFR engine is developed in CONVERGE, where the G-equation and SAGE detailed chemical kinetics models are implemented for combustion modeling. Here, a 153 species reduced chemical kinetics mechanism derived from the detailed NUIGMech1.1 mechanism based on the ignition delay and laminar flame speed (LFS) studies is used to generate an LFS lookup table and to describe end-gas autoignition chemistry. Multi-cycle Reynolds-averaged Navier-Stokes (RANS) simulations are then performed for the tested CRs, and the numerical model is shown to be capable of predicting the propane combustion characteristics, particularly the end-gas autoignition behavior.

20 FOSSIL-FUELED POWER PLANTS↗

Pool boiling on metal-foam enhanced tube bundle: heat transfer characteristics and flow visualization

A flooded evaporator configuration is common in large central air conditioning or process cooling systems. It is basically a shell and tube heat exchanger, in which a secondary fluid (brine or water) circulates inside the tube bundle and is cooled by the vaporization of the refrigerant on the outside surface of the tubes. The enhanced pool boiling process enables the compact design of flooded evaporators, which substantially reduces the refrigerant charge. High-porosity metal foam, with a large surface-area-to-volume ratio, could provide an extended heat transfer area and a high-density of nucleation sites. This study experimentally investigated the pool boiling heat transfer and flow characteristics on metal-foam enhanced tube bundles. The enhanced bundle consists of four aluminum tubes with aluminum foam brazed around the outer surface, which are horizontally mounted in a staggered arrangement. The results showed that the metal-foam enhanced tube bundles improved the heat transfer coefficient by 100-160% with a lower wall temperature difference of 1-10°C, compared to the baseline. In addition, the tube pitch played a significant role in determining the pool boiling behavior of the tube bundles.

Yang, Cheng-Min↗

An intercomparison of wall fluxes in a turbulent thermal convection chamber: Direct numerical simulations and wall-modeled large-eddy simulations enhanced by machine learning

Thermal convection in a closed chamber is driven by a warm bottom, a cold top, and side walls at various temperatures. Although wall fluxes are the source of convection energy, accurately modeling these fluxes (i.e., the wall model) is challenging. In large-eddy simulations (LESs), many wall models are traditionally derived from the canonical boundary layer, which may be unsuitable for thermal convection bounded by both horizontal and vertical walls. This study conducts a model intercomparison of dry convection in a cubic-meter chamber using three direct numerical simulations (DNSs) and four LESs with different wall models. The LESs employ traditional wall models, a new wall model employing physics-aware neural networks, and a refined grid near the walls. The experiment involves four cases with varying sidewall temperatures. Our results show that LESs capture the main flow features and the trends of mean fluxes. The physics-aware neural networks and refined wall grids can improve the temporally averaged local fluxes when the large-scale circulation has a preferred direction. Even without the local improvement of wall fluxes, the LES flow quantities (temperature and velocities) can still largely match those in DNSs, provided the mean flux largely matches the DNSs. Additionally, DNSs reveal that a variation in corner treatments has minimal impacts on the flow quantities away from corners. Finally, LESs underestimate the mean fluxes of the entire wall due to their inability to resolve corner regions, but their mean flux away from the corner can better match DNS.

54 ENVIRONMENTAL SCIENCES↗

Low-temperature domain-wall freezing and nonequilibrium dynamics in the transverse-field Ising model material CoNb 2 O 6

CoNb 2 O 6 is a rare realization of the transverse-field Ising model, making it a useful tool for studying both equilibrium and nonequilibrium many-body quantum physics. Despite a large body of work dedicated to characterizing this material, details of the ordered states in the presence of relatively weak transverse fields have not been discussed in detail. Here, we present a detailed study of CoNb 2 O 6 via ac susceptibility measurements in order to further characterize its low-temperature behavior in the presence of a transverse field. Specifically, we call attention to an unconventional freezing transition in zero field below T F = 1.2 K, occurring within the well-known commensurate antiferromagnetic (CAFM) state that onsets at T N2 = 1.9 K. We performed a series of transverse-field quenches into this frozen state, which resulted in a slowly relaxing susceptibility, χ' (t), that followed a logarithmic decay within the time range measured. Additionally, we discuss the frozen state in the context of the freezing of previously discussed “free” chains arising from domain walls between the four degenerate sublattices of the CAFM state. We also attempted to observe Kibble-Zurek scaling by quenching the transverse field into the frozen state at different rates. This produced a null result; the behavior can be fully explained by coarsening of domains over the time scale of the quenches. The absence of a clear Kibble-Zurek scaling is itself surprising, given the proposed ubiquity of the phenomenon for general second-order phase transitions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analysis of thermal and mechanical properties with inventory level of the molten salt storage tank in central receiver concentrating solar power plants

Molten salt thermal energy storage (TES) tanks ensure steady power output of concentrating solar power (CSP) plants; however, recent tank failures have highlighted the need for further analysis. Current studies primarily focus on analyzing the molten salt flow, heat transfer, and thermal efficiency. Additionally, research on the latest tank structures is limited and lacks newest experimental validation. This study measures temperature and molten salt inventory levels in the high-temperature tank at a 50 MW central receiver CSP plant, connected to the power grid in 2019. A multi-physics model was developed to evaluate thermal and mechanical properties of TES tanks by combining computational fluid dynamics and finite element modeling using real plant data. Heat loss, temperature, displacement, and stress distribution of the tank at different inventory levels were investigated. Results show that ambient air velocity near the tank roof reaches 2.14 m/s, much higher than 0.2 m/s near the wall. The temperatures of inventory fluid and tank are close, varying slightly at different levels due to thermal conduction and radiation. Because the heat loss strongly depends on temperature, the total tank loss remains nearly constant across inventory levels. Larger temperature gradients and thermal stresses are primarily localized along the tank floor edge and the air-salt interface. Notably, the maximum thermal stress at the tank edge is three times higher than that at the interface. The magnitude of total stress changes by less than 5 MPa with and without thermal load, indicating that high temperatures exert only a minor impact on tank stress. In contrast, thermal load significantly affects tank deformation, particularly at the roof edge, where values exceed 150 mm. Despite the large variation in molten salt levels, tank wall temperatures and displacements present a minor change, suggesting a weak correlation with inventory levels. In conclusion, the findings obtained in this study provide important insights on the TES tank that could be used to optimize tank design and operation strategies.

14 SOLAR ENERGY↗

Analysis of precooling optimization for residential buildings

To reduce peak demand and/or energy cost for residential buildings, optimal precooling strategies are becoming important as an alternative to rule-based precooling strategies that are intuitive but may not be optimal. Since precooling optimization is heavily dependent on a variety of factors such as the home thermal properties, HVAC system, weather, thermal comfort criteria, and utility rate structure, the individual and collective impact of these factors on precooling performance needs to be analyzed. In addition, since the indoor air temperature is affected by heat transfer to and from the interior wall surface, performance analysis in view of the interior wall surface temperature is also essential. Therefore, in this paper, an optimal precooling strategy that accounts for the aforementioned factors and utilizes a second-order thermal network model, is proposed. With this strategy, the HVAC on/off control signal that minimizes 24-hour energy cost while maintaining thermal comfort, is determined. Through extensive simulations, it is found that the proposed optimal precooling strategy is able to adapt to changing conditions and that having a sufficiently low interior wall surface temperature during precooling is critical for avoiding expensive on-peak operation. Here, the reason for the latter is that such a temperature indicates that enough “cooling energy” has been stored. It is also found that weather has the most dominant impact on the precooling performance, followed by home thermal condition, with the rated cooling capacity and utility rate structure having the least impact.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of predicted mean vote-based model predictive control for residential HVAC systems

Model Predictive Control (MPC) is an advanced process control method that has attracted much attention in building heating, ventilation, and air conditioning (HVAC) systems. Here, this paper analyzes the optimal precooling performance in residential buildings using MPC with two different comfort indices, namely, temperature and predicted mean vote (PMV). It first formulates, for each comfort index, an optimization problem that accounts for different factors, such as weather, home thermal condition, prediction horizon, time-of use (TOU) utility rate, and rated cooling capacity. The problem is then solved, resulting in an MPC strategy that determines the HVAC on/off control signal and minimizes energy cost over a receding time horizon while maintaining thermal comfort. The energy performance difference between temperature-based and PMV-based MPC strategies is subsequently investigated, especially in light of the interior wall surface temperature and under different combinations of the factors. Extensive simulation results demonstrated that the proposed MPC strategies are adaptive and their performances depend primarily on weather, home thermal condition, and prediction horizon, while the impact of TOU utility rate and rated cooling capacity is relatively small. Because the PMV-based MPC strategy can take advantage of the lower interior wall surface temperature due to precooling, it resulted in 8–45% cost savings for the scenarios investigated and an average increase of 0.042–0.113 in the absolute value of the PMV index compared to the temperature-based MPC strategy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Calculation of the Heat Transfer Coefficient in the Outer Body for a Rotational Detonation

Unsteady heat transfer characterization on the combustion surfaces of Rotational Detonation Engines (RDE) is not well understood. It is generally thought that the complex nature of the unsteady, reacting, compressible fluid flow inside the combustion anulus of the RDE causes the convective heat transfer coefficient to be significantly higher than it is in other applications. Empirical models that have been used to analyze this strictly apply to steady flows where dimensionless groups can be employed. The reacting flow fields that are characteristic of RDEs are inherently compressible, three dimensional, unsteady, and turbulent, having properties that change by orders of magnitude throughout the flow field. They will therefore contain multiple length scales and time scales operating everywhere in the flow during all times. Because of this it is not likely that the RDE flow fields will lend themselves to explanation using simple dimensionless parameters. The dimensionless groups have meaning only in situations where length scales and time scales are singular and well defined. In spite of this it may be possible to get a relatively good idea of what the convection heat transfer coefficient is. In this work a numerical study is performed where the inside wall surface temperature distribution in the RDE outer body is systematically changed over a given range that would be characteristic of the start-up flows inside an RDE. For each case, temperature distributions inside the outer containment wall of the RDE was calculated and compared with experimental data. The closet match can then be used to directly calculate the convection heat transfer coefficient on the inside surface of the RDE.

VanOsdol, John↗

Responses of the Plant Cell Wall to Sub-Zero Temperatures: A Brief Update

Our general understanding of plant responses to sub-zero temperatures focuses on mechanisms that mitigate stress to the plasma membrane. The plant cell wall receives comparatively less attention, and questions surrounding its role in mitigating freezing injury remain unresolved. Despite recent molecular discoveries that provide insight into acclimation responses, the goal of reducing freezing injury in herbaceous and woody crops remains elusive. This is likely due to the complexity associated with adaptations to low temperatures. Understanding how leaf cell walls of herbaceous annuals promote tissue tolerance to ice does not necessarily lead to understanding how meristematic tissues are protected from freezing by tissue-level barriers formed by cell walls in overwintering tree buds. In this mini-review, we provide an overview of biological ice nucleation and explain how plants control the spatiotemporal location of ice formation. We discuss how sugars and pectin side chains alleviate adhesive injury that develops at sub-zero temperatures between the matrix polysaccharides and ice. The importance of site-specific cell-wall elasticity to promote tissue expansion for ice accommodation and control of porosity to impede ice growth and promote supercooling will be presented. How specific cold-induced proteins modify plant cell walls to mitigate freezing injury will also be discussed. The opinions presented in this report emphasize the importance of a plant’s developmental physiology when characterizing mechanisms of freezing survival.

59 BASIC BIOLOGICAL SCIENCES↗

A Phenomenological Thermal Spray Wall Interaction Modeling Framework Applied to a High Temperature Ignition Assistant Device

Airborne compression ignition engines must operate with reliable ignition systems to achieve proper ignition at every cycle, particularly at high altitudes. Glow-plug-based ignition-assistant (IA) devices can provide the necessary energy to preheat the fuel and ensure ignitability of the fuel-air mixture. Ignitability of liquid sprays can be facilitated via direct impingement onto the hot IA surface, however this comes with adverse effects on the IA durability. Therefore, optimizing an IA’s design requires detailed understanding of the physics of fuel spray impingement of superheated surfaces. While spray impingement on relatively low wall temperatures has been extensively studied and appropriate numerical models have been proposed through the years, fundamental understanding of high-speed liquid spray impingement on superheated walls is still elusive. This work aims to formulate a phenomenological thermal spray-wall interaction framework for modeling the film-boiling-induced heat transfer, atomization, and dispersion of fuel spray droplets impinging onto a superheated IA device. A qualitative comparison of the new phenomenological model is performed against optical experiments from the literature of an F-24 fuel spray injected onto an IA device located 12 mm away from the injector tip. The temperature of the IA was set at 1400 K. The fuel injection pressure was 400 bar, while the ambient gas pressure and temperature were 30 bar and 800 K, respectively. The performance of the phenomenological model is evaluated in comparison with two other state-of-art models from the literature. A qualitative analysis of the different spray and fuel-air mixture characteristics is performed to outline the differences in the predictions offered by the new phenomenological model and the two state-of-art spray-wall interaction models.

droplet dispersion↗

Heat transfer model for moving packed-bed particle-to-sCO 2 heat exchangers integrated with metal foams

Particle-to-supercritical carbon dioxide (sCO 2 ) heat exchangers (HXs) play a vital role in coupling heat transfer fluid (HTF) from high-temperature thermal receivers to power cycle working fluids (WF). Heat transfer enhancement is essential for adopting particle-based moving packed-bed heat exchangers (MPBHXs) in next-generation thermal energy storage (TES) systems, as MPBHXs usually exhibit low particle bed-to-wall heat transfer coefficients. High-porosity metal foams have shown their effectiveness in heat transfer enhancement. Here, this work presents a continuum heat transfer model to demonstrate the heat transfer enhancement in MPBHXs when the particle bed channel is filled with high porosity metal foams compared to open channel MPBHXs. The presence of metal foams increases the effective thermal conductivity in the particle channel and enhances the interstitial heat transfer coefficient between the moving particle bed and the stationary metal foams. The present model considers coupled two-dimensional (2D) heat transfer in the particle channel with metal foams and 1D heat transfer in the sCO 2 channel and the dividing wall. The temperature profiles for the particle bed, metal foam, dividing wall, and sCO 2 stream, as well as the local heat flux profiles between those, are studied in detail for various foam porosities, from which the particle bed-to-wall heat transfer coefficient, overall heat transfer coefficient, and total heat transfer rate for the MPBHX are determined. The effects of major MPBHX design and operating parameters on the particle bed-to-wall heat transfer coefficient and overall heat exchange capacity are thoroughly examined; thus, the MPBHX performance improvement with metal foams is quantified for each case. The present heat transfer model can provide valuable insights into the metal-foam MPBHX design and optimization, scale-up, and operating parameters selection.

42 ENGINEERING↗

Assessment of RELAP5-3D Code with Molten Salt Heat Transfer Experiments

The accurate thermal-hydraulic assessment of thermal storage systems is crucial for addressing the integrity and performance of the storage system design. This is particularly important for thermal storage systems using molten salts as a heat transport and storage medium, as the chemical corrosion and erosion by the high-temperature molten salts can cause serious damage to the structural components of the storage system. To understand these effects for TerraPower’s Natrium® Demonstration Reactor design, the system thermal-hydraulic analysis code, RELAP5-3D, is utilized to analyze the thermal storage system. This study evaluates two heat transfer correlations implemented in the RELAP5-3D code—the Dittus-Boelter and Gnielinski correlations—using selected benchmark cases from two molten salt heat transfer experiments conducted at Xi’an Jiao Tong University and the German Aerospace Center. The Nusselt numbers calculated using the Gnielinski correlation agree with the experimental data within ±5% of the relative deviations at 300°C and 400°C. With the increasing Reynolds numbers, the Dittus-Boelter correlation underestimates the Nusselt numbers by up to 22% compared to the Gnielinski correlation. Comparison of the RELAP5-3D calculation results with experimental data at a high temperature of 550°C revealed that the thermo-chemical characteristics of solar salt at high temperatures surpassing the decomposition temperatures of nitrate salts reduce the accuracy of heat transfer model of the RELAP5-3D code. Specifically, it has been observed that the temperatures of the wall surface and liquid near the wall can surpass the decomposition temperatures, even though the bulk temperature of molten salts remains significantly lower than these decomposition temperatures. In summary, this study recommends the use of the Gnielinski correlation for the heat transfer analysis of molten salt, rather than the Dittus-Boelter correlation.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗