International Actions to Reduce Miscellaneous Electrical Loads Energy Consumption

Miscellaneous electric loads (MELs) research dates back over 30 years, with the earliest publications about MELs originating in the late 1980s. As the number and types of MELs have grown during the intervening decades, so has the body of minimum energy performance standards (MEPS) and regulations put in place to control what is now a significant energy end use in the residential and commercial sectors. In particular, these MEPS are designed to control off-mode, standby, and connected standby power consumption to prevent energy waste. Research on MELs focuses a great deal on analyzing the characteristics of MELs, approaches for measuring their consumption, and at a higher level what constitutes a MEL. Despite these advances, there have been few comparisons of different approaches to curtail MELs energy consumption across regulatory bodies of MELs—both between and within countries—to identify similarities, gaps, and opportunities for crafting common language and standards. This study provides an analysis of international MELs-related voluntary and mandatory MEPSs across 12 economies to address this gap. The analysis demonstrates that although economies may share the commitment to regulate the energy consumption of MELs, there still is no common language for framing MELs, nor is there a shared understanding for harmonizing MEPS for MELs.

Butzbaugh, Josh↗

Engineered Nanoporous Frameworks for Adsorption Cooling Applications

The energy demand for traditional vapor-compressed technology for space cooling continues to soar year after year due to global warming and the increasing human population’s need to improve living and working conditions. Thus, there is a growing demand for eco-friendly technologies that use sustainable or waste energy resources. Here this review discusses the properties of various refrigerants used for adsorption cooling applications followed by a brief discussion on the thermodynamic cycle. Next, sorbents traditionally used for cooling are reviewed to emphasize the need for advanced capture materials with superior properties to improve refrigerant sorption. The remainder of the review focus on studies using engineered nanoporous frameworks (ENFs) with various refrigerants for adsorption cooling applications. The effects of the various factors that play a role in ENF–refrigerant pair selection, including pore structure/dimension/shape, morphology, open-metal sites, pore chemistry and possible presence of defects, are reviewed. Next, in-depth insights into the sorbent–refrigerant interaction, and pore filling mechanism gained through a combination of characterization techniques and computational modeling are discussed. Finally, we outline the challenges and opportunities related to using ENFs for adsorption cooling applications and provide our views on the future of this technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Work Smarter, Not Harder: Improving Energy Efficiency and Safety through Smarter Ventilation: Preprint

Ventilation is a key component to maintaining healthy, safe indoor air quality. Especially important in laboratories, ventilation is the first line of defense against airborne hazards produced during research activities. Though a vital component, laboratory ventilation systems are often victim to ineffective operation, posing a risk to the most important asset - the researchers. Furthermore, system inefficiencies can lead to up to 50% wasted energy. To improve both energy efficiency and safety in laboratories, we present the Smart Labs Toolkit - a resource developed by the U.S. Department of Energy Federal Energy Management Program and the International Institute for Sustainable Laboratories that guides laboratory stakeholders through a straight-forward, holistic approach to achieve dynamic, high-performance laboratories. Smart Labs enable safe and efficient world class science to occur in laboratories through high-performance methods. A Smart Labs program employs a combination of physical, administrative, and management techniques to assess, optimize, and manage high performance laboratories. We will focus on a central component of the Smart Labs approach - the Laboratory Ventilation Risk Assessment, a systematic process for identifying risk due to airborne hazards to inform the operation of dynamic ventilation that optimizes safety and efficiency. Case studies of organizations who have successfully implemented Smart Labs ventilation management programs will also be shared. In learning ventilation strategies successful in critical laboratory environments, learn the tools and resources needed to successfully manage energy in any building through smarter, safer ventilation.

buildings↗

Energy impact of heating electrification in mid-rise multifamily buildings in mixed-humid climates

Decarbonizing the electric grid in conjunction with electrifying residential heating is a critical step to combat climate change. Heating in multifamily buildings with the existing natural gas-fired central boiler is a complex process that not only leads to overheating in some apartment units but also results in energy waste and high gas bills. In this study, we consider a multifamily building in New York City, USA, to evaluate the performance of five different heating systems, which represent a step-by-step transition from the conventional to a fully electrified heating system, and determine their impact on the site energy consumption and source CO 2 emissions. Results indicate that overheating in a multifamily building can raise the indoor temperature by as much as 8°C above comfortable limits. Transitioning from conventional steam radiators to cold climate heat pumps can reduce annual site heating energy by up to 70% and source CO 2 emissions by up to 21%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aniak Energy Efficiency Retrofit Project

The Native Village of Aniak (NVA), a federally recognized Yup'ik Tribe, undertook this energy efficiency initiative to enhance energy performance in key community buildings, including the Tribal Office, Community Center, Duplex, and Association of Village Council Presidents (AVCP) Office. Through energy audits and upgrades, the project focused on high-impact improvements like air sealing, LED lighting, and programmable thermostats, primarily in the Tribal Office due to funding constraints. The initiative aimed to reduce energy waste, lower heating and electricity costs, and improve facility comfort and longevity while achieving long-term savings for further improvements by decreasing reliance on imported fuel oil. Despite scope limitations exacerbated by budget constraints, this project achieved an approximately 52% reduction in EUI. Reducing operational costs emphasizes economic and environmental benefits, aligning closely with Aniak's broader energy sustainability objectives. This initiative aligned with the Tribe's vision for responsible energy use, addressing the challenges of high fuel prices in a remote community; it could serve as a model for similar efforts in Aniak and other Alaska Native villages pursuing energy self-reliance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of thermostat location for multizone commercial building performance

In multi-zone buildings, it is often found that a single shared thermostat controls more than one conditioned zones. Although these shared zones are supposed to have similar thermal needs (e.g., cooling and heating load), in reality, they are not mainly due to different orientations, sizes of windows, occupancy, space types, etc. This can cause unnecessary energy waste or thermal discomfort for the occupants. How to quantify this impact in multizone buildings remains a research gap. Therefore, this study aims to evaluate the impact of different sensor (i.e., thermostat) locations for multizone commercial buildings through a comprehensive modeling study. Here, two different scenarios for the sensor locations were selected to evaluate the impact in terms of energy and thermal comfort. The scenario (1) is that one to five sensors distributed among the five zones, but the sensor readings from selected zones will be used for no-sensor zones, which is no-mean sensor scenario. The scenario (2) is that one to five sensors distributed among the five zones, but the average temperature from the shared zones will be used for each of the shared zones, which is a mean sensor scenario. The uncertainty analysis was performed for different sensor location scenarios.(a)The major findings from an energy perspective, for scenario (1), the differences of cooling energy go as high as 17% more or 12% less, compared with the baseline. For heating energy consumption, the discrepancies go as high as 51% more or 52% less, compared with baseline. For site energy consumption, the discrepancies go as high as 3.2% more or 3.2% less, compared with baseline. For fan energy consumption, the discrepancies go as high as 3.2% more or as low as 1.0% less, compared with baseline. For scenario (2), the discrepancies of cooling energy go as high as 3% more, or 0.5% less, compared with the baseline. For heating energy consumption, the discrepancies, are go as high as 10.1% more or as low as 3.0% less, compared with baseline. For site energy consumption, the discrepancies go as high as 1.3% more or 0.3% less, compared with baseline. For fan energy consumption, the discrepancies go as high as 3.1% more or as low as 1.0% less, compared with baseline.(b) In terms of the indoor thermal comfort, for the no-mean-sensor scenarios, the discrepancies of unmet hours for cooling mode can be as high as 1,200 h, compared with the baseline. The discrepancies of unmet hours for heating mode can be as high as 740 h, compared with the baseline. For the mean-sensor scenarios, the discrepancies of unmet hours for cooling mode can be as high as 750 h, compared with the baseline. The discrepancies of unmet hours for heating mode can be as high as 50 h, compared with the baseline.

42 ENGINEERING↗

Leveraging Fine-Grained Occupancy Estimation Patterns for Effective HVAC Control

As occupancy sensing technologies become mature, various occupancy sensors are increasingly deployed in commercial buildings for pervasive occupancy monitoring. These sensors provide occupant-count data, which contains rich spatiotemporal information about occupancy patterns. With long-term occupant-count data collected from a commercial building, we design three different predictive models that capture the occupancy dynamics and examine how a model predictive control of the HVAC system benefits from actual occupancy count prediction. Our analysis reveals that mispredictions of occupancy states, especially false positives and false negatives, may introduce inefficient control that leads to energy waste or user discomfort. To address this issue, we take a step further to design an adaptive model predictive controller that minimizes inefficient control actions according to misprediction types and distributions. A comprehensive evaluation is performed in OpenBuild and EnergyPlus simulators to study the effectiveness of the proposed end-to-end control strategy. The evaluation shows that the proposed solution reduces energy consumption by 29.5% while improving the average weighted occupants comfort by 86.7% in Predicted Mean Vote (PMV) over the fixed schedule strategy.

97 MATHEMATICS AND COMPUTING↗

Carbon Dioxide Utilization Life Cycle Analysis Guidance for the U.S. DOE Office of Fossil Energy and Carbon Management (Version 2.0)

Capturing carbon dioxide (CO 2 ) and placing it in permanent storage in geologic formations is an option for reducing CO 2 emissions, but it may not be a viable one for all CO 2 emitters. For some, the added cost of capture may be too high to implement, or the geology near the source may not be suitable for storage. In these circumstances, other options will be needed. Carbon use and reuse, or CO 2 utilization (CO2U), is an alternative approach that seeks beneficial uses for captured CO 2 , such as using it as a feedstock in the production of fuels, chemicals, and building materials. These uses would give CO 2 value that could be used by suppliers (emitters) to offset capture costs. One of the principal features and challenges associated with CO2U is that the products derived from CO 2 must have lower carbon footprints than their conventional counterparts. Previous assessments of CO2U alternatives have focused on the carbon content of utilization products as an indicator of CO 2 equivalent (CO 2 e) emissions reduction potential. However, embodied emissions are—at best—only weakly correlated with the amount of carbon contained in any physical product. Therefore, the most attractive CO2U options will both displace the carbon in an existing product and improve the overall carbon efficiency of the manufacturing process. Research to overcome barriers will include identifying existing co-feeds and available low-carbon energy sources to enable the conversion of CO 2 to value-added products under favorable processing conditions. New discoveries in the fields of nano- and bio-technology will be applied to efficiently utilize CO 2 in new applications. Development of advanced materials and processes, integrating CO 2 capture with utilization processes (e.g., algae), exploring a diverse slate of products from CO 2 to effectively offset capture costs and developing processes based on waste energy are means to overcome these barriers. The research will lead to the development of advanced catalysts, materials, and equipment that can be used to convert CO 2 into useful products. The result will be multiple flexible and adaptable technology platforms that can be used to produce suites of products spanning multiple utilization pathways.

54 ENVIRONMENTAL SCIENCES↗

FY 2022 Site Sustainability Plan

The United States Department of Energy's (DOE's) National Renewable Energy Laboratory (NREL) is a recognized leader in sustainability, as evidenced by its ongoing optimization of resources in campus operations, including water, energy, waste, and purchasing, as well as continued commitment to meeting federal mandates and goals. NREL's dedication to sustainability supports the laboratory's success by applying what is learned through research and development to campus facilities and infrastructure systems. The Site Sustainability Plan provides a road map for all site planning and development. NREL drives the adoption of these initiatives to a global audience by conducting business operations that demonstrate the incorporation of clean energy practices. NREL will continue to develop a sustainable and resilient campus while growing greater technological capabilities to advance the national renewable energy marketplace.

climate change↗

Ibis Networks/WattIQ (IN2 Final Report)

Ibis Networks is a full-stack cleantech company that provides plug-level energy monitoring and control to solve energy and asset management problems for the enterprise. During DATES – DATES, an NREL research team worked with the Ibis team to validate their product, the InteliSocket. The Ibis InteliSocket is a pass-through plug-load energy monitor and controller that is designed to reduce energy wasted by common 120 V plug-in devices in commercial office buildings, such as computer peripherals, conference room AV equipment, and break-room appliances. The system can shut off supply power to these end uses via remote control, manual switches, pre-set schedules, or automated control algorithms. The scope of this IN2 project was the development and refinement of “smart” learning behavior algorithms (LBAs), which could help installation processes and dramatically expand the sockets’ capabilities and energy-saving potential by suggesting suitable control schedules that are based on monitored use patterns. While Ibis has the analytical and software expertise for algorithm development, the lack of test data, both in a controlled laboratory setting and in real-life deployment scenarios, represented a key barrier toward commercialization of the product. Assistance through the IN2 program provided an opportunity to conduct the needed “trial and error” algorithm development. The project included baseline field-data collection, laboratory testing, and field validation components, all of which were conducted at the NREL campus between April 2017 and July 2019.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The De-Icing Comparison Experiment (D-ICE): a study of broadband radiometric measurements under icing conditions in the Arctic

Abstract. Surface-based measurements of broadband shortwave (solar) and longwave (infrared) radiative fluxes using thermopile radiometers are made regularly around the globe for scientific and operational environmental monitoring. The occurrence of ice on sensor windows in cold environments – whether snow, rime, or frost – is a common problem that is difficult to prevent as well as difficult to correct in post-processing. The Baseline Surface Radiation Network (BSRN) community recognizes radiometer icing as a major outstanding measurement uncertainty. Towards constraining this uncertainty, the De-Icing Comparison Experiment (D-ICE) was carried out at the NOAA Atmospheric Baseline Observatory in Utqiaġvik (formerly Barrow), Alaska, from August 2017 to July 2018. The purpose of D-ICE was to evaluate existing ventilation and heating technologies developed to mitigate radiometer icing. D-ICE consisted of 20 pyranometers and 5 pyrgeometers operating in various ventilator housings alongside operational systems that are part of NOAA's Barrow BSRN station and the US Department of Energy Atmospheric Radiation Measurement (ARM) program North Slope of Alaska and Oliktok Point observatories. To detect icing, radiometers were monitored continuously using cameras, with a total of more than 1 million images of radiometer domes archived. Ventilator and ventilator–heater performance overall was skillful with the average of the systems mitigating ice formation 77 % (many >90 %) of the time during which icing conditions were present. Ventilators without heating elements were also effective and capable of providing heat through roughly equal contributions of waste energy from the ventilator fan and adiabatic heating downstream of the fan. This provided ∼0.6 ∘C of warming, enough to subsaturate the air up to a relative humidity (with respect to ice) of ∼105 %. Because the mitigation technologies performed well, a near complete record of verified ice-free radiometric fluxes was assembled for the duration of the campaign. This well-characterized data set is suitable for model evaluation, in particular for the Year of Polar Prediction (YOPP) first Special Observing Period (SOP1). We used the data set to calculate short- and long-term biases in iced sensors, finding that biases can be up to +60 W m−2 (longwave) and −211 to +188 W m−2 (shortwave). However, because of the frequency of icing, mitigation of ice by ventilators, cloud conditions, and the timing of icing relative to available sunlight, the biases in the monthly means were generally less than the aggregate uncertainty attributed to other conventional sources in both the shortwave and longwave.

54 ENVIRONMENTAL SCIENCES↗

Open Building Control

Best practice control sequences are often not implemented correctly, or are not implemented at all, in large commercial buildings. This typically leads to 10-30 percent energy waste, along with reduced occupant productivity and unnecessary equipment wear. The current process of designing and implementing such control sequences is a manual process that starts with designers who often don’t have adequate training, then requires controls programmers to interpret and program a verbose written sequence. This process has been shown to fail to deliver high performance control sequences at scale. The Open Building Control project digitizes the current control delivery process. The project is developing tools for system designers to select control sequences, assess their energy performance and load flexibility potential using whole building simulation, specify the sequence for implementation using machine-to-machine translation by a control provider and formally testing the as-installed sequences by a commissioning agent. The project developed tools for each stage of this delivery process. The key innovation of the project is the development of the Control Description Language, a language that allows such a digitized control delivery process with end-to-end verification. Libraries of control sequences have been implemented using the Control Description Language, and their performance has been demonstrated using whole building energy simulation. An automated translation of such sequences to a commercial control product line has been conducted using a prototype translator. Tools for formal verification of as-installed control sequences relative to their specification have been developed and demonstrated. The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) started the process of forming a committee to make this language an ASHRAE/ANSI Standard. This new standard will complement existing and emerging ASHRAE standards for building communication and semantic modeling by providing a standard for expressing the control logic - the actual brain of the building. We expect this language and the process it enables to be an important contribution to the deployment of high performance building control sequences at scale because it allows taming the complexity of the control delivery process, which is continually increasing due to the need for higher performance and increased load flexibility to meet goals for net zero energy and increased renewable integration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

International Actions to Reduce Miscellaneous Electrical Loads Energy Consumption

Miscellaneous electric loads (MELs) research dates back over thirty years, with the earliest publications on MELs originating in the late 1980s. As the number and types of MELs grew over the subsequent decades, so did the body of minimum energy performance standards (MEPS) and regulations put in place to control what is now an ever-growing source of energy consumption in the residential and commercial sectors. In particular, these MEPS are designed to control off-mode, standby, and connected standby power consumption to prevent energy waste. Research on MELs focuses a great deal on analyzing the characteristics of MELs, approaches for measuring their consumption, and at a higher level what constitutes a MEL. Despite these advances, there has yet to be a comparison of different approaches across regulatory bodies of MELs – both between and within countries – to identify similarities, gaps, and opportunities for crafting common language and testing procedures. This study provides an international analysis of MELs-related voluntary and mandatory MEPS across 12 economies to address this gap. The analysis demonstrates that even while economies may participate in shared commitments to regulated MELs energy consumption, there remains no common language for framing MELs, nor is there a shared understanding of updating aging test procedures used globally for verifying MELs-related MEPS.

Miscellaneous Electric Loads, MELs, Appliance and ↗

Barriers to Broader Utilization of Fault Detection Technologies for Improving Residential HVAC Equipment Efficiency

Faults in residential heating, ventilating, and air conditioning (HVAC) equipment may occur due to poor installation practices or develop over time, and these faults can negatively impact system efficiency, thermal comfort, and equipment lifespan. Automated fault detection and diagnostic (AFDD) technologies identify energy wasting HVAC faults, such as low indoor airflow and improper refrigerant charge, and guide technicians in improving system efficiency. For residential HVAC, AFDD consists of a range of fault detecting and diagnostic capabilities, sensor configurations, and target applications. AFDD technology can either be permanently installed by the original equipment manufacturer (OEM) using embedded sensors or as an add-on product either during or after installation. Additionally, several advanced installation tools and refrigerant gauge sets include AFDD features for temporary use during equipment installation and tune-ups. Some technologies can detect a fault but have limited diagnostic capabilities. For example, a single-point measurement from the home's thermostat or energy monitor can provide certain fault detection capability by analyzing the equipment runtime or energy consumption. These technologies, though limited at determining the cause of a given fault, may have significant energy savings potential due to their low cost and prevalence in the residential HVAC market. Despite the potential benefits, fault detection technologies face many technical and market barriers preventing broad adoption. Beyond the cost barriers due to the added sensor requirements and technology development, fault detection technologies face many implementation and adoption barriers such as installer training, customer awareness, standardized communication protocols, and methods of test for evaluating accuracy. The purpose of this whitepaper is to characterize market and technical barriers impeding broader utilization of fault detection technology for residential HVAC energy efficiency applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BETO 2021 Peer Review - 1.3.5.270 - Rewiring Algal Carbon Energetics for Renewables (RACER)

Critically needed improvements in biomass and biofuel intermediate productivity can be made by addressing fundamental inefficiencies in algal carbon conversion efficiency (CCE) to biofuel intermediates. Algae photosynthesis is, at best, able to convert 5-7% of incident light energy to biomass, while conversion to fuel intermediates falls 15-25% short of its maximum potential due to inefficiencies along the pathways. Recent progress in the Rewiring Algal Carbon Energetics (RACER) project consortium focused on a means to address the above inefficiencies in a pathway from algal biomass to a trifecta of fuel intermediates, ethanol, 2,3-butane diol, lipids and green biocrude. This project engineered a production-relevant algal species Desmodesmus armatus (SE 00107), to demonstrate biomass productivity improvements, with a doubling of the fuel intermediate yields. The new algae biorefinery paradigm embodied in RACER opens opportunities for algae engineering beyond efforts typically targeted solely at lipid content or improved light harvesting efficiency. Parallel approaches showed improved CCE through elimination of wasted energy during photosynthesis and increased carbon flux to transitory carbohydrate storage in the cells. Outdoor operation and nutrient management strategies with improvements in pretreatment, fermentation and extraction in a Combined Algal Processing approach showed a 40% reduction in MFSP, with a combined biofuel productivity of > 3700 gal/acre.

algal↗

Abstract for CRADA among NETL, Ohio University, and MetalKraft Technologies, LLC

The electrical grid faces challenges for meeting accelerated electricity demand arising from the electrification of building and transportation sectors. According to the DOE Grid Development Office, 70% of transmission lines are approaching the end of their lifecycle. The aging grid and insufficient transmission capacity necessitate the development of new technologies to improve overall grid performance. The conventional conductors used for electrical transmission lines suffer from substantial energy losses, high costs and low durability. These inefficiencies result in higher operational costs, increased energy waste, and difficulties in managing power flow. Improving the grid will require metals and composites with higher electrical conductivity and strength than the materials currently used. This CRADA will develop technologies to improve the grid by fabricating carbon metal composites with improved electrical, structural, and mechanical properties in comparison to metals that do not contain carbon additives. The composites will be made by incorporating carbon materials (graphite, graphene) into aluminum, copper, and other metals. The work will focus primarily on improving material properties that enhance the performance of these materials in electrical conductor applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

IceNet for FireBox - A Berkeley Warehouse-Scale Computer

Berkeley’s FireBox is a next-generation warehouse-scale computer (WSC) that utilizes the energy-efficiency and bandwidth density of integrated silicon-photonic interconnects to enable a new high-bandwidth and low-latency network fabric connecting thousands of compute nodes to petabytes of DRAM and Flash storage. The high bandwidth, low latency and high connectivity of FireBox’s WSC network fabric (IceNet) will enable dramatic improvements in the overall system energy efficiency enabling fine-grain power control on system resources (processors, links and memory/storage components). IceNet is a special 3-stage photonic Clos network architected to achieve ultra-low-latency connectivity between processor nodes and memory, drastically cutting down on the energy wasted in resource idling (processors and memory stalled due to pending network requests). This is achieved by integration of the first and last switch stages into processor/memory hub clients and by heavy over-provisioning of the high-radix middle switches (FlareSwitches). A key hardware component developed in this program is an active laser power management photonic integrated circuits called LightSpark. It interacts with the FlareSwitch and provides laser power to a subset of occupied switch ports, increasing the utilization of laser light in the photonic network by an order of magnitude. In addition to guiding the laser power where it is needed, the laser-power management module enables both wavelength and laser redundancy, significantly increasing the robustness of the system. The goal of the IceNet fabric is to enable communication between 1000s of processor nodes and PBs of memory/storage with <100ns latency, <10pJ/b wall-plug energy cost at multiple Pb/s of available connectivity bandwidth. These metrics represent two-orders of magnitude improvement with respect to the status of current data-center technology.

42 ENGINEERING↗