Search NASA⌕ Search

SEARCH · Search NASA

Results for “Waveform Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Analysis of GEOS-3 altimeter data and extraction of ocean wave height and dominant wavelength

When the amplitude and timing biases are removed from the GEOS-3 Sample and Hold (S&H) gates, the mean return waveforms can be excellently fitted with a theoretical template which represents the convolution of: (1) the radar point target response; (2) the range noise (jitter) in the altimeter tracking loop; (3) the sea surface height distribution; and (4) the antenna pattern as a function of the range to mean sea level. Several techniques of varying complexity to remove the effect of the tracking loop jitter in computing the wave height are considered. They include: (1) realigning the S&H gates to their actual positions with respect to mean sea level before averaging; (2) using the observed standard deviation on the altitude measurement to remove the integrated effect of the tracking loop jitter, and (3) using a look-up table to correct for the expected value of range noise. Analysis of skewness in the GEOS return waveform demonstrates the potential of a satellite radar altimeter to determine the dominant wavelength of ocean waves.

Walsh, E. J.↗

Ultrasonic spectrum analysis using frequency-tracked gated RF pulses

A new method of ultrasonic frequency analysis is introduced which employs frequency-tracked gated RF drive pulses rather than shock-excited broadband spikes to generate the ultrasonic waveform. The new technique, a variation of the sampled-continuous wave technique, eliminates problems associated with finite pulse widths of conventional methods. It is shown to yield correct ultrasonic wave velocity measurements of the sample irrespective of receiver gate width or position provided any portions of two successive echoes are gated simultaneously into the spectrum analyzer. The experimental observations are substantiated by a theoretical model based on the time-frequency domain formulation of ultrasonic frequency analysis.

Cantrell, J. H., Jr.↗

Apparatus Characterizes Transient Voltages in Real Time

The figure shows a prototype of a relatively inexpensive electronic monitoring apparatus that measures and records selected parameters of lightning-induced transient voltages on communication and power cables. The selected parameters, listed below, are those most relevant to the ability of lightning-induced transients to damage electronic equipment. This apparatus bridges a gap between some traditional transient-voltage recorders that record complete waveforms and other traditional transient-voltage recorders that record only peak values: By recording the most relevant parameters and only those parameters this apparatus yields more useful information than does a traditional peak-value (only) recorder while imposing much smaller data-storage and data-transmission burdens than does a traditional complete-waveform recorder. Also, relative to a complete-waveform recorder, this apparatus is more reliable and can be built at lower cost because it contains fewer electronic components. The transients generated by sources other than lightning tend to have frequency components well below 1 MHz. Most commercial transient recorders can detect and record such transients, but cannot respond rapidly enough for recording lightning-induced transient voltage peaks, which can rise from 10 to 90 percent of maximum amplitude in a fraction of a microsecond. Moreover, commercial transient recorders cannot rearm themselves rapidly enough to respond to the multiple transients that occur within milliseconds of each other on some lightning strikes. One transient recorder, designed for Kennedy Space Center earlier [ Fast Transient-Voltage Recorder (KSC- 11991), NASA Tech Briefs, Vol. 23, No. 10, page 6a (October 1999)], is capable of sampling transient voltages at peak values up to 50 V in four channels at a rate of 20 MHz. That recorder contains a trigger circuit that continuously compares the amplitudes of the signals on four channels to a preset triggering threshold. When a trigger signal is received, a volatile memory is filled with data for a total time of 200 ms. After the data are transferred to nonvolatile memory, the recorder rearms itself within 400 ms to enable recording of subsequent transients. Unfortunately, the recorded data must be retrieved through a serial communication link. Depending on the amount of data recorded, the memory can be filled before retrieval is completed. Although large amounts of data are recorded and retrieved, only a small part of the information (the selected parameters) is usually required. The present transient-voltage recorder provides the required information, without incurring the overhead associated with the recording, storage, and retrieval of complete transient-waveform data. In operation, this apparatus processes transient voltage waveforms in real time to extract and record the selected parameters. An analog-to-digital converter that operates at a speed of as much as 100 mega-samples per second is used to sample a transient waveform. A real-time comparator and peak detector are implemented by use of fast field-programmable gate arrays.

Medelius, Pedro↗

Observations from Long-Term Performance Monitoring of the TOPEX Radar Altimeter

From its August 1992 launch to the present, we have performed performance analysis and engineering assessment for the TOPEX radar altimeter. We continually update databases containing: (1) on-board engineering parameters such as temperatures, voltages, and currents; (2) internal calibration mode indications of bias changes in range and power estimates; and (3) global over-ocean averages of geophysical quantities such as significant waveheight (SWH) and ocean surface radar backscattering cross-section (sigmaO). For some time now we have seen an apparent increase in the TOPEX cycle-average SWH, amounting now to an increase of about 10% from our earlier mission value of about 2.8 m. Recently several investigators have reported that the TOPEX SWH is increasing relative to ERS-2 and to ocean buoy measurements. We examined the past six years of waveform data from an internal calibration mode (Cal 1) which samples the altimeter's point target response (ptr), and found that the ptr sidelobes are apparently greater now than at start of mission. Modeling studies indicate that the sidelobe enhancement can account for most of the increase in the TOPEX SWH estimate; that is, the SWH increase is not real but result of some drift within the altimeter. Our modeling indicates that the TOPEX range estimates will change less than a centimeter for ptr changes seen to date. An approximate recipe for correcting the TOPEX SWH values will be made available on our web site (http://topex.wffnasa.gov/). We emphasize that a radar altimeter is a complex system requiring continuing calibration and monitoring throughout its entire lifetime.

Hayne, G. S.↗

Design of FIR digital filters for pulse shaping and channel equalization using time-domain optimization

Three algorithms are developed for designing finite impulse response digital filters to be used for pulse shaping and channel equalization. The first is the Minimax algorithm which uses linear programming to design a frequency-sampling filter with a pulse shape that approximates the specification in a minimax sense. Design examples are included which accurately approximate a specified impulse response with a maximum error of 0.03 using only six resonators. The second algorithm is an extension of the Minimax algorithm to design preset equalizers for channels with known impulse responses. Both transversal and frequency-sampling equalizer structures are designed to produce a minimax approximation of a specified channel output waveform. Examples of these designs are compared as to the accuracy of the approximation, the resultant intersymbol interference (ISI), and the required transmitted energy. While the transversal designs are slightly more accurate, the frequency-sampling designs using six resonators have smaller ISI and energy values.

Houts, R. C.↗

Characteristics of corona impulses from insulated wires subjected to high ac voltages

Corona discharges arise due to ionization of air or gas subject to high electric fields. The free electrons and ions contained in these discharges interact with molecules of insulating materials, resulting in chemical changes and destroying the electrical insulating properties. The paper describes some results of measurements aimed at determining corona pulse waveforms, their repetition rate, and amplitude distribution during various randomly-sampled identical time periods of a 60-Hz high-voltage wave. Described are properties of positive and negative corona impulses generated from typical conductors at various test high voltages. A possible method for calculating the energies, densities, and electromagnetic interferences by making use of these results is suggested.

Doreswamy, C. V.↗

Circular-scan streak tube with solid-state readout

A circular-scan streak tube designed for use in a laser ranging system is described. Electrostatic focusing is used between the photocathode and a microchannel plate, and electrons from the microchannel plate are proximity focused onto an output phosphor screen. Electron beam deflection is achieved by driving two orthogonal sets of deflection plate assemblies in phase quadrature at a frequency of 200 MHz. The light intensity in the output beam trace is measured by using a circular Reticon array of 720 photodiodes, which is fiber-optically coupled to the output phosphor screen of the tube. Sample measurements of frequency-doubled Nd:YAG laser-pulse waveforms are given. Also the output beamwidth has been measured at the 200-MHz deflection frequency. The results suggest a limiting resolution of 33 psec for the circular-scan streak tube used for these tests.

Johnson, C. B.↗

Electromagnetic resonances of cylinders and aircraft model with resistive wires

The natural frequencies of the electromagnetic resonances of conducting bodies with attached wires were determined. The bodies included twp cylinders and an approximate scale model of the NASA F-106B aircraft. All were three feet in length. Time domain waveforms of B-dot and D-dot were obtained from a sampling oscilloscope, and Prony analysis was used to extract the natural frequencies. The first four natural frequencies of the cylinders (and wires) were determined, and a comparison with calculated results of other investigators shows reasonable agreement. Seven natural frequencies were determined for the F-106B model (with wires), and these were compared with results obtained by NASA in 1982 during direct lightning strikes to the aircraft. The agreement between the corresponding natural frequencies of the model and the aircraft is fairly good and is better than that obtained in the previous work using wires with less resistance. The frequencies lie between 6.5 MHz and 41 MHz, and all of the normalized damping rates are between 0.14 and 0.27.

Wood, G. W.↗

Electromagnetic resonances of cylinders and aircraft model with resistive wires

Laboratory experiments were done to determine the natural frequencies of the electromagnetic resonances of conducting bodies with attached wires. The bodies include two cylinders and an approximate scale model of the NASA F-106B aircraft. All are three feet in length. Time-domain waveforms of B-dot and D-dot were obtained from a sampling oscilloscope, and Prony analysis was used to extract the natural frequencies. This work is an extension of previous work, but smaller, more resistive wires have been used. The first four natural frequencies of the cylinders (and wires) were determined, and a comparison with calculated results of other investigators show reasonable agreement. Seven natural frequencies were determined for the F-106B model (wire wires), and these have been compared with results obtained by NASA in 1982 during direct lightning strikes to the aircraft. The agreement between the corresponding natural frequencies of the model and the aircraft is fairly good and is better than that obtained in the previous work using wires with less resistance. The frequencies lie between 6.5 MHz and 41 MHz, and all of the normalized damping rates are between 0.14 and 0.27.

Wood, G. W.↗

Ground signature extrapolation of three-dimensional near-field CFD predictions for several HSCT configurations

A CFD analysis of the near-field sonic boom environment of several low boom High Speed Civilian Transport (HSCT) concepts is presented. The CFD method utilizes a multi-block Euler marching code within the context of an innovative mesh topology that allows for the resolution of shock waves several body lengths from the aircraft. Three-dimensional pressure footprints at one body length below three-different low boom aircraft concepts are presented. Models of two concepts designed by NASA to cruise at Mach 2 and Mach 3 were built and tested in the wind tunnel. The third concept was designed by Boeing to cruise at Mach 1.7. Centerline and sideline samples of these footprints are then extrapolated to the ground using a linear waveform parameter method to estimate the ground signatures or sonic boom ground overpressure levels. The Mach 2 concept achieved its centerline design signature but indicated higher sideline booms due to the outboard wing crank of the configuration. Nacelles are also included on two of NASA's low boom concepts. Computations are carried out for both flow-through nacelles and nacelles with engine exhaust simulation. The flow-through nacelles with the assumption of zero spillage and zero inlet lip radius showed very little effect on the sonic boom signatures. On the other hand, it was shown that the engine exhaust plumes can have an effect on the levels of overpressure reaching the ground depending on the engine operating conditions. The results of this study indicate that engine integration into a low boom design should be given some attention.

Siclari, M. J.↗

Apparatus and Method for Measuring Strain in Bragg Gratings

An apparatus and method for measuring strain of gratings written into an optical fiber is disclosed. Optical radiation is transmitted over a plurality of contiguous predetermined wavelength ranges into a reference optical fiber network and an optical fiber network under test to produce a plurality of reference interference fringes and measurement interference fringes. respectively. The reference and measurement fringes are detected and sampled such that each sampled value of the reference and measurement fringes is associated with a corresponding sample number. The wavelength change of the reference optical fiber, for each sample number, due to the wavelength of the optical radiation is determined. Each determined wavelength change is matched with a corresponding sampled value of each measurement fringe. Each sampled measurement fringe of each wavelength sweep is transformed into a spatial domain waveform. The spatial domain waveforms are summed to form a summation spatial domain waveform that is used to determine location of each grating with respect to a reference reflector. A portion of each spatial domain waveform that corresponds to a particular grating is determined and transformed into a corresponding frequency spectrum representation. The strain on the grating at each wavelength of optical radiation is determined by determining the difference between the current wavelength and an earlier, zero-strain wavelength measurement.

Froggatt, Mark E.↗

Edge Triggered Apparatus and Method for Measuring Strain in Bragg Gratings

An apparatus and method for measuring strain of gratings written into an optical fiber. Optical radiation is transmitted over one or more contiguous predetermined wavelength ranges into a reference optical fiber network and an optical fiber network under test to produce a plurality of reference interference fringes and measurement interference fringes, respectively. The reference and measurement fringes are detected, and the reference fringes trigger the sampling of the measurement fringes. This results in the measurement fringes being sampled at 2(pi) increments of the reference fringes. Each sampled measurement fringe of each wavelength sweep is transformed into a spatial domain waveform. The spatial domain waveforms are summed to form a summation spatial domain waveform that is used to determine location of each grating with respect to a reference reflector. A portion of each spatial domain waveform that corresponds to a particular grating is determined and transformed into a corresponding frequency spectrum representation. The strain on the grating at each wavelength of optical radiation is determined by determining the difference between the current wavelength and an earlier, zero-strain wavelength measurement.

Froggatt, Mark E.↗

A study of possible sea state information in the sample and hold gate statistics for the GEOS-3 satellite altimeter

The statistical variations in the sample gate outputs of the GEOS-3 satellite altimeter were studied for possible sea state information. After examination of a large number of statistical characteristics of the altimeter waveforms, it was found that the best sea predictor for H-1/3 in the range of 0 to 3 meters was the 75th percentile of sample and hold gate number 11.

Wells, W. T.↗

Wallops waveform analysis of SEASAT-1 radar altimeter data

Fitting a six parameter model waveform to over ocean experimental data from the waveform samplers in the SEASAT-1 radar altimeter is described. The fitted parameters include a waveform risetime, skewness, and track point; from these can be obtained estimates of the ocean surface significant waveheight, the surface skewness, and a correction to the altimeter's on board altitude measurement, respectively. Among the difficulties encountered are waveform sampler gains differing from calibration mode data, and incorporating the actual SEASAT-1 sampled point target response in the fitted wave form. There are problems in using the spacecraft derived attitude angle estimates, and a different attitude estimator is developed. Points raised in this report have consequences for the SEASAT-1 radar altimeter's ocean surface measurements are for the design and calibration of radar altimeters in future oceanographic satellites.

Hayne, G. S.↗

Processing Waveform-Based NDE

A computer implemented process for simultaneously measuring the velocity of terahertz electromagnetic radiation in a dielectric material sample without prior knowledge of the thickness of the sample and for measuring the thickness of a material sample using terahertz electromagnetic radiation in a material sample without prior knowledge of the velocity of the terahertz electromagnetic radiation in the sample is disclosed and claimed. Utilizing interactive software the process evaluates, in a plurality of locations, the sample for microstructural variations and for thickness variations and maps the microstructural and thickness variations by location. A thin sheet of dielectric material may be used on top of the sample to create a dielectric mismatch. The approximate focal point of the radiation source (transceiver) is initially determined for good measurements.

Roth, Donald J↗

Gulf of Mexico satellite radar altimetry

The dynamic topography of the sea surface was measured. The radar altimeter measurements yield average ocean topographic data which are mapped. Seasonal deviations from a 3 year mean topography are presented. The altimeters are also instrumented with sample and hold gates which provide information about the shape and amplitude of the return waveform. Parameters including ocean surface wind speed and the significant wave height are determined. One hundred eighty six wind speed and significant wave height histograms are presented.

Parra, C. G.↗

Time-Domain Terahertz Computed Axial Tomography NDE System

NASA has identified the need for advanced non-destructive evaluation (NDE) methods to characterize aging and durability in aircraft materials to improve the safety of the nation's airline fleet. 3D THz tomography can play a major role in detection and characterization of flaws and degradation in aircraft materials, including Kevlar-based composites and Kevlar and Zylon fabric covers for soft-shell fan containment where aging and durability issues are critical. A prototype computed tomography (CT) time-domain (TD) THz imaging system has been used to generate 3D images of several test objects including a TUFI tile (a thermal protection system tile used on the Space Shuttle and possibly the Orion or similar capsules). This TUFI tile had simulated impact damage that was located and the depth of damage determined. The CT motion control gan try was designed and constructed, and then integrated with a T-Ray 4000 control unit and motion controller to create a complete CT TD-THz imaging system prototype. A data collection software script was developed that takes multiple z-axis slices in sequence and saves the data for batch processing. The data collection software was integrated with the ability to batch process the slice data with the CT TD-THz image reconstruction software. The time required to take a single CT slice was decreased from six minutes to approximately one minute by replacing the 320 ps, 100-Hz waveform acquisition system with an 80 ps, 1,000-Hz waveform acquisition system. The TD-THZ computed tomography system was built from pre-existing commercial off-the-shelf subsystems. A CT motion control gantry was constructed from COTS components that can handle larger samples. The motion control gantry allows inspection of sample sizes of up to approximately one cubic foot (.0.03 cubic meters). The system reduced to practice a CT-TDTHz system incorporating a COTS 80- ps/l-kHz waveform scanner. The incorporation of this scanner in the system allows acquisition of 3D slice data with better signal-to-noise using a COTS scanner rather than the gchirped h scanner. The system also reduced to practice a prototype for commercial CT systems for insulating materials where safety concerns cannot accommodate x-ray. A software script was written to automate the COTS software to collect and process TD-THz CT data.

Zimdars, David↗