Search NASA⌕ Search

SEARCH · Search NASA

Results for “Wire chambers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Nuclear Science Symposium, 30th, and Symposium on Nuclear Power Systems, 15th, San Francisco, CA, October 19-21, 1983, Proceedings

The range of disciplines covered includes physics instrumentation, data acquisition, FASTBUS, radiation detectors, scintillators, photomultipliers and optical detectors, subnanosecond 2-D imaging, medical and health instrumentation, reactor instrumentation, and space instrumentation. Cerenkov detectors, the prevention and rate capability of breakdown processes in wire chambers, and an interactive parallel processor for data analysis are studied. Attention is also given to bismuth germanate's role in gamma-ray spectroscopy, and the construction of a broadband universal sampling head is described. Gamma-ray imaging with a rotating hexagonal uniform redundant array, and broadband X-ray astronomical spectrometry are considered.

Nakamura, M.↗

The Fundamental Gain Limitation of High-Rate Gaseous Detectors and Optimum Designs for High-Rate Applications

We have performed a systematic study of the breakdown mechanism of high-rate detectors: MSGC, MGC, MICROMEGAS and GEM, recently chosen or considered as candidates for high-luminosity applications, together with newly elaborated designs such as high-rate wire chambers, thin gap parallel-plate chamber and super-high-rate RPC's. It was found for all these that the maximum breakdown-limited dramatically with incident flux and further decreases in the presence of alpha particles which are typical of the backgrounds in high-energy experiments. It was determined that the key parameter that limits a detector's performance is the effective current density in the avalanche, and that above a certain value breakdowns occur. At these limits the subsequent breakdowns take place by a mechanism which does not seem to have been previously reported in the literature. We present the results of this study together with a qualitative theory of this new type of breakdown and suggestions for optimizing high-rate detectors which we have verified experimentally.

Fonte, Paulo↗

Commissioning Trigger for the SpinQuest/E1039 Experiment

The SpinQuest experiment at Fermilab aims to measure the Sivers asymmetry for the light antiquarks in the nucleon using the Drell-Yan process. If the Sivers asymmetry is not zero, we will have found evidence for non-zero orbital angular momentum of light antiquarks. The commissioning of the SpinQuest experiment has two phases. First, we will trigger on cosmic ray muons to understand the performance of the SpinQuest detector which comprises hodoscopes, wire chambers, and proportional tubes. Second, we will use the 120 GeV Main Injector proton beam to test all the detectors more thoroughly and analyze the data to get prepared for physics running. This poster will present the structure of the commissioning trigger, the timing calibration, and the measured performance of the hodoscopes using cosmic rays.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam-Based Target Alignment for Mu2e

The Mu2e Experiment is a precision experiment at Fermi National Accelerator Laboratory, searching for charged lepton flavor violation (CLFV) in the conversion of a muon to an electron in the presence of an atomic nucleus. In order to achieve the expected single-event sensitivity of $3\times 10^{-17}$ , Mu2e will require an intense muon beam, generated via pion decay. These pions are the product of a proton beam striking a radiatively-cooled tungsten target. In order to maximize pion production and prevent target failure, the beam will have to be aligned with the target center to within 0.5 mm. The production target monitor (PTM) will ensure this alignment. The PTM consists of a series of proportional wire chambers (PWC’s) upstream and downstream of the production target. In this dissertation, I explain the requirements of this detector system and derive the decisions about which detector model to use and how they should be arranged from these requirements. After this, I describe my e xperience building the detectors and show an early use for them in the Mu2e proton beam. I also performed a study of the sensitivity and time resolution of this model of PWC and its electronics, and give the results here. I then describe a series of simulation campaigns which shed light on the interactions between the beam and the target, and how these interactions manifest on the downstream detectors. Finally, I give the target scanning procedure to be used to align the beam and target during experiment start up.

43 PARTICLE ACCELERATORS↗

Comparison of 'integrating' and 'tracking' modes of operation in the Qweak experiment

The Qweak experiment the first direct measurement of the proton's weak charge $Q_W^p$, has recently completed data collection at Jefferson Lab. Polarized, 1.165~GeV electrons were scattered from protons and focused onto an array of large (2\,m$\times$0.18\,m) fused-silica Cherenkov detectors. We have proposed to measure the parity-violating asymmetry associated with $Q_W^p$ to a precision of 5~ppb. To meet this statistical requirement, the bulk of the data were collected using 'integrating' electronics (with typical event rates $\sim$800\,MHz per detector). However, the observed asymmetry also depends on the distribution of momentum transfer $Q^2$ accepted by the experiment. Measurements of $Q^2$ were made by inserting wire chamber detectors --- but only with the beam current reduced by three to six orders of magnitude. For these ``tracking'' measurements, the main detectors were connected to electronics able to resolve single events. As a bridge between integrating and tracking modes, a small (1\,cm$\times$1\,cm) Cherenkov detector on a motion stage had freedom to scan over one of the large Cherenkov detectors; the small size permitted use of the same electronics at all beam currents. In this talk I will discuss the consistency of results from these various modes of operation.

Mahurin, Robert↗

Neutrino event selection in the MicroBooNE liquid argon time projection chamber using Wire-Cell 3D imaging, clustering, and charge-light matching

An accurate and efficient event reconstruction is required to realize the full scientific capability of liquid argon time projection chambers (LArTPCs). The current and future neutrino experiments that rely on massive LArTPCs create a need for new ideas and reconstruction approaches. Wire-Cell, proposed in recent years, is a novel tomographic event reconstruction method for LArTPCs. The Wire-Cell 3D imaging approach capitalizes on charge, sparsity, time, and geometry information to reconstruct a topology-agnostic 3D image of the ionization electrons prior to pattern recognition. A second novel method, the many-to-many charge-light matching, then pairs the TPC charge activity to the detected scintillation light signal, thus enabling a powerful rejection of cosmic-ray muons in the MicroBooNE detector. A robust processing of the scintillation light signal and an appropriate clustering of the reconstructed 3D image are fundamental to this technique. In this paper, we describe the principles and algorithms of these techniques and their successful application in the MicroBooNE experiment. A quantitative evaluation of the performance of these techniques is presented. Using these techniques, a 95% efficient pre-selection of neutrino charged-current events is achieved with a 30-fold reduction of non-beam-coincident cosmic-ray muons, and about 80% of the selected neutrino charged-current events are reconstructed with at least 70% completeness and 80% purity.

3D imaging↗

Chamber For Microgravity Combustion Experiments

Versatile container for microgravity combustion experiments used in space, in airplane, or in drop tower. Hub top with gas ports encloses chamber. Instrumentation wire fed into chamber through base. Combustion initiated by wire fuse. Oxygen supplied to support combustion, argon to quench it. Container withstands repeated prolonged impacts.

Steinberg, Theodore A.↗

Apparatus for Measuring Total Emissivity of Small, Low-Emissivity Samples

An apparatus was developed for measuring total emissivity of small, lightweight, low-emissivity samples at low temperatures. The entire apparatus fits inside a small laboratory cryostat. Sample installation and removal are relatively quick, allowing for faster testing. The small chamber surrounding the sample is lined with black-painted aluminum honeycomb, which simplifies data analysis. This results in the sample viewing a very high-emissivity surface on all sides, an effect which would normally require a much larger chamber volume. The sample and chamber temperatures are individually controlled using off-the-shelf PID (proportional integral derivative) controllers, allowing flexibility in the test conditions. The chamber can be controlled at a higher temperature than the sample, allowing a direct absorptivity measurement. The lightweight sample is suspended by its heater and thermometer leads from an isothermal bar external to the chamber. The wires run out of the chamber through small holes in its corners, and the wires do not contact the chamber itself. During a steady-state measurement, the thermometer and bar are individually controlled at the same temperature, so there is zero heat flow through the wires. Thus, all of sample-temperature-control heater power is radiated to the chamber. Double-aluminized Kapton (DAK) emissivity was studied down to 10 K, which was about 25 K colder than any previously reported measurements. This verified a minimum in the emissivity at about 35 K and a rise as the temperature dropped to lower values.

Tuttle, James↗

Cathode Strip Chambers in ATLAS: Installation, Commissioning and in situ Performance

The Muon Spectrometer of the ATLAS detector at the LHC is designed to provide high quality stand-alone muon identification, momentum measurement and trigger capabilities with high pseudorapidity coverage. Precision tracking at the inner-most station in the high pseudorapidity regions, 2.3 < |eta| < 2.7, is performed by 16 four-layered Cathode Strip Chambers on each end-cap. These are multi-wire proportional chambers with segmented cathodes providing excellent spatial resolution and high counting rate capability. The second cathode of each layer is coarsely segmented, providing the transverse coordinate. The detector level performance of the system is presented. The installation and commissioning effort for the Cathode Strip Chambers is described. Finally, the in situ performance is briefly discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for the Cryptoexotic Member N{sub 10} of the Baryon Antidecuplet 1/2+ in the Reactions {pi}{sup -}p{yields}{pi}{sup -}p and {pi}{sup -}p{yields}K{lambda}

The main goal of this proposal is the search for a narrow cryptoexotic nucleon resonance by scanning of the {pi}{sup -}p system invariant mass in the region (1610-1770) MeV with the detection of {pi}{sup -}p and K{lambda} decays. The scan is supposed to be done by the variation of the incident {pi}{sup -} momentum and its measurement with the accuracy of up to {+-}0.1%(better than 1 MeV in terms of the invariant mass in the whole energy range) with a set of proportional chambers located in first focus of the magneto-optical channel. High sensitivity of the method to the resonance under search is shown. The secondary particles scattered from a liquid hydrogen target are detected by sets of the wire drift chambers equipped with modern electronics.Now it is achieved the pion beam momentum resolution better than 0.1% at P{sub {pi}} = 1.5 GeV/c. The wire drift chambers are in preparation. The liquid hydrogen target is tested. The first experimental accelerator run can be at the end of 2008 year.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optical and electrical investigation of a cylindrical diffuse-discharge chamber

More and more attention has been attached to atmospheric-pressure air diffuse plasma due to its enormous potential applications. In this paper, we designed a large-scale, cylindrical diffuse-plasma chamber using wire electrodes and a repetitive nanosecond pulse generator. The plasma chamber can be completely exposed in the open air without any barrier dielectric, and the length of cylindrical plasma chamber was extensible. Using optical and electrical measurements, we investigated the effects of electrode distance, electrode length, pulse repetition frequency, and electrode angle on the uniformity of discharge space. Four discharge regions were distinguished based on different spectral characteristics. Additionally, it was found that the discharge uniformity was improved as the electrode distance decreases, but remained almost constant with the variations of electrode length and pulse repetition frequency. Both of the plasma uniformity and the power density increased significantly as the electrode angle reduced.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Construction and assembly of the wire planes for the MicroBooNE Time Projection Chamber

In this paper we describe how the readout planes for the MicroBooNE Time Projection Chamber were constructed, assembled and installed. We present the individual wire preparation using semi-automatic winding machines and the assembly of wire carrier boards. The details of the wire installation on the detector frame and the tensioning of the wires are given. A strict quality assurance plan ensured the integrity of the readout planes. The different tests performed at all stages of construction and installation provided crucial information to achieve the successful realization of the MicroBooNE wire planes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-66: A Prototype for Couch Based Real-Time Dosimetry in External Beam Radiotherapy

Purpose: The main purpose of this study is to design a prototype for couch-based based real time dosimetry system in external beam radiotherapy Methods: A prototype of 100 ionization chambers was designed on a printed circuit board by etching the copper layer and each ionization chamber was wired to a 50 pin connector. The signals from the two 50 pin connectors collected from the ionization chambers were then transferred to a PXI module from National Instruments. The PXI module houses a current amplifier that amplifies the charge collected from the ionization chamber. The amplified signal is then sent to a digital multimeter module for converting the analog signal to digital signal. A software was designed in labview to read and display the signals obtained from the PXI module. A couch attachment frame was designed to house the 100 ionization chamber module. The frame was fixed underneath the treatment couch for measuring the dose during treatment. Resutls: The ionization chamber based prototype dosimetry was tested for simple radiotherapy treatment fields and found to be a useful device for measuring real time dosimetry at the treatment couch plane. This information could be used to assess the delivered dose to a patient during radiotherapy. It could be used as an invivo dosimeter during radiotherapy. Conclusion: In this study, a prototype for couch based real time dosimetry system was designed and tested. The prototype forms a basis for the development of large scale couch based real time dosimetry system that could be used to perform morning QA prior to treatment, assess real time doses delivered to patient and as a device to monitor the output of the treatment beam. Peter MacCallum Cancer Foundation.

60 APPLIED LIFE SCIENCES↗

1985 Nuclear Science Symposium, 32nd, and 1985 Symposium on Nuclear Power Systems, 17th, San Francisco, CA, October 23-25, 1985, Proceedings

The present conference ranges over topics in high energy physics instrumentation, detectors, nuclear medical applications, health physics and environmental monitoring, reactor instrumentation, nuclear spacecraft instrumentation, the 'Fastbus' data acquisition system, circuits and systems for nuclear research facilities, and the development status of nuclear power systems. Specific attention is given to CCD high precision detectors, a drift chamber preamplifier, a Cerenkov ring imaging detector, novel scintillation glasses and scintillating fibers, a modular multidrift vertex detector, radial wire drift chambers, liquid argon polarimeters, a multianode photomultiplier, the reliability of planar silicon detectors, the design and manufacture of wedge and strip anodes, ultrafast triode photodetectors, photomultiplier tubes, a barium fluoride plastic scintillator, a fine grained neutron hodoscope, the stability of low leakage silicon photodiodes for crystal calorimeters, and X-ray proportional counters. Also considered are positron emission tomography, single photon emission computed tomography, nuclear magnetic resonance imaging, Geiger-Muller detectors, nuclear plant safeguards, a 32-bit Fastbus computer, an advanced light water reactor, and nuclear plant maintenance.

Source record↗

Resolution of the ATLAS muon spectrometer monitored drift tubes in LHC Run 2

The momentum measurement capability of the ATLAS muon spectrometer relies fundamentally on the intrinsic single-hit spatial resolution of the monitored drift tube precision tracking chambers. Optimal resolution is achieved with a dedicated calibration program that addresses the specific operating conditions of the 354 000 high-pressure drift tubes in the spectrometer. The calibrations consist of a set of timing offsets and drift time to drift distance transfer relations, and result in chamber resolution functions. This paper describes novel algorithms to obtain precision calibrations from data collected by ATLAS in LHC Run 2 and from a gas monitoring chamber, deployed in a dedicated gas facility. The algorithm output consists of a pair of correction constants per chamber which are applied to baseline calibrations, and determined to be valid for the entire ATLAS Run 2. The final single-hit spatial resolution, averaged over 1172 monitored drift tube chambers, is $81.7 \pm 2.2 \mu$m.

47 OTHER INSTRUMENTATION↗

Performance of a Drift Chamber Candidate for a Cosmic Muon Tomography System

In the last decade, many groups around the world have been exploring different ways to probe transport containers which may contain illicit Special Nuclear Materials such as uranium. The muon tomography technique has been proposed as a cost effective system with an acceptable accuracy. A group of Canadian institutions (see above), funded by Defence Research and Development Canada, is testing different technologies to track the cosmic muons. One candidate is the single wire Drift Chamber. With the capability of a 2D impact position measurement, two detectors will be placed above and two below the object to be probed. In order to achieve a good 3D image quality of the cargo content, a good angular resolution is required. The simulation showed that 1mrad was required implying the spatial resolution of the trackers must be in the range of 1 to 2 mm for 1 m separation. A tracking system using three prototypes has been built and tested. The spatial resolution obtained is 1.7 mm perpendicular to the wire and 3 mm along the wire.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DEVELOPMENT OF A LIGHT-WEIGHT REGENERATIVELY COOLED THRUST CHAMBER WITH BRAZED RIBS AND BRAZED OUTER WIRE TRAP

Design and fabrication procedures are discussed of a brazed-ribtype thrust chamber fabricated from stainless steel or inconel for a Sooo-lb thrust 20: 1 expansion-area-ratio regeneratively cooled liquidpropellant rocket engine which is designated as the JPL 6K Engine and operates at a chamber pressure of 150 psia. Hydrazine is used as the fuel and regenerative coolant and nitrogen tetroxide as the oxidizer. The nozzle-throat diameter is 5.42 in. The thrust chamber consists of a sheet-metal gas-side liner with longitudinal ribs spotwelded and brazed to the outer surface. Wire is wrapped over the ribs circumferentially, spot-welded to the ribs, and brazed. The liner, ribs, and wire form the coolant-passage walls. There are three basic advantages to this type of thrust chamber: light weight, ease of fabrication, and comparatively low cost. The total dry weight of a thrust chamber of this type and size made of 347 stainless steel is 46.2 lb, and the wet weight is 56.3 Ib. A total of 87 static engine tests were made on 19 of 23 thrust chambers fabricated by this technique. Four of the chambers tested had an expansion-area ratio of 20:1, and 15, which were shorter but had the same throat diameter, had an expansion-area ratio of 3.5:l. Accumulated test time was 1926 sec, including 558 sec regenerative cooling with hydrazine and 1368 sec cooling with water. One 20:l thrust chamber was subjected to 16 separate engine tests, with an accumulated test time of 399 sec, and was still in very good operating condition after the tests were completed. With water flowing through the coolant passages at 10 lb/sec, the measured nominal pressure drop between coolant manifolds of a 20:l thrust chamber wrapped with flat wire was 17.2 psi.

Thrust Chamber↗

Partition Thickness Considerations for Additively Manufactured Acoustic Liners

Three types of uniform-depth liners are evaluated to explore the effects of partition thickness on the surface impedance achieved with additively manufactured liners. A transmission line code is used to predict the effects of sound transmission through empty chambers and wire mesh facesheets, and is combined with the Motsinger and Kraft model to account for sound transmission through perforated facesheets. The inclusion of partitions causes a blockage effect, i.e., a portion of the surface is ‘blocked’ (nonactive surface). For liners with no facesheet, these blockage effects are incorporated simply by accounting for the change in cross sectional area between the individual chamber and the unit cell that includes half of a partition thickness around the perimeter of this chamber. Comparison of impedances predicted in this manner with data acquired in the NASA Langley Normal Incidence Tube (NIT) confirms the efficacy of this modeling approach. Two approaches are considered to account for the inclusion of a wiremesh or perforated plate facesheet on these same cores. The first accounts for the effects of partition thickness before including the transfer impedance across the facesheet, while the second reverses these steps. A comparison of data acquired in the NASA NIT with modeled impedances suggests the first approach is best when the facesheet is a wire mesh, but the second approach is preferred when a perforated plate facesheet is used. It is hypothesized that this is due to the fact that a lumped element model is used to compute the transfer impedance across a wire mesh, while the corresponding transfer impedance across a perforated sheet explicitly incorporates the efffects of the liner core. However, comparisons of data acquired in the NASA Langley Grazing Flow Impedance Tube with modeled impedances seem slightly better when the first approach is employed with a perforated plate facesheet. Thus, the effects of partition thickness on liners with perforated sheets subjected to grazing incidence sound require further review

acoustic↗