Search NASA⌕ Search

SEARCH · Search NASA

Results for “Wolter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Analysis of NOAA-MSFC GOES X-ray telescope

The general telescope system was assumed to be a paraboloid-hyperboloid in a Wolter Type 1 configuration. The equations which specify the telescope parameters and the resolution as a function of the collecting area are discussed as well as the spot size and point response function for off-axis rays. The measured resolution of the Goddard ATM X-ray telescope (S-056) is compared to the rms blur circle radius and the full width half maximum of the line spread function. An empirical scaling formula, Eq. 26, which transforms the rms blur circle radius into a more accurate measure of resolution, is introduced. The geometrical imaging properties of the proposed NOAA-MSFC GOES X-ray telescope are considered. Conclusions and alternate mirror designs are included.

Shealy, D. L.↗

A solar extreme ultraviolet telescope and spectrograph for space shuttle. Volume 1: Investigation and technical plan

A scientific investigation of heating and mass transport in the solar corona that is currently planned for a future Shuttle/Spacelab flight is outlined. The instrument to be used is a near-normal incidence grating spectrograph fed by a grazing incidence Wolter Type 2 telescope. A toroidal grating design provides stigmatic images of the corona up to 8 arc min in extent over the spectral region from 225 A to 370 A. Spatial resolution of at least 2 arc sec and spectral resolution of 0.050 A is achievable throughout the central 4 arc min field or view. Primary scientific data are recorded on Schumann-type film. An H-alpha slit jaw monitor and zero order extreme ultraviolet monitor are also planned to support instrument operation.

Neupert, W. M.↗

Space optics: Imaging X-ray optics workshop; Proceedings of the Seminar, Huntsville, Ala., May 22-24, 1979

The papers in this volume are broadly based and represent a comprehensive summary of past achievements, new designs, techniques and future plans in space optics. The design, construction, testing and use of grazing incidence optics have played an integral role in the advance of X-ray astronomy. Topics of interest include a cosmic X-ray telescope for ARIES rocket observations, quest for ultrahigh resolution in X-ray optics, optical coating techniques for Wolter-type substrates, astronomical applications of grazing incidence telescopes with polynomial surfaces, and a paraboloidal X-ray telescope mirror for solar coronal spectroscopy.

Weisskopf, M.↗

Experiments with diamond-turned metal X-ray mirrors

It is noted that the primary advantages of diamond turning technology for the fabrication of X-ray telescope mirrors is in the smoothness of the finished surface and the control of the position of the cutter afforded by the precision slides and computer-assisted positioners which form the surface. The paper summarizes the Caltech work in attempting to make Wolter Type I telescope mirrors using the diamond turning facilities at the Oak Ridge Y-12 laboratory. Attention is given to such factors as the use of aluminum with copper plating and electroless nickel coating. It is found that although the diamond turning capability of the Y-12 lab is capable of making good X-ray mirror contours, there are problems in the process which have limited the accuracy achieved by this technique.

Garmire, G. P.↗

Cosmic X-ray telescope for ARIES rocket observations

A rocket-borne Wolter Type I X-ray telescope having a focal length of 2.3m, an entrance aperture of 66cm and a geometrical area of 380cm2 is nearing completion. The telescope mirrors are formed by diamond turning their figures into forged aluminum substrates of 5083 alloy. These diamond-turned substrates are subsequently plated with a thin coating of electroless nickel and polished to obtain the final X-ray reflecting surfaces. Details of the rocket payload, the X-ray telescope, its calculated response and the experience gained in selecting the mirror substrate alloy are discussed and the current status of the telescope is reviewed.

Catura, R. C.↗

Design of stigmatic grazing incidence telescopes with non-parabolic primaries

A two-mirror grazing-incidence telescope having a non-parabolic primary, and designed to be free of spherical aberration has been investigated. A method for determining the second surface equation is described, when the surface equation for one mirror is given. Application to grazing incidence systems such as used in X-ray and planed for EUV astronomy is discussed. Of special interest is the design of a secondary mirror when the hyperboloid of a conventional Wolter type I system is taken as the primary.

Winkler, C. E.↗

Astronomical applications of grazing incidence telescopes with polynomial surfaces

The report has examined the claim that grazing incidence telescopes having surfaces described by generalized equations have image characteristics superior to those of the paraboloid-hyperboloid and Wolter-Schwarzschild configurations. With emphasis on specific applications in solar and cosmic X-ray/EUV astronomy, raytracing has shown that in many cases there is no advantage in the polynomial design, and in those cases where advantages are theoretically to be expected, the advantages are outweighed by practical considerations.

Cash, W.↗

Advanced X-ray Astrophysics Facility /AXAF/

The Advanced X-ray Astrophysics Facility (AXAF) will be a national observatory designed for the observation of galactic and extragalactic X-ray sources. The observatory is currently planned to be launched by the Space Shuttle, maintainable in orbit and retrievable, if necessary, during its 10 to 15 years of operation. The heart of the AXAF is an X-ray telescope made up of six Wolter type 1 mirrors, with the diameter of the outermost mirror 1.2 m. The focal length will be 10 m, and the AXAF will allow for interchanging and (in-orbit) replacing of focal plane instruments. The optics are being designed to provide a spatial resolution of 0.5 arc second over a several arc-minute field and somewhat reduced angular resolution over the entire 1-degree field of view. The energy bandwidth will be 0.1 to 8 keV. These design goals place severe requirements on the materials, tolerances, construction, and alignment of the telescope. These will be discussed and compared to previous work in this area.

Weisskopf, M. C.↗

Fabrication of X-ray telescopes for sounding rocket flights

Two X-ray telescopes and two detector systems were fabricated, and one of the telescopes (15 in. diameter, Wolter type I telescope) was flown on two sounding rocket flights. The telescopes were fabricated using the diamond point technique which provided the accurate figure of the mirrors to about a focal plane blur of 0.5 arc minutes. The 15 in. telescope mirrors were polished using standard polishing techniques to remove tooling marks from the diamond turning, then chemically polished to bring the X-ray reflectivity up to nearly the theoretical values. The optical image formed by the 15 in. telescope was found to produce a blur of about 40 arc seconds for a parallel beam of incoming laser light. The first flight of the telescope produced an X-ray image of Capella which indicated that the X-ray image was blurred to the extent of about 2 arc minutes. This additional image degradation was due to a slight error in focusing the X-ray image onto the detector.

Source record↗

The application of soft X-ray imaging techniques to auroral research

The feasibility of building and operating a grazing incidence X-ray telescope for auroral zone studies from the Polar Plasma Laboratory (PPL) is discussed. A detailed structural analysis of the preferred design, an array of seven nested Wolter mirrors, is presented. An engineering evaluation of the requirements for the instrumental configuration, power, weight and telemetry is included. The problems of radiation hardening and thermal control are discussed. The resulting strawman instrument is presented.

Source record↗

A wide-field soft X-ray camera

A wide-field soft X-ray camera (WFSXC) sensitive in the 50 to 250 eV band is described. The camera features Wolter-Schwarzschild optics with an 8 degree field of view and 300 cu cu collecting area. The focal plane instrument is a microchannel plate detector. Broad-band energy discrimination is provided by thin-film filters mounted immediately in front of the focal plane. The WFSXC is capable of detecting sources with intensities greater than 5 percent of HZ 43 during typical sounding rocket exposures, and it would approach the same sensitivity range as EUVE during a typical exposure from the Shuttle.

Petre, R.↗

Extended range X-ray telescope: X-ray microscope design

A glancing incidence X-ray microscope using a confocal hyperboloid ellipsoid mirror was designed to couple optically a Wolter 1 telescope to a CCD focal plane detector. Both the RMS spot size and the point spread function calculations were used to evaluate the resolution, defocusing, and vignetting effects of the system for microscope focal lengths of 1, 1.5, and 2 meters and for magnifications varying from 2 to 10x. For the specific application with the S-056 telescope, a 2 meter, 8x microscope with a fabrication ratio of the microscope mirror length to the inner diameter at hyperboloid ellipsoid intersection of 2.5 was designed to be used with a thinned, back illuminated CCD detector array with 320 by 512, 30 micron pixels.

Shealy, D. L.↗

Conceptual support design of the high resolution mirror assembly for the Advanced X-ray Astrophysics Facility (AXAF)

The performance goals of the Advanced X-ray Astrophysics Facility (AXAF) require that the Wolter I optics support system be insensitive to temperature fluctuations and the effects of gravity during ground testing. Previous work has shown that acceptable concepts are achievable but require much attention to design details. This paper discusses a new support system wherein each optic is held by a single circumfererential ring near its center of mass rather than a multipoint support as previously analyzed. The thermal sensitivity of this system is considerably lower than any concept yet studied. This advanced support concept allows the use of a wider variety of mateials and simple design details. Structural analysis utilizing the finite element method and optical ray-trace analysis are used to predict the system performance.

Cohen, L. M.↗

Theoretical design and analysis of the layered synthetic microstructure optic for the dual path X-ray telescope

A ray tracing analysis was performed for several configurations for the inner channel of the dual path X-ray telescope, which is proposed to use the second mirror of the Stanford/MSFC Wolter-Schwarzchild telescope and a normal incident layered synthetic microstructure (LSM) mirror to form a secondary image near the front of the telescope. The LSM mirror shapes considered were spherical, ellipsoid, hyperboloid, and constant optical path length (OPL) aspheric. Only the constant OPL case gave good axial resolution. All cases had poor off axis resolution as judged by the RMS blur circle radius.

Shealy, D. L.↗

The Extended Range X-Ray Telescope center director's discretionary fund report

An Extended Range X-Ray Telescope (ERXRT) of high sensitivity and spatial resolution capable of functioning over a broad region of the X-ray/XUV portion of the spectrum has been designed and analyzed. This system has been configured around the glancing-incidence Wolter Type I X-ray mirror system which was flown on the Skylab Apollo Telescope Mount as ATM Experiment S-056. Enhanced sensitivity over a vastly broader spectral range can be realized by the utilization of a thinned, back-illuminated, buried-channel Charge Coupled Device (CCD) as the X-ray/XUV detector rather than photographic film. However, to maintain the high spatial resolution inherent in the X-ray optics when a CCD of 30 micron pixel size is used, it is necessary to increase the telescope plate scale. This can be accomplished by use of a glancing-incidence X-ray microscope to enlarge and re-focus the primary image onto the focal surface of the CCD.

Hoover, R. B.↗

Multispectral glancing incidence X-ray telescope

A multispectural glancing incidence X-ray telescope is illustrated capable of broadband, high-resolution imaging of solar and stellar X-ray and extreme ultraviolet radiation sources which includes a primary optical system preferably of the Wolter I type having a primary mirror system. The primary optical system further includes an optical axis having a primary focus at which the incoming radiation is focused by the primary mirrors. A plurality of ellipsoidal mirrors are carried at an inclination to the optical axis behind the primary focus. A rotating carrier is provided on which the ellipsoidal mirrors are carried so that a desired one of the ellipsoidal mirrors may be selectively positioned in front of the incoming radiation beam. In the preferred embodiment, each of the ellipsoidal mirrors has an identical concave surface carrying a layered synthetic microstructure coating tailored to reflect a desired wavelength of 1.5A or longer. Each of the identifical ellipsoidal mirrors has a second focus at which a detector is carried. Thus the different wavelength image is focused upon the detector irregardless of which mirror is positioned in front of the radiation beam.

Hoover, R. B.↗

Electroform replication of grazing incidence X-ray optics

Work to produce mirrors via electroform replication is reported. Work on small (6 cm by 9 cm) cylindrical pieces and on 40 cm long by 12 cm wide Wolter shaped mirrors is summarized. It is shown that electroforming is a viable technique for producing relatively inexpensive grazing incidence X-ray optics, as long as modest resolution (1 min of arc) and size (12 cm diameter by 40 cm long) are specified.

Ulmer, M. P.↗

Near anastigmatic grazing incidence telescope

A performance capability assessment is presently conducted for short versus long grazing incidence telescope designs, in view of the observation that the field curvature and astigmatism that are the primary residual aberrations of a Wolter-type incidence telescope can be substantially reduced through mirror length reduction. A major advantage of the short element telescope is that, if sufficiently short, both the paraboloid and hyperboloid surfaces may be fabricated as a single piece; this significantly facilitates the task of alignment.

Korsch, D.↗