Search NASA⌕ Search

SEARCH · Search NASA

Results for “X radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Intermolecular correlations of liquid and glassy CS 2 studied by synchrotron radiation x-ray diffraction

How is the orientation of molecular liquids ordered on cooling? What are the basic structures of molecular glasses, e.g., close to the crystalline structure or some special structures such as icosahedral cluster? These are long-standing questions in liquid and glass physics. Here, we have constructed a novel cryostat to prepare simple molecular glasses by vapor deposition and performed in situ synchrotron radiation x-ray diffraction experiments. The glassy state of a simple molecule CS 2 , which cannot be vitrified by normal liquid quenching, was successfully prepared with this instrument, and its diffraction data were collected in a wide Q-range of 0.16–25.7 Å -1 with a high-energy diffractometer at BL04B2, SPring-8. The diffraction data of liquid CS 2 were also recorded in a wide temperature range of 160–300 K. These diffraction data were analyzed with molecular dynamics simulations and reverse Monte Carlo modelings to investigate orientational correlation. From the obtained 3D structure models, the orientational correlation between neighboring CS 2 molecules was investigated quantitatively as a function of temperature. At room temperature, the parallel and T-shaped arrangements are preferred for the nearest neighbor correlation. On cooling, these arrangements are developed gradually, and its rate became prominent below the melting temperature (162 K). In the glassy state, the slipped-parallel arrangement is dominant as well as the T-shaped arrangement. Both arrangements appear in the CS 2 crystal, indicating that the structure of glassy CS 2 is close to that of crystalline CS 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

(Cd,Mg)Te crystals for picosecond-response optical-to-x-ray radiation detectors

We demonstrate a photodetector sensitive to both optical and x-ray picosecond pulses based on our in-house grown cadmium magnesium telluride (Cd,Mg)Te single crystal. Specifically, we developed In-doped Cd0.96Mg0.04Te material and discuss its femtosecond optical photoresponse, as well as the detector performance, such as <100-pA dark current and up to 0.22-mA/W responsivity for 780-nm wavelength optical radiation. The detector exposed to Ti fluorescence (K alpha) x-ray pulses at 4.5 keV, generated by a free-electron laser beam with the central energy of 9.8 keV and <100 fs pulse width, exhibited readout-electronics-limited 200-ps full-width-at-half-maximum photoresponse, demonstrating that it is suitable for coarse timing in free-electron laser x-ray/optical femtosecond pump–probe spectroscopy applications.

Instruments & Instrumentation↗

The Hyper-X Antenna Radiation Pattern Tests and Radio Frequency System Redesign

Testing was performed to determine the antenna radiation pattern measurements of the Hyper-X, X-43 ship 2 aircraft. One test was conducted at the Air Force Flight Test Center (AFFTC) Benefield Anechoic Facility (BAF) on January 24-January 27, 2000. A second test was done at MicroCraft in Tullahoma Tennessee by the Naval Air Weapons Center (NAWC) China Lake, California on September 8, 2001. The overall test objective was to gather qualitative antenna radiation pattern data from installed antennas on the HXRV. This objective was accomplished by collecting antenna radiation patterns at selected elevations of the HXRV. The test data was used to identify areas of RF coverage and assist in positioning the P-3 aircraft for best RF reception. The antenna pattern data presented nulls and possible low RF reception areas around the aircraft. This led to a redesign of the RF system. The redesigned system provided redundancy in case a telemetry transmitter should fail. The redesign provided more complete RF coverage within the antenna's capabilities. A second look at the flight path and necessary data collection led to a change in the beacon transponder system.

Hodge, Mark W.↗

CsPbBr3 perovskite single crystals for X- and -radiation detectors

Methods were developed for the synthesis and growth of halide lead perovskites CsPbBr3, which can be used as detectors of optical, X-ray, and -radiation. The growth of single crystals was carried out by the Bridgman method in quartz ampoules using zone-refined starting material. The electro-physical properties of the inorganic perovskite lead cesium tribromide CsPbBr3 were studied. Two types of structures with Cr/CsPbBr3/Ni rectifying and Ni/CsPbBr3/Ni ohmic contacts were fabricated. The resistivity of (  7×109 Ohmcm), and the activation energy of the dark conductivity (E  0.8 eV) were determined. From the measurements of the optical transmission spectra, the CsPbBr3 energy gap at 300 K was found to be Еg = 2.27 eV. The temperature dependence of the forbidden gap (Eg(T) = 2.4 - 4*10-4 T, eV) was also determined. A significant increase in photosensitivity for the Cr/CsPbBr3/Ni structure was observed at elevated temperatures. The Cr/CsPbBr3/Ni structures were shown to be sensitive to -radiation. The FWHM of the energy resolution for 241Am source was measured to be 15.8 keV.

Sklyarchuk, V.↗

Direct comparison of gamma, electron beam and X-ray radiation effects on the polymers of a pulsed lavage device

Gamma radiation used for sterilization of medical devices is challenged by cobalt-60 supply and commercial capacity. To maintain a robust radiation sterilization marketplace for the rapidly growing single-use medical device industry, investigation of potential alternatives to gamma technology, such as electron beam (e-beam) and X-ray technology, is critical. In this work, we directly compare the effects of radiation source and absorbed dose level on the polymeric materials and function of a commercial pulsed lavage device used for wound care. Product functionality, polymer mechanical, and polymer optical properties were evaluated using standard methods and input from the device manufacturer. Test results show that functionality of the product was not inhibited by radiation although the battery in the device exposed to X-ray exhibited greater voltage loss compared to batteries in products exposed to gamma or e-beam. Statistically significant differences between gamma and e-beam exposure and between gamma and X-ray exposure were also observed for product appearance in terms of yellowness index of several of the polymers considered. Overall, the results of this study support the viability of e-beam and X-ray radiation technologies as alternatives to cobalt-60 gamma technology for sterilization of the single-use pulsed lavage medical device investigated.

Electron beam↗

Advances in solar and cosmic X-ray astronomy - A survey of experimental techniques and observational results.

The current status of X-ray astronomy is surveyed by reviewing observational results and theoretical conclusions gained within the past two years in areas dealing with the quiet-sun, slowly-varying, and burst components of solar X-radiation and with the features of cosmic X-ray sources. Thermal and nonthermal processes responsible for a wide variety of X-ray emission mechanisms in nature are explained, and characteristics of X radiation from specific solar structures are described. Attention is given to the effects of interstellar and intergalactic matter on cosmic X-rays; the properties of galactic and extragalactic X-ray sources; and the specifications of such instruments as gas-filled ionization detectors, proportional counters, Geiger counters, scintillation detectors, photoelectric detectors, polarimeters, collimators, spectrometers, and imaging systems.

Hoover, R. B.↗

Synchrotron Radiation from Outer Space and the Chandra X-Ray Observatory

The universe provides numerous extremely interesting astrophysical sources of synchrotron X radiation. The Chandra X-ray Observatory and other X-ray missions provide powerful probes of these and other cosmic X-ray sources. Chandra is the X-ray component of NASA's Great Observatory Program which also includes the Hubble Space telescope, the Spitzer Infrared Telescope Facility, and the now defunct Compton Gamma-Ray Observatory. The Chandra X-Ray Observatory provides the best angular resolution (sub-arcsecond) of any previous, current, or planned (for the foreseeable near future) space-based X-ray instrumentation. We present here a brief overview of the technical capability of this X-Ray observatory and some of the remarkable discoveries involving cosmic synchrotron sources.

Weisskopf, M. C.↗

Interaction of metagalactic X-UV radiation with galactic hydrogen

Calculations show that the existence of a metagalactic X-UV flux of the intensity required to explain the high-latitude soft X-ray observations, plus a reasonable extrapolation toward lower energies, is consistent with the existence of neutral hydrogen in galaxies. Shielding by H II slabs can be effective both in the solar neighborhood and in the peripheries of galaxies out to a radius of 30 to 40 kpc. At earlier cosmological epochs shielding is less efficient. The soft X-ray spectrum as observed by Yentis et al. (1972) is difficult to reconcile with a purely extragalactic origin for the flux. A local source of ionization also may be necessary to explain the pulsar dispersion data.

Hill, J. K.↗

Inhaled ozone as a mutagen. II - Effect on the frequency of chromosome aberrations observed in irradiated Chinese hamsters.

Exposure-adjusted break frequencies for chromosome aberrations produced in Chinese hamster circulating blood lymphocytes were the quantitative indicator of damage from 5 hrs of exposure to X-radiation and/or to ozone. Radiation produced 5.51 x 0.0001 breaks/cell rad for cells withdrawn 2 weeks after exposure, a reasonable value when compared with data from in vivo exposure of human lymphocytes and Chinese hamster bone marrow cells. Animals exposed to the two agents simultaneously exhibited more than 70% of the total breaks anticipated assuming the expected equal contributions to be additive. Extending to humans, at presently permitted levels, exposure to ozone would be much more detrimental than exposure to radiati*n.

Zelac, R. E.↗

Pregalactic black holes - A new constraint

Pregalactic black holes accrete matter in the early universe and produce copious amounts of X radiation. By using observations of the background radiation in the X and gamma wavebands, a strong constraint is imposed upon their possible abundance. If pregalactic black holes are actually present, several outstanding problems of cosmogony can be resolved with typical pregalactic black hole masses of 100 solar masses. Significantly more massive holes cannot constitute an appreciable mass fraction of the universe and are limited by a specific mass-density bound.

Barrow, J. D.↗

Revealing the X-Ray Emission Processes of Old Rotation-Powered Pulsars: XMM-Newton Observations of PSR B0950+08, PSR B0823+26 and PSR J2043+2740

We have completed part of a program to study the X-ray emission properties of old rotation-powered pulsars with XMM-Newton in order to probe and identify the origin of their X radiation. The X-ray emission from these old pulsars is largely dominated by non-thermal processes. None of the observed spectra required adding a thermal component consisting of either a hot polar cap or surface cooling emission to model the data. The energy spectrum of PSR B0950+08 is best described by a single power law of photon-index alpha = 1.93(sup +0.14)(sub -0.12). Three-sigma temperature upper limits for possible contributions from a heated polar cap or the whole neutron star surface are T(sup infinity)(sub pc) < 0.87 x 10(exp 6) K and T(sup infinity)(sub s) < 0.48 x 10(exp 6) K, respectively. We also find that the X-ray emission from PSR B0950+08 is pulsed with two peaks per rotation period. The phase separation between the two X-ray peaks is approx. 144 deg (maximum to maximum) which is similar to the pulse peak separation observed in the radio band at 1.4 GHz. The fraction of X-ray pulsed photons is approx. 30%. A phase resolved spectral analysis confirms the nonthermal nature of the pulsed emission and finds power law slopes of alpha = 2.4(sup +0.52)(sub -0.42) and alpha = 1.93(sup +0.29)(sub -0.24) for the pulse peaks P1 and P2, respectively. The spectral emission properties observed for PSR B0823+26 are similar to those of PSR B0950+08. Its energy spectrum is very well described by a single power law with photon-index alpha = 2.5(sup +0.52)(sub -0.24. Three-sigma temperature upper limits for thermal contributions from a hot polar cap or from the entire neutron star surface are T(sup infinity)(sub pc) < 1.17 x 10(exp 6) K and T(sup infinity)(sub s) < 0.5 x 10(exp 6) K, respectively. There is evidence for pulsed X-ray emission at the - 97% confidence level with a pulsed fraction of 49 +/- 22%. For PSR 52043+2740 we report the first detection of X-ray emission. A power law spectrum, or a combination of a thermal and a power law spectrum all yield acceptable descriptions of its X-ray spectrum. No X-ray pulses are detected from PSR J2043+2740 but the sensitivity is low - the 2-sigma pulsed fraction upper limit is 57% assuming a sinusoidal pulse profile.

Becker, Werner↗

Free-electron crystals for enhanced X-ray radiation

Abstract Bremsstrahlung—the spontaneous emission of broadband radiation from free electrons that are deflected by atomic nuclei—contributes to the majority of X-rays emitted from X-ray tubes and used in applications ranging from medical imaging to semiconductor chip inspection. Here, we show that the bremsstrahlung intensity can be enhanced significantly—by more than three orders of magnitude—through shaping the electron wavefunction to periodically overlap with atoms in crystalline materials. Furthermore, we show how to shape the bremsstrahlung X-ray emission pattern into arbitrary angular emission profiles for purposes such as unidirectionality and multi-directionality. Importantly, we find that these enhancements and shaped emission profiles cannot be attributed solely to the spatial overlap between the electron probability distribution and the atomic centers, as predicted by the paraxial and non-recoil theory for free electron light emission. Our work highlights an unprecedented regime of free electron light emission where electron waveshaping provides multi-dimensional control over practical radiation processes like bremsstrahlung. Our results pave the way towards greater versatility in table-top X-ray sources and improved fundamental understanding of quantum electron-light interactions.

47 OTHER INSTRUMENTATION↗

Bulk modulus measurement at mHz frequencies and high-pressure using synchrotron x-ray radiation

We report an experimental protocol for measuring the frequency dependence of the bulk modulus carried out in a synchrotron x-ray facility based multi-anvil high-pressure apparatus. An oscillating pressure perturbation characterized by x-ray diffraction produces a volume strain measured by imaging. Together, these yield the bulk modulus of the sample. In this work, we report data at 3 mHz as an example of the possibility of providing these data for the frequency range of 1 mHz–100 mHz.

47 OTHER INSTRUMENTATION↗

X ray radiation from Supernova 1987A. The results of the Kvant module in 1987-1989

The results of two years of SN1987A hard X-ray observations by the HEXE instrument aboard the Kvant module are summarized. By May to June 1989, the hard x-ray flux had declined more than 8.5 times in comparison with the maximum of the x-ray light curve. The upper limit of the ratio of Co-57/Co-56 abundances at the level of ratio of Fe-57/Fe-56 abundances at the Earth is a factor of 1.5.

Sunyaev, Rashid A.↗

Probing extreme states of matter using ultra-intense x-ray radiation

Extreme states of matter, that is, matter at extremes of density (pressure) and temperature, can be created in the laboratory either statically or dynamically. In the former, the pressure–temperature state can be maintained for relatively long periods of time, but the sample volume is necessarily extremely small. When the extreme states are generated dynamically, the sample volumes can be larger, but the pressure–temperature conditions are maintained for only short periods of time (ps to μs). In either case, structural information can be obtained from the extreme states by the use of x-ray scattering techniques, but the x-ray beam must be extremely intense in order to obtain sufficient signal from the extremely-small or short-lived sample. In this article I describe the use of x-ray diffraction at synchrotrons and XFELs to investigate how crystal structures evolve as a function of density and temperature. After a brief historical introduction, I describe the developments made at the Synchrotron Radiation Source in the 1990s which enabled the almost routine determination of crystal structure at high pressures, while also revealing that the structural behaviour of materials was much more complex than previously believed. I will then describe how these techniques are used at the current generation of synchrotron and XFEL sources, and then discuss how they might develop further in the future at the next generation of x-ray lightsources.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗