Search NASA⌕ Search

SEARCH · Search NASA

Results for “X ray”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A rocket borne instrument for the study of soft X-ray emission from cosmic X-ray sources

Details about a rocket-borne instrument designed for studying the various characteristics of soft X-ray emission from cosmic X-ray sources in the energy range of 0.2 to 3 keV are presented. The X-ray detector consists of a bank of four multilayer, wall-less proportional counters, each with an area of 400 sq cm. The detectors are covered by windows of 1.4-micron polypropylene and are maintained at a constant pressure in flight using a gas control system. Two of the detectors are equipped with 0.4- by 10-deg collimators for mapping the spatial distribution of soft X-rays from extended X-ray sources. A pair of balanced filters consisting of oxygen and CF4 are used for detecting oxygen emission lines.

Agrawal, P. C.↗

Large area soft x-ray collimator to facilitate x-ray optics testing

The first objective of this program is to design a nested conical foil x-ray optic which will collimate x-rays diverging from a point source. The collimator could then be employed in a small, inexpensive x-ray test stand which would be used to test various x-ray optics and detector systems. The second objective is to demonstrate the fabrication of the x-ray reflectors for this optic using lacquer-smoothing and zero-stress electroforming techniques.

Espy, Samuel L.↗

Transforming Our Understanding of the X-ray Universe: The Imaging X-ray Polarimeter Explorer (IXPE)

Accurate X-ray polarimetry can provide unique information on high-energy-astrophysical processes and sources. As there have been no meaningful X-ray polarization measurements of cosmic sources since our pioneering work in the 1970's, the time is ripe to explore this new parameter space in X-ray astronomy. To accomplish this requires a well-calibrated and well understood system that-particularly for an Explorer mission-has technical, cost, and schedule credibility. The system that we shall present satisfies these conditions, being based upon completely calibrated imaging- and polarization-sensitive detectors and proven X-ray-telescope technology.

Weisskopf, Martin C.↗

X-ray spectra of galactic X-ray sources

The spectroscopic properties of the various classes of Galactic X-ray sources are discussed, with particular emphasis on binary sources containing an accreting compact object, where post-emission scattering in an accretion disk often prevents the initially produced X-radiation from being observed directly. Theoretical interpretations and X-ray observations are considered for the cataclysmic variables, binary systems with a white dwarf as the compact object and which suffer relatively less from Thomson scattering, and the similar phenomenological spectral characteristics of the bulge sources, including soft transients, bursters and steady X-ray sources with thermal spectra, thought to represent an accreting neutron star, are pointed out. The spectral characteristics of X-ray pulsars in accreting binary systems (rather than the Crab pulsar, which is losing rotational kinetic energy with time) are then presented and interpreted in terms of accretion in the polar regions, and mechanisms for the newly discovered X-ray emission from late-type RS CVn stars are considered.

Holt, S. S.↗

On the Nature of the mHz X-ray Quasi-Periodic Oscillations from Ultraluminous X-ray source M82 X−1: Search for Timing-Spectral Correlations

Using all the archival XMM-Newton X-ray (3-10 keV) observations of the ultraluminous X-ray source (ULX) M82 X−1, we searched for a correlation between its variable mHz quasi-periodic oscillation (QPO) frequency and its hardness ratio (5-10 keV/3-5 keV), an indicator of the energy spectral power-law index. When stellar-mass black holes (StMBHs) exhibit type-C low-frequency QPOs (∼0.2-15 Hz), the centroid frequency of the QPO is known to correlate with the energy spectral index. The detection of such a correlation would strengthen the identification of M82 X−1's mHz QPOs as type-C and enable a more reliable mass estimate by scaling its QPO frequencies to those of type-C QPOs in StMBHs of known mass.We resolved the count rates and the hardness ratios of M82 X−1 and a nearby bright ULX (source 5/X42.3+59) through surface brightness modeling.We detected QPOs in the frequency range of 36-210 mHz during which M82 X−1's hardness ratio varied from 0.42 to 0.47. Our primary results are (1) that we do not detect any correlation between the mHz QPO frequency and the hardness ratio (a substitute for the energy spectral power-law index) and (2) similar to some accreting X-ray binaries, we find that M82 X−1's mHz QPO frequency increases with its X-ray count rate (Pearson's correlation coefficient = +0.97). The apparent lack of a correlation between the QPO centroid frequency and the hardness ratio poses a challenge to the earlier claims that the mHz QPOs of M82 X−1 are the analogs of the type-C low-frequency QPOs of StMBHs. On the other hand, it is possible that the observed relation between the hardness ratio and the QPO frequency represents the saturated portion of the correlation seen in type-C QPOs of StMBHs-in which case M82 X−1's mHz QPOs can still be analogous to type-C QPOs.

Nature↗

X ray spectra of X Per

The cosmic X-ray spectroscopy experiment on OSO-8 observed X Per for twenty days during two observations in Feb. 1976 and Feb. 1977. The spectrum of X Per varies in phase with its 13.9 min period, hardening significantly at X-ray minimum. Unlike other X-ray binary pulsar spectra, X Per's spectra do not exhibit iron line emission or strong absorption features. The data show no evidence for a 22 hour periodicity in the X-ray intensity of X Per. These results indicate that the X-ray emission from X Per may be originating from a neutron star in a low density region far from the optically identified Be star.

Becker, R. H.↗

The soft x ray transient Cen X-4 in quiescence

The initial goal of this project was to examine the quiescent X-ray light curve of the recurrent X-ray/optical nova Cen X-4 throughout its 15.1-hr orbital period. Using these observations the pre-outburst conditions of the binary would be investigated and the relationship between soft X-ray transients and persistent low-mass X-ray binaries would be established. ROSAT-PSPC observations were scheduled for 1991 August 9-13. Unfortunately, failure of the satellite's attitude control system near the end of the all-sky survey severely curtailed science operations for much of 1991, and the requested observations of Cen X-4 were never taken. Since the stated goal could not be accomplished, the time and resources of this project were used in support of two other ROSAT programs for which I am co-investigator: 'Identification of LMC X-ray Sources Using ROSAT-HRI Images' and 'X-ray Light Curve for an Eclipsing Black-Hole Binary'. The results of these investigations are described.

Schmidtke, Paul C.↗

X-ray spectra of X Persei

The GSFC cosmic X-ray spectroscopy experiment on OSO 8 observed X Per for 20 days during two observations in 1976 February and 1977 February. The spectrum of X Per varies in phase with its 13.9 minute period, hardening significantly at X-ray minimum. Unlike other X-ray binary pulsar spectra, those of X Per do not exhibit iron line emission or strong absorption features. Our data show no evidence for a 22 hour periodicity in the X-ray intensity of X Per. These results indicate that the X-ray emission from X Per may be originating from a neutron star in a low-density region far from the optically identified Be star.

Becker, R. H.↗

Evidence For Quasi-Periodic X-ray Dips From An Ultraluminous X-ray Source: Implications for the Binary Motion

We report results from long-term (approx.1240 days) X-ray (0.3-8.0 keV) monitoring of the ultraluminous X-ray source NGC 5408 X-1 with the Swift/X-Ray Telescope. Here we expand on earlier work by Strohmayer (2009) who used only a part of the present data set. Our primary results are: (1) the discovery of sharp, quasi-periodic, energy-independent dips in the X-ray intensity that recur on average every 243 days, (2) the detection of an energy dependent (variability amplitude decreases with increasing energy), quasi-sinusoidal X-ray modulation with a period of 112.6 +/- 4 days, the amplitude of which weakens during the second half of the light curve, and (3) spectral evidence for an increase in photoelectric absorption during the last continuous segment of the data. We interpret the X-ray modulations within the context of binary motion in analogy to that seen in high-inclination accreting X-ray binaries. If correct, this implies that NGC 5408 X-1 is in a binary with an orbital period of 243 +/- 23 days, in contrast to the 115.5 day quasi-sinusoidal period previously reported by Strohmayer (2009). We discuss the overall X-ray modulation within the framework of accretion via Roche-lobe overflow of the donor star. In addition, if the X-ray modulation is caused by vertically structured obscuring material in the accretion disk, this would imply a high value for the inclination of the orbit. A comparison with estimates from accreting X-ray binaries suggests an inclination > or approx.70deg. We note that, in principle, a precessing accretion disk could also produce the observed X-ray modulations.

Pasham, Dheeraj R.↗

Imaging and nondispersive spectroscopy of soft X rays using a laboratory X-ray charge-coupled-device system

This paper describes the design and performance of a laboratory instrument for imaging and nondispersive spectroscopy of soft X-rays (300 eV to 10 keV) utilizing a virtual-phase CCD. This instrument has achieved a spatial resolution of 22 microns (limited by pixel size) with an overall array area of 584 x 390 pixels. It has achieved an energy resolution of about 140 eV FWHM for single-pixel Fe-55 X-ray events (5.9 keV) with the CCD operated at -30 C. The CCD has been operated in photon-counting mode at room temperature, and X-ray spectra with an energy resolution of about 450 eV at 5.9 keV have been obtained. The low energy X-ray sensitivity of the CCD also has been demonstrated by detecting carbon K-alpha X-rays (277eV).

Luppino, Gerard A.↗

Discovery of Nearly Coherent Oscillations with a Frequency of approximately 567 Hz During Type I X-ray Bursts of the X-ray Transient and Eclipsing Binary X1658-298

We report the discovery of nearly coherent oscillations with a frequency of approximately 567 Hz during type I X-ray bursts from the X-ray transient and eclipsing binary X1658-298. If these oscillations are directly related to the neutron star rotation, then the spin period of the neutron star in X1658-298 is approximately 1.8 ms. The oscillations can be present during the rise or decay phase of the bursts. Oscillations during the decay phase of the bursts show an increase in frequency of approximately 0.5-1 Hz. However, in one particular burst the oscillations reappear at the end of the decay phase at about 571.5 Hz. This represents an increase in oscillation frequency of about 5 Hz, which is the largest frequency change seen so far in a burst oscillation. It is unclear if such a large change can be accommodated by present models used to explain the frequency evolution of the oscillations. The oscillations at 571.5 Hz are unusually soft compared to the oscillations found at 567 Hz. We also observed several bursts during which the oscillations are detected at much lower significance or not at all. Most of these bursts happen during periods of X-ray dipping behavior, suggesting that the X-ray dipping might decrease the amplitude of the oscillations (although several complications exist with this simple picture). We discuss our discovery in the framework of the neutron star spin interpretation.

Wijnands, Rudy↗

The Comptonization of iron X-ray features in compact X-ray sources

The formation of X-ray spectral features due to iron in a relatively cool cloud of gas with a Thomson depth greater than 1 surrounding a compact source of continuum X-rays is described. Coupled equations are solved for the ionization structure of the cloud and for the radiative transfer of the X-rays. Photoionization suppresses the strength of emission lines and absorption edges. Comptonization of the radiation broadens emission lines, fills in absorption edges, and produces a high-energy cutoff. In order to describe multiple scattering, a Fokker-Planck equation is derived which includes an important modification of the Kompaneets equation. Narrow resonance lines are treated with an escape probability formalism.

Ross, R. R.↗

High resolution X-ray scattering measurements for Advanced X-ray Astrophysics Facility /AXAF/

The Advanced X-ray Astrophysics Facility (AXAF) is to be an orbiting X-ray observatory with high resolution imaging capabilities. Specific goals of 0.5 arcsecond resolution, and an encircled energy of 60% within a 1.0 arcsecond diameter circle at 2.5 keV have been established for AXAF. Imaging X-ray optics are primarily limited by scattering of the X-rays from the mirror surfaces. To ensure that the AXAF goals can be met, comprehensive X-ray scattering measurements are being conducted on a large number of flat samples. Sub-arcsecond resolution is achieved in these measurements through use of the MSFC 1000 ft X-ray calibration facility and a high spatial resolution X-ray detector. Flats of various materials, various coatings, and a range of rms surface roughness are being evaluated. Direct evaluation of surface microroughness is also provided by a variety of optical and non-optical means. This paper describes the scattering measurement program, the instrumentation used to obtain the measurements and preliminary results of measurements on several of the sample flats.

Zombeck, M. V.↗

Hard X-ray Observation of Cygnus X-1 By the Marshall Imaging X-ray Experiment (MIXE2)

The second generation of the Marshall Imaging X-ray Experiment (MIXE2) was flown from Fort Sumner, New Mexico on May 7-8, 1997. The experiment consists of coded-aperture telescope with a field of view of 1.8 degrees (FWHM) and an angular resolution of 6.9 arcminutes. The detector is a large (7.84x10(exp 4) sq cm) effective area microstrip proportional counter filled with 2.0x10(exp5) Pascals of xenon with 2% isobutylene. We present MIXE2 observation of the 20-80keV spectrum and timing variability of Cygnus X-1 made during balloon flight.

Minamitani, Takahisa↗

Observations of Compact X-Ray Binaries with the Chandra X-Ray Observatory

The Chandra X-Ray Observatory Launched on July 23, 1999. The first X-ray photons were detected on August 12 of that same year. Subsequently observations with the Observatory, which features sub-arcsecond angular resolution, have revolutionized our understanding of the X-ray emitting sky providing hosts of spectacular energy-resolved images and high-resolution spectra. Here we present a brief overview of Chandra X-Ray Observatory observations of compact X-ray binaries.

Weisskopf, Martin C.↗

Testing the Pairs-Reflection Model with X-Ray Spectral Variability and X-Ray Properties of Complete Samples of Radio-Selected BL Lacertae Objects

This grant was awarded to Dr. C. Megan Urry of the Space Telescope Science Institute in response to two successful ADP proposals to use archival Ginga and Rosat X-ray data for 'Testing the Pairs-Reflection model with X-Ray Spectral Variability' (in collaboration with Paola Grandi, now at the University of Rome) and 'X-Ray Properties of Complete Samples of Radio-Selected BL Lacertae Objects' (in collaboration with then-graduate student Rita Sambruna, now a post-doc at Goddard Space Flight Center). In addition, post-docs Joseph Pesce and Elena Pian, and graduate student Matthew O'Dowd, have worked on several aspects of these projects. The grant was originally awarded on 3/01/94; this report covers the full period, through May 1997. We have completed our project on the X-ray properties of radio-selected BL Lacs.

Urry, C. Megan↗

X-ray bursters and the X-ray sources of the galactic bulge

Type 1 X-ray bursts, optical, infrared, and radio properties of the galactic bulge sources, are discussed. It was proven that these burst sources are neutron stars in low mass, close binary stellar systems. Several burst sources are found in globular clusters with high central densities. Optical type 1 X-ray bursts were observed from three sources. Type 2 X-ray bursts, observed from the Rapid Burster, are due to an accretion instability which converts gravitational potential energy into heat and radiation, which makes them of a fundamentally different nature from Type 1 bursts.

Lewin, W. H. G.↗