Search NASA⌕ Search

SEARCH · Search NASA

Results for “X-ray image analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Soil porous microstructure control over soil organic matter mobility: A multimethod workflow for understanding chemistry-dependent organic matter binding in soil

Soil organic matter (SOM) has attracted a great deal of interest; particularly for its potential to mitigate human derived CO 2 emissions. Studies have demonstrated that SOM plays a critical role in carbon storage and CO 2 sequestration. However, the sorption properties of SOM, which influence its transport in pore water and stabilization within the soil, remain poorly understood. This study develops a workflow to: (1) examine compound-specific advective and diffusive transport and desorption behaviors, (2) quantify desorption rates through stop-flow and continuous-flow column experiments, and (3) evaluate the impact of soil microporosity on SOM mobility using high-resolution imaging and extractions. Intact core column experiments were conducted on Uncultivated (Natural) and Cultivated soil samples, both were arid soils, collected in Washington State. X-ray computed tomography was employed to measure porosity and pore connectivity, while Fourier-transform ion cyclotron resonance mass spectrometry was used to analyze SOM composition. The findings revealed that cultivation increased total carbon and nitrogen levels due to irrigation and fertilization, enhancing carbon capture potential in arid soils. In contrast, the Natural soil, characterized by higher porosity and connectivity, contained more oxidized carbon. Pore network analysis indicated that soil compaction in the Cultivated soil may lead to longer diffusion pathways, significantly influencing SOM transport and stability.

Hydraulic Properties↗

Synthesis and Properties of Bulk Mg 3 WN 4 in a Wurtzite-Derived Structure

Experimental synthesis of theoretically predicted materials with controlled elemental coordination environments can lead to the realization of useful properties, such as facile ion transport or ferroelectric switching. Among such materials are ternary nitrides in the Mg−W−N composition space, where several stable and metastable compounds have been predicted and synthesized recently in bulk and film forms. Here, we report for the first time on the bulk synthesis of Mg 3 WN 4 in a wurtzite-derived crystal structure via a solid-state metathesis reaction. In situ synchrotron powder X-ray diffraction shows how the ion exchange proceeds from Li 6 WN 4 + MgCl 2 precursors to Mg 3 WN 4 + LiCl products, with the reaction starting slowly near 380 °C and completing by 600 °C, including the presence of a competing disordered rocksalt-derived phase (Mg,W)N above 440 °C. The follow-up ex situ powder synthesis at 400 °C for 0.5 h with 10% excess MgCl 2 reveals the cation-ordered nature of the wurtzite-derived Mg 3 WN 4 structure with polar symmetry confirmed by second-harmonic generation measurements. Optical absorption spectra, chemical composition analysis, and electron microscopy imaging suggest that bulk Mg 3 WN 4 obtained via metathesis reaction is prone to defect formation. Overall, this study shows that selective ex situ synthesis of the phase-pure ternary nitrides, informed by in situ measurements, is possible by carefully controlling the thermal budget of the reaction and paves the way toward property characterization of the Mg 3 WN 4 wurtzite-derived material.

36 MATERIALS SCIENCE↗

Mesoscale Linear Elastic Modeling and Homogenization of Marine Energy Composites

The design of fiber-reinforced composite (FRC)-based components for marine energy applications necessitates a fundamental understanding of material properties and the resulting geometry to predict long-term performance. In this work, we present a modeling workflow to predict linear elastic and diffusive bulk properties at the mesoscale for an idealized geometry based on knowledge of fiber and resin properties. A parametric study was performed to identify the key model input parameters that influence bulk properties. Furthermore, we demonstrate how bulk properties can be leveraged in high-fidelity image-based simulations, where imperfections in tow geometry and voids captured during X-ray computed tomography imaging are explicitly represented within the simulation. Bulk properties of interest include moduli, Poisson’s ratios, hygroscopic swelling, diffusivity, and moisture uptake, which are key parameters for characterizing FRC performance within marine environments. Modeling predictions agreed well with experimental data, except for estimating swelling coefficients, likely due to crack accumulation as a function of moisture uptake. The mesoscale modeling workflow ultimately highlights a versatile framework for understanding the influence of material and geometric properties, which can be leveraged to rapidly assess new FRC-based components.

computational mechanics↗

Machine Learning Framework for Characterizing Processing–Structure Relationship in Block Copolymer Thin Films

The morphology of block copolymers (BCPs) critically influences material properties and applications. This work introduces a machine learning (ML)-enabled, high-throughput framework for analyzing grazing incidence small-angle X-ray scattering (GISAXS) data and atomic force microscopy (AFM) images to characterize BCP thin film morphology. A convolutional neural network was trained to classify AFM images by surface features, achieving 97% testing accuracy. Classified images were then analyzed to extract 2D grain size measurements from the samples in a high-throughput manner. ML models were trained to predict domain orientation based on processing parameters such as solvent ratio, additive type, and additive ratio. GISAXS-based properties were predicted with strong performances (R 2 > 0.75), while AFM-based property predictions were less accurate (R 2 < 0.60), likely due to the localized nature of AFM measurements compared to the bulk information captured by GISAXS. Beyond model performance, interpretability was addressed using SHapley Additive exPlanations (SHAP). SHAP analysis revealed that the additive ratio had the largest impact on morphological predictions, where additive provides the BCP chains with increased volume to rearrange into thermodynamically favorable morphologies. This interpretability helps validate model predictions and offers insight into parameter importance. Altogether, the presented framework combining high-throughput characterization and interpretable ML offers an approach to exploring and optimizing BCP thin film morphology across a broad processing landscape.

36 MATERIALS SCIENCE↗

Spatiotemporal and Statistical Mapping of Transition Metal Equilibria in Alkaline Media

Transition metal dissolution and redeposition (D/R) kinetics in alkaline media play a critical role in various chemical and electrochemical processes. Competitive reaction kinetics between different transition metals can modulate individual metal behavior in these processes. To date, these phenomena have remained largely unmeasured, and even when captured, they are difficult to statistically characterize due to their dynamic nature, simultaneous occurrence, and spatially heterogeneous nature. Here, in this study, we develop a statistical analysis framework based on in situ and operando X-ray fluorescence microscopy (XFM) to investigate the relative D/R kinetics of multiple transition metals in alkaline media. By employing statistical analysis, we quantify the spatial distribution of D/R species and assess the rate at which the system reaches equilibrium under varying reaction conditions. We show that pH does not simply change the rate of dissolution and redeposition, but reorganizes the cross-element kinetic correlations among Ni, Fe, and Mn and accelerates the spatial equilibration of D/R events, as quantified through correlation analysis, reaction-rate estimation, probability function distributions, and texture-based monitoring statistics. Additionally, we demonstrate how modifying the solvent environment can influence D/R kinetics, providing a pathway for tuning materials synthesis and process optimization. Our study offers valuable insights into the complex interplay between different transition metals and provides a reliable statistical framework for spatial analysis of diverse imaging data sets, enabling deeper extraction of latent information across multiple modalities.

36 MATERIALS SCIENCE↗

Chemical imaging of individual stratospheric particles sampled over North America

The increasing size, severity, and frequency of wildfires have led to dramatic increases in particulate matter concentrations in the troposphere. Severe wildfires can generate intense convective systems capable of transporting large quantities of biomass burning organic aerosols (BBOA) to the upper troposphere and lower stratosphere (UTLS). Chemically complex organic matter and light-absorbing carbonaceous material is introduced into stratospheric regions that were historically isolated from direct surface emissions. In this study, stratospheric particles were sampled over North America during the Dynamics and Chemistry of the Summer Stratosphere (DCOTSS) campaign, an aircraft-based research project designed to characterize convective perturbation in the UTLS. Particle samples collected from six research flights during summer 2022 were analyzed using Computer-Controlled Scanning Electron Microscopy and Scanning Transmission X-ray Microscopy to investigate particle size distributions, morphology, chemical composition, and mixing state of stratospheric particles along transects across the continental United States and adjacent Pacific Ocean airspace. Analysis revealed that all sampled particles contained detectable levels of carbon, with most exhibiting organic volume fractions of 0.37 ± 0.20. Notably, about 5% of the particles also contained soot inclusions, which indicates the presence of refractory black carbon transported to stratospheric altitudes and provides direct evidence of wildfire-derived black carbon reaching the UTLS. Typical particle morphology exhibits organic shells over soot and inorganic cores and suggests secondary processing and aging of BBOA during transport to and within the UTLS. These findings provide compelling evidence that wildfire emissions play a critical role in affecting the long-term composition and radiative properties of stratospheric particles.

Sharpe, Steven [Purdue Univ., West Lafayette, IN (↗

Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison

The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼ 5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ± 2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.

Aluminum↗

Blended conventional and high oxygen permeability ionomers as a fuel cell electrode binder

Ionomer strongly influences the performance of proton exchange membrane fuel cells (PEMFCs), affecting catalyst activity and reactant transport within the electrodes. While recent work on high oxygen permeability ionomers (HOPI) has demonstrated improved performance compared to conventional perfluorosulfonic acid (PFSA) ionomers such as Nafion™, there have also been reports of increased cracking in fabricated electrodes. We investigated the effects of blending HOPI with Nafion™ ionomer dispersions when fabricating cathode catalyst layers (CCLs). Small-angle x-ray scattering suggests that the ionomers mix well, and adsorption measurements indicate that HOPI adsorbs less strongly to the carbon-supported platinum (Pt) catalyst, and in blends, the Nafion™ ionomer exhibits a greater degree of adsorption. Imaging CCLs revealed a decrease in crack formation in blended samples as HOPI content decreased, with 14% HOPI having the lowest crack density. In a membrane electrode assembly (MEA) using a high surface area carbon support, the 14% HOPI blend exhibited similar performance to 100% HOPI. However, similar performance enhancements were not achieved with a medium surface area carbon support. These findings suggest a path for low-crack CCLs with enhanced oxygen transport, while highlighting a need for further investigation of ionomer blending towards efficient and durable PEMFCs.

25 ENERGY STORAGE↗

Hyperspectral radiance mapping and chromatic correction for temperature measurement in laser-heated diamond anvil cells

In laser-heated diamond anvil cell (DAC) experiments, the effective heated region typically decreases in size with increasing pressure, leading to steeper thermal gradients. Under these conditions, chromatic aberration in the optical path from sample to detector can significantly create bias in spectro-radiometric temperature measurement. We present a radiance-mapping approach using a hyperspectral camera that records 25 spectral channels spanning 605–875 nm at each pixel in a single exposure, providing spatially and spectrally resolved radiance in each frame. This enables chromatic effects to be recorded and corrected in data processing. We developed a procedure for hyperspectral mapping, involving per-camera calibration, crosstalk removal, measured spectral throughput functions, and optional sub-pixel co-registration to minimize chromatic distortion. The calibrated radiance maps are then used to derive temperature maps of the laser-heated hotspots. For smaller heating spots, the radiance mapping approach reveals chromatic shifts that conventional spectro-radiometric methods cannot quantify. Ambient-pressure heating experiments confirm accurate temperature retrieval. At high pressure, application of the hyperspectral system to a platinum-heating experiment at 12 GPa demonstrates stable temperature reconstruction under steep thermal gradients. Beyond mitigating chromatic aberrations, the ability to diagnose optical artifacts separately from emissivity variations during controlled test experiments or in situ suggests a path toward more rigorous spectral emissivity analysis and improved modeling of thermal transport in laser-heated DAC experiments.

47 OTHER INSTRUMENTATION↗

Adaptively coupled phase retrieval in multi-peak Bragg coherent diffraction imaging

Recent advances in Bragg coherent diffraction imaging (BCDI) experimental techniques permit routine measurement of multiple Bragg peaks from a single crystalline grain. The resulting images contain the full lattice distortion vector field which can be differentiated to provide lattice strain and rotation. With the advent of fourth-generation synchrotron light sources, such multi-peak datasets are produced at high rates, facilitating the need for rapid phase retrieval of the multiple peaks and subsequent image analysis. Here we describe and demonstrate a new implementation of a coupled phase retrieval technique for multi-peak BCDI which simultaneously treats each Bragg peak of the dataset and produces a three-dimensional image of the crystal's morphology and lattice distortion field. In addition, this method uses the redundant information contained in the various Bragg diffraction patterns to detect and suppress spurious signal appearing on the detector in a subset of the measurements. Compared with manual data editing, adaptive coupling produces a more consistent phase profile in reciprocal space and sharper surfaces in direct space, with no significant difference in computational cost. These improvements reduce the need for manual preprocessing and enable robust high-throughput analysis of multi-peak BCDI data, supporting near-real-time strain microscopy at modern synchrotron facilities.

36 MATERIALS SCIENCE↗

Tutorial: Machine-Learning-Based CREASE-2D Analysis of 2D SAXS Profiles to Characterize Anisotropic Nanostructures in Soft Materials

We present a tutorial to guide users on how to extend the Computational Reverse Engineering Analysis of Scattering Experiments-2D (CREASE-2D) framework to interpret their experimental two-dimensional small-angle scattering (SAS) data from soft materials (e.g., polymers, peptide amphiphiles, biomolecular fibrils). Unlike most traditional SAS analysis approaches, which typically rely on azimuthally averaged onedimensional (1D) profiles, CREASE-2D utilizes the complete 2D scattering profile to reveal information about anisotropy in the structure. In past applications, CREASE has provided insights into complex structural features, including the cross-sectional shapes of assembled nanostructures and dispersity in these features, which are difficult to discern with existing analytical models. While (1D- ) CREASE has been applied to SANS and SAXS data, this tutorial shares the steps for implementing CREASE-2D using an example of a dipeptide solution system, for which we have SAXS data. We present details for these steps involved in using CREASE-2D to interpret SAXS profiles: how to preprocess SAXS data, define relevant structural features, generate three-dimensional real-space structures for specific values of these features, train a machine learning (ML) surrogate model to predict scattering profiles for given structural features, and optimize these features using genetic algorithms (GA). Then, we use these steps to interpret complex 2DSAXS data collected from dipeptide solutions that, in microscopy images, exhibit nanoscale structures that could be elliptical tubes/ flat tapes/cylinders or a combination of these cross sections. Open-source codes, computational hardware, and software requirements, as well as the strengths and limitations of this protocol, are also presented. We expect researchers working with (soft) biomaterials, peptide amphiphiles, amphiphilic polymer solutions, polymer nanocomposites, and blends of particles/polymers will find this CREASE-2D method and this tutorial of use.

CREASE↗

Implementation of compound refractive lenses for large field-of-view x-ray phase-contrast imaging during hypervelocity impact experiments

Synchrotron x-ray phase-contrast imaging (XPCI) offers time-resolved visualization of dynamic compression phenomena, but its intrinsically small field-of-view (FOV) limits the time that key features remain in frame. A novel approach to enlarge the FOV is achieved by positioning a two-dimensional parabolic compound refractive lens (CRL) upstream of the sample to deliberately defocus the white beam. Ray-tracing simulations and XPCI measurements show that this CRL configuration can expand the beam by ∼50% vertically and ∼15% horizontally based on the full width at half-maximum of the beam. Implementing the CRL, however, attenuates the photon flux and lowers signal-to-noise ratio (SNR). Task-based analysis using a calibration grid (30 μm dots) showed that both setups fail to consistently meet the Rose criterion (SNR ≥ 5) for features of this size in single-bunch imaging. Extrapolating the measured SNR Rose values suggests that the minimum consistently detectable feature lies closer to 30–40 μm for the standard XPCI setup and above 40 μm for CRL-XPCI. Despite this limitation, the CRL configuration nearly doubles the illuminated area, enabling simultaneous tracking of front and rear observations of boron carbide targets subjected to rod and sphere impacts at 1.0–2.6 km/s. Image tracking algorithms and photonic Doppler velocimetry were used to measure penetration and rear-surface velocity histories. Together, these measurements capture crack fronts, penetration, and material breakout, offering new benchmark data for validating high-strain-rate constitutive models of ceramic materials.

Ceramic materials↗

Combining Deep Learning and scatterControl for High-Throughput X-ray CT Based Non-Destructive Characterization of Large-Scale Casted Metallic Components

X-ray computed tomography (XCT) is essential for nondestructive evaluation and quality control of large-scale metal components. XCT imaging, however, faces significant challenges from metal artifacts, particularly those caused by Compton scattering, which degrade image quality and obscure critical details. Hardware-based solutions (e.g. scatterControl) offer advancements by intercepting scattered photons and reducing artifacts, but they can be time-consuming and require additional processing. Here, we propose modifying and leveraging a novel deep learning (DL) framework, Simurgh, to enhance and accelerate scatter correction in XCT. By combining scatterControl with DL-based artifact removal, we demonstrate significant reduction in scan time while producing high-quality reconstructions. Through extensive evaluation on industrial XCT data, we show that our methods reduce scan time by up to more than 10 x while preserving flaw detectability. Quantitative analysis across multiple segmentation techniques confirms that Simurgh-based reconstructions consistently outperform traditional Feldkamp-Davis-Kress, model-based iterative reconstruction, and commercial DL models in both pixel-level and task-specific evaluations, enabling scalable, high-throughput XCT workflows for characterization of large scale components in applications such as casting and metal additive manufacturing.

Complex metal parts↗

Classifying biophysical subpopulations of insulin secretory granules using quantitative whole-cell structure analysis

Pancreatic beta cells contain insulin secretory granules (ISGs), organelles where proinsulin is converted into insulin. As ISGs mature, they undergo extensive biophysical remodeling, producing a spectrum of subpopulations with heterogeneous molecular and spatial characteristics. However, systematic methods to define ISG subpopulations remain underdeveloped. To address this gap in knowledge, we employed soft X-ray tomography (SXT), which can quantitatively measure the biochemical density of ISGs within whole beta cells. Using unsupervised clustering, we classified subpopulations based on molecular density, size, and spatial positioning. Across different insulin secretory stimuli, we observed shifts toward mature and releasable subtypes, demonstrating that exogenous signals can dynamically remodel ISG subpopulation distributions. We extended this methodology to primary beta cells characterized using volume electron microscopy (vEM). Integrating subpopulations from SXT and vEM uncovered insights inaccessible by a single method in isolation. This strategy establishes a framework for defining therapeutic approaches aimed at enriching physiologically beneficial ISG subpopulations.

dense-core granules↗

Absolute timing calibration of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

The Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM) is designed to have a good timing capability with the mission-level requirement of 1 ms as the absolute time tagging accuracy to suffice the needs for observatory science. In the ground calibration campaign, the absolute and relative timing offsets were measured using pulsed X-rays from the modulated X-ray sources. These offsets were used to determine calibration parameters, the Resolve timing coefficients, which are used in the offline correction of event times. In the orbit, reevaluation of the timing coefficients was carried out using the Crab pulsar, which was observed in two periods, one in the performance verification phase and the other in the guest observation phase. We report the absolute timing calibration of XRISM/Resolve using the ground and in-orbit data. Although the requirement is likely satisfied with the ground parameters, the timing coefficients have been refined using the in-orbit calibration to improve the timing accuracy. In addition, for the first time, we present the interpretation of the absolute timing offset originating from the analog and digital processing of X-ray events unique to a microcalorimeter spectrometer and present a complete view of the timing error of the Resolve instrument.

Astronomy and AstroPhysics↗

Electron–Ion Covariance Reveals Geometry-Resolved Inner-Shell Spectra in CS 2 Photodissociation

The chemical shifts of inner-shell atomic orbitals are highly sensitive to chemical bonding and molecular structure. In evolving systems, however, the spectra of distinct molecular species and geometries overlap, obscuring the underlying chemical dynamics. Here we demonstrate the use of electron–ion covariance analysis to combine the structural sensitivity of Coulomb explosion imaging with inner-shell spectroscopy, yielding geometry-specific spectra of transient and product species. We apply this approach to the excited state dynamics of CS 2 probed by ionization above the S 2p edge. Electron–ion covariance with time- and momentum-selected S + and S 2+ ions isolates distinct S 2p photoelectron spectra for ground-state CS 2 , bent photoexcited CS 2 , the CS photoproduct, and bare atomic sulfur ─ species whose spectra overlap strongly in the channel-averaged measurement. Clear chemical shifts are observed in the covariance photoelectron spectrum for each of these species, all of which are consistent with high-level calculations. Here, by extracting the atomic S contribution to the photoelectron spectrum in a finely time-resolved manner we can disentangle this contribution to the overall time-resolved photoelectron spectrum as the photodissociation proceeds. These results demonstrate the promise of electron–ion covariance as a general approach to geometry-resolved inner-shell spectroscopy, opening a route to tracking structural evolution through chemical shifts in complex photoexcited molecules.

Ionization↗

Imaging Three-Dimensional Molecular Structure and Dynamics with Multiparticle Covariance and Cumulant Coulomb Explosion Analysis

Coulomb explosion imaging (CEI) provides a direct means of imaging molecular geometry by correlating fragment ion momenta following the fragmentation of a molecular polycation. Here, we demonstrate the use of three-body covariance and four-body cumulant analysis to extract three-dimensional (3D) structural information from the X-ray-induced Coulomb explosion of tert-butyl iodide (C4H9I). Site-selective ionization at the iodine 4d edge with intense femtosecond soft X-ray pulses from an X-ray free-electron laser (XFEL) enables rapid charge buildup and molecular breakup. By correlating ionic fragments in the molecular frame, we isolate complete dissociation channels and reveal subtle structural changes, such as umbrella-type motion of the branched alkyl chain, during the ionization process. Comparison with point-charge simulations of the Coulomb explosion shows close agreement, validating the approach. Furthermore, these results establish covariance/cumulant mapping as a powerful strategy for imaging complex three-dimensional molecular structures and point the way toward time-resolved CEI using both XFEL and tabletop sources for capturing ultrafast structural dynamics.

Imaging↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗