Search NASA⌕ Search

SEARCH · Search NASA

Results for “XENON LIGHT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Search for Solar Boosted Dark Matter Particles at the PandaX-4T Experiment

We present a novel constraint on light dark matter utilizing 1.54 metric ton/year of data acquired from the PandaX-4T dual-phase xenon time projection chamber. This constraint is derived through detecting electronic recoil signals resulting from the interaction with solar-enhanced dark matter flux. Low-mass dark matter particles, lighter than a few MeV / c 2 , can scatter with the thermal electrons in the Sun. Consequently, with higher kinetic energy, the boosted dark matter component becomes detectable via contact scattering with xenon electrons, resulting in a few keV energy deposition that exceeds the threshold of PandaX-4T. We calculate the expected recoil energy in PandaX-4T considering the Sun’s acceleration with heavy mediators and the detection capabilities of the xenon detector. The first experimental search results using the xenon detector yield the most stringent upper limits cross section of 3.51 × 10 − 39 cm 2 at 0.08 MeV / c 2 for a solar boosted dark matter mass ranging from 0.02 to 10 MeV / c 2 , achieving a 23-fold improvement compared with earlier experimental studies. Published by the American Physical Society 2025

Shen, Guofang↗

Exploring new physics with O(keV) electron recoils in direct detection experiments

Motivated by the recent XENON 1T results, we explore various new physics models that can be discovered through searches for electron recoils in O(keV)-threshold direct-detection experiments. First, we consider the absorption of axion-like particles, dark photons, and scalars, either as dark matter relics or being produced directly in the Sun. In the latter case, we find that keV mass bosons produced in the Sun provide an adequate fit to the data but are excluded by stellar cooling constraints. We address this tension by introducing a novel Chameleon-like axion model, which can explain the excess while evading the stellar bounds. We find that absorption of bosonic dark matter provides a viable explanation for the excess only if the dark matter is a dark photon or an axion. In the latter case, photophobic axion couplings are necessary to avoid X-ray constraints. Second, we analyze models of dark matter-electron scattering to determine which models might explain the excess. Standard scattering of dark matter with electrons is generically in conflict with data from lower-threshold experiments. Momentum-dependent interactions with a heavy mediator can fit the data with dark matter mass heavier than a GeV but are generically in tension with collider constraints. Next, we consider dark matter consisting of two (or more) states that have a small mass splitting. The exothermic (down)scattering of the heavier state to the lighter state can fit the data for keV mass splittings. Finally, we consider a subcomponent of dark matter that is accelerated by scattering off cosmic rays, finding that dark matter interacting though an O(100 keV)-mass mediator can fit the data. The cross sections required in this scenario are, however, typically challenged by complementary probes of the light mediator. Throughout our study, we implement an unbinned Monte Carlo analysis and use an improved energy reconstruction of the XENON 1T events.

79 ASTRONOMY AND ASTROPHYSICS↗

A data-driven method to estimate contamination from light ion beam transmutation at colliders

Collisions of relativistic light ions such as oxygen, neon, and magnesium, have been proposed as a way to examine the system-size dependence of dynamics typically associated with the quark-gluon plasma produced in collisions of heavier ions such as xenon, gold, or lead. Recent efforts at both the Relativistic Heavy Ion Collider (RHIC) and Large Hadron Collider (LHC) have produced large datasets of proton-oxygen, oxygen-oxygen, and neon-neon collisions, catalyzing intense interest in experimental backgrounds associated with light ion collisions. In particular, electromagnetic dissociation of light ions while they are circulating in a collider can result in beam contamination that is difficult to simulate precisely. Here we propose a data-driven method for evaluating the potential impact of beam contaminants on physics analyses. The method exploits the time-dependence and smaller size of contaminant ion species to define control regions that can be used to quantify potential contamination effects. A simple mode

Accelerator Physics (physics.acc-ph)↗

Data-driven method to estimate contamination from light ion beam transmutation at colliders

Collisions of relativistic light ions, such as oxygen, neon, and magnesium, have been proposed as a way to examine the system-size dependence of dynamics typically associated with the quark-gluon plasma produced in collisions of heavier ions such as xenon, gold, or lead. Recent efforts at both the Relativistic Heavy Ion Collider (RHIC) and Large Hadron Collider (LHC) have produced large datasets of proton-oxygen, oxygen-oxygen, and neon-neon collisions, catalyzing intense interest in experimental backgrounds associated with light-ion collisions. In particular, electromagnetic dissociation of light ions while they are circulating in a collider can result in beam contamination that is difficult to simulate precisely. Here we propose a data-driven method for evaluating the potential impact of beam contaminants on physics analyses. The method exploits the time dependence and smaller size of contaminant ion species to define control regions that can be used to quantify potential contamination effects. A simple model is used to illustrate the method and to study its robustness. Furthermore, this method can inform studies of recent LHC and RHIC data and could also be useful for future light-ion programs at the LHC and beyond.

Beam loss↗

Energy resolution of the LZ detector for high-energy electronic recoils

The LUX-ZEPLIN (LZ) detector is a dual-phase liquid xenon time projection chamber (TPC) installed at the Sanford Underground Research Facility (Lead, South Dakota) at a depth of 1478 meters. Although the main objective of LZ is the direct detection of dark matter, its low background environment allows for the search of other rare processes, such as the neutrinoless double beta decay of xenon isotopes 134 Xe and 136 Xe with the respective Q-values of 826 keV and 2458 keV. The sensitivity of the detector to these decays is directly determined by the energy resolution, which, in turn, is degraded by non-uniformities in detector response. In this work, we present a novel method to correct, in the data, the non-uniformity of the light collected by an array of photosensors in a scintillation detector. This method is based on the knowledge of the light response functions of individual photosensors. With these techniques, we report, at a very early phase of the detector operations, a state-of-the-art energy resolution (σ/μ) of (0.67 ± 0.01)% at 2614 keV for the fiducial volume of 5.6 tonnes of liquid xenon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Understanding spectral dependance of laser-induced damage precursors in dielectric materials (Abbreviated report_23-ERD-006)

High peak and average power laser systems are typically limited by the handling fluence of the optical components. In particular, the multilayer dielectric coatings are known to be much lower operational fluence than the more ideal bulk materials. In this project we proposed and succeeded in probing different established classes of damage prone precursors at different wavelengths to understand their fundamental laser damage response as a function of wavelength. This study helped to shed light on the fundamental physics of the non-linear precursors that govern laser damage phenomena for ns-regime pulsed laser damage. In this study, we utilized the onsite coating capabilities (VPL, IBS coating lab) to purposefully generate laser damage-prone precursors in hafnia-based coatings (both single and multi-layer coatings). Specifically, we engineered coatings with craze lines initiated by nodules, generated coatings with our xenon-based coating process to suppress nanobubble formation and generated hafnia coatings under controlled oxygen flow conditions to study hafnia sub-oxides and oxygen flow dependance. In these studies we found that craze lines are rife with precursors that are sensitive to ultra-violet light but not to infrared light; we found that the removal of nanobubbles helps with all wavelengths tested, but is most impactful for ultra-violet light; we also found that ultra-violet laser damage performance of hafnia is closely matched to oxygen flow rate, while the infrared performance may be slightly better at lower flow rates. During this LDRD we also successfully stood up a new laser damage testing capability, namely a wavelength agile damage test station to study the spectral response of known laser-induced damage precursors. This is a unique and important capability for Lawrence Livermore National Lab, allowing us to understand the spectral response of materials under high intensity irradiation and damage. This is a vital tool to understand non-linear optical response at wavelengths that we have previously been unable to test at.

36 MATERIALS SCIENCE↗

A review of NEST models for liquid xenon and an exhaustive comparison with other approaches

This paper discusses the microphysical simulation of interactions in liquid xenon, the active detector medium in many leading rare-event searches for new physics, and describes experimental observables useful for understanding detector performance. The scintillation and ionization yield distributions for signal and background are presented using the Noble Element Simulation Technique (NEST), a toolkit based on experimental data and simple empirical formulas, which mimic previous microphysics modeling but are guided by data. The NEST models for light and charge production as a function of the particle type, energy, and electric field are reviewed, along with models for energy resolution and final pulse areas. NEST is compared with other models or sets of models and validated against real data, with several specific examples drawn from XENON, ZEPLIN, LUX, LZ, PandaX, and table-top experiments used for calibrations.

WIMPs↗

Developing Advanced Charge Readout Techniques for nEXO and Future Liquid Xenon OVBB Detectors (Final Report)

This award supported the Yale group’s efforts on nEXO, which included the following: 1) Developed techniques for measuring the outgassing of materials into liquid xenon (LXe) and a model for predicting the electron lifetime in nEXO and future LXe TPCs 2) Work to develop the conceptual design for the nEXO Photon Detector subsystem and TPC subsystem interconnections 3) Developed simulation of charge and light propagation and readout in nEXO.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cosmogenic 137 Xe Analysis of Alternatives for nEXO

Neutrinoless double-beta decay is a hypothetical nuclear decay in which two matter particles are produced without corresponding antimatter particles. Observation of neutrinoless double-beta decay would shed light on a potential explanation of matter-antimatter observed in the universe and also indicate the Majorana nature of neutrinos, meaning that the neutrino can act as its own antiparticle. The nEXO experiment is a proposed 5-ton liquid xenon time projection chamber detector with a projected 1.35 × 10 28 yr half-life sensitivity to neutrinoless double-beta decay in 136 Xe [J. Phys. G 49, 015104 (2022)]. While nEXO has a baseline location of SNOLAB, there are several other underground facilities in the world capable of hosting the experiment. The primary change at each site will be cosmogenic 137 Xe backgrounds, caused by varied cosmogenic muon activity at each site. This study finds that while there is a negligible increase in nEXO’s half-life sensitivity at 90% C.L. from improving the cosmogenic 137 Xe veto rejection procedure for SNOLAB, much higher daily muon rates at three other sites will have an adversely negative effect on nEXO’s sensitivity and would likely require further modifications to nEXO’s baseline design to reach nEXO’s scientific goals. Monte Carlo simulations of muons inducing 137 Xe backgrounds were conducted at four underground sites, SNOLAB, SURF, LNGS, and WIPP, each with roughly a factor of 10 times higher daily muon activity than the previous site. There were two primary inputs to these simulations. The first was sample data of cosmogenic muon flight through nEXO’s outer detector, a 12.8m tall and 12.3m wide cylindrical water tank lined with photomultiplier tubes to detect Cerenkov radiation, and all of the secondary interactions produced in the detector. The second input was a parametrization of 137 Xe* production tagging when 137 Xe de-excites and release prompt gammas, as well as accidental tagging caused by neutron capture on 63 Cu, 65 Cu, 19 F, and 1 H throughout the detector. Together, the number of backgrounds relative to the previous 2021 Sensitivity Paper [J. Phys. G 49, 015104 (2022)] was found at each of these four sites across three energy windows, from 400, 1400, and 2600 keV all up to 4600 keV, just above the end point of the prompt gamma spectrum for 137 Xe*. Using level curves for the sensitivity as 137 Xe backgrounds scale relative to baseline calculations, the half-life sensitivity at 90% C.L. for each of trial was found. Even with reduced 137 Xe backgrounds, the results for SNOLAB yielded neglible improvements in nEXO’s predicted sensitivity. On the contrary, the increased backgrounds for the three other considered sites yielded sensitivity estimates below nEXO’s previous projections. This study demonstrates that the shielding from cosmogenic muons at SNOLAB makes it highly preferred even amongst other world leading underground laboratories.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multiple-core-hole resonance spectroscopy with ultraintense X-ray pulses

Understanding the interaction of intense, femtosecond X-ray pulses with heavy atoms is crucial for gaining insights into the structure and dynamics of matter. One key aspect of nonlinear light–matter interaction was, so far, not studied systematically at free-electron lasers—its dependence on the photon energy. Here, we use resonant ion spectroscopy to map out the transient electronic structures occurring during the complex charge-up pathways of xenon. Massively hollow atoms featuring up to six simultaneous core holes determine the spectra at specific photon energies and charge states. We also illustrate how different X-ray pulse parameters, which are usually intertwined, can be partially disentangled. The extraction of resonance spectra is facilitated by the possibility of working with a constant number of photons per X-ray pulse at all photon energies and the fact that the ion yields become independent of the peak fluence beyond a saturation point. Our study lays the groundwork for spectroscopic investigations of transient atomic species in exotic, multiple-core-hole states that have not been explored previously.

74 ATOMIC AND MOLECULAR PHYSICS↗

Fast and flexible analysis of direct dark matter search data with machine learning

We present the results from combining machine learning with the profile likelihood fit procedure, using data from the Large Underground Xenon (LUX) dark matter experiment. This approach demonstrates reduction in computation time by a factor of 30 when compared with the previous approach, without loss of performance on real data. We establish its flexibility to capture non-linear correlations between variables (such as smearing in light and charge signals due to position variation) by achieving equal performance using pulse areas with and without position-corrections applied. Its efficiency and scalability furthermore enables searching for dark matter using additional variables without significant computational burden. We demonstrate this by including a light signal pulse shape variable alongside more traditional inputs such as light and charge signal strengths. Furthermore, this technique can be exploited by future dark matter experiments to make use of additional information, reduce computational resources needed for signal searches and simulations, and make inclusion of physical nuisance parameters in fits tractable.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Operation and performance of a dual-phase crystalline/vapor xenon time projection chamber

We have built and operated a crystalline/vapor xenon TPC, with the goal of improving searches for dark matter. The motivation for this instrument is the fact that beta decays from the radon decay chain to the ground state presently limit the state-of-the-art liquid/vapor xenon experiments. In contrast, a crystalline xenon target has the potential to exclude, or tag and reject radon-chain backgrounds. As a preamble to demonstrating such capabilities, the present article makes a first demonstration of the operation of a crystalline/vapor xenon TPC with electroluminescence (gas gain) for the electron signal readout. It also shows that the scintillation yield in crystalline xenon appears to be identical to that in liquid xenon, in contrast to previous results.

47 OTHER INSTRUMENTATION↗

TinyTPC - A test stand for photosensitive dopants

LArTPCs highly doped with Xenon could be interesting platforms for probing MeV- and sub-MeV physics including neutrinoless-double beta decay. A main hurdle is the small fraction of scintillation photons that are collected, which significantly impacts LArTPCs' energy resolution. One solution is the use of photosensitive dopants, which convert light to charge. A team from Rutgers University and FNAL have built a test stand (TinyTPC) with a LArPix pixelated anode plane and an active mass of 2.1 kg to study these charge enhancements. Our plan is to measure the TinyTPC’s energy resolution with and without dopants for radioactive gamma sources, which is crucial for accurate calorimetric energy reconstruction of low-energy physics signals. The doping agent that will be used is isobutylene and the radiation sources are Co-60, Y-88, and Th-228.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Why would you put a flashlight in a dark matter detector?

Silicon photomultipliers (SiPMs) are solid-state, single-photon sensitive, pixelated sensors whose usage for scintillation detection has rapidly increased over the past decade. It is known that the avalanche process within the device, which renders a single photon detectable, can also generate secondary photons which may be detected by a separate device. This effect, known as external crosstalk, could potentially degrade the science goals of future xenon dark matter experiments. In this article, we measure the effect of external crosstalk in a dual-phase, liquid xenon time projection chamber fully instrumented with SiPMs. We then consider the implications for a future xenon dark matter experiment utilizing SiPMs and discuss possible solutions.

47 OTHER INSTRUMENTATION↗

First results of the NEXT-100 detector using $^{83m}$Kr decays

The NEXT collaboration is investigating the double beta decay of $ ^{136}\mathrm Xe$ using high-pressure gas electroluminescent time projection chambers, which provide excellent energy resolution together with a robust topological signature. Operating at the Laboratorio Subterráneo de Canfranc (LSC) and building on the success of the NEXT-White detector, the NEXT-100 apparatus began commissioning in May 2024 and started operation with xenon at a pressure of 4 bar in October 2024. We report here the first results obtained with NEXT-100 using low-energy calibration data from $^{83\text {m}}\textrm{Kr}$ decays, which allow mapping of the detector response in the active volume and monitoring of its stability over time. After homogenizing the light response, we achieve an energy resolution of 4.37% FWHM at 41.5 keV for $^{83\text {m}}\textrm{Kr}$ point-like energy deposits contained in a radius of 425 mm. In a fiducial region representing the operating conditions of NEXT-100 at 10 bar we obtain an improved energy resolution of 4.16% FWHM. These results are in good agreement with that obtained in NEXT-White, and an $E^{-1/2}$ extrapolation to $Q_{\beta \beta }$ yields an energy resolution close to 0.5% FWHM, well below the 1% FWHM design target.

Martínez-Lema, G. [Donostia Intl. Phys. Ctr., San ↗

Event reconstruction in a liquid xenon Time Projection Chamber with an optically-open field cage

nEXO is a proposed tonne-scale neutrinoless double beta decay (0νββ) experiment using liquid 136 Xe (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe (“skin” LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier around the field cage. Here, in this work, we show that the light originating in the skin LXe region can be used to improve background discrimination by 5% over previous published estimates. This improvement comes from two elements. First, a fraction of the γ-ray background is removed by identifying light from interactions with an energy deposition in the skin LXe. Then, background from 222 Rn dissolved in the skin LXe can be efficiently rejected by tagging the α decay in the 214 Bi- 214 Po chain in the skin LXe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DIREXENO—an apparatus for measuring correlated scintillation signatures in liquid xenon

We present a detector apparatus, DIREXENO (DIREctional XENOn), designed to measure the spatial and temporal properties of scintillation in liquid xenon to very high accuracy. The properties of scintillation are of primary importance for dark matter and neutrinoless double beta decay experiments; however the complicated microphysics involved limits theoretical predictions. We will explore the possibility that scintillation emission exhibits spatial correlations such as super-radiance which manifests in temporal and spatial structure, depending on the interaction type. Such properties of scintillation light may open a new window for background rejection as well as directionality measurements. We present the apparatus' technical design and the concepts driving it. We demonstrate that for an energy deposition of ~2.5 keV (~7.5 keV) electron (nuclear) recoil the detector is sensitive to an anisotropy fraction of as little as ~ 20% of the total photons emitted over a solid angle of ~0.85 steradian or less. We show results from commissioning runs in which the detector operated with 17 PMTs for over 44 days in stable conditions. The time resolution for individual photons in different PMTs was measured to be ≲1.4 ns full-width at half-maximum

47 OTHER INSTRUMENTATION↗

Ultrafast Laser-Excited Optical Emission of Xe under Loose-Focusing Conditions

The optical filament-based radioxenon sensing can potentially overcome the constraints of conventional detection techniques that are relevant for nuclear security applications. This study investigates the spectral signatures of pure xenon (Xe) when excited by ultrafast laser filaments at near-atmosphericpressure and in short and loose-focusing conditions. The two focusing conditions lead to laser intensity differences of several orders of magnitude and different plasma transient behavior. The gaseous sample was excited at atmospheric pressure using ∼7 mJ pulses with a 35 fs pulse duration at 800 nm wavelength. The optical signatures were studied by time-resolved spectrometry and imaging in orthogonal light collection configurations in the ∼400 nm (VIS) and ∼800 nm (NIR) spectral regions. The most prominent spectral lines of atomic Xe are observable in both focusing conditions. An on-axis light collection from an atmospheric air–Xe plasma mixture demonstrates the potential of femtosecond filamentation for the remote sensing of noble gases.

47 OTHER INSTRUMENTATION↗