Search NASA⌕ Search

SEARCH · Search NASA

Results for “XRF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Evaluation of photon irradiation treatment upon calcium content of ribs of Wistar rats using micro-XRF

Therapeutic doses of radiation have been shown to have deleterious consequences on bone health. Among the treatment strategies used for breast cancer treatment, the most used are radiotherapy and chemotherapy. Radiotherapy may be given to destroy the cancer cells using high-dose x-rays. Protocols vary considerably, but generally whole body irradiation totals from 10 to 15 Gy, whereas local therapy totals from 40 to 70 Gy. In clinical practice, the quantitative evaluation of bone tissue relies on measurements of bone mineral density values, which are closely associated with the risk of osteoporotic fracture. Improved survivorship rates of cancer patients receiving radiotherapy increase the importance of understanding the mechanisms and long-term effects of radiation-induced bone loss. In this work, we investigated the variation on calcium distribution in ribs of female Wistar rats (Rattus norvegicus) submitted to photon irradiation with a single dose of 20 Gy. The determination of the calcium distribution was performed using synchrotron radiation microfluorescence (SR-{mu}XRF) at the X-ray Fluorescence beamline at Brazilian Synchrotron Light Laboratory (LNLS). Animals were irradiated using the linear accelerator Varian registered (CLINAC 2100) at the University Centre for Cancer Control of the State University of Rio de Janeiro (CUCC/UERJ). The total dose delivered was 20 Gy. The animals were about three months old and weighting about 200g. They were distributed into two groups (seven per group): control (did not receive any treatment) and irradiated (submitted to irradiation procedure) groups. Results showed that calcium content decreased within the dorsal ribs of rats submitted to radiotherapy in comparison to the control group.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Commissioning of a microprobe-XRF beamline (BL-16) on Indus-2 synchrotron source

We report commissioning of the microprobe-XRF beamline on Indus-2 synchrotron source. The beamline has been recently made operational and is now open for the user's experiments. The beamline comprises of Si(111) double crystal monochromator and Kirkpatrick-Baez focusing optics. The beamline covers wide photon energy range of 4 - 20 keV using both collimated and micro-focused beam modes. The design details and the first commissioning results obtained using this beamline are presented.

43 PARTICLE ACCELERATORS↗

Experimental study for the feasibility of using hard x-rays for micro-XRF analysis of multilayered metals

Application of polycapillary optical systems to improve a spatial resolution for the μ-XRF analysis by focusing a primary x-ray beam and/or by collecting fluorescence emission is well known. The challenge is to optimize them in combination with x-ray source for exciting K-lines above 20 keV that could allow characterization of many materials composed by heavy elements. To pursue this goal, preliminary studies on possible polycapillary lens employment in thickness determination for multilayer metal materials will be presented in this work. In this paper, the results of first attempts of integrating PyMCA with Monte Carlo simulation code (XMI-MSIM) that takes into account the secondary fluorescence effects on quantitative analysis of homogeneous matrices, in particular, metal alloys, are presented.

36 MATERIALS SCIENCE↗

Trace elemental analysis of school chalk using energy dispersive X-ray florescence spectroscopy (ED-XRF)

The present studies focus the quantitative analysis of elements in school chalk to ensure the safety of its use. The elements like Calcium (Ca), Aluminum (Al), Iron (Fe), Silicon (Si) and Chromium (Cr) were analyzed from settled chalk dust samples collected from five classrooms (CD-1) and also from another set of unused chalk samples collected from local market (CD-2) using Energy Dispersive X-Ray florescence(ED-XRF) spectroscopy. Presence of these elements in significant concentrations in school chalk confirmed that, it is an irritant and occupational hazard. It is suggested to use protective equipments like filtered mask for mouth, nose and chalk holders. This study also suggested using the advanced mode of techniques like Digital boards, marker boards and power point presentations to mitigate the occupational hazard for classroom chalk.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

HOW UNUSUAL IS XRF 060218?

Light curves are calculated for an off-axis observer due to the scattering of primary radiation by extended baryonic material. The unusually long duration and the chromaticity of the light curves above several KeV of XRF 060218 can be explained as a result of the acceleration of the baryonic scattering material by the primary radiation. The observed light curves by our model and detailed fits to the data are presented. The model predicts that {approx} 4 x 10{sup 48} erg are put into accelerated, mildly relativistic baryons by the radiation pressure at large radii from the central engine. It is suggested that the emission below 3 KeV, which lies below the Amati relation, is a baryon contaminated fireball.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-element effects on arsenate accumulation in a geochemical matrix determined using µ-XRF, µ-XANES and spatial statistics

Soils regulate the environmental impacts of trace elements, but direct measurements of reaction mechanisms in these complex, multi-component systems can be challenging. The objective of this work was to develop approaches for assessing effects of co-localized geochemical matrix elements on the accumulation and chemical speciation of arsenate applied to a soil matrix. Synchrotron X-ray fluorescence microprobe (µ-XRF) images collected across 100 µm × 100 µm and 10 µm × 10 µm regions of a naturally weathered soil sand-grain coating before and after treatment with As(V) solution showed strong positive partial correlations ( r ' = 0.77 and 0.64, respectively) between accumulated As and soil Fe, with weaker partial correlations ( r ' > 0.1) between As and Ca, and As and Zn in the larger image. Spatial and non-spatial regression models revealed a dominant contribution of Fe and minor contributions of Ca and Ti in predicting accumulated As, depending on the size of the sample area analyzed. Time-of-flight secondary ion mass spectrometry analysis of an area of the sand grain showed a significant correlation ( r = 0.51) between Fe and Al, so effects of Fe versus Al (hydr)oxides on accumulated As could not be separated. Fitting results from 25 As K -edge microscale X-ray absorption near-edge structure (µ-XANES) spectra collected across a separate 10 µm × 10 µm region showed ~60% variation in proportions of Fe(III) and Al(III)-bound As(V) standards, and fits to µ-XANES spectra collected across the 100 µm × 100 µm region were more variable. We find that, consistent with insights from studies on model systems, the results obtained here indicate a dominance of Fe and possibly Al (hydr)oxides in controlling As(V) accumulation within microsites of the soil matrix analyzed, but the analyses inferred minor augmentation from co-localized Ti, Ca and possibly Zn.

58 GEOSCIENCES↗

Performance of a Borehole XRF Spectrometer for Planetary Exploration

We have designed and constructed a borehole XRF Spectrometer (XRFS) as part of the Mars Subsurface Access program. It will be used to determine the composition of the Mars regolith at various depths by insertion into a pre-drilled borehole. The primary performance metrics for the instrument are the lower limits of detection over a wide range of the periodic table. Power consumption during data collection was also measured. The prototype instrument is complete and preliminary testing has been performed. Terrestrial soil Standard Reference Materials were used as the test samples. Detection limits were about 10 weight parts-per-million for most elements, with light elements being higher, up to 1.4 weight percent for magnesium. Power consumption (excluding ground support components) was 12 watts.

Kelliher, Warren C.↗

The Use of Handheld X-Ray Fluorescence (XRF) Technology in Unraveling the Eruptive History of the San Francisco Volcanic Field, Arizona

While traditional geologic mapping includes the examination of structural relationships between rock units in the field, more advanced technology now enables us to simultaneously collect and combine analytical datasets with field observations. Information about tectonomagmatic processes can be gleaned from these combined data products. Historically, construction of multi-layered field maps that include sample data has been accomplished serially (first map and collect samples, analyze samples, combine data, and finally, readjust maps and conclusions about geologic history based on combined data sets). New instruments that can be used in the field, such as a handheld xray fluorescence (XRF) unit, are now available. Targeted use of such instruments enables geologists to collect preliminary geochemical data while in the field so that they can optimize scientific data return from each field traverse. Our study tests the application of this technology and projects the benefits gained by real-time geochemical data in the field. The integrated data set produces a richer geologic map and facilitates a stronger contextual picture for field geologists when collecting field observations and samples for future laboratory work. Real-time geochemical data on samples also provide valuable insight regarding sampling decisions by the field geologist

Young, Kelsey E.↗

Nondestructive Analysis of Apollo Samples by Micro-CT and Micro-XRF Analysis: A PET Style Examination

An integral part of any sample return mission is the initial description and classification of returned samples by the preliminary examination team (PET). The goal of a PET is to characterize and classify the returned samples, making this information available to the general research community who can then conduct more in-depth studies on the samples. A PET strives to minimize the impact their work has on the sample suite, which often limits the PET work to largely visual measurements and observations like optical microscopy. More modern techniques can also be utilized by future PET to nondestructively characterize astromaterials in a more rigorous way. Here we present our recent analyses of Apollo samples 14321 and 14305 by micro-CT and micro-XRF (respectively), assess the potential for discovery of "new" Apollo samples for scientific study, and evaluate the usefulness of these techniques in future PET efforts.

Zeigler, Ryan A.↗

Maia Mapper: high definition XRF imaging in the lab

Here, Maia Mapper is a laboratory μXRF mapping system for efficient elemental imaging of drill core sections serving minerals research and industrial applications. It targets intermediate spatial scales, with imaging of up to ~80 M pixels over a 500×150 mm 2 sample area. It brings together (i) the Maia detector and imaging system, with its large solid-angle, event-mode operation, millisecond pixel transit times in fly-scan mode and real-time spectral deconvolution and imaging, (ii) the high brightness MetalJet D2 liquid metal micro-focus X-ray source from Excillum, and (iii) an efficient XOS polycapillary lens with a flux gain ~15,900 at 21 keV into a ~32 μm focus, and (iv) a sample scanning stage engineered for standard drill-core sections. Count-rates up to ~3 M/s are observed on drill core samples with low dead-time up to ~1.5%. Automated scans are executed in sequence with display of deconvoluted element component images accumulated in real-time in the Maia detector. Application images on drill core and polished rock slabs illustrate Maia Mapper capabilities as part of the analytical workflow of the Advanced Resource Characterisation Facility, which spans spatial dimensions from ore deposit to atomic scales.

47 OTHER INSTRUMENTATION↗

Spectral Data Fusion From Handheld Laser-Induced Breakdown Spectroscopy (LIBS) and X-ray Fluorescence (XRF) Analyzers for Improved Detection of Cerium in a Simulated Dispersal Accident

Here, this work implements a mid-level data fusion methodology on spectral data from handheld X-ray fluorescence and laser-induced breakdown spectroscopy analyzers to quantify plutonium surrogate (CeO 2 ) contamination in soil samples for the first time. Spectral data from each analyzer were used independently to train supervised machine learning regressions to predict Ce concentration. Fused features from both data sets were then used to train the same models, comparing prediction performance by evaluating model precision and sensitivity. Fusing principal component scores from the two sensors yielded an order of magnitude improvement in precision and sensitivity of predictions made with an artificial neural network, compared to predictions made by models trained on independent sensor data. As a result, a boosted ensemble trained on the fused spectral features yielded an ideal predictor with root-mean-squared error on the order of 10 –6 and calculated limit of detection order 10 –5 wt %.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Portable X-Ray Fluorescence (XRF) Analyzer for Zirconium-Thickness Measurements

This Technical Evaluation Report provides details of preliminary testing/experiments performed using a handheld X-ray fluorescence analyzer. The analyzer will be utilized in upcoming fuel-foil-rolling optimization studies at the INL. The studies are being performed in support of DOE’s Office of Global Threat Reduction -- Reactor Conversion Subprogram. Details of the equipment used, operating parameters, and measurement results are provided in this report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

100-OL-1 Operable Unit Pilot Study: XRF Evaluation of Select Pre-Hanford Orchards

Prior to the acquisition of land by the U.S. Department of War in February 1943 and the creation of the Hanford Site, the land along the Columbia River was home to over 1000 people. Farming and orchard operations by both homesteaders and commercial organizations were prevalent. Orchard activities and the associated application of lead arsenate pesticide ceased in 1943, when residents were moved from the Hanford Site at the beginning of the Manhattan Project. Today, the residues from historical application of lead arsenate pesticide persist in some locations on the Hanford Site

100-OL-1↗

Locating trace plutonium in contaminated soil using micro-XRF imaging

Micro-X-ray fluorescence (MXRF) was used to locate minute quantities of plutonium in contaminated soil. Because the specimen had previously been prepared for analysis by scanning electron microscopy, it was coated with gold to eliminate electron beam charging. However, this significantly hindered efforts to detect plutonium by MXRF. The gold L peak series present in all spectra increased background counts. Plutonium signal attenuation by the gold coating and severe peak overlap from potassium in the soil prevented detection of trace plutonium using the Pu Mα peak. However, the 14.3 keV Pu Lα peak sensitivity was not optimal due to poor transmission efficiency through the source polycapillary optic, and the instrument silicon drift detector sensitivity quickly declines for peaks with energies above ~10 keV. Instrumental parameters were optimized (eg. using appropriate source filters) in order to detect plutonium. An X-ray beam aperture was initially used to image a majority of the specimen with low spatial resolution. A small region that appeared to contain plutonium was then imaged at high spatial resolution using a polycapillary optic. Small areas containing plutonium were observed on a soil particle, and iron was co-located with the plutonium. Zinc and titanium also appeared to be correlated with the plutonium, and these elemental correlations provided useful plutonium chemical state information that helped to better understand its environmental transport properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pixel-Registered Multimodal Synchrotron XRF and FTIR Microscopies Reveal Salinity Stress Response Mechanisms in Pistachio

Background: Salinity is a major abiotic stress that negatively affects nearly all plant species at all stages of growth. Drought and poor-quality irrigation cause high soil salinity and salt accumulation via evaporation, reducing crop productivity. Despite its critical importance, the spatial localization of salt ions and associated biochemical changes within plants experiencing high salinity remains largely unknown. In this study, we developed a multimodal imaging pipeline to understand the impact of salinity on the pistachio rootstock UCB-1 (Pistacia atlantica x Pistacia integerrima). We directly link biochemical fingerprints in stem tissue architecture with salt ion localization to provide insights into the strategies pistachio uses to tolerate salinity. Results: We observed that Pistacia spp. exposed to high salt conditions accumulated Ca, Si, Cl, Al and Mg as hotspots within the pith, compared to the control (of which only Ca and Al co-locate). In contrast, there was a decrease in K between the control and salinity treatment. Hotspots of amide I and II were present in the cortex and pith of the salinity treated sample. Additionally, the salinity treatment resulted in an increased abundance of pectin and carbohydrates within the pith compared to the control, and the abundance of esters/carboxylic acid was greater in the salinity treatment. Conclusions: We determined that Cl and K, S and P, and biochemical components polysaccharide and pectin, esters and carboxylic acid, amide I and cellulose are the strongest drivers of salinity- treatment induced variability. In the cortex and phloem/xylem, a negative K-Ca correlation decreases in the salinity treatment. Several hotspots of elements and amide I (proteins) appear under salinity treatment, particularly in the cortex, suggesting an increase in the production of stress-related proteins (in response to high Cl) and/or structural proteins (i.e. Ca). Together, these results indicate that pistachio responds to salinity through ion compartmentalization coupled with a targeted biochemical adjustment, rather than a broadscale tissue-wide response. Overall, these novel, spatially resolved pixel-registered multimodal imaging data provide an enabling platform to understand the mechanisms of salinity tolerance in Pistacia spp and can be broadly applied to studying stress-related phenotype response in various plant tissues.

FTIR spectromicroscopy↗

Developing a system for in vivo imaging of maize roots containing iodinated contrast media in soil using synchrotron XCT and XRF

We sought to develop a novel experimental system which enabled application of iodinated contrast media to in vivo plant roots intact in soil and was compatible with time-resolved synchrotron X-ray computed tomography imaging. The system was developed to overcome issues of low contrast to noise within X-ray computed tomography images of plant roots and soil environments, the latter of which can complicate image processing and result in the loss of anatomical information. To demonstrate the efficacy of the system we employ the novel use of both synchrotron X-ray computed tomography and synchrotron X-ray fluorescence mapping to capture the translocation of the contrast media through root vasculature into the leaves. With the application of contrast media we identify fluid flow in root vasculature and visualise anatomical features, which are otherwise often only observable in ex vivo microscopy, including: the xylem, metaxylem, pith, fibres in aerenchyma and leaf venation. We are also able to observe interactions between aerenchyma cross sectional area and solute transport in the root vasculature with depth. Our novel system was capable of successfully delivering sufficient contrast media into root and leaf tissues such that anatomical features could be visualised and internal fluid transport observed. We propose that our system could be used in future to study internal plant transport mechanisms and parameterise models for fluid flow in plants.

59 BASIC BIOLOGICAL SCIENCES↗