Search NASA⌕ Search

SEARCH · Search NASA

Results for “Zero Boil Off”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Zero-G Report ''LH2 Boiling Threshold"

Test to determine minimum temperature difference between heated wall and liquid hydrogen at boiling point required to initiate nucleate boiling under steady state conditions and zero-g.

WALL TEMPERATURE↗

Long Duration Storage of Liquid Hydrogen via Two-Stage Active Cooling Hardware Characterization and Test Planning

The zero boil-off storage of liquid hydrogen using active cooling (cryocoolers) with a two-stage cooling approach is being investigated by NASA. In interest of advancing the technology to enable extended duration storage for the agency’s future long duration missions, NASA’s Technology Demonstration Mission Program has funded this five-year effort which includes the design, build and testing of a test article to demonstrate this concept. This paper includes discussions of the multiple Cryogenic Fluid Management technologies that were studied under NASA’s Cryogenic Propellant Storage and Transfer project, design of the test article to be demonstrated, then the planned test objectives which include characterization testing of the active cooling system, demonstration of the control system, preliminary testing with liquid nitrogen, and a complete demonstration of zero boil-off storage of liquid hydrogen. The full demonstration will be conducted in the East Test Area at NASA Marshall Space Flight Center and is currently scheduled to begin on October 1st, 2024.

Cryogenic Fluid Management↗

Cryogenic Fluid Management Technology for Moon and Mars Missions

In support of the U.S. Space Exploration Policy, focused cryogenic fluid management technology efforts are underway within the National Aeronautics and Space Administration. Under the auspices of the Exploration Technology Development Program, cryogenic fluid management technology efforts are being conducted by the Cryogenic Fluid Management Project. Cryogenic Fluid Management Project objectives are to develop storage, transfer, and handling technologies for cryogens to support high performance demands of lunar, and ultimately, Mars missions in the application areas of propulsion, surface systems, and Earth-based ground operations. The targeted use of cryogens and cryogenic technologies for these application areas is anticipated to significantly reduce propellant launch mass and required on-orbit margins, to reduce and even eliminate storage tank boil-off losses for long term missions, to economize ground pad storage and transfer operations, and to expand operational and architectural operations at destination. This paper organizes Cryogenic Fluid Management Project technology efforts according to Exploration Architecture target areas, and discusses the scope of trade studies, analytical modeling, and test efforts presently underway, as well as future plans, to address those target areas. The target areas are: liquid methane/liquid oxygen for propelling the Altair Lander Ascent Stage, liquid hydrogen/liquid oxygen for propelling the Altair Lander Descent Stage and Ares V Earth Departure Stage, liquefaction, zero boil-off, and propellant scavenging for Lunar Surface Systems, cold helium and zero boil-off technologies for Earth-Based Ground Operations, and architecture definition studies for long term storage and on-orbit transfer and pressurization of LH2, cryogenic Mars landing and ascent vehicles, and cryogenic production via in situ resource utilization on Mars.

Doherty, Michael P.↗

Large Scale Cryogenic Storage with Active Refrigeration

Storage and transfer of cryogenic liquefied gases on volume scales from under 10 liters for lab use, up to hundreds of millions of liters for industrial applications is of paramount importance across a vast range of industries. Traditionally, these commodities have been stored at or near the normal boiling point due to relative ease of operation and safety-related considerations; however, this also means that some percentage will always be lost due to environmental heat leaking into the vessel and causing boil-off. These losses become more concerning as scales increase, and are of particular importance for high-cost commodities such helium and hydrogen. Additionally, the normal boiling point marks the highest liquid density achievable; which becomes a strong driver of end-use system designs such as space launch vehicles. Recent development and testing of an Integrated Refrigeration and Storage (IRAS) system for liquid hydrogen has proven that next generation cryogenic storage operations such as zero boil-off and densification are feasible on a large scale. This IRAS system married an 850 Watt at 20 Kelvin reverse-Brayton cycle commercial cryogenic refrigerator with a 125,000 liter LH2 storage tank via and internal tubular heat exchanger. This allowed heat to be removed directly from the hydrogen, and by extension, provided a means to control the bulk thermodynamic state. Zero boil-off, in-situ liquefaction, and densification down to the triple point was performed during testing, and data such as fluid temperature profiles and tank pressure were gathered. Details regarding the design, setup, and testing of the IRAS system are discussed herein, and the data used to anchor various physics models created to predict the behavior of the system during transient and steady state operation. It is hoped that these efforts will provide a useful basis for the design and implementation of future large scale IRAS systems across numerous industries.

Swanger, Adam M.↗

Cryogenic Boil-Off Reduction System Testing

Cryogenic propellants such as liquid hydrogen (LH2) and liquid oxygen (LO2) are a part of NASA's future space exploration due to the high specific impulse that can be achieved using engines suitable for moving 10's to 100's of metric tons of payload mass to destinations outside of low earth orbit. However, the low storage temperatures of LH2 and LO2 cause substantial boil-off losses for missions with durations greater than several days. The losses can be greatly reduced by incorporating high performance cryocooler technology to intercept heat load to the propellant tanks and by the integration of self-supporting multi-layer insulation. The active thermal control technology under development is the integration of the reverse turbo- Brayton cycle cryocooler to the propellant tank through a distributed cooling network of tubes coupled to a shield in the tank insulation and to the tank wall itself. Also, the self-supporting insulation technology was utilized under the shield to obtain needed tank applied LH2 performance. These elements were recently tested at NASA Glenn Research Center in a series of three tests, two that reduced LH2 boil-off and one to eliminate LO2 boil-off. This test series was conducted in a vacuum chamber that replicated the vacuum of space and the temperatures of low Earth orbit. The test results show that LH2 boil-off was reduced 60% by the cryocooler system operating at 90K and that robust LO2 zero boil-off storage, including full tank pressure control was achieved.

Propellant Storage↗

An Active Broad Area Cooling Model of a Cryogenic Propellant Tank with a Single Stage Reverse Turbo-Brayton Cycle Cryocooler

As focus shifts towards long-duration space exploration missions, an increased interest in active thermal control of cryogenic propellants to achieve zero boil-off of cryogens has emerged. An active thermal control concept of considerable merit is the integration of a broad area cooling system for a cryogenic propellant tank with a combined cryocooler and circulator system that can be used to reduce or even eliminate liquid cryogen boil-off. One prospective cryocooler and circulator combination is the reverse turbo-Brayton cycle cryocooler. This system is unique in that it has the ability to both cool and circulate the coolant gas efficiently in the same loop as the broad area cooling lines, allowing for a single cooling gas loop, with the primary heat rejection occurring by way of a radiator and/or aftercooler. Currently few modeling tools exist that can size and characterize an integrated reverse turbo-Brayton cycle cryocooler in combination with a broad area cooling design. This paper addresses efforts to create such a tool to assist in gaining a broader understanding of these systems, and investigate their performance in potential space missions. The model uses conventional engineering and thermodynamic relationships to predict the preliminary design parameters, including input power requirements, pressure drops, flow rate, cycle performance, cooling lift, broad area cooler line sizing, and component operating temperatures and pressures given the cooling load operating temperature, heat rejection temperature, compressor inlet pressure, compressor rotational speed, and cryogenic tank geometry. In addition, the model allows for the preliminary design analysis of the broad area cooling tubing, to determine the effect of tube sizing on the reverse turbo-Brayton cycle system performance. At the time this paper was written, the model was verified to match existing theoretical documentation within a reasonable margin. While further experimental data is needed for full validation, this tool has already made significant steps towards giving a clearer understanding of the performance of a reverse turbo-Brayton cycle cryocooler integrated with broad area cooling technology for zero boil-off active thermal control.

Guzik, Monica C.↗

Characterization Testing of a 20 Kelvin Cryocooler for Space Applications

Future NASA space exploration missions will require long-duration storage and liquefaction of cryogenic liquids, enabled by active cooling provided by cryocoolers. Recent gap analyses of Lunar and Mars transportation systems have identified 20 K-class cryocoolers as a critical enabling technology for chemical and nuclear thermal propulsion architectures using liquid hydrogen propellant. To address this technology gap, NASA has undergone the development of a high-efficiency, high-capacity 20 K cryocooler via an SBIR partnership with Creare. While the January 2025 testing demonstrated functionality and compliance with contractual requirements, the objective of the NASA-led characterization effort was to generate a dataset for supporting future mission designs across a broader operating envelope, including off-nominal conditions. The cryocooler demonstrated strong performance, achieving a peak coefficient of performance of 17.68% relative to Carnot efficiency and a maximum lift capacity of 24.4 W at 21 K. Overall, the results confirm that the 20 W 20 K cryocooler provides a flexible range of capabilities to enable zero boil-off storage of liquid hydrogen for future Lunar and Mars missions. The data collected provide a strong foundation for model validation and future system design efforts.

Zero boil-off↗

Characterization Testing of a 20 Kelvin Cryocooler for Space Applications

Future NASA space exploration missions will require long-duration storage and liquefaction of cryogenic liquids, enabled by active cooling provided by cryocoolers. Recent gap analyses of Lunar and Mars transportation systems have identified 20 K-class cryocoolers as a critical enabling technology for chemical and nuclear thermal propulsion architectures using liquid hydrogen propellant. To address this technology gap, NASA has undergone the development of a high-efficiency, high-capacity 20 K cryocooler via an SBIR partnership with Creare. While the January 2025 testing demonstrated functionality and compliance with contractual requirements, the objective of the NASA-led characterization effort was to generate a dataset for supporting future mission designs across a broader operating envelope, including off-nominal conditions. The cryocooler demonstrated strong performance, achieving a peak coefficient of performance of 17.68% relative to Carnot efficiency and a maximum lift capacity of 24.4 W at 21 K. Overall, the results confirm that the 20 W 20 K cryocooler provides a flexible range of capabilities to enable zero boil-off storage of liquid hydrogen for future Lunar and Mars missions. The data collected provide a strong foundation for model validation and future system design efforts.

Cryocooler↗

The ZBOT-NC Experiment - Effects of Non-Condensable Gases on Propellant Tank Pressurization and Pressure Control

Introduction Integral to all phases of NASA’s projected planetary expeditions is affordable and reliable cryogenic fluid storage for use in propellant or life support systems. It is greatly advantageous to develop innovative vent-less pressure control designs based on cooling/mixing of the bulk tank fluid to allow storage of the cryogenic fluid with zero or reduced boil-off. The presence of noncondensable gases, can interfere with the condensation at the interface impacting tank pressure control during subcooled jet mixing especially in microgravity. The Zero-Boil-Off Tank (ZBOT) Experiments are a series of small-scale experiments aboard the International Space Station (ISS) that use a transparent volatile simulant fluid in a transparent sealed tank to delineate various fundamental fluid flow, heat and mass transport, and phase change phenomena associated with storage tank pressurization and pressure control in microgravity. The ZBOT-1 experiment was performed on the ISS 2017-2018 timeframe and collected data to validate a state-of-the-art CFD model for tank pressurization and pressure control for a pure system. The ZBOT-NC Experiment is the second experiment in the series to be performed on the International Space Station (ISS) in 2025. Its goal is to investigate the effects of noncondensable gases on interfacial evaporation and condensation during self -pressurization and jet-mixing pressure control in microgravity for a two-component system. Materials & Methods In this work, we will describe the detailed features of the ZBOT-NC experimental hardware and Diagnostics that includes nonintrusive Quantum Dot Thermometry (QDT) for whole field temperature measurement. All microgravity pressurization and pressure control tests will be performed for both the pure and the two-components systems with Xenon and Neon as the two noncondensable gases spanning small and large molecular weights and sizes. The two-phase CFD model that is developed as part of the project will be also presented and discussed. Results Ground-based pressurization and jet mixing experiments and CFD simulation results are compared to each other to validate both the fidelity of the CFD model predictions and the accuracy of the QDT measurement. Model simulations for noncondensable gas effects will also be compared against large Cryogenic LH2-GHe experiments to indicate the noncondensable gas effects on tank pressure control during jet mixing in 1G. Finally, CFD results will be presented to predict the effects of the noncondensable gas during subcooled jet mixing during the ZBOT-NC in advance of the microgravity experiment in 2015.

Evaporation Condensation↗

Integrated Refrigeration and Storage of LNG for Compositional Stability

Growing interest in liquefied natural gas (LNG) as a rocket fuel necessitates a greater technical understanding of the compositional changes due to preferential boil-off (or weathering) that occurs during long duration storage. The purity of methane in LNG can range from 90 to 98%, and is subject to preferential boil-off due to its low boiling point compared to other constituents despite the use of high-performance thermal insulation systems. Active heat extraction (i.e. refrigeration) is required to completely eliminate weathering. For future operational safety and reliability, and to better understand the quality and efficiency of the LNG as a cryofuel, a 400-liter Cryostat vessel was designed and constructed to measure the composition and temperatures of the LNG at a number of different liquid levels over long durations. The vessel is the centerpiece of a custom-designed lab-scale integrated refrigeration and storage (IRaS) system employing a pulse tube cryocooler capable of roughly 50 W of lift at 100 K. Instrumentation includes ten temperature sensors mounted on a vertical rake and five liquid sample tubes corresponding to five liquid levels. Two modes of operation are studied. The first is without refrigeration in order to determine a baseline in the change in composition, and to study stratification of the LNG. The second is performed with the cryocooler active to determine the operational parameters of the IRaS system for eliminating the weathering as well as stratification effects in the bulk liquid. The apparatus design and test method, as well as preliminary test results are presented in this paper. As a bonus in cost-saving and operational efficiency, the capability of the IRaS system to provide zero-loss capabilities such as zero boil-off (ZBO) keeping of the LNG and zero-loss filling/transfer operations are also discussed.

Rose, Laura P.↗