Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerated exposures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Ground Testing of the MISSE-16 Materials

External spacecraft materials play an important role in satellite protection from the harsh space environment. Research has shown that the physical, chemical, and optical properties of matter change continuously as a result of exposure to solar radiation and aggressive chemical species produced in Earth’s upper atmosphere. Thorough knowledge of the material properties evolution throughout a planned mission lifetime helps to improve the reliability of spacecraft. Moreover, the establishment of correlation factors between true space exposure and accelerated space weather experiments at ground facilities enables accurate prediction of on-orbit material performance based on laboratory-based testing. The presented work aims to evaluate the radiation effects of low Earth orbit (LEO) environment, namely, exposure to the high-energy electrons and atomic oxygen (AO), of heritage and novel spacecraft materials selection. The studied materials represent the “flight duplicates” of samples that are launched as a part of the 16th Materials International Space Station Experiment Flight Facility (MISSE-FF) mission in 2022.

Elena A. Plis↗

Spacecraft Materials Degradation Under Space-Simulated Low Earth Orbit (LEO) Environment

External spacecraft materials play an important role in satellite protection from the harsh space environment. Research has shown that the physical, chemical, and optical properties of matter change continuously as a result of exposure to solar radiation and aggressive chemical species produced in Earth’s upper atmosphere. Thorough knowledge of the material properties evolution throughout a planned mission lifetime helps to improve the reliability of spacecraft. Moreover, the establishment of correlation factors between true space exposure and accelerated space weather experiments at ground facilities enables accurate prediction of on-orbit material performance based on laboratory-based testing. The presented work aims to evaluate the radiation effects of low Earth orbit (LEO) environment, namely, exposure to the high-energy electrons, atomic oxygen (AO), and vacuum ultraviolet (VUV), of several modern spacecraft materials. The studied materials represent the “flight duplicates” of samples that are launched as a part of the 16th Materials International Space Station Experiment Flight Facility (MISSE-FF) mission in 2022.

Elena Plis↗

The Alcoa ram fastener: A reusable blind rivet

Results of tensile, shear, fatigue and accelerated weathering tests are presented for the ram fastener, a reusable, single unit blind rivet. The effects of variations in hole size, grip length and sheet thickness on strength properties of the fastener were determined. The test results show these fasteners to have strength characteristics suitable for light structural applications. Exposure to accelerated weathering did not impair their performance.

Dewalt, W. J.↗

Environmental exposure effects on composite materials for commercial aircraft

The data base for composite materials' properties as they are affected by the environments encountered in operating conditions, both in flight and at ground terminals is expanded. Absorbed moisture degrades the mechanical properties of graphite/epoxy laminates at elevated temperatures. Since airplane components are frequently exposed to atmospheric moisture, rain, and accumulated water, quantitative data are required to evaluate the amount of fluids absorbed under various environmental conditions and the subsequent effects on material properties. In addition, accelerated laboratory test techniques are developed are reliably capable of predicting long term behavior. An accelerated environmental exposure testing procedure is developed, and experimental results are correlated and compared with analytical results to establish the level of confidence for predicting composite material properties.

Gibbons, M. N.↗

Lunar Transport Vehicle Ocupant Protection Requirements

INTRODUCTION The National Aeronautics and Space Administration (NASA) is preparing for future Artemis missions that will return humans to the lunar surface. A critical piece of these future missions is the Lunar Transport Vehicle (LTV), a transportation device to be used on the lunar surface. A vehicular method of transportation will allow for longer duration missions with increased capabilities to conduct research and transport soil, geological samples, or other materials of interest. The objective of this project is to provide occupant protection guidance for the design of the LTV. METHODS At the time of writing of occupant protection requirements, much of the LTV design is unknown. However, several general assumptions have been established. It is assumed that the LTV will be an unpressurized crewed rover with the occupant(s) wearing an EVA suit. Additionally, the occupant must be protected using established health limits as governing criteria to protect the occupant from hazardous levels of acceleration, jerk, and vibration. In addition to the health limits, it is expected that the LTV shall provide a comfortable transportation solution to Lunar operations. Several restraint configurations have been considered to allow for seated and standing operation of the vehicle. RESULTS Preliminary recommendations and metrics were put forward by a cross functional working group with members from Johnson Space Center and Ames Research Center. Exposure to acceleration, vibration, and jerk metrics above the proposed limits could create a risk of occupant injury. In addition to satisfying crew health needs, these limits permit the occupant to meet performance objectives including operating the vehicle and reading displays while traversing the Lunar surface. Initial guidance was refined during a Technical Interchange Meeting with external subject matter experts in industry, academia, and United States Air Force. CONCLUSION Operating a crewed vehicle in a lunar environment is a novel problem with few analogs to provide data. Based on terrestrial data from ISO & MIL Standards, occupant protection recommendations have been identified with several assumptions made about reduced gravity and deconditioned occupants. If the design of the vehicle attenuates energetics to levels below those put forward, there is high confidence the occupant will be able to repetitively operate the vehicle without physical harm or operational issues.

K Dolick↗

Environmental Exposure Effects on Composite Materials for Commercial Aircraft

The test program concentrates on three major areas: flight exposure; ground based exposure; and accelerated environmental effects and data correlation. Among the parameters investigated were: geographic location, flight profiles, solar heating effects, ultraviolet degradation, retrieval times, and test temperatures. Data from the tests can be used to effectively plan the cost of production and viable alternatives in materials selection.

Hoffman, D. J.↗

Bed Rest and Orthostatic-Hypotensive Intolerance

Orthostatic tolerance may be defined as the ability of humans to maintain cerebral perfusion and consciousness upon movement from a supine or sitting position to the upright posture; for example, subjects can stand suddenly or be tilted to the head-up body position. Similar but not identical physiological responses can be induced by positive G(sub Z) (head to foot) acceleration or exposure to lower body negative pressure (LBNP). The objective is to suddenly shift blood to the lower body to determine how effectively cardiovascular and neural-hormonal compensatory responses react to maintain blood pressure. In the most precise method for measuring tolerance, individuals would be stressed until they faint (syncope). However, the potential consequences and discomforts of such a test usually prohibit such a procedure so that few investigators actually induce syncope. In a more common approach, subjects are exposed to a given level of stress, for example, head-up tilt for 15 min, and any increases in heart rate or decreases in blood pressure are interpreted as indicators of progress toward syncope. Presumably, the greater the perturbation of heart rate and blood pressure, the closer to "tolerance," i.e., point of unconsciousness. Another more appropriate approach is to induce a progressively increasing hypotensive stress until pre-determined physiological responses or pre-syncopal symptoms appear. The physiological criteria may include a sudden drop in systolic blood pressure (greater than 25 mm/min), a sudden drop in heart rate (greater than 15 beats/min), or a systolic blood pressure less than 70 mmHg. The most common pre-syncopal symptoms include lightheadedness, stomach awareness or distress, feelings of warmth, tingly skin, and light to profuse sweating. Usually a combination of physiological responses and symptoms occurs such that, on different days, the tolerance time to the same orthostatic protocol is reproducible for a given individual. The assumption is that by taking subjects to near fainting, one can determine their tolerance. This latter pre-syncopal approach is better for estimating orthostatic or hypotensive tolerance than the former measurement of heart rate and blood pressure responses to a given stress. There is considerable variability in individual responses to orthostasis. For example, some subjects are "heart-rate responders" and have a pronounced cardiovascular response similar to that when performing moderately hard aerobic exercise, whereas others may experience pre-syncopal symptoms with very little increase in heart rate. Some individuals have a slow, gradual fall in blood pressure to orthostasis, and others have little change in blood pressure until a sudden precipitous fall in pressure occurs just prior to fainting. With both tilt and LBNP tests there is a low correlation between heart-rate or blood-pressure responses to a sub-tolerance stress as a measure of pre-syncopal limited orthostatic-hypotensive tolerance.

Schneider, Suzanne M.↗

Surface Cracking and Interface Reaction Associated Delamination Failure of Thermal and Environmental Barrier Coatings

In this paper, surface cracking and interface reactions of a BSAS coating and a multi-layer ZTO2-8wt%Y2O3 and mullite/BSAS/Si thermal and environmental barrier coating system on SiC/SiC ceramic matrix composites were characterized after long-term combined laser thermal gradient and furnace cyclic tests in a water vapor containing environment. The surface cracking was analyzed based on the coating thermal gradient sintering behavior and thermal expansion mismatch stress characteristics under the thermal cyclic conditions. The interface reactions, which were largely enhanced by the coating surface cracking in the water vapor environment, were investigated in detail, and the reaction phases were identified for the coating system after the long- term exposure. The accelerated coating delamination failure was attributed to the increased delamination driving force under the thermal gradient cyclic loading and the reduced interface adhesion due to the detrimental interface reactions.

Zhu, Dongming↗

Surface Cracking and Interface Reaction Associated Delamination Failure of Thermal and Environmental Barrier Coatings

In this paper, surface cracking and interface reactions of a BSAS coating and a multi-layer ZrO2-8wt%Y2O3 and mullite/BSAS/Si thermal and environmental barrier coating system on SiC/SiC ceramic matrix composites were characterized after long-term combined laser thermal gradient and furnace cyclic tests in a water vapor containing environment. The surface cracking was analyzed based on the coating thermal gradient sintering behavior and thermal expansion mismatch stress characteristics under the thermal cyclic conditions. The interface reactions, which were largely enhanced by the coating surface cracking in the water vapor environment, were investigated in detail, and the reaction phases were identified for the coating system after the long-term exposure. The accelerated coating delamination failure was attributed to the increased delamination driving force under the thermal gradient cyclic loading and the reduced interface adhesion due to the detrimental interface reactions.

Zhu, Dong-Ming↗

Surface Cracking and Interface Reaction Associated Delamination Failure of Thermal and Environmental Barrier

In this paper, surface cracking and interface reactions of a ZrO2-8wt%Y2O3 and mullite/BSAS/Si thermal and environmental barrier coating system on SiC/SiC ceramic matrix composites were characterized after long-term combined laser thermal gradient and furnace cyclic tests in a water vapor containing environment. The surface cracking was analyzed based on the coating thermal gradient sintering behavior and thermal expansion mismatch stress characteristics under the thermal cyclic conditions. The interface reactions that were largely enhanced by the coating surface cracking in the water vapor environment were investigated in detail, and the reaction phases were identified for the coating system after the long-term exposure. The accelerated coating delamination failure was attributed to the increased delamination driving force under the thermal gradient cyclic loading and the reduced interface adhesion due to the detrimental interface reactions. The coating design issues will also be discussed based on the observed failure mechanisms under the high-heat-flux test conditions.

Zhu, Dongming↗

Use of DSC and DMA to Study Rubber Crystallization as a Possible Cause for a Tear in a Neoprene Glove Used in a Space Shuttle Pressurized Astronaut Suit

The Advanced Crew Escape Suit (ACES) is a pressurized suit normally worn by astronauts during launch and landing phases of Space Shuttle operations. In 2008, a large tear (0.5 -1 in. long, between the pinky and ring finger) in the ACES left-hand glove made of neoprene latex rubber was found during training for Shuttle flight STS-124. An investigation to help determine the cause(s) of the glove tear was headed by the NASA Johnson Space Center (JSC) in Houston, Texas. Efforts at JSC to reproduce the actual glove tear pattern by cutting/tearing or rupturing were unsuccessful. Chemical and material property data from JSC such as GC-MS, FTIR, DSC and TGA mostly showed little differences between samples from the torn and control gloves. One possible cause for the glove tear could be a wedding ring/band worn by a male astronaut. Even with a smooth edge, such a ring could scratch the material and initiate the tear observed in the left-hand glove. A decision was later made by JSC to not allow the wearing of such a ring during training or actual flight. Another possible cause for the ACES glove tear is crystallinity induced by strain in the neoprene rubber over a long period of time and use. Neoprene is one several elastomeric materials known to be susceptible to crystallization, and such a process is accelerated with exposure of the material to cold temperatures plus strain. When the temperature is lowered below room temperature, researchers have shown that neoprene crystallization may be maintained at temperatures as high as 45-50 F, with a maximum crystallization rate near 20-25 F (1). A convenient conditioning temperature for inducing neoprene crystallization is a typical freezer that is held near 0 F. For work at the NASA Marshall Space Flight Center (MSFC), samples were cut from several areas/locations (pinky/ring finger crotch, index finger and palm) on each of two pairs of unstrained ACES gloves for DSC and DMA thermal analysis testing. The samples were conditioned in a freezer for various times up to about 14 days. Some rectangular conditioned samples were unstrained, while most were subjected to strains up to 250% with the aid of two slotted aluminum blocks and two aluminum clamps per sample. Trends were observed to correlate DSC data (heat of fusion) and DMA data (linear CTE and stress for iso-strain testing) with: (a) sample location on each glove; and (b) level of strain during conditioning. Control samples cut as is from each glove location were also tested by DSC and DMA.

Wingard, Doug↗

Ambulation Increases Decompression Sickness in Altitude Exposure

INTRODUCTION - Exercise accelerates inert gas elimination during oxygen breathing prior to decompression (prebreathe), but may also promote bubble formation and increase the risk of decompression sickness (DCS). The timing, pattern and intensity of exercise are likely critical to the net effect. The NASA Prebreathe Reduction Program (PRP) combined oxygen prebreathe and exercise preceding a 4.3 psi exposure in non-ambulatory subjects (a microgravity analog) to produce two protocols now used by astronauts preparing for extravehicular activity (CEVIS and ISLE). Additional work is required to investigate whether exercise normal to 1 G environments increases the risk of DCS over microgravity simulation. METHODS - The CEVIS protocol was replicated with one exception. Our subjects completed controlled ambulation (walking in place with fixed cadence and step height) during both preflight and at 4.3 psi instead of remaining non-ambulatory throughout. Decompression stress was graded with aural Doppler (Spencer 0-IV scale). Two-dimensional echocardiographic imaging was used to look for left heart gas emboli (the presence of which prompted test termination). Venous blood was collected at three points to correlate Doppler measures of decompression stress with microparticle (cell fragment) accumulation. Fisher Exact Tests compared test and control groups. Trial suspension would occur when DCS risk >15% or grade IV venous gas emboli (VGE) risk >20% (at 70% confidence). RESULTS - Eleven person-trials were completed (9 male, 2 female) when DCS prompted suspension. DCS was greater than in CEVIS trials (3/11 [27%] vs. 0/45 [0%], respectively, p=0.03). Statistical significance was not reached for peak grade IV VGE (2/11 [18%] vs. 3/45 [7%], p=0.149) or cumulative grade IV VGE observations per subject-trial (8/128 [6%] vs. 26/630 [4%], p=0.151). Microparticle data were collected for 5/11 trials (3 with DCS outcomes), with widely varying patterns that could not be resolved statistically. CONCLUSION - We did find that that ambulation increases decompression stress. Additional trials would improve the statistical power to assess differences in VGE and to evaluate the relationship between decompression stress and microparticles.

Conkin, Johnny↗

Human visual response to nuclear particle exposures

Experiments with accelerated helium ions were performed in an effort to localize the site of initial radiation interactions in the eye that lead to light flash observations by astronauts during spaceflight. The character and efficiency of helium ion induction of visual sensations depended on the state of dark adaptation of the retina; also, the same events were seen with different efficiencies and details when particle flux density changed. It was concluded that fast particles cause interactions in the retina, particularly in the receptor layer, and thus give rise to the sensations of light flashes, streaks, and supernovae.

Tobias, C. A.↗

Space Radiation Shielding Studies for Astronaut and Electronic Component Risk Assessment

The dosimetry component of the Center for Radiation Engineering and Science for Space Exploration (CRESSE) will design, develop and characterize the response of a suite of radiation detectors and supporting instrumentation and electronics with three primary goals that will: (1) Use established space radiation detection systems to characterize the primary and secondary radiation fields existing in the experimental test-bed zones during exposures at particle accelerator facilities. (2) Characterize the responses of newly developed space radiation detection systems in the experimental test-bed zones during exposures at particle accelerator facilities, and (3) Provide CRESSE collaborators with detailed dosimetry information in experimental test-bed zones.

Fuchs, Jordan Robert↗