Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Nonlinear integrable optics beam dynamics experiment and diagnostics

All present circular particle accelerators are built around linear focusing optics. Un-avoidable nonlinear elements appear in accelerators, such as magnetic aberrations and space-charge effects, which are typically corrected using nonlinear magnets. However, these added nonlinearities degrade particle beam stability, and in most cases, the system becomes non-integrable. The Integrable Optics Test Accelerator (IOTA), at Fermi National Accelerator Laboratory (Fermilab), is a test bed to study beam dynamics in integrable lattices for both electron and proton beams, independently. This work presents experimental results of the nonlinear electron beam dynamics behavior in IOTA using an elliptical nonlinear magnet. The elliptical nonlinear magnet allows for a large betatron tune spread, allowing for a stable high-intensity beam. In a future experimental run, minimally invasive beam instrumentation is needed to study time-dependent collective instabilities, and halo formation in space-chargedominated proton beams. Traditional profile monitors are too destructive to the beam or just measure one dimension of the beam. A gas sheet can be injected perpendicular to theproton beam at an angle. By doing so, a two-dimensional, turn-by-turn, transverse profile measurement can be made, which will preserve the integrity of the beam. The developmentand progress of a gas sheet beam profile monitor will also be presented.

43 PARTICLE ACCELERATORS↗

Time-Resolved Beam Position Measurements for the Scorpius Multipulse Linear Induction Accelerator

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements. Although accurate BPM measurements of beam current require correction of magnetic field diffusion, accurate measurement of beam position requires no correction. In this note, we present a theoretical derivation and the experimental validation of this result.

43 PARTICLE ACCELERATORS↗

Magnetic-Field Diffusion Effects in Beam Position Monitors III: Application to DARHT-II Beam Data

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements. Although accurate BPM measurements of beam current require correction of magnetic field diffusion, accurate measurement of beam position requires no correction. In this note, we present experimental validation of current and position results from a prototype detector employing finite conductivity sensing areas, based on experiments on the DARHT-II LIA.

43 PARTICLE ACCELERATORS↗

A differentiable simulation package for performing inference of synchrotron-radiation-based diagnostics

The direction of particle accelerator development is ever-increasing beam quality, currents and repetition rates. This poses a challenge to traditional diagnostics that directly intercept the beam due to the mutual destruction of both the beam and the diagnostic. An alternative approach is to infer beam parameters non-invasively from the synchrotron radiation emitted in bending magnets. However, inferring the beam distribution from a measured radiation pattern is a complex and computationally expensive task. To address this challenge we present SYRIPY ( SYnchrotron Radiation In PYthon ), a software package intended as a tool for performing inference of synchrotron-radiation-based diagnostics. SYRIPY has been developed using PyTorch , which makes it both differentiable and able to leverage the high performance of GPUs, two vital characteristics for performing statistical inference. The package consists of three modules: a particle tracker, Lienard–Wiechert solver and Fourier optics propagator, allowing start-to-end simulation of synchrotron radiation detection to be carried out. SYRIPY has been benchmarked against SRW , the prevalent numerical package in the field, showing good agreement and up to a 50× speed improvement. Finally, we have demonstrated how SYRIPY can be used to perform Bayesian inference of beam parameters using stochastic variational inference.

43 PARTICLE ACCELERATORS↗

Status of the laser manipulations of H- beam at J-PARC

The laser manipulations of H- ion beam by single or double neutralization is a very promising technique and highly essential to utilized in accelerator processes such as stripping, pulse chopping, collimation, extraction, and beam diagnostics for the present and future high-intensity proton accelerators. At J-PARC, we are preparing for a POP (Proof-of-Principle) demonstration 400 MeV H- stripping by using only lasers. A prototype YAG laser system and a laser cavity system to reduce the laser power are being developed through 3 MeV H- neutralization studies. Fermilab utilizes H- neutralization at 0.75 MeV by establishing a laser Notcher system for a gap in the H- pulse needed for a clean beam extraction from the ring. To minimize the laser power and maximize the interaction efficiency are common issue at both laboratories. Under the US-Japan collaboration for high-intensity neutrino beam, we are closely working to establish recycling/reusing of seed laser pulses to reduce a size of the laser system. In parallel, we have also developed non-destructive beam diagnostic systems at lower H- energy of 3 MeV, which will be implemented to the 400 MeV as well as easily applicable to the Fermilab linac including PIP-II linac. Installation of the laser system at J-PARC linac for 400 MeV H- stripping is ongoing to start the POP experimental study in 2023.

43 PARTICLE ACCELERATORS↗

The Accelerator and Beam Physics of the Muon g-2 Experiment at Fermilab

The physics case of the Muon g-2 Experiment at Fermilab is outstanding and has recently attracted significant attention from its first official results. Although its measurements involve high energy physics methods, such as counting positron production rates with the use of calorimeters and beam diagnostics with tracking detectors, this experiment is strongly bound to accelerator and beam physics. This paper reviews the principles of the experiment and the details necessary to provide a solid ground for the beam-dynamics uncertainties and the corrections of the systematic effects influencing the output of the experiment: a single numerical value, which may unveil new physics.

43 PARTICLE ACCELERATORS↗

Development of a novel bunch oscillation recorder with RFSoC technology

The SuperKEKB accelerator is designed to achieve unprecedented luminosity levels, but this goal is currently hindered by Sudden Beam Loss (SBL) events. These events not only obstruct luminosity improvement but also pose a significant risk to accelerator components, the Belle II detectors, and the superconducting focusing system, potentially leading to severe damage and quenching of the superconducting system. Here, to address this critical challenge, we have developed a novel Bunch Oscillation Recorder (BOR) based on RFSoC technology. The BOR has demonstrated high precision with a position resolution of 0.03 mm, making it a powerful tool for real-time beam monitoring. In its initial deployment, the BOR successfully recorded multiple SBL events, providing valuable data for further analysis. By strategically positioning BORs at the suspected points of SBL origin, we aim to directly identify sources of beam instability. We anticipate that this portable, high-speed BOR monitor will play a crucial role in resolving the SBL issue, ultimately helping achieve SuperKEKB's luminosity targets.

Beam diagnostics↗

Magnetic-Field Diffusion Effects in Beam Position Monitors II: Application to Calibration Single-Pulse Data

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. From first principles, we have derived the perturbation to BPM measurements due to this effect. The theoretical framework was used to design an algorithm for signal correction that does not require knowledge of the time history of the magnetic flux being measured. Corrected signals based on that process compared favorably with the know reference signals in a laboratory calibration test sequence.

43 PARTICLE ACCELERATORS↗

Wakefield generation in hydrogen and lithium plasmas at FACET-II: Diagnostics and first beam-plasma interaction results

Plasma wakefield acceleration provides ultrahigh acceleration gradients of tens of GeV/m, providing a novel path toward efficient, compact, TeV-scale linear colliders, and high brightness free electron lasers. Critical to the success of these applications is demonstrating simultaneously high gradient acceleration, high energy transfer efficiency, and preservation of emittance, charge, and energy spread. Experiments at the FACET-II National User Facility at SLAC National Accelerator Laboratory aim to achieve all of these milestones in a single-stage plasma wakefield accelerator, providing a 10 GeV energy gain in a < 1 m plasma with high energy transfer efficiency. Such a demonstration depends critically on diagnostics able to measure emittance with mm mrad accuracy, energy spectra to determine both percent level energy spread, and broadband energy gain and loss, incoming longitudinal phase space, and matching dynamics. This paper discusses the experimental setup at FACET-II, including the incoming beam parameters from the FACET-II linac, plasma sources, and diagnostics developed to meet this challenge. Initial progress on the generation of beam ionized wakes in meter-scale hydrogen gas is discussed as well as commissioning of the plasma sources and diagnostics. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Measurement techniques using the electron beam profile scanner at the Fermilab Main Injector

This work presents techniques for non-invasive transverse profile measurements of high-intensity proton beams using an Electron Beam Profile Scanner (EBPS). The EBPS utilizes low-energy electrons as a probe to analyze the transverse size of proton beams, allowing for potential analysis on a single-bunch basis. Recent upgrades to the Fermilab Main Injector have enhanced beam power on target to 1 MW, with future developments targeting 2 MW. The higher beam power has increased the demand for non-invasive diagnostics, as invasive methods can disrupt operations.The techniques presented include 1) the slow scan technique, which serves as a proof of concept for the probe beam, 2) the one-shot scan technique for measuring horizontal beam profiles, and 3) the raster scan technique for analyzing horizontal beam profiles as a function of the longitudinal distribution of the beam. The profiles obtained will be crucial for studying and understanding instabilities in high-power, high-intensity proton beams. This will contribute to optimizing the operation of high-power proton accelerators by minimizing beam loss, activation, and damage to both the diagnostics and the accelerator components.

Mwaniki, Matilda [IIT, Chicago]↗

Efficient six-dimensional phase space reconstructions from experimental measurements using generative machine learning

Next-generation accelerator concepts, which hinge on the precise shaping of beam distributions, demand equally precise diagnostic methods capable of reconstructing beam distributions within six-dimensional position-momentum spaces. However, the characterization of intricate features within six-dimensional beam distributions using current diagnostic techniques necessitates a substantial number of measurements, using many hours of valuable beam time. Novel phase space reconstruction techniques are needed to reduce the number of measurements required to reconstruct detailed, high-dimensional beam features in order to resolve complex beam phenomena and as a feedback in precision beam shaping applications. In this study, we present a novel approach to reconstructing detailed six-dimensional phase space distributions from experimental measurements using generative machine learning and differentiable beam dynamics simulations. We demonstrate that this approach can be used to resolve six-dimensional phase space distributions from scratch, using basic beam manipulations and as few as 20 two-dimensional measurements of the beam profile. We also demonstrate an application of the reconstruction method in an experimental setting at the Argonne Wakefield Accelerator, where it is able to reconstruct the beam distribution and accurately predict previously unseen measurements 75× faster than previous methods.

43 PARTICLE ACCELERATORS↗

An Improved Beam Position Monitor for Scorpius and the DARHT Multi-Pulse Test Line

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). A frequently used BPM detector is the B-dot loop, which generates a signal from the EMF generated by the time varying magnetic flux through the loop. We have developed a second generation BPM that avoids previously observed diffusion effects in earlier stainless steel through the use of exceptionally high conductivity copper alloy for its construction.

43 PARTICLE ACCELERATORS↗

Optimization of a buncher for High Energy H- Beam Transport [Slides]

Accelerators and beam transport systems typically contain numerous beamline devices, diagnostics, system study, and upgrade. Routinely TRACE, MADX and TRANSPORT codes are used for the beam envelope prediction and optimization. Unknown problems of accelerators and beam-transport are addressed based on R&D, such as LFB voltage variation effect study. A nominal diagnostic have used in non-traditional beam transport path to address scientific question (such as use of a BPM in the air). High energy beam operation is a methodical process and routine R&D is required to maintain high standards to deliver beam.

43 PARTICLE ACCELERATORS↗

Spot Size Optimization of the Scorpius Accelerator

The Scorpius Linear Induction Accelerator (LIA) is being developed by the Advanced Sources and Diagnostics (ASD) Project and will complement other U1a capabilities by providing a multi-pulse, DARHT-class, flash-radiography capability. Commissioning activities are expected to end in Spring of 2026. All of the diagnostics discussed in this chapter are relevant to LIAs that generate high-current relativistic electron beams, and some diagnostics will also be relevant to other accelerators. The Scorpius Accelerator will be the world’s most advance LIA. Although significant technological advancements have been incorporated throughout the machine, many performance aspects of Scorpius will be similar to those of FXR and DARHT Axis-I and -II. These LIAs offer the same challenges, whether it is suppressing beam instabilities, improving diagnostic accuracy, validating computer simulations and beam tunes, or reducing beam-target interaction effects. However, the ultimate figure of merit is consistent between these LIAs, which is spot size and dose.

43 PARTICLE ACCELERATORS↗

DEVELOPMENT OF A QUANTUM ELECTRON BEAM DIAGNOSTIC APPARATUS

Spatial properties of electron beams are the essential parameters needed in particle physics and accelerator research. Beam characterization using optical detection methods through the interaction between photons and electrons such as Compton scattering, or electro-optic sampling of the electric field of electrons have been extensively explored and successfully implemented as non-invasive diagnostics at various accelerator facilities. However, such methods often suffer from inherently low sensitivity. Here we present the study of a new type of electron beam diagnostic device for direct optical imaging of electron beams at various energy levels. The concept is based on the extremely high sensitivity of atoms, prepared in a specific "dark superposition" quantum state, to the external electric or magnetic perturbations induced by the passing charged particle, which allows atoms to change polarization of the probe light or absorb probe light and to fluoresce, enabling direct 3D imaging of the charged particles with high resolution. We report our recent experiment results and the design effort on a compact apparatus intended to be tested with the relativistic electron beams at Jefferson Laboratory.

Zhang, S.↗

Dynamic evolution of ultracold electron beams from nanostructured cathodes

Dynamic Coulomb expansion of dense, nonuniform particle beamlets can lead to causticlike formations in the charge density profile of the resultant beam. Such features only occur for cold beams where thermal diffusion of the particles is minimized. These phenomena have been observed experimentally for select cases with ion beams but not yet for electron beams as the electron dynamics occur over far faster timescales. We simulate the interaction of electron bunches while varying the initial transverse temperature and density profiles to determine the thresholds that characterize this pattern formation. Furthermore, we extend the simulations to geometric arrangements that are more pertinent to the nanotip cathode application and consider the effects of asymmetries and the impact of a low-density halo on the overall process. The simulations are conducted using a previously documented high-fidelity algorithm for collisional particle dynamics. These studies identify the temperature and density thresholds required for caustic formation and provide guidance for optimizing the design of nanoscale structured cathodes. We also demonstrate that the correlation between the final density patterns and the underlying beam parameters enables a virtual diagnostic tool for measuring ultralow emittance beams solely based on a transverse charge density profile.

43 PARTICLE ACCELERATORS↗

Extremum Seeking-Based Control System for Particle Accelerator Beam Loss Minimization

Particle accelerators throughout the world vary widely in terms of age and availability of advanced noninvasive diagnostics that provide varying levels of detail about the accelerated beams. Additionally, beam loss measurements and current monitors are ubiquitous in the accelerator community, they are noninvasive, and they are some of the most important metrics in terms of preventing damage or irradiation of beam pipes and equipment for high-energy machines. However, beam loss and current measurements are difficult to use for feedback tuning because of a lack of a known analytic relationship between scalar loss measurements throughout an accelerator and the hundreds of thousands of parameters that influence the beam and time variation of the beam source itself. In this work, we present a model-independent extremum seeking (ES) controller, which has been implemented for automated tuning and optimization of the Los Alamos Neutron Science Center (LANSCE) linear ion accelerator based only on scalar quantities, such as beam loss or flux measurements. We demonstrate the approach on various accelerator subsystems, including groups of radio frequency (RF) accelerating cavities, quadrupole magnets, bending magnets, and steering magnets. This tool is now available as a use graphical user interface (GUI) in the LANSCE control room, allowing beam physicists to choose arbitrary groups of parameters and beam loss or current monitors for adaptive tuning.

43 PARTICLE ACCELERATORS↗

Accelerator Physics at NSLS-II: Research Accomplishments in 2022

NSLS-II accelerator physicists are working on scientific support of the NSLS-II operations and start-up of the accelerator systems including Storage Ring, Injector, beam diagnostics, and top-off injection; improvement of beam stability and orbit feedbacks; commissioning of a superconducting wiggler for the HEX beamline; development of a new operation mode for time-resolved experiments. The routine lattice characterization is continued to keep tracking the machine, the storage ring lattice model including strong coupling is developed, and seasonal variations of the ring circumference are studied. The collaboration with the EIC project is ongoing. In the frameworks of three LDRD projects, the physicists are working on the lattice development, studies of collective effects, and specifications of alignment and stability for the NSLS-II accelerator upgrade; novel methods of lattice design and optimization; studies of free-electron laser options; ultrafast electron diffraction and microscopy. Research accomplishments achieved in 2022, are summarized in this report.

43 PARTICLE ACCELERATORS↗