Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Charge Diagnostics for Laser Plasma Accelerators

The electron energy dependence of a scintillating screen (Lanex Fast) was studied with sub-nanosecond electron beams ranging from 106 MeV to 1522 MeV at the Lawrence Berkeley National Laboratory Advanced Light Source (ALS) synchrotron booster accelerator. The sensitivity of the Lanex Fast decreased by 1% per 100 MeV increase of the energy. The linear response of the screen against the charge was verified with charge density and intensity up to 160 pC/mm{sup 2} and 0.4 pC/ps/mm{sup 2}, respectively. For electron beams from the laser plasma accelerator, a comprehensive study of charge diagnostics has been performed using a Lanex screen, an integrating current transformer, and an activation based measurement. The charge measured by each diagnostic was found to be within {+-}10%.

43 PARTICLE ACCELERATORS↗

Advanced Laser-driven Plasma Accelerator Electron-beam Diagnostics with COTR Techniques

A significant advance in laser-driven plasma accelerator (LPA) electron-beam diagnostics has recently been demonstrated based on coherent optical transition radiation (COTR) imaging. We find COTR signal strengths from a microbunched subset of beam exiting the LPA to be several orders of magnitude higher than that of incoherent optical transition radiation (OTR). The transverse sizes are only a few microns as deduced from the point-spread-function-related lobe structure. In addition, the far-field COTR interferometric images obtained on the same shot provide beam-size limits plus divergence and pointing information at the sub-mrad level when compared to a modified analytical model. The integrated image intensities can be used to estimate the microbunching fraction and relatable to the LPA process. Initial results in a collaborative LPA experiment will be reported for electron beam energies of about 215 MeV. A revised configuration is proposed to record energy and ene rgy spread via COTR on the same shot with the interferometer.

43 PARTICLE ACCELERATORS↗

Design and Analysis of a Single-Shot Longitudinal Phase Space Measurement Diagnostics at the Argonne Wakefield Accelerator

A single-shot longitudinal phase space diagnostics is currently being assembled at the Argonne Wakefield Accelerator (AWA). The diagnostics consists of mapping the longitudinal phase space coordinates to the transverse position space plane using a beamline that incorporates two magnetic dipoles arranged as a dogleg followed by an rf deflecting cavity. The deflecting cavity streaks the beam vertically while the dipole magnets bend horizontally. In this paper, we analyze analytically and via numerical simulations the performances of such diagnostics and their limitations. Simulations done in IMPACT-T shows good reconstruction of the longitudinal phase space.

43 PARTICLE ACCELERATORS↗

Ultrafast Diagnostics for Electron Beams from Laser Plasma Accelerators

We present an overview of diagnostic techniques for measuring key parameters of electron bunches from Laser Plasma Accelerators (LPAs). The diagnostics presented here were chosen because they highlight the unique advantages (e.g., diverse forms of electromagnetic emission) and difficulties (e.g., shot-to-shot variability) associated with LPAs. Non destructiveness and high resolution (in space and time and energy) are key attributes that enable the formation of a comprehensive suite of simultaneous diagnostics which are necessary for the full characterization of the ultrashort, but highly-variable electron bunches from LPAs.

43 PARTICLE ACCELERATORS↗

Design Aspects of the Emittance Diagnostic for the Scorpius Accelerator

Dear author, This is a reminder that we are expecting you to resubmit your IPAC'23 paper 1268 at https://indico.jacow.org/event/41/papers/2549/ in a format compliant with the IoP guidelines posted at https://publishingsupport.iopscience.iop.org/author-guidelines-for-conference-proceedings/ Could you please upload your paper as a PDF file in the IoP format at https://indico.jacow.org/event/41/papers/2549/ Title: The Design of the Emittance Diagnostic for the Scorpius Accelerator id: 1268 The deadline for resubmitting your paper is July 1st 2023 but we would appreciate if you could submit it earlier. Thank you in advance, Nicolas Delerue on behalf of the IPAC'23 LPR SPB

43 PARTICLE ACCELERATORS↗

Deployment and validation of predictive 6-dimensional beam diagnostics through generative reconstruction with standard accelerator elements

Understanding the 6-dimensional phase space distribution of particle beams is essential for optimizing accelerator performance. Conventional diagnostics such as use of transverse deflecting cavities offer detailed characterization but require dedicated hardware and space. Generative phase space reconstruction (GPSR) methods have shown promise in beam diagnostics, yet prior implementations still rely on such components. Here we present the first experimental implementation and validation of the GPSR methodology, realized by the use of standard accelerator elements including accelerating cavities and dipole magnets, to achieve complete 6-dimensional phase space reconstruction. Through simulations and experiments at the Pohang Accelerator Laboratory X-ray Free Electron Laser facility, we successfully reconstruct complex, nonlinear beam structures. Furthermore, we validate the methodology by predicting independent downstream measurements excluded from training, revealing the reconstruction closely resembling ground truth. This advancement establishes a pathway for predictive diagnostics across beamline segments while reducing hardware requirements and expanding applicability to various accelerator facilities.

Kim, Seongyeol [Pohang Univ. of Science and Techno↗

Upgrade of the MIT Linear Electrostatic Ion Accelerator (LEIA) for nuclear diagnostics development for Omega, Z and the NIF

The MIT Linear Electrostatic Ion Accelerator (LEIA) generates DD and D{sup 3}He fusion products for the development of nuclear diagnostics for Omega, Z, and the National Ignition Facility (NIF). Significant improvements to the system in recent years are presented. Fusion reaction rates, as high as 10{sup 7} s{sup -1} and 10{sup 6} s{sup -1} for DD and D{sup 3}He, respectively, are now well regulated with a new ion source and electronic gas control system. Charged fusion products are more accurately characterized, which allows for better calibration of existing nuclear diagnostics. In addition, in situ measurements of the on-target beam profile, made with a CCD camera, are used to determine the metrology of the fusion-product source for particle-counting applications. Finally, neutron diagnostics development has been facilitated by detailed Monte Carlo N-Particle Transport (MCNP) modeling of neutrons in the accelerator target chamber, which is used to correct for scattering within the system. These recent improvements have resulted in a versatile platform, which continues to support the existing nuclear diagnostics while simultaneously facilitating the development of new diagnostics in aid of the National Ignition Campaign at the National Ignition Facility.

43 PARTICLE ACCELERATORS↗

Diagnostic of laser-accelerated ion beams for the ELIMED project

The laser-generated plasma, in non equilibrium conditions, has peculiar properties depending strongly on the laser parameters, on the target composition and on the target geometry. Different fast diagnostic techniques can be employed for the plasma characterization in terms of particles and photons emission, plasma temperature and density, ion energy distribution, angular emission, yield and electric field acceleration. Particular attention is devoted to the proton emission from hydrogenated targets and to the proton diagnostics by using time of flight techniques and Thomson parabola spectrometry. The diagnostic techniques will be presented and discussed on the base of the development of the ELIMED project.

43 PARTICLE ACCELERATORS↗

Beam Size Measurement by Optical Diffraction Radiation and Laser System for Compton Polarimeter

Beam diagnostics is an essential constituent of any accelerator, so that it is named as "organs of sense" or "eyes of the accelerator." Beam diagnostics is a rich field. A great variety of physical effects or physical principles are made use of in this field. Some devices are based on electro-magnetic influence by moving charges, such as faraday cups, beam transformers, pick-ups; Some are related to Coulomb interaction of charged particles with matter, such as scintillators, viewing screens, ionization chambers; Nuclear or elementary particle physics interactions happen in some other devices, like beam loss monitors, polarimeters, luminosity monitors; Some measure photons emitted by moving charges, such as transition radiation, synchrotron radiation monitors and diffraction radiation-which is the topic of the first part of this thesis; Also, some make use of interaction of particles with photons, such as laser wire and Compton polarimeters-which is the second part of my thesis. Diagnostics let us perceive what properties a beam has and how it behaves in a machine, give us guideline for commissioning, controlling the machine and indispensable parameters vital to physics experiments. In the next two decades, the research highlight will be colliders (TESLA, CLIC, JLC) and fourth-generation light sources (TESLA FEL, LCLS, Spring 8 FEL) based on linear accelerator. These machines require a new generation of accelerator with smaller beam, better stability and greater efficiency. Compared with those existing linear accelerators, the performance of next generation linear accelerator will be doubled in all aspects, such as 10 times smaller horizontal beam size, more than 10 times smaller vertical beam size and a few or more times higher peak power. Furthermore, some special positions in the accelerator have even more stringent requirements, such as the interaction point of colliders and wigglor of free electron lasers. Higher performance of these accelerators increases the difficulty of diagnostics. For most cases, intercepting measurements are no longer acceptable, and nonintercepting method like synchrotron radiation monitor can not be applied to linear accelerators. The development of accelerator technology asks for simutanous diagnostics innovations, to expand the performance of diagnostic tools to meet the requirements of the next generation accelerators. Diffraction radiation and inverse Compton scattering are two of the most promising techniques, their nonintercepting nature avoids perturbance to the beam and damage to the instrumentation. This thesis is divided into two parts, beam size measurement by optical diffraction radiation and Laser system for Compton polarimeter. Diffraction radiation, produced by the interaction between the electric field of charged particles and the target, is related to transition radiation. Even though the theory of diffraction radiation has been discussed since 1960s, there are only a few experimental studies in recent years. The successful beam size measurement by optical diffraction radiation at CEBAF machine is a milestone: First of all, we have successfully demonstrated diffraction radiation as an effective nonintercepting diagnostics; Secondly, the simple linear relationship between the diffraction radiation image size and the actual beam size improves the reliability of ODR measurements; And, we measured the polarized components of diffraction radiation for the first time and I analyzed the contribution from edge radiation to diffraction radiation.

43 PARTICLE ACCELERATORS↗

Fiber-optic diagnostic system for future accelerator magnets

The next generation high energy physics accelerators will require magnetic fields at ~20 T. HTS coils will be an essential component of future accelerator magnets and several efforts are currently dedicated on designing 20 T HTS- LTS hybrid magnets. Among the existing challenges, there is the lack of a robust quench detection system for hybrid magnet technology. Another big challenge is represented by the high number of training quenches required by Nb3Sn magnets to reach performance level. In this framework it is important to find a tool that allow local real-time monitoring of magnet strain and temperature. In this paper, we propose the use of fiber optics sensors for diagnostic and quench detection in future accelerator superconducting magnets. Discrete and distributed fiber optic sensors have demonstrated to be a promising tool. The goal is to instrument hundreds of accelerator superconducting magnets and to move beyond the proof-of-concept level. Significant developments are still needed. Here, we are going to present the most recent results and discuss the most urgent technical developments in order to make those sensors a robust and reliable diagnostic tool for accelerator superconducting magnets over the next 10 year. We foresee that discrete fiber sensors will be a stable diagnostic probe for superconducting magnets over the next 3 to 5 years. More R&D work will be necessary for distributed fibers. The most urgent needs are the increase of sample rate and sensitivity. Close collaboration with vendors will be necessary to improve mechanical properties and fabrication processes in order to produce hundreds of meters of fiber and instrument a large number of accelerator superconducting magnets. Those R&D efforts will last up to 10 years with a founding level that spans between 5-10 M$.

43 PARTICLE ACCELERATORS↗

HOM Choice Study with Test Electronics for use as Beam Position Diagnostics in 3.9 GHz Accelerating Cavities in FLASH

Higher Order Modes (HOM) excited by the beam in the 3.9 GHz accelerating cavities in FLASH can be used for beam position diagnostics, as in a cavity beam position monitor. Previous studies of the modal choices within the complicated spectrum have revealed several options: cavity modes with strong coupling to the beam, and therefore with the potential for better position resolution, but which are propagating within all 4 cavities, and modes localized in the cavities or the beam pipes, which can give localized position information, but which provide worse resolution. For a better characterization of these options, a set of test electronics has been built, which can down-convert various frequencies between about 4 and 9 GHz to 70 MHz. The performance of various 20 MHz bands has been estimated. The best resolution of 20 \mu m was found for some propagating modes. Based on this study one band at ca. 5 GHz was chosen for high resolution position monitoring and a band at ca. 9 GHz for localized monitoring.

43 PARTICLE ACCELERATORS↗

Electro-optic techniques in electron beam diagnostics

Electron accelerators such as laser wakefield accelerators, linear accelerators driving free electron lasers, or femto-sliced synchrotrons, are capable of producing femtosecond-long electron bunches. Single-shot characterization of the temporal charge profile is crucial for operation, optimization, and application of such accelerators. A variety of electro-optic sampling (EOS) techniques exists for the temporal analysis. In EOS, the field profile from the electron bunch (or the field profile from its coherent radiation) will be transferred onto a laser pulse co-propagating through an electro-optic crystal. This paper will address the most common EOS schemes and will list their advantages and limitations. Strong points that all techniques share are the ultra-short time resolution (tens of femtoseconds) and the single-shot capabilities. Besides introducing the theory behind EOS, data from various research groups is presented for each technique.

43 PARTICLE ACCELERATORS↗

Ultrafast Diagnostics for Electron Beams from Laser Plasma Accelerators

We present an overview of diagnostic techniques for measuring key parameters of electron bunches from Laser Plasma Accelerators (LPAs). The diagnostics presented here were chosen because they highlight the unique advantages (e.g. diverse forms of electromagnetic emission) and difficulties (e.g. shot-to-shot variability) associated with LPAs. Non destructiveness and high resolution (in space and time and energy) are key attributes that enable the formation of a comprehensive suite of simultaneous diagnostics which are necessary for the full characterization of the ultrashort, but highly-variable electron bunches from LPAs.

43 PARTICLE ACCELERATORS↗

Laser-Accelerated Proton Beams as Diagnostics for Cultural Heritage

This paper introduces the first use of laser-generated proton beams as diagnostic for materials of interest in the domain of Cultural Heritage. Using laser-accelerated protons, as generated by interaction of a high-power short-pulse laser with a solid target, we can produce proton-induced X-ray emission spectroscopies (PIXE). By correctly tuning the proton flux on the sample, we are able to perform the PIXE in a single shot without provoking more damage to the sample than conventional methodologies. We verify this by experimentally irradiating materials of interest in the Cultural Heritage with laser-accelerated protons and measuring the PIXE emission. The morphological and chemical analysis of the sample before and after irradiation are compared in order to assess the damage provoked to the artifact. Monte Carlo simulations confirm that the temperature in the sample stays safely below the melting point. Compared to conventional diagnostic methodologies, laser-driven PIXE has the advantage of being potentially quicker and more efficient.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nondestructive diagnostics of charged particle beams in accelerators

The basic techniques for nondestructive diagnostics and detection of losses of charged particle beams used in accelerator engineering are reviewed. The data provided may help choose the systems for diagnostics and detection of losses of beams and give a qualitative picture of the operation principles of such devices. Quantitative characteristics that define the limits of applicability of each diagnostic technique are outlined.

43 PARTICLE ACCELERATORS↗

Feasibility of OTR Imaging For Laser-Driven Plasma Accelerator Electron-Beam Diagnostics

We report the initial considerations of using linearly polarized optical transition radiation (OTR) to characterize the electron beams of laser plasma accelerators (LPAs) such as at the Univ. of Texas at Austin. The two LPAs operate at 100 MeV and 2-GeV, and they currently have estimated normalized emittances at ~ 1-mm mrad regime with beam divergences less than 1/{\gamma} and beam sizes to be determined at the micron level. Analytical modeling results indicate the feasibility of using these OTR techniques for the LPA applications.

43 PARTICLE ACCELERATORS↗

Physics design of a 100 keV acceleration grid system for the diagnostic neutral beam for international tokamak experimental reactor

This paper describes the physics design of a 100 keV, 60 A H{sup -} accelerator for the diagnostic neutral beam (DNB) for international tokamak experimental reactor (ITER). The accelerator is a three grid system comprising of 1280 apertures, grouped in 16 groups with 80 apertures per beam group. Several computer codes have been used to optimize the design which follows the same philosophy as the ITER Design Description Document (DDD) 5.3 and the 1 MeV heating and current drive beam line [R. Hemsworth, H. Decamps, J. Graceffa, B. Schunke, M. Tanaka, M. Dremel, A. Tanga, H. P. L. De Esch, F. Geli, J. Milnes, T. Inoue, D. Marcuzzi, P. Sonato, and P. Zaccaria, Nucl. Fusion 49, 045006 (2009)]. The aperture shapes, intergrid distances, and the extractor voltage have been optimized to minimize the beamlet divergence. To suppress the acceleration of coextracted electrons, permanent magnets have been incorporated in the extraction grid, downstream of the cooling water channels. The electron power loads on the extractor and the grounded grids have been calculated assuming 1 coextracted electron per ion. The beamlet divergence is calculated to be 4 mrad. At present the design for the filter field of the RF based ion sources for ITER is not fixed, therefore a few configurations of the same have been considered. Their effect on the transmission of the electrons and beams through the accelerator has been studied. The OPERA-3D code has been used to estimate the aperture offset steering constant of the grounded grid and the extraction grid, the space charge interaction between the beamlets and the kerb design required to compensate for this interaction. All beamlets in the DNB must be focused to a single point in the duct, 20.665 m from the grounded grid, and the required geometrical aimings and aperture offsets have been calculated.

43 PARTICLE ACCELERATORS↗